951 resultados para Breathing apparatus
Resumo:
The infrared (IR) spectroscopic data and Raman spectroscopic properties for a series of 13 “pinwheel-like” homoleptic bis(phthalocyaninato) rare earth complexes M[Pc(α-OC5H11)4]2 [M = Y and Pr–Lu except Pm; H2Pc(α-OC5H11)4 = 1,8,15,22-tetrakis(3-pentyloxy)phthalocyanine] have been collected and comparatively studied. Both the IR and Raman spectra for M[Pc(α-OC5H11)4]2 are more complicated than those of homoleptic bis(phthalocyaninato) rare earth analogues, namely M(Pc)2 and M[Pc(OC8H17)8]2, but resemble (for IR) or are a bit more complicated (for Raman) than those of heteroleptic counterparts M(Pc)[Pc(α-OC5H11)4], revealing the decreased molecular symmetry of these double-decker compounds, namely S8. Except for the obvious splitting of the isoindole breathing band at 1110–1123 cm−1, the IR spectra of M[Pc(α-OC5H11)4]2 are quite similar to those of corresponding M(Pc)[Pc(α-OC5H11)4] and therefore are similarly assigned. With laser excitation at 633 nm, Raman bands derived from isoindole ring and aza stretchings in the range of 1300–1600 cm−1 are selectively intensified. The IR spectra reveal that the frequencies of pyrrole stretching and pyrrole stretching coupled with the symmetrical CH bending of –CH3 groups are sensitive to the rare earth ionic size, while the Raman technique shows that the bands due to the isoindole stretchings and the coupled pyrrole and aza stretchings are similarly affected. Nevertheless, the phthalocyanine monoanion radical Pc′− IR marker band of bis(phthalocyaninato) complexes involving the same rare earth ion is found to shift to lower energy in the order M(Pc)2 > M(Pc)[Pc(α-OC5H11)4] > M[Pc(α-OC5H11)4]2, revealing the weakened π–π interaction between the two phthalocyanine rings in the same order.
Resumo:
A new Expiratory Droplet Investigation System (EDIS) was used to conduct the most comprehensive program of study to date, of the dilution corrected droplet size distributions produced during different respiratory activities.----- Distinct physiological processes were responsible for specific size distribution modes. The majority of particles for all activities were produced in one or more modes, with diameters below 0.8 µm. That mode occurred during all respiratory activities, including normal breathing. A second mode at 1.8 µm was produced during all activities, but at lower concentrations.----- Speech produced particles in modes near 3.5 µm and 5 µm. The modes became most pronounced during continuous vocalization, suggesting that the aerosolization of secretions lubricating the vocal chords is a major source of droplets in terms of number.----- Non-eqilibrium droplet evaporation was not detectable for particles between 0.5 and 20 μm implying that evaporation to the equilibrium droplet size occurred within 0.8 s.
Resumo:
intimate drowning 50 minute performance + installation work ice | salt | tears | This work is about death. Grief The relationships before The aftermath - of confusion, violence, isolation The never ending questions The devastating loss and paranoia "Since my wife died, I have spent the last six years treading water - trying to stop myself from drowning. Sometimes I catch myself not breathing. I have to remind myself that I can't live underwater no matter how much I want to." Grief. Loss. Tears. Fear. Sadness Water. Milk. Salt. Ice Falling. Waiting Submerged. Suffocated. Broken ties Intention. Lack of focus. Intensity of focus Fighting. Screaming. Wailing Blue. White. Black. Blackness The doors open: we walk through a gauze curtain and discover a dark space with a square of light in the middle of the room. As we walk closer to the light, we see a girl writing in charcoal on the floor around a square box filled with milk. She is writing the same thing over and over. The more she writes the more desperate she becomes: I am listening… We have to keep walking past. She isn’t writing for us. We find our seats Two people: one slowly breaking the hundreds of fragile strings that tie her to the other. The other is pleading with her to stop: Please. Please don’t. Please Avril. …Please don’t One girl facing away from us. She is slowly swimming on the spot without water. Projected next to her are images of her drowning under water. Salt falls in front of her. Behind her. A wall of salt. She is bound to the spot. Underwater and still breathing. Swimming in her own tears. She won’t escape. She wants to stay, but desires nothing Two people standing in a large square box filled with milk. They start in intimacy. The relationship begins to dissolve before us. One fights to be with/on/behind the other. The other fights her off. The milk is splashed. Why aren't they being careful? In the darkness there is scrubbing. Someone is scrubbing the floor. The other girl is on her knees trying to erase the original writing. The traces left behind that we have no control over. We only see her for a second, but hear her in the darkness. Scrubbing. It is pointless. You can't erase the past.
