984 resultados para Cascaded Converter
Resumo:
Switching power supplies are usually implemented with a control circuitry that uses constant clock frequency turning the power semiconductor switches on and off. A drawback of this customary operating principle is that the switching frequency and harmonic frequencies are present in both the conducted and radiated EMI spectrum of the power converter. Various variable-frequency techniques have been introduced during the last decade to overcome the EMC problem. The main objective of this study was to compare the EMI and steady-state performance of a switch mode power supply with different spread-spectrum/variable-frequency methods. Another goal was to find out suitable tools for the variable-frequency EMI analysis. This thesis can be divided into three main parts: Firstly, some aspects of spectral estimation and measurement are presented. Secondly, selected spread spectrum generation techniques are presented with simulations and background information. Finally, simulations and prototype measurements from the EMC and the steady-state performance are carried out in the last part of this work. Combination of the autocorrelation function, the Welch spectrum estimate and the spectrogram were used as a substitute for ordinary Fourier methods in the EMC analysis. It was also shown that the switching function can be used in preliminary EMC analysis of a SMPS and the spectrum and autocorrelation sequence of a switching function correlates with the final EMI spectrum. This work is based on numerous simulations and measurements made with the prototype. All these simulations and measurements are made with the boost DC/DC converter. Four different variable-frequency modulation techniques in six different configurations were analyzed and the EMI performance was compared to the constant frequency operation. Output voltage and input current waveforms were also analyzed in time domain to see the effect of the spread spectrum operation on these quantities. According to the results presented in this work, spread spectrum modulation can be utilized in power converter for EMI mitigation. The results from steady-state voltage measurements show, that the variable-frequency operation of the SMPS has effect on the voltage ripple, but the ripple measured from the prototype is still acceptable in some applications. Both current and voltage ripple can be controlled with proper main circuit and controller design.
Resumo:
Diplomityön tavoitteena oli selvittää energianmuuntimen kaupallistamiseksi kannattavin valmistuskonsepti. Työssä esitettiin energianmuuntimelle kaksi mahdollista valmistuskonseptia; hitsattu rakenne ja tuotteen rungon valaminen. Tuotteen uuden rakenteen suunnittelu suoritettiin DFMA -projektin etenemisjärjestyksen mukaisesti. Uuden rakenteen suunnittelun tuloksena DFMA -projektille asetetut tavoitteet saavutettiin. Työssä valittiin rungon valamiseen soveltuvat valumenetelmät, joita ovat hiekkavalu, Lost Foam ja Replicast CS. Kappaleen valettavuudelle suoritettiin analyysi, jonka perusteella ennen diplomityön aloittamista suunniteltu valurunko ei ole valmistettavissa työssä esitettynä konstruktiona. Johtopäätöksenä rungon valamisesta todettiin, että valurunko on suunniteltava uudestaan huomioimalla diplomityössä esitetyt toimenpiteet valmistettavuuden parantamiseksi. Mikäli tuotekehitysprosessia ei jatketa valurungon sunnittelun osalta, valitaan hitsattu rakenne energianmuuntimen valmistuskonseptiksi.
Resumo:
A high-frequency cyclonverter acts as a direct ac-to-ac power converter circuit that does not require a diode bidge rectifier. Bridgeless topology makes it possible to remove forward voltage drop losses that are present in a diode bridge. In addition, the on-state losses can be reduced to 1.5 times the on-state resistance of switches in half-bridge operation of the cycloconverter. A high-frequency cycloconverter is reviewed and the charging effect of the dc-capacitors in ``back-to-back'' or synchronous mode operation operation is analyzed. In addition, a control method is introduced for regulating dc-voltage of the ac-side capacitors in synchronous operation mode. The controller regulates the dc-capacitors and prevents switches from reaching overvoltage level. This can be accomplished by variating phase-shift between the upper and the lower gate signals. By adding phase-shift between the gate signal pairs, the charge stored in the energy storage capacitors can be discharged through the resonant load and substantially, the output resonant current amplitude can be improved. The above goals are analyzed and illustrated with simulation. Theory is supported with practical measurements where the proposed control method is implemented in an FPGA device and tested with a high-frequency cycloconverter using super-junction power MOSFETs as switching devices.
