936 resultados para Cable Supported Bridges
Resumo:
ObjectivesThe aim of this study was to evaluate the quality of life and satisfaction of patients wearing implant-supported fixed partial dentures.Materials &methodsA total of 106 patients were selected and submitted to clinical examination and collection of the demographic data for evaluation of the implant-supported fixed dentures conditions. All participants agreed to answer to the Oral Health Impact Profile (OHIP-EDENT) questionnaire and another questionnaire about satisfaction with the implant-supported prostheses. The patients were classified into the following three groups for statistical analysis: patients wearing splinted implant-supported prosthesis (E), patients wearing single implant-supported prosthesis (U), and patients wearing single implant-supported prosthesis associated with splinted prosthesis (E+U). Kruskal-Wallis test was used to compare the answers between the groups, and a logistic regression model was measured to verify the relation between variables of the patients and the questionaries'items.ResultsThere were significant differences among groups (P=0.006) for discomfort during surgery itself of the satisfaction questionnaire. The marital status, groups, and hygiene condition were significant mainly for physical pain item.ConclusionsIt was concluded that the patients presented high level of satisfaction and quality of life for the most of the items evaluated as well as the groups showed similar results.
Resumo:
The aim of this in vitro study was to use strain gauge (SG) analysis to compare the effects of the implant-abutment joint, the coping, and the location of load on strain distribution in the bone around implants supporting 3-unit fixed partial prostheses. Three external hexagon (EH) implants and 3 internal hexagon (IH) implants were inserted into 2 polyurethane blocks. Microunit abutments were screwed onto their respective implant groups. Machined cobalt-chromium copings and plastic copings were screwed onto the abutments, which received standard wax patterns. The wax patterns were cast in a cobalt-chromium alloy (n = 5): group 1 = EH/machined. group 2 = EH/plastic, group 3 = IH/machined, and group 4 = IH/plastic. Four SGs were bonded onto the surface of the block tangentially to the implants. Each metallic structure was screwed onto the abutments and an axial load of 30 kg was applied at 5 predetermined points. The magnitude of microstrain on each SG was recorded in units of microstrain (mu epsilon). The data were analyzed using 3-factor repeated measures analysis of variance and a Tukey test (alpha = 0.05). The results showed statistically significant differences for the type of implant-abutment joint, loading point, and interaction at the implant-abutment joint/loading point. The IH connection showed higher microstrain values than the EH connection. It was concluded that the type of coping did not interfere in the magnitude of microstrain, but the implant/abutment joint and axial loading location influenced this magnitude.
Resumo:
A spayed crossbred female dog was presented due to progressive weight loss, emesis and anorexia over the preceding month. A complete blood count, urinalysis, serum biochemical panel, and ultrasound were initially performed. Computed tomography urography was performed as a complementary exam. Based on ultrasound and CT findings an exploratory celiotomy was performed to remove hyperdense structures that could be the cause of the hydronephrosis and hydroureter in both kidneys. An extensive granulomatous reaction was found near the caudal pole to the left kidney. A nylon cable tie adhering firmly to this tissue was removed during surgical excision. On the dorsal surface of the bladder an extensive granulomatous reaction that had entrapped the right ureter was also noted. Another nylon cable tie was removed and the ureter was released. Eight months postoperatively, the dog was in good general physical condition, showing appetite and vigour. Abdominal ultrasonography showed improvement of the hydronephrosis in both kidneys. The urea ratio was normal, but the creatinine level was slightly elevated, suggesting a guarded prognosis. Thus, bilateral hydronephrosis as observed in the present study should be considered as a major complication after elective ovariohysterectomy.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Complete denture fabrication can be a treatment challenge for many dentists, especially when the patient has remaining teeth. So, planning for use of clinical alternatives to improve the treatment prognosis and to enable greater comfort to patient must be considered. This case report describes the use of remaining roots to aid in the stability, support and retention of root-supported overdentures. Thus, immediate prostheses were planned for temporary rehabilitation prior to definitive overdentures. The aim of this study was to demonstrate the planning of root-supported overdentures attached with a ball system for retention associated with immediate dentures between the periods of preparation to fabrication of the definitive overdentures. The proposed treatment met the patient's needs such as being able to carry on normal activities during the sequencing of procedures to be performed over a period of time. The treatment had longevity with patient's knowledge about the necessity of oral hygiene and periodic controls.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
A structural study of CuO supported on a CeO2-TiO2 system was undertaken using X-ray diffraction (XRD) and X-ray absorption spectroscopy (XAS) techniques. The results of XRD revealed the presence of only two phases, TiO2 anatase and CeO2 cerianite. A trend towards smaller TiO2 crystallites was observed when cerium content increased. When the amount of cerium increased, Ti K-edge XANES analysis showed an increasing distortion of Ti sites. The results of Ce LIII-edge EXAFS showed that Ce atoms are coordinated by eight oxygen atoms at 2.32 Å. For the sample containing a small amount of cerium, the EXAFS analysis indicated that the local structure around Ce atoms was highly distorted. The catalysts presented quite different Cu K-edge XANES spectra compared to the spectra of the CuO and Cu2O reference compounds. The Cu-O mean bond length was close to that of the CuO and the Cu atoms in the catalysts are surrounded by approximately four oxygen atoms in their first shell. Copper supported on the ceria-modified titania support catalysts displayed a better performance in the methanol dehydrogenation when compared to copper supported only on titania or on ceria. © 2002 Plenum Publishing Corporation.
Resumo:
Esthetics is important for success of implant-supported prostheses. This study aimed to review esthetics concepts for implant treatment. Research in the PubMed database included studies published from 1995 to 2010 with the keywords implant esthetics, implant-supported prostheses, and esthetics. Forty-five studies were evaluated regarding the presurgical planning, surgical phase, and temporary and final restoration phases. It was concluded that esthetics in implant-supported prostheses results from a multidisciplinary approach from planning until insertion of the final restoration.
Resumo:
Background: Considering the limited qualitative and quantitative bone in the posterior arch, this modality of prosthetic treatment could provide a positive emotional factor reestablished by immovability of the anterior fixed implant-supported segment. Objective: This clinical report demonstrates the possibility of achieving positive results with a removable partial denture connected to an implant-supported fixed prosthesis associated to an extra resilient attachment. Clinical significance: In cases of posterior mandibular and maxilla atrophy added to the patients desire against the bone graft, this kind of prosthetic treatment has an important place as an alternative.
Resumo:
The alveolar ridge shape plays an important role in predicting the demand on the support tooth and alveolar bone in the removable partial denture (RPD) treatment. However, these data are unclear when the RPD is associated with implants. This study evaluated the influence of the alveolar ridge shape on the stress distribution of a free-end saddle RPD partially supported by implant using 2-dimensioanl finite element analysis (FEA). Four mathematical models (M) of a mandibular hemiarch simulating various alveolar ridge shapes (1-distal desceding, 2- concave, 3-horizontal and 4-distal ascending) were built. Tooth 33 was placed as the abutment. Two RPDs, one supported by tooth and fibromucosa (MB) and other one supported by tooth and implant (MC) were simulated. MA was the control (no RPD). The load (50N) were applied simultaneously on each cusp. Appropriate boundary conditions were assigned on the border of alveolar bone. Ansys 10.0 software was used to calculate the stress fields and the von Mises equivalent stress criteria (σvM) was applied to analyze the results. The distal ascending shape showed the highest σvM for cortical and medullar bone. The alveolar ridge shape had little effect on changing the σvM based on the same prosthesis, mainly around the abutment tooth.
Resumo:
The aim of this study was to evaluate the deformation suffered by cantilevered implant-supported fixed prostheses frameworks cast in silver-palladium alloy and coated with two occlusal veneering materials: acrylic resin or porcelain. Material and Methods: Two strain gauges were bonded to the inferior surface of the silver-palladium framework and two other were bonded to the occlusal surface of the prosthesis framework covered with ceramic and acrylic resin on each of its two halves. The framework was fixed to a metallic master model and a 35.2 N compression force was applied to the cantilever at 10, 15 and 20 mm from the most distal implant. The measurements of deformation by compression and tension were obtained. The statistical 2-way ANOVA test was used for individual analysis of the experiment variables and the Tukey test was used for the interrelation between all the variables (material and distance of force application). Results: The results showed that both variables had influence on the studied factors (deformation by compression and tension). Conclusion: The ceramic coating provided greater rigidity to the assembly and therefore less distortion compared with the uncoated framework and with the resin-coated framework. The cantilever arm length also influenced the prosthesis rigidity, causing higher deformation the farther the load was applied from the last implant.
Resumo:
Obituary of Raymond Millard Cable, American parasitologist, 1909-1995.