618 resultados para Balloon


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Acute urinary retention is a common emergency condition in elderly men. Transurethral and suprapubic catheterization are easy and safe procedures provided that a few simple rules are followed. Primarily, a transurethral catheter is placed if there is no urethral injury or stricture. Local anaesthesia of the urethra up to the sphincter region and a well-stretched penis warrant an atraumatic insertion of the catheter into the bladder. The use of a thick catheter with a round tip or of a catheter with a bended tip under rectal guidance facilitate the insertion of the catheter in difficult conditions. Alternatively, a suprapubic catheterization can be performed provided that no contraindication such as history or suspicion of transitional cell carcinoma is present. Optimal interventional conditions using ultrasound-guidance are mandatory in patients after abdominal surgery and with hemorrhagic diathesis in view of a safe and straight-forward placement of the suprapubic catheterization. In case of persistent bleeding after insertion of a suprapubic catheter, the suprapubic catheter should be replaced by one with a balloon blocked and kept under tension for several minutes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND Access to care may be implicated in disparities between men and women in death after acute coronary syndrome, especially among younger adults. We aimed to assess sex-related differences in access to care among patients with premature acute coronary syndrome and to identify clinical and gender-related determinants of access to care. METHODS We studied 1123 patients (18-55 yr) admitted to hospital for acute coronary syndrome and enrolled in the GENESIS-PRAXY cohort study. Outcome measures were door-to-electrocardiography, door-to-needle and door-to-balloon times, as well as proportions of patients undergoing cardiac catheterization, reperfusion or nonprimary percutaneous coronary intervention. We performed univariable and multivariable logistic regression analyses to identify clinical and gender-related determinants of timely procedures and use of invasive procedures. RESULTS Women were less likely than men to receive care within benchmark times for electrocardiography (≤ 10 min: 29% v. 38%, p = 0.02) or fibrinolysis (≤ 30 min: 32% v. 57%, p = 0.01). Women with ST-segment elevation myocardial infarction (MI) were less likely than men to undergo reperfusion therapy (primary percutaneous coronary intervention or fibrinolysis) (83% v. 91%, p = 0.01), and women with non-ST-segment elevation MI or unstable angina were less likely to undergo nonprimary percutaneous coronary intervention (48% v. 66%, p < 0.001). Clinical determinants of poorer access to care included anxiety, increased number of risk factors and absence of chest pain. Gender-related determinants included feminine traits of personality and responsibility for housework. INTERPRETATION Among younger adults with acute coronary syndrome, women and men had different access to care. Moreover, fewer than half of men and women with ST-segment elevation MI received timely primary coronary intervention. Our results also highlight that men and women with no chest pain and those with anxiety, several traditional risk factors and feminine personality traits were at particularly increased risk of poorer access to care.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Portal vein embolization (PVE) may be performed before hemihepatectomy to increase the volume of future liver remnant (FLR) and to reduce the risk of postoperative liver insufficiency. We report the case of a 71-year-old patient with hilar cholangiocarcinoma undergoing PVE with access from the right portal vein using a mixture of n-butyl-2-cyanoacrylate and ethiodized oil. During the procedure, nontarget embolization of the left portal vein occurred. An aspiration maneuver of the polymerized plug failed; however, the embolus obstructing portal venous flow in the FLR was successfully relocated into the right portal vein while carefully bypassing the plug with a balloon catheter, inflating the balloon, and pulling the plug into the main right portal vein.