Resumo:
The aim of the present study was to compare the modulation of heart rate in a group of postmenopausal women to that of a group of young women under resting conditions on the basis of R-R interval variability. Ten healthy postmenopausal women (mean ± SD, 58.3 ± 6.8 years) and 10 healthy young women (mean ± SD, 21.6 ± 0.82 years) were submitted to a control resting electrocardiogram (ECG) in the supine and sitting positions over a period of 6 min. The ECG was obtained from a one-channel heart monitor at the CM5 lead and processed and stored using an analog to digital converter connected to a microcomputer. R-R intervals were calculated on a beat-to-beat basis from the ECG recording in real time using a signal-processing software. Heart rate variability (HRV) was expressed as standard deviation (RMSM) and mean square root (RMSSD). In the supine position, the postmenopausal group showed significantly lower (P<0.05) median values of RMSM (34.9) and RMSSD (22.32) than the young group (RMSM: 62.11 and RMSSD: 49.1). The same occurred in the sitting position (RMSM: 33.0 and RMSSD: 18.9 compared to RMSM: 57.6 and RMSSD: 42.8 for the young group). These results indicate a decrease in parasympathetic modulation in postmenopausal women compared to young women which was possibly due both to the influence of age and hormonal factors. Thus, time domain HRV proved to be a noninvasive and sensitive method for the identification of changes in autonomic modulation of the sinus node in postmenopausal women.
Resumo:
Virtual environments and real-time simulators (VERS) are becoming more and more important tools in research and development (R&D) process of non-road mobile machinery (NRMM). The virtual prototyping techniques enable faster and more cost-efficient development of machines compared to use of real life prototypes. High energy efficiency has become an important topic in the world of NRMM because of environmental and economic demands. The objective of this thesis is to develop VERS based methods for research and development of NRMM. A process using VERS for assessing effects of human operators on the life-cycle efficiency of NRMM was developed. Human in the loop simulations are ran using an underground mining loader to study the developed process. The simulations were ran in the virtual environment of the Laboratory of Intelligent Machines of Lappeenranta University of Technology. A physically adequate real-time simulation model of NRMM was shown to be reliable and cost effective in testing of hardware components by the means of hardware-in-the-loop (HIL) simulations. A control interface connecting integrated electro-hydraulic energy converter (IEHEC) with virtual simulation model of log crane was developed. IEHEC consists of a hydraulic pump-motor and an integrated electrical permanent magnet synchronous motorgenerator. The results show that state of the art real-time NRMM simulators are capable to solve factors related to energy consumption and productivity of the NRMM. A significant variation between the test drivers is found. The results show that VERS can be used for assessing human effects on the life-cycle efficiency of NRMM. HIL simulation responses compared to that achieved with conventional simulation method demonstrate the advances and drawbacks of various possible interfaces between the simulator and hardware part of the system under study. Novel ideas for arranging the interface are successfully tested and compared with the more traditional one. The proposed process for assessing the effects of operators on the life-cycle efficiency will be applied for wider group of operators in the future. Driving styles of the operators can be analysed statistically from sufficient large result data. The statistical analysis can find the most life-cycle efficient driving style for the specific environment and machinery. The proposed control interface for HIL simulation need to be further studied. The robustness and the adaptation of the interface in different situations must be verified. The future work will also include studying the suitability of the IEHEC for different working machines using the proposed HIL simulation method.
Resumo:
Traction motor design significantly differs from industrial machine design. The starting point is the load cycle instead of the steady-state rated operation point. The speed of the motor varies from zero to very high speeds. At low speeds, heavy overloading is used for starting, and the field-weakening region also plays an important role. Finding a suitable fieldweakening point is one of the important design targets. At the lowest speeds, a high torque output is desired, and all current reserves of the supplying converter unit are used to achieve the torque. In this paper, a 110-kW 2.5-p.u. starting torque and a maximum 2.5-p.u. speed permanent-magnet traction motor will be studied. The field-weakening point is altered by varying the number of winding turns of machine. One design is selected for prototyping. Theoretical results are verified by measurements.