Resumo:
Background The accurate measurement of Cardiac output (CO) is vital in guiding the treatment of critically ill patients. Invasive or minimally invasive measurement of CO is not without inherent risks to the patient. Skilled Intensive Care Unit (ICU) nursing staff are in an ideal position to assess changes in CO following therapeutic measures. The USCOM (Ultrasonic Cardiac Output Monitor) device is a non-invasive CO monitor whose clinical utility and ease of use requires testing. Objectives To compare cardiac output measurement using a non-invasive ultrasonic device (USCOM) operated by a non-echocardiograhically trained ICU Registered Nurse (RN), with the conventional pulmonary artery catheter (PAC) using both thermodilution and Fick methods. Design Prospective observational study. Setting and participants Between April 2006 and March 2007, we evaluated 30 spontaneously breathing patients requiring PAC for assessment of heart failure and/or pulmonary hypertension at a tertiary level cardiothoracic hospital. Methods SCOM CO was compared with thermodilution measurements via PAC and CO estimated using a modified Fick equation. This catheter was inserted by a medical officer, and all USCOM measurements by a senior ICU nurse. Mean values, bias and precision, and mean percentage difference between measures were determined to compare methods. The Intra-Class Correlation statistic was also used to assess agreement. The USCOM time to measure was recorded to assess the learning curve for USCOM use performed by an ICU RN and a line of best fit demonstrated to describe the operator learning curve. Results In 24 of 30 (80%) patients studied, CO measures were obtained. In 6 of 30 (20%) patients, an adequate USCOM signal was not achieved. The mean difference (±standard deviation) between USCOM and PAC, USCOM and Fick, and Fick and PAC CO were small, −0.34 ± 0.52 L/min, −0.33 ± 0.90 L/min and −0.25 ± 0.63 L/min respectively across a range of outputs from 2.6 L/min to 7.2 L/min. The percent limits of agreement (LOA) for all measures were −34.6% to 17.8% for USCOM and PAC, −49.8% to 34.1% for USCOM and Fick and −36.4% to 23.7% for PAC and Fick. Signal acquisition time reduced on average by 0.6 min per measure to less than 10 min at the end of the study. Conclusions In 80% of our cohort, USCOM, PAC and Fick measures of CO all showed clinically acceptable agreement and the learning curve for operation of the non-invasive USCOM device by an ICU RN was found to be satisfactorily short. Further work is required in patients receiving positive pressure ventilation.
Resumo:
Debates concerning the veracity, ethics and politics of the documentary form circle endlessly around the function of those who participate in it, and the meaning attributed to their participation. Great significance is attached to the way that documentary filmmakers do or do not participate in the world they seek to represent, just as great significance is attached to those subjects whose participation extends beyond playing the part of eyewitness or expert, such that they become part of the very filmmaking process itself. This Ph.D. explores the interface between documentary practice and participatory culture by looking at how their practices, discursive fields and histories intersect, but also by looking at how participating in one might mean participating in the other. In short, the research is an examination of participatory culture through the lens of documentary practice and documentary criticism. In the process, however, this examination of participatory culture will in turn shed light on documentary thinking, especially the meaning and function of ‘the participant’ in contemporary documentary practice. A number of ways of conceiving of participation in documentary practice are discussed in this research, but one of the ideas that gives purpose to that investigation is the notion that the participant in contemporary documentary practice is someone who belongs to a participatory culture in particular. Not only does this mean that those subjects who play a part in a documentary are already informed by their engagement with a range of everyday media practices before the documentary apparatus arrives, the audience for such films are similarly informed and engaged. This audience have their own expectations about how they should be addressed by media producers in general, a fact that feeds back into their expectations about participatory approaches to documentary practice too. It is the ambition of this research to get closer to understanding the relationship between participants in the audience, in documentary and ancillary media texts, as well as behind the camera, and to think about how these relationships constitute a context for the production and reception of documentary films, but also how this context might provide a model for thinking about participatory culture itself. One way that documentary practice and participatory culture converge in this research is in the kind of participatory documentary that I call the ‘Camera Movie’, a narrow mode of documentary filmmaking that appeals directly to contemporary audiences’ desires for innovation and participation, something that is achieved in this case by giving documentary subjects control of the camera. If there is a certain inevitability about this research having to contend with the notion of the ‘participatory documentary’, the ‘participatory camera’ also emerges strongly in this context, especially as a conduit between producer and consumer. Making up the creative component of this research are two documentaries about the reality television event Band In A Bubble, and participatory media practices more broadly. The single-screen film, Hubbub , gives form to the collective intelligence and polyphonous voice of contemporary audiences who must be addressed and solicited in increasingly innovative ways. One More Like That is a split-screen, DVD-Video with alternate audio channels selected by a user who thereby chooses who listens and who speaks in the ongoing conversation between media producers and media consumers. It should be clear from the description above that my own practice does not extend to highly interactive, multi-authored or web-enabled practices, nor the distributed practices one might associate with social media and online collaboration. Mine is fundamentally a single authored, documentary video practice that seeks to analyse and represent participatory culture on screen, and for this reason the Ph.D. refrains from a sustained discussion of the kinds of collaborative practices listed above. This is not to say that such practices don’t also represent an important intersection of documentary practice and participatory culture, they simply represent a different point of intersection. Being practice-led, this research takes its procedural cues from the nature of the practice itself, and sketches parameters that are most enabling of the idea that the practice sets the terms of its own investigation.
Resumo:
Biological tissues are subjected to complex loading states in vivo and in order to define constitutive equations that effectively simulate their mechanical behaviour under these loads, it is necessary to obtain data on the tissue's response to multiaxial loading. Single axis and shear testing of biological tissues is often carried out, but biaxial testing is less common. We sought to design and commission a biaxial compression testing device, capable of obtaining repeatable data for biological samples. The apparatus comprised a sealed stainless steel pressure vessel specifically designed such that a state of hydrostatic compression could be created on the test specimen while simultaneously unloading the sample along one axis with an equilibrating tensile pressure. Thus a state of equibiaxial compression was created perpendicular to the long axis of a rectangular sample. For the purpose of calibration and commissioning of the vessel, rectangular samples of closed cell ethylene vinyl acetate (EVA) foam were tested. Each sample was subjected to repeated loading, and nine separate biaxial experiments were carried out to a maximum pressure of 204 kPa (30 psi), with a relaxation time of two hours between them. Calibration testing demonstrated the force applied to the samples had a maximum error of 0.026 N (0.423% of maximum applied force). Under repeated loading, the foam sample demonstrated lower stiffness during the first load cycle. Following this cycle, an increased stiffness, repeatable response was observed with successive loading. While the experimental protocol was developed for EVA foam, preliminary results on this material suggest that this device may be capable of providing test data for biological tissue samples. The load response of the foam was characteristic of closed cell foams, with consolidation during the early loading cycles, then a repeatable load-displacement response upon repeated loading. The repeatability of the test results demonstrated the ability of the test device to provide reproducible test data and the low experimental error in the force demonstrated the reliability of the test data.
Resumo:
Background: Aerosol production during normal breathing is often attributed to turbulence in the respiratory tract. That mechanism is not consistent with a high degree of asymmetry between aerosol production during inhalation and exhalation. The objective was to investigate production symmetry during breathing. Methods: The aerosol size distribution in exhaled breath was examined for different breathing patterns including normal breathing, varied breath holding periods and contrasting inhalation and exhalation rates. The aerosol droplet size distribution measured in the exhaled breath was examined in real time using an aerodynamic particle sizer. Results and Conclusions: The dependence of the particle concentration decay rate on diameter during breath holding was consistent with gravitational settling in the alveolar spaces. Also, deep exhalation resulted in a 4 to 6 fold increase in concentration and rapid inhalation produced a further 2 to 3 fold increase in concentration. In contrast rapid exhalation had little effect on the measured concentration. A positive correlation of the breath aerosol concentration with subject age was observed. The results were consistent with the breath aerosol being produced through fluid film rupture in the respiratory bronchioles in the early stages of inhalation and the resulting aerosol being drawn into the alveoli and held before exhalation. The observed asymmetry of production in the breathing cycle with very little aerosol being produced during exhalation, is inconsistent with the widely assumed turbulence induced aerosolization mechanism.