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION Diagnostic tools to show emboli reliably and protection techniques against embolization when employing stent retrievers are necessary to improve endovascular stroke therapy. The aim of the present study was to investigate iatrogenic emboli using susceptibility-weighted imaging (SWI) in an open series of patients who had been treated with stent retriever thrombectomy using emboli protection techniques. METHODS Patients with anterior circulation stroke examined with MRI before and after stent retriever thrombectomy were assessed for iatrogenic embolic events. Thrombectomy was performed in flow arrest and under aspiration using a balloon-mounted guiding catheter, a distal access catheter, or both. RESULTS In 13 of 57 patients (22.8 %) post-interventional SWI sequences detected 16 microemboli. Three of them were associated with small ischemic lesions on diffusion-weighted imaging (DWI). None of the microemboli were located in a new vascular territory, none showed clinical signs, and all 13 patients have been rated as Thrombolysis in Cerebral Infarction (TICI) 2b (n = 3) or 3 (n = 10). Retrospective reevaluation of the digital subtraction angiography (DSA) detected discrete flow stagnation nearby the iatrogenic microemboli in four patients with a positive persistent collateral sign in one. CONCLUSION Our study demonstrates two things: First, SWI seems to be more sensitive to detect emboli than DWI and DSA and, second, proximal or distal protected stent retriever thrombectomy seems to prevent iatrogenic embolization into new vascular territories during retraction of the thrombus, but not downstream during mobilization of the thrombus. Both techniques should be investigated and refined further.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND Previous analyses reported age- and gender-related differences in the provision of cardiac care. The objective of the study was to compare circadian disparities in the delivery of primary percutaneous coronary intervention (PCI) for acute myocardial infarction (AMI) according to the patient's age and gender. METHODS We investigated patients included into the Acute Myocardial Infarction in Switzerland (AMIS) registry presenting to one of 11 centers in Switzerland providing primary PCI around the clock, and stratified patients according to gender and age. FINDINGS A total of 4723 patients presented with AMI between 2005 and 2010; 1319 (28%) were women and 2172 (54%) were ≥65 years of age. More than 90% of patients <65 years of age underwent primary PCI without differences between gender. Elderly patients and particularly women were at increased risk of being withheld primary PCI (males adj. HR 4.91, 95% CI 3.93-6.13; females adj. HR 9.31, 95% CI 7.37-11.75) as compared to males <65 years of age. An increased risk of a delay in door-to-balloon time >90 minutes was found in elderly males (adj HR 1.66 (95% CI 1.40-1.95), p<0.001) and females (adj HR 1.57 (95% CI 1.27-1.93), p<0.001), as well as in females <65 years (adj HR 1.47 (95% CI 1.13-1.91), p = 0.004) as compared to males <65 years of age, with significant differences in circadian patterns during on- and off-duty hours. CONCLUSIONS In a cohort of patients with AMI in Switzerland, we observed discrimination of elderly patients and females in the circadian provision of primary PCI.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND New generation transcatheter heart valves (THV) may improve clinical outcomes of transcatheter aortic valve implantation. METHODS AND RESULTS In a nationwide, prospective, multicenter cohort study (Swiss Transcatheter Aortic Valve Implantation Registry, NCT01368250), outcomes of consecutive transfemoral transcatheter aortic valve implantation patients treated with the Sapien 3 THV (S3) versus the Sapien XT THV (XT) were investigated. An overall of 153 consecutive S3 patients were compared with 445 consecutive XT patients. Postprocedural mean transprosthetic gradient (6.5±3.0 versus 7.8±6.3 mm Hg, P=0.17) did not differ between S3 and XT patients, respectively. The rate of more than mild paravalvular regurgitation (1.3% versus 5.3%, P=0.04) and of vascular (5.3% versus 16.9%, P<0.01) complications were significantly lower in S3 patients. A higher rate of new permanent pacemaker implantations was observed in patients receiving the S3 valve (17.0% versus 11.0%, P=0.01). There were no significant differences for disabling stroke (S3 1.3% versus XT 3.1%, P=0.29) and all-cause mortality (S3 3.3% versus XT 4.5%, P=0.27). CONCLUSIONS The use of the new generation S3 balloon-expandable THV reduced the risk of more than mild paravalvular regurgitation and vascular complications but was associated with an increased permanent pacemaker rate compared with the XT. Transcatheter aortic valve implantation using the newest generation balloon-expandable THV is associated with a low risk of stroke and favorable clinical outcomes. CLINICAL TRIAL REGISTRATION URL: http://www.clinicaltrials.gov. Unique identifier: NCT01368250.