Resumo:
Several methods have been described to measure intraocular pressure (IOP) in clinical and research situations. However, the measurement of time varying IOP with high accuracy, mainly in situations that alter corneal properties, has not been reported until now. The present report describes a computerized system capable of recording the transitory variability of IOP, which is sufficiently sensitive to reliably measure ocular pulse peak-to-peak values. We also describe its characteristics and discuss its applicability to research and clinical studies. The device consists of a pressure transducer, a signal conditioning unit and an analog-to-digital converter coupled to a video acquisition board. A modified Cairns trabeculectomy was performed in 9 Oryctolagus cuniculus rabbits to obtain changes in IOP decay parameters and to evaluate the utility and sensitivity of the recording system. The device was effective for the study of kinetic parameters of IOP, such as decay pattern and ocular pulse waves due to cardiac and respiratory cycle rhythm. In addition, there was a significant increase of IOP versus time curve derivative when pre- and post-trabeculectomy recordings were compared. The present procedure excludes corneal thickness and error related to individual operator ability. Clinical complications due to saline infusion and pressure overload were not observed during biomicroscopic evaluation. Among the disadvantages of the procedure are the requirement of anesthesia and the use in acute recordings rather than chronic protocols. Finally, the method described may provide a reliable alternative for the study of ocular pressure dynamic alterations in man and may facilitate the investigation of the pathogenesis of glaucoma.
Resumo:
A glicosiltransferase de Erwinia sp D12 é capaz de converter a sacarose em isomaltulose (6-o-alfa-glicopiranosil D-frutofuranose), um açúcar alternativo que apresenta baixo potencial cariogênico, e que pode ser utilizado em chocolates, gomas de mascar e balas. A isomaltulose é também utilizada na produção de isomalte, uma mistura de açúcar álcool, de baixo valor calórico e baixo potencial cariogênico. No estudo da influência dos componentes do meio de cultivo, na produção de glicosiltransferase, em frascos agitados, foi obtido maior atividade da enzima (12,8 unidades de atividade/mL do meio de cultura) em meio de cultura A constituído de melaço 12% (p/v) de sólidos solúveis totais, peptona 4% (p/v) e extrato de carne 0,4% (p/v). No estudo do efeito do tempo e da temperatura na fermentação da linhagem de Erwinia sp D12, em fermentador New Brunswick de 3L, contendo meio de cultura A, foi obtida maior atividade de glicosiltransferase (15,6 unidades de atividade/ mL de meio de cultura) na fase exponencial de crescimento após 8 horas de fermentação a 30ºC. Na produção de isomaltulose a partir da sacarose utilizando-se células de Erwinia sp D12 imobilizadas em alginato de cálcio, estudou-se o efeito da temperatura (25 - 35ºC) e da concentração de substrato (12,5 - 60% p/v). Foi obtido um rendimento em torno de 50% de isomaltulose, com soluções de sacarose entre 20-30% (p/v) a 35ºC. Concentrações em excesso de sacarose (ao redor de 40% p/v) afetaram a atividade da célula imobilizada, diminuindo a conversão de sacarose em isomaltulose. O xarope de isomaltulose foi purificado através de cromatografia de troca iônica e o eluato cristalizado por abaixamento de temperatura. Os cristais apresentaram 91,39% de isomaltulose.
Resumo:
Wind turbines based on doubly fed induction generators (DFIG) become the most popular solution in high power wind generation industry. While this topology provides great performance with the reduced power rating of power converter, it has more complicated structure in comparison with full-rated topologies, and therefore leads to complexity of control algorithms and electromechanical processes in the system. The purpose of presented study is to present a proper vector control scheme for the DFIG and overall control for the WT to investigate its behavior at different wind speeds and in different grid voltage conditions: voltage sags, magnitude and frequency variations. The key principles of variable-speed wind turbine were implemented in simulation model and demonstrated during the study. Then, based on developed control scheme and mathematical model, the set of simulation is made to analyze reactive power capabilities of the DFIG wind turbine. Further, the rating of rotor-side converter is modified to not only generate active rated active power, but also to fulfill Grid Codes. Results of modelling and analyzing of the DFIG WT behavior under different speeds and different voltage conditions are presented in the work.