Resumo:
Dispersion characteristics of respiratory droplets in indoor environments are of special interest in controlling transmission of airborne diseases. This study adopts an Eulerian method to investigate the spatial concentration distribution and temporal evolution of exhaled and sneezed/coughed droplets within the range of 1.0~10.0μm in an office room with three air distribution methods, i.e. mixing ventilation (MV), displacement ventilation (DV), and under-floor air distribution (UFAD). The diffusion, gravitational settling, and deposition mechanism of particulate matters are well accounted in the one-way coupling Eulerian approach. The simulation results find that exhaled droplets with diameters up to 10.0μm from normal respiration process are uniformly distributed in MV, while they are trapped in the breathing height by thermal stratifications in DV and UFAD, resulting in a high droplet concentration and a high exposure risk to other occupants. Sneezed/coughed droplets are diluted much slower in DV/UFAD than in MV. Low air speed in the breathing zone in DV/UFAD can lead to prolonged residence of droplets in the breathing zone.
Resumo:
The title of this book, Hard Lesson: Reflections on Crime control in Late Modernity, contains a number of clues about its general theoretical direction. It is a book concerned, fist and foremost, with the vagaries of crime control in western neo-liberal and English speaking countries. More specifically, Hard Lessons draws attention to a number of examples in which discrete populations – those who have in one way or another offended against the criminal law - have become the subjects of various forms of stare intervention, regulation and control. We are concerned most of all with the ways in which recent criminal justice policies and practices have resulted in what are variously described as unintended consequences, unforeseen outcomes, unanticipated results, counter-productive effects or negative side effects. At their simplest, such terms refer to the apparent gulf between intention and outcome; they often form the basis for considerable amount of policy reappraisal, soul searching and even nihilistic despair among the mamandirns of crime control. Unintended consequences can, of course, be both positive and negative. Occasionally, crime control measures may result in beneficial outcomes, such as the use of DNA to acquit wrongly convicted prisoners. Generally, however, unforeseen effects tend to be negative and even entirely counterproductive, and/or directly opposite to what were originally intended. All this, of course, presupposes some sort of rational, well meaning and transparent policy making process so beloved by liberal social policy theorists. Yet, as Judith Bessant points out in her chapter, this view of policy formulation tends to obscure the often covert, regulatory and downright malevolent intentions contained in many government policies and practices. Indeed, history is replete with examples of governments seeking to mask their real aims from a prying public eye. Denials and various sorts of ‘techniques of neutralisation’ serve to cloak the real or ‘underlying’ aims of the powerful (Cohen 2000). The latest crop of ‘spin doctors’ and ‘official spokespersons’ has ensured that the process of governmental obfuscation, distortion and concealment remains deeply embedded in neo-liberal forms of governance. There is little new or surprising in this; nor should we be shocked when things ‘go wrong’ in the domain of crime control since many unintended consequences are, more often than not, quite predictable. Prison riots, high rates of recidivism and breaches of supervision orders, expansion rather than contraction of control systems, laws that create the opposite of what was intended – all these are normative features of western crime control. Indeed, without the deep fault lines running between policy and outcome it would be hard to imagine what many policy makers, administrators and practitioners would do: their day to day work practices and (and incomes) are directly dependent upon emergent ‘service delivery’ problems. Despite recurrent howls of official anguish and occasional despondency it is apparent that those involved in the propping up the apparatus of crime control have a vested interest in ensuring that polices and practices remain in an enduring state of review and reform.
Resumo:
Total deposition of petrol, diesel and environmental tobacco smoke (ETS) aerosols in the human respiratory tract for nasal breathing conditions was computed for 14 nonsmoking volunteers, considering the specific anatomical and respiratory parameters of each volunteer and the specific size distribution for each inhalation experiment. Theoretical predictions were 34.6% for petrol, 24.0% for diesel, and 18.5% for ETS particles. Compared to the experimental results, predicted deposition values were consistently smaller than the measured data (41.4% for petrol, 29.6% for diesel, and 36.2% for ETS particles). The apparent discrepancy between experimental data on total deposition and modeling results may be reconciled by considering the non-spherical shape of the test aerosols by diameter-dependent dynamic shape factors to account for differences between mobility-equivalent and volume-equivalent or thermodynamic diameters. While the application of dynamic shape factors is able to explain the observed differences for petrol and diesel particles, additional mechanisms may be required for ETS particle deposition, such as the size reduction upon inspiration by evaporation of volatile compounds and/or condensation-induced restructuring, and, possibly, electrical charge effects.
Resumo:
The MDG deadline is fast approaching and the climate within the United Nations remains positive but skeptical. A common feeling is that a great deal of work and headway has been made, but the MDG goals will not be achieved in full by 2015. The largest problem facing the success of the MDGs is, and unless mitigated may remain, mismanaged governance. This argument is confirmed by a strong line of publications stemming from the United Nations and targeting methods (depending on a region or country context) such as improving governance via combating corruption, instituting accountability, peace and stability, as well as transparency. Furthermore, a logical assessment of the framework which MDGs operate in (i.e. international pressure and local civil socio-economic and/or political initiatives pushing governments to progress with MDGs) identifies the State's governing apparatus as the key to the success of MDGs. It is argued that a new analytic framework and grounded theory of democracy (the Element of Democracy) is needed in order to improve governance and enhance democracy. By looking beyond the confines of the MDGs and focusing on properly rectifying poor governance, the progress of MDGs can be accelerated as societies and their governments will be - at minimum - held more accountable to the success of programs in their respective countries. The paper demonstrates the logic of this argument - especially highlighting a new way of viewing democracy - and certain early practices which can accelerate MDGs in the short to medium term.
Resumo:
The eyelids play an important role in lubricating and protecting the surface of the eye. Each blink serves to spread fresh tears, remove debris and replenish the smooth optical surface of the eye. Yet little is known about how the eyelids contact the ocular surface and what pressure distribution exists between the eyelids and cornea. As the principal refractive component of the eye, the cornea is a major element of the eye’s optics. The optical properties of the cornea are known to be susceptible to the pressure exerted by the eyelids. Abnormal eyelids, due to disease, have altered pressure on the ocular surface due to changes in the shape, thickness or position of the eyelids. Normal eyelids also cause corneal distortions that are most often noticed when they are resting closer to the corneal centre (for example during reading). There were many reports of monocular diplopia after reading due to corneal distortion, but prior to videokeratoscopes these localised changes could not be measured. This thesis has measured the influence of eyelid pressure on the cornea after short-term near tasks and techniques were developed to quantify eyelid pressure and its distribution. The profile of the wave-like eyelid-induced corneal changes and the refractive effects of these distortions were investigated. Corneal topography changes due to both the upper and lower eyelids were measured for four tasks involving two angles of vertical downward gaze (20° and 40°) and two near work tasks (reading and steady fixation). After examining the depth and shape of the corneal changes, conclusions were reached regarding the magnitude and distribution of upper and lower eyelid pressure for these task conditions. The degree of downward gaze appears to alter the upper eyelid pressure on the cornea, with deeper changes occurring after greater angles of downward gaze. Although the lower eyelid was further from the corneal centre in large angles of downward gaze, its effect on the cornea was greater than that of the upper eyelid. Eyelid tilt, curvature, and position were found to be influential in the magnitude of eyelid-induced corneal changes. Refractively these corneal changes are clinically and optically significant with mean spherical and astigmatic changes of about 0.25 D after only 15 minutes of downward gaze (40° reading and steady fixation conditions). Due to the magnitude of these changes, eyelid pressure in downward gaze offers a possible explanation for some of the day-to-day variation observed in refraction. Considering the magnitude of these changes and previous work on their regression, it is recommended that sustained tasks performed in downward gaze should be avoided for at least 30 minutes before corneal and refractive assessment requiring high