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND Percutaneous coronary intervention (PCI) with drug-eluting stents is the standard of care for treatment of native coronary artery stenoses, but optimum treatment strategies for bare metal stent and drug-eluting stent in-stent restenosis (ISR) have not been established. We aimed to compare and rank percutaneous treatment strategies for ISR. METHODS We did a network meta-analysis to synthesise both direct and indirect evidence from relevant trials. We searched PubMed, the Cochrane Library Central Register of Controlled Trials, and Embase for randomised controlled trials published up to Oct 31, 2014, of different PCI strategies for treatment of any type of coronary ISR. The primary outcome was percent diameter stenosis at angiographic follow-up. This study is registered with PROSPERO, number CRD42014014191. FINDINGS We deemed 27 trials eligible, including 5923 patients, with follow-up ranging from 6 months to 60 months after the index intervention. Angiographic follow-up was available for 4975 (84%) of 5923 patients 6-12 months after the intervention. PCI with everolimus-eluting stents was the most effective treatment for percent diameter stenosis, with a difference of -9·0% (95% CI -15·8 to -2·2) versus drug-coated balloons (DCB), -9·4% (-17·4 to -1·4) versus sirolimus-eluting stents, -10·2% (-18·4 to -2·0) versus paclitaxel-eluting stents, -19·2% (-28·2 to -10·4) versus vascular brachytherapy, -23·4% (-36·2 to -10·8) versus bare metal stents, -24·2% (-32·2 to -16·4) versus balloon angioplasty, and -31·8% (-44·8 to -18·6) versus rotablation. DCB were ranked as the second most effective treatment, but without significant differences from sirolimus-eluting (-0·2% [95% CI -6·2 to 5·6]) or paclitaxel-eluting (-1·2% [-6·4 to 4·2]) stents. INTERPRETATION These findings suggest that two strategies should be considered for treatment of any type of coronary ISR: PCI with everolimus-eluting stents because of the best angiographic and clinical outcomes, and DCB because of its ability to provide favourable results without adding a new stent layer. FUNDING None.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The first operations at the new High-altitude Maïdo Observatory at La Réunion began in 2013. The Maïdo Lidar Calibration Campaign (MALICCA) was organized there in April 2013 and has focused on the validation of the thermodynamic parameters (temperature, water vapor, and wind) measured with many instruments including the new very large lidar for water vapor and temperature profiles. The aim of this publication consists of providing an overview of the different instruments deployed during this campaign and their status, some of the targeted scientific questions and associated instrumental issues. Some specific detailed studies for some individual techniques were addressed elsewhere. This study shows that temperature profiles were obtained from the ground to the mesopause (80 km) thanks to the lidar and regular meteorological balloon-borne sondes with an overlap range showing good agreement. Water vapor is also monitored from the ground to the mesopause by using the Raman lidar and microwave techniques. Both techniques need to be pushed to their limit to reduce the missing range in the lower stratosphere. Total columns obtained from global positioning system or spectrometers are valuable for checking the calibration and ensuring vertical continuity. The lidar can also provide the vertical cloud structure that is a valuable complementary piece of information when investigating the water vapor cycle. Finally, wind vertical profiles, which were obtained from sondes, are now also retrieved at Maïdo from the newly implemented microwave technique and the lidar. Stable calibrations as well as a small-scale dynamical structure are required to monitor the thermodynamic state of the middle atmosphere, ensure validation of satellite sensors, study the transport of water vapor in the vicinity of the tropical tropopause and study their link with cirrus clouds and cyclones and the impact of small-scale dynamics (gravity waves) and their link with the mean state of the mesosphere.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The joint European Society of Cardiology and European Association of Cardio-Thoracic Surgery (ESC/EACTS) guidelines on myocardial revascularization collect and summarize the evidence regarding decision-making, diagnostics, and therapeutics in various clinical scenarios of coronary artery disease, including elective, urgent, and emergency settings. The 2014 document updates and extends the effort started in 2010, year of the first edition of these guidelines. Importantly, this latest edition provides a systematic review of all randomized clinical trials performed since 1980, comparing different strategies of myocardial revascularization, including coronary artery bypass graft (CABG), balloon angioplasty, percutaneous coronary intervention (PCI) with bare-metal stents (BMS) and first- and second-generation drug-eluting stents (DES). This review aims to highlight the most relevant novelties introduced by the 2014 edition of the ESC/EACTS myocardial revascularization guidelines as compared with the previous edition and to describe similarities and differences with the American societies' guidelines.