Resumo:
The two central goals of this master's thesis are to serve as a guidebook on the determination of uncertainty in efficiency measurements and to investigate sources of uncertainty in efficiency measurements in the field of electric drives by a literature review, mathematical modeling and experimental means. The influence of individual sources of uncertainty on the total instrumental uncertainty is investigated with the help of mathematical models derived for a balance and a direct air cooled calorimeter. The losses of a frequency converter and an induction motor are measured with the input-output method and a balance calorimeter at 50 and 100 % loads. A software linking features of Matlab and Excel is created to process measurement data, calculate uncertainties and to calculate and visualize results. The uncertainties are combined with both the worst case and the realistic perturbation method and distributions of uncertainty by source are shown based on experimental results. A comparison of the calculated uncertainties suggests that the balance calorimeter determines losses more accurately than the input-output method with a relative RPM uncertainty of 1.46 % compared to 3.78 - 12.74 % respectively with 95 % level of confidence at the 93 % induction motor efficiency or higher. As some principles in uncertainty analysis are open to interpretation the views and decisions of the analyst can have noticeable influence on the uncertainty in the measurement result.
Resumo:
Hybridiajoneuvosovellukset vaativat usein sekä korkea- että matalajännitejärjestelmän. Korkeajännitejärjestelmä sisältää yleensä energiavaraston, joka on joko superkondansaattori tai korkeajänniteakusto, dieselgeneraattorin tai range extenderin ja ajokäytön. Korkeajännitejärjestelmään liitetään usein myös erilaisia apukäyttöjä kuten kompressoreita ja hydraulipumppuja. Matalajännitejärjelmä koostuu yleensä ohjausyksiköistä, ajovaloista, yms. laitteista. Perinteisesti matalajännitejärjestelmää on syötetty dieselmoottorin laturista, mutta korkeajännitejärjestelmien myötä DC/DC-hakkurin käyttäminen korkea- ja matalajännitejärjestelmien välillä on herättänyt kiinnostusta, koska tällöin laturin voisi poistaa ja matalajänniteakustoa pienentää. Tässä työssä kuvatun monilähöisen tehonmuokkaimen invertterisilta soveltuu apukäyttöjen ajamiseen, ja erotettu DC/DC-hakkuri matalajännitejärjestelmän syöttämiseen. Tässä työssä käydään läpi edellä mainitun tehonmuokkaimen suunnittelu, keskittyen eritoten laitteen korkeajänniteosien mitoitukseen ja termiseen suunniteluun. DC/DC-hakkurin osalta perinteisiä piistä valmistettuja IGBT transistoreja vertaillaan piikarbidi MOSFET transistoreihin. Lämpömallilaskujen paikkaansapitävyyttä tutkitaan suorittamalla prototyyppilaitteelle hyötysuhdemittaus, jonka tuloksia verrataan laskettuihin tuloksiin. Lämpömallin parannusmahdollisuuksia käsitellään myös hyötysuhdemittauksen tulosten perusteella.
Resumo:
Ajoneuvoissa, kuten busseissa, käytetään yleensä 24 VDC järjestelmiä ja tämä ei muutu myöskään sähköajoneuvojen kohdalla. Sähköajoneuvoissakin tarvitaan siis 24 VDC matalajänniteakustoja valoille, pyyhkijöille ja muille matalan jännitteen järjestelmille. Lisäksi sähköajoneuvoissa on esimerkiksi ilmastointi ja paineilmankompressori, jotka tarvitsevat taajuusmuuttajan pyörittämään niitä. Tässä työssä suunnitellaan suuren virran piilevy DC/DC-muuntimeen, joka on osa ajoneuvokäyttöön suunnitellun invertterin ja DC/DC-muuntimen yhdistelmälaitetta. Työn pääpaino on piirilevyn suunnittelussa, mutta työssä kerrotaan lyhyesti koko laitteen kytkentä ja käyttötarkoitus. Työssä kerrotaan myös tehopiirilevylle tulevien komponenttien valinta, mitoitus ja jäähdytys. Käydään läpi suuren virran piirilevysuunnittelun mitoitusperiaatteet ja mitä seikkoja siinä erityisesti tulee ottaa huomioon. Lisäksi käsitellään piirilevyn liityntöjä ja virtakiskojen lämpenemää virranahtautumisen takia. Suunniteltua piirilevyä mitataan ja sen toimintaa kokeillaan prototyyppilaitteessa. Protoyyppilaitteella havaitaan virtakiskojen lämpenevän liikaa ja huomataan ongelma kytkenssä. Kytkentää korjattiin ja toimintaa analysoitiin uudestaan, jonka jälkeen havaittiin piirilevyn lämpenemän tippuneen 20 °C. Lopputuloksena piirilevyn lämpenemä, korjatulla kytkennällä, on suunnitellun mukainen. Lopussa esitetään piirilevyn korvaamista moduuliratkaisulla laitteen parantamiseksi sarjatuotantoon.
Resumo:
The awareness and concern of our environment together with legislation have set more and more tightening demands for energy efficiency of non-road mobile machinery (NRMM). Integrated electro-hydraulic energy converter (IEHEC) has been developed in Lappeenranta University of Technology (LUT). The elimination of resistance flow, and the recuperation of energy makes it very efficient alternative. The difficulties of IEHEC machine to step to the market has been the requirement of one IEHEC machine per one actuator. The idea is to switch IEHEC between two actuators of log crane using fast on/off valves. The control system architecture is introduced. The system has been simulated in co-simulation using two different software. The simulated responses of pump-controlled system is compared to the responses of the conventional valve-controlled system.
Power Electronic Converters in Low-Voltage Direct Current Distribution – Analysis and Implementation
Resumo:
Over the recent years, smart grids have received great public attention. Many proposed functionalities rely on power electronics, which play a key role in the smart grid, together with the communication network. However, “smartness” is not the driver that alone motivates the research towards distribution networks based on power electronics; the network vulnerability to natural hazards has resulted in tightening requirements for the supply security, set both by electricity end-users and authorities. Because of the favorable price development and advancements in the field, direct current (DC) distribution has become an attractive alternative for distribution networks. In this doctoral dissertation, power electronic converters for a low-voltage DC (LVDC) distribution system are investigated. These include the rectifier located at the beginning of the LVDC network and the customer-end inverter (CEI) on the customer premises. Rectifier topologies are introduced, and according to the LVDC system requirements, topologies are chosen for the analysis. Similarly, suitable CEI topologies are addressed and selected for study. Application of power electronics into electricity distribution poses some new challenges. Because the electricity end-user is supplied with the CEI, it is responsible for the end-user voltage quality, but it also has to be able to supply adequate current in all operating conditions, including a short-circuit, to ensure the electrical safety. Supplying short-circuit current with power electronics requires additional measures, and therefore, the short-circuit behavior is described and methods to overcome the high-current supply to the fault are proposed. Power electronic converters also produce common-mode (CM) and radio-frequency (RF) electromagnetic interferences (EMI), which are not present in AC distribution. Hence, their magnitudes are investigated. To enable comprehensive research on the LVDC distribution field, a research site was built into a public low-voltage distribution network. The implementation was a joint task by the LVDC research team of Lappeenranta University of Technology and a power company Suur-Savon S¨ahk¨o Oy. Now, the measurements could be conducted in an actual environment. This is important especially for the EMI studies. The main results of the work concern the short-circuit operation of the CEI and the EMI issues. The applicability of the power electronic converters to electricity distribution is demonstrated, and suggestions for future research are proposed.