accuracy. Novel procedures were developed to use a thin (0.17 mm) tactile piezoresistive pressure sensor mounted on a rigid contact lens to measure eyelid pressure. A hydrostatic calibration system was constructed to convert raw digital output of the sensors to actual pressure units. Conditioning the sensor prior to use regulated the measurement response and sensor output was found to stabilise about 10 seconds after loading. The influences of various external factors on sensor output were studied. While the sensor output drifted slightly over several hours, it was not significant over the measurement time of 30 seconds used for eyelid pressure, as long as the length of the calibration and measurement recordings were matched. The error associated with calibrating at room temperature but measuring at ocular surface temperature led to a very small overestimation of pressure. To optimally position the sensor-contact lens combination under the eyelid margin, an in vivo measurement apparatus was constructed. Using this system, eyelid pressure increases were observed when the upper eyelid was placed on the sensor and a significant increase was apparent when the eyelid pressure was increased by pulling the upper eyelid tighter against the eye. For a group of young adult subjects, upper eyelid pressure was measured using this piezoresistive sensor system. Three models of contact between the eyelid and ocular surface were used to calibrate the pressure readings. The first model assumed contact between the eyelid and pressure sensor over more than the pressure cell width of 1.14 mm. Using thin pressure sensitive carbon paper placed under the eyelid, a contact imprint was measured and this width used for the second model of contact. Lastly as Marx’s line has been implicated as the region of contact with the ocular surface, its width was measured and used as the region of contact for the third model. The mean eyelid pressures calculated using these three models for the group of young subjects were 3.8 ± 0.7 mmHg (whole cell), 8.0 ± 3.4 mmHg (imprint width) and 55 ± 26 mmHg (Marx’s line). The carbon imprints using Pressurex-micro confirmed previous suggestions that a band of the eyelid margin has primary contact with the ocular surface and provided the best estimate of the contact region and hence eyelid pressure. Although it is difficult to directly compare the results with previous eyelid pressure measurement attempts, the eyelid pressure calculated using this model was slightly higher than previous manometer measurements but showed good agreement with the eyelid force estimated using an eyelid tensiometer. The work described in this thesis has shown that the eyelids have a significant influence on corneal shape, even after short-term tasks (15 minutes). Instrumentation was developed using piezoresistive sensors to measure eyelid pressure. Measurements for the upper eyelid combined with estimates of the contact region between the cornea and the eyelid enabled quantification of the upper eyelid pressure for a group of young adult subjects. These techniques will allow further investigation of the interaction between the eyelids and the surface of the eye.
Resumo:
Purpose: The cornea is known to be susceptible to forces exerted by eyelids. There have been previous attempts to quantify eyelid pressure but the reliability of the results is unclear. The purpose of this study was to develop a technique using piezoresistive pressure sensors to measure upper eyelid pressure on the cornea. Methods: The technique was based on the use of thin (0.18 mm) tactile piezoresistive pressure sensors, which generate a signal related to the applied pressure. A range of factors that influence the response of this pressure sensor were investigated along with the optimal method of placing the sensor in the eye. Results: Curvature of the pressure sensor was found to impart force, so the sensor needed to remain flat during measurements. A large rigid contact lens was designed to have a flat region to which the sensor was attached. To stabilise the contact lens during measurement, an apparatus was designed to hold and position the sensor and contact lens combination on the eye. A calibration system was designed to apply even pressure to the sensor when attached to the contact lens, so the raw digital output could be converted to actual pressure units. Conclusions: Several novel procedures were developed to use tactile sensors to measure eyelid pressure. The quantification of eyelid pressure has a number of applications including eyelid reconstructive surgery and the design of soft and rigid contact lenses.
Resumo:
In a much anticipated judgment, the Federal Circuit has sought to clarify the standards applicable in determining whether a claimed method constitutes patent-eligible subject matter. In Bilski, the Federal Circuit identified a test to determine whether a patentee has made claims that pre-empt the use of a fundamental principle or an abstract idea or whether those claims cover only a particular application of a fundamental principle or abstract idea. It held that the sole test for determining subject matter eligibility for a claimed process under § 101 is that: (1) it is tied to a particular machine or apparatus, or (2) it transforms a particular article into a different state or thing. The court termed this the “machine-or-transformation test.” In so doing it overruled its earlier State Street decision to the extent that it deemed its “useful, tangible and concrete result” test as inadequate to determine whether an alleged invention recites patent-eligible subject matter.