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES The SOURCE XT Registry (Edwards SAPIEN XT Aortic Bioprosthesis Multi-Region Outcome Registry) assessed the use and clinical outcomes with the SAPIEN XT (Edwards Lifesciences, Irvine, California) valve in the real-world setting. BACKGROUND Transcatheter aortic valve replacement is an established treatment for high-risk/inoperable patients with severe aortic stenosis. The SAPIEN XT is a balloon-expandable valve with enhanced features allowing delivery via a lower profile sheath. METHODS The SOURCE XT Registry is a prospective, multicenter, post-approval study. Data from 2,688 patients at 99 sites were analyzed. The main outcome measures were all-cause mortality, stroke, major vascular complications, bleeding, and pacemaker implantations at 30-days and 1 year post-procedure. RESULTS The mean age was 81.4 ± 6.6 years, 42.3% were male, and the mean logistic EuroSCORE (European System for Cardiac Operative Risk Evaluation) was 20.4 ± 12.4%. Patients had a high burden of coronary disease (44.2%), diabetes (29.4%), renal insufficiency (28.9%), atrial fibrillation (25.6%), and peripheral vascular disease (21.2%). Survival was 93.7% at 30 days and 80.6% at 1 year. At 30-day follow-up, the stroke rate was 3.6%, the rate of major vascular complications was 6.5%, the rate of life-threatening bleeding was 5.5%, the rate of new pacemakers was 9.5%, and the rate of moderate/severe paravalvular leak was 5.5%. Multivariable analysis identified nontransfemoral approach (hazard ratio [HR]: 1.84; p < 0.0001), renal insufficiency (HR: 1.53; p < 0.0001), liver disease (HR: 1.67; p = 0.0453), moderate/severe tricuspid regurgitation (HR: 1.47; p = 0.0019), porcelain aorta (HR: 1.47; p = 0.0352), and atrial fibrillation (HR: 1.41; p = 0.0014), with the highest HRs for 1-year mortality. Major vascular complications and major/life-threatening bleeding were the most frequently seen complications associated with a significant increase in 1-year mortality. CONCLUSIONS The SOURCE XT Registry demonstrated appropriate use of the SAPIEN XT THV in the first year post-commercialization in Europe. The safety profile is sustained, and clinical benefits have been established in the real-world setting. (SOURCE XT Registry; NCT01238497).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE Vertebroplasty and balloon kyphoplasty are effective treatment options for osteoporotic vertebral compression fractures but are limited in correction of kyphotic deformity. Lordoplasty has been reported as an alternative, cost-effective, minimally invasive, percutaneous cement augmentation technique with good restoration of vertebral body height and alignment. The authors report on its clinical and radiological midterm results. METHODS A retrospective review was conducted of patients treated with lordoplasty from 2002 to 2014. Inclusion criteria were clinical and radiological follow-up evaluations longer than 24 months. Radiographs were accessed regarding initial correction and progressive loss of reduction. Complications and reoperations were recorded. Actual pain level, pain relief immediately after surgery, autonomy, and subjective impression of improvement of posture were assessed by questionnaire. RESULTS Sixty-five patients (46 women, 19 men, age range 38.9-86.2 years old) were treated with lordoplasty for 69 vertebral compression and insufficiency fractures. A significant correction of the vertebral kyphotic angle (mean 13°) and segmental kyphotic angle (mean 11°) over a mean follow-up of 33 months (range 24-108 months) was achieved (p < 0.001). On average, pain was relieved to 90% of the initial pain level. In 24% of the 65 patients a second spinal intervention was necessary: 16 distant (24.6%) and 7 adjacent (10.8%) new osteoporotic fractures, 4 instrumented stabilizations (6.2%), 1 new adjacent traumatic fracture (1.5%), and 1 distant microsurgical decompression (1.5%). Cement leakage occurred in 10.4% but was only symptomatic in 1 case. CONCLUSIONS Lordoplasty appeared safe and effective in midterm pain alleviation and restoration of kyphotic deformity in osteoporotic compression and insufficiency fractures. The outcomes of lordoplasty are consistent with other augmentation techniques.