918 resultados para Auditing of computer systems


Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Doppler Optical Coherence Tomography (DOCT) is a biomedical imaging technique that allows simultaneous structural imaging and flow monitoring inside biological tissues and materials with spatial resolution in the micrometer scale. It has recently been applied to the characterization of microfluidic systems. Structural and flow imaging of novel microfluidics platforms for cytotoxicologic applications were obtained with a real-time, Near Infrared Spectral Domain DOCT system. Characteristics such as flow homogeneity in the chamber, which is one of the most important parameters for cell culture, are investigated. OCT and DOCT images were used to monitor flow inside a specific platform that is based on microchannel division for a better flow homogeneity. In particular, the evolution of flow profile at the transition between the microchannel structure and the chamber is studied.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Utilisation of sorting systems’ maximum performance demands continuous conveying of goods by infeed lines to sorters. This is the case especially for sorters with one single infeed line, because the sorters’ performance is limited by the performance of the infeed line. Within this paper different infeed line constructions at the Rotary Sorter with diverse performances will be presented. The focus lies on a specific conveying system to synchronise the goods with the sorter by a performance of 6000 pieces per hour with one dynamic infeed line. By this means there is no extensive adjustment control of serial conveyors in the infeed line any longer.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In recent years, the ability to respond to real time changes in operations and reconfigurability in equipment are likely to become essential characteristics for next generation intralogistics systems as well as the level of automation, cost effectiveness and maximum throughput. In order to cope with turbulences and the increasing level of dynamic conditions, future intralogistics systems have to feature short reaction times, high flexibility in processes and the ability to adapt to frequent changes. The increasing autonomy and complexity in processes of today’s intralogistics systems requires new and innovative management approaches, which allow a fast response to (un)anticipated events and adaptation to changing environment in order to reduce the negative consequences of these events. The ability of a system to respond effectively a disruption depends more on the decisions taken before the event than those taken during or after. In this context, anticipatory change planning can be a usable approach for managers to make contingency plans for intralogistics systems to deal with the rapidly changing marketplace. This paper proposes a simulation-based decision making framework for the anticipatory change planning of intralogistics systems. This approach includes the quantitative assessments based on the simulation in defined scenarios as well as the analysis of performance availability that combines the flexibility corridors of different performance dimensions. The implementation of the approach is illustrated on a new intralogistics technology called the Cellular Transport System.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This progress report is an introduction to a study to evaluate the incorporation of rotational pasturing systems into cattle finishing programs. Because the first year is still in progress and the first trial is not complete, few data are available. However, there is a suggestion that feeding an ionophore to young calves on pasture may result in improved daily gains.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A 3-year study, using 84 fall-born and 28 spring-born calves of similar genotypes, was conducted to integrate pasturing systems with drylot feeding systems. Calves were started on test following weaning in May and October. Seven treatments were imposed: 1) fall-born calves directly into feedlot; 2 and 3) fall-born calves put on pasture with or without ionophore and moved to the feedlot at the end of July; 4 and 5) fall-born calves put on pasture with or without ionophore and moved to the feedlot at the end of October; 6 and 7) spring-born calves put on pasture with or without ionophore and moved to the feedlot at the end of October. A bromegrass pasture consisting of 16 paddocks, each 1.7 acre in size, was available. Each treatment group had access to 1 paddock at a time and was rotated at approximately 3-day intervals. In the feedlot, steers were provided an 82% concentrate diet containing whole-shelled corn, ground alfalfa hay, and a protein, vitamin and mineral supplement containing ionophore and molasses. As pens of cattle reached about 1150 lb. average live weight, they were processed and carcass traits were evaluated. Pasture daily gains were highest for cattle on pasture for the longest duration (P < .03), and overall daily gains were highest for drylot cattle (P < .01) and decreased with increased time spent on pasture. Although differences among treatments existed in numerical scores for yield and quality grades (P < .05 and P < .03, respectively), all treatments provided average yield grade scores of 2 and quality grades of low Choice or higher. Use of four production costs and pricing scenarios revealed that fall-born calves placed on pasture for varying lengths of time were the most profitable (P < .04) among the treatments. Furthermore, employing a 5% price sensitivity analysis, indicated that fed-cattle selling price had great impact on profit potential and was followed in importance by feeder purchase price and corn grain price. Overall, these findings should provide significant production alternatives for some segments of the cattle feeding industry and also lend substantial credence to the concept of sustainable agriculture.