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE Recent small single-center data indicate that the current hemodynamic parameters used to diagnose critical limb ischemia are insensitive. We investigated the validity of the societal guidelines-recommended hemodynamic parameters against core laboratory-adjudicated angiographic data from the multicenter IN.PACT DEEP (RandomIzed AmPhirion DEEP DEB vs StAndard PTA for the treatment of below the knee Critical limb ischemia) Trial. METHODS Of the 358 patients in the IN.PACT DEEP Trial to assess drug-eluting balloon vs standard balloon angioplasty for infrapopliteal disease, 237 had isolated infrapopliteal disease with an available ankle-brachial index (ABI), and only 40 of the latter had available toe pressure measurements. The associations between ABI, ankle pressure, and toe pressure with tibial runoff, Rutherford category, and plantar arch were examined according to the cutoff points recommended by the societal guidelines. Abnormal tibial runoff was defined as severely stenotic (≥70%) or occluded and scored as one-, two-, or three-vessel disease. A stenotic or occluded plantar arch was considered abnormal. RESULTS Only 14 of 237 patients (6%) had an ABI <0.4. Abnormal ankle pressure, defined as <50 mm Hg if Rutherford category 4 and <70 mm Hg if Rutherford category 5 or 6, was found only in 37 patients (16%). Abnormal toe pressure, defined as <30 mm Hg if Rutherford category 4 and <50 mm Hg if Rutherford category 5 or 6, was found in 24 of 40 patients (60%) with available measurements. Importantly, 29% of these 24 patients had an ABI within normal reference ranges. A univariate multinomial logistic regression found no association between the above hemodynamic parameters and the number of diseased infrapopliteal vessels. However, there was a significant paradoxic association where patients with Rutherford category 6 had higher ABI and ankle pressure than those with Rutherford category 5. Similarly, there was no association between ABI and pedal arch patency. CONCLUSIONS The current recommended hemodynamic parameters fail to identify a significant portion of patients with lower extremity ulcers and angiographically proven severe disease. Toe pressure has better sensitivity and should be considered in all patients with critical limb ischemia.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

"Technology assessment is a comprehensive form of policy research that examines the short- and long-term social consequences of the application or use of technology" (US Congress 1967).^ This study explored a research methodology appropriate for technology assessment (TA) within the health industry. The case studied was utilization of external Small-Volume Infusion Pumps (SVIP) at a cancer treatment and research center. Primary and secondary data were collected in three project phases. In Phase I, hospital prescription records (N = 14,979) represented SVIP adoption and utilization for the years 1982-1984. The Candidate Adoption-Use (CA-U) diffusion paradigm developed for this study was germane. Compared to classic and unorthodox curves, CA-U more accurately simulated empiric experience. The hospital SVIP 1983-1984 trends denoted assurance in prescribing chemotherapy and concomitant balloon SVIP efficacy and efficiency. Abandonment of battery pumps was predicted while exponential demand for balloon SVIP was forecast for 1985-1987. In Phase II, patients using SVIP (N = 117) were prospectively surveyed from July to October 1984; the data represented a single episode of therapy. The questionnaire and indices, specifically designed to measure the impact of SVIP, evinced face validity. Compeer group data were from pre-SVIP case reviews rather than from an inpatient sample. Statistically significant results indicated that outpatients using SVIP interacted socially more than inpatients using the alternative technology. Additionally, the hospital's education program effectively taught clients to discriminate between self care and professional SVIP services. In these contexts, there was sufficient evidence that the alternative technology restricted patients activity whereas SVIP permitted patients to function more independently and in a social lifestyle, thus adding quality to life. In Phase III, diffusion forecast and patient survey findings were combined with direct observation of clinic services to profile some economic dimensions of SVIP. These three project phases provide a foundation for executing: (1) cost effectiveness analysis of external versus internal infusors, (2) institutional resource allocation, and (3) technology deployment to epidemiology-significant communities. The models and methods tested in this research of clinical technology assessment are innovative and do assess biotechnology. ^