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A three-year study was conducted to integrate pasturing systems with drylot feeding systems. Each year 84 fall-born and 28 spring-born calves of similar genotypes were used. Fall-born calves were started on test in May, and spring-born calves were started in October. Seven treatments were imposed: 1) fall-born calves directly into the feedlot (28 steers); 2 and 3) fall-born calves put on pasture with or without an ionophore and moved to the feedlot at the end of July (14 steers in each treatment); 4 and 5) fall-born calves put on pasture with or without an ionophore and moved to the feedlot at the end of October (14 steers in each treatment); and 6 and 7) spring-born calves put on pasture with or without an ionophore and moved to the feedlot at the end of October (14 steers in each treatment). Cattle on pasture receiving an ionophore gained faster (P=.009), but lost this advantage in drylot (P>.10). Overall, cattle started directly in the feedlot had higher gains (P<.001). Cattle receiving an ionophore on pasture had lower KPH than those that did not receive an ionophore (P<.01). Treatment influenced yield grade (P<0.001), although all treatments were YG 2. The percentage of cattle grading Prime and Choice was 75 % or higher for all treatment groups. The results show that using an ionophore improved pasture gains and that pasture treatments did not adversely influence yield and quality grades.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This progress report presents the findings of the first two years of a multi-year study. Each year 84 fall-born and 28 spring-born calves of similar genetic background were used to evaluate the incorporation of rotational pasturing systems into cattle finishing programs. The fall-born calves were started on test on May 7, 1996, and May 8, 1997, whereas the spring-born calves were started on test on October 1, 1996, and September 13, 1997. A total of seven treatments were imposed: 1) fall-born calves directly into the feedlot; 2) fall-born calves put on pasture and receiving an ionophore and moved to the feedlot on July 30, 1996, and July 29, 1997 in the first and second years, respectively; 3) fall-born calves put on pasture without an ionophore and moved to the feedlot on July 30, 1996 and July 29, 1997, in the first and second years, respectively; 4) fall-born calves put on pasture and receiving an ionophore and moved to the feedlot on October 22, 1996, and October 21, 1997, in the first and second years, respectively; 5) fall-born calves put on pasture without an ionophore and moved to the feedlot on October 22, 1996, and October 21, 1997, in the first and second years, respectively; 6) spring-born calves put on pasture and receiving an ionophore and moved to the feedlot on October 22, 1996, and October 21, 1997, in the first and second years, respectively; and 7) spring-born calves put on pasture without an ionophore and moved to the feedlot on October 22, 1996, and October 21, 1997, in the first and second years, respectively. Cattle receiving an ionophore on pasture gained more rapidly; however, cattle without access to an ionophore gained more rapidly in drylot thus negating the advantage obtained on pasture. Overall daily gains and feed conversions in drylot only, improved with increasing numbers of days fed in drylot; however, this may not be very cost effective. At similar end weights no real differences were observed in yield grades among the treatments; however, for fall-born calves the percentage grading Prime and Choice was higher for cattle fed longer in drylot.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this study, 84 fall-born and 28 spring-born calves of similar genetic background were used to evaluate the incorporation of rotational pasturing systems into cattle finishing programs. Because the second-year trial is not complete, this report will include only the first year of the five-year study. Seven treatments were imposed: 1) fall-born calves put directly into the feedlot on May 7, 1996; 2) fall-born calves put on pasture and receiving an ionophore and moved to the feedlot on July 30, 3) fall born calves put on pasture on May 7 and not receiving an ionophore and moved to the feedlot on July 30; 4) fall-born calves put on pasture on May 7 and receiving an ionophore and moved to the feedlot on October 22; 5) fall-born calves put on pasture on May 7 and not receiving an ionophore and moved to the feedlot on October 22; 6) spring-born calves put on pasture on October 1 and receiving an ionophore and moved to the feedlot on October 22; and 7) spring-born calves put on pasture on October 1 and not receiving an ionophore and moved to feedlot on October 22. Performance data showed that cattle on pasture receiving an ionophore had higher gains than those not receiving an ionophore on pasture. This trend was reversed in the feedlot period. Yield grades were not greatly influenced by treatment, although quality grades tended to be higher for older cattle and those cattle that were in drylot for a longer period of time.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES Optical scanners combined with computer-aided design and computer-aided manufacturing (CAD/CAM) technology provide high accuracy in the fabrication of titanium (TIT) and zirconium dioxide (ZrO) bars. The aim of this study was to compare the precision of fit of CAD/CAM TIT bars produced with a photogrammetric and a laser scanner. METHODS Twenty rigid CAD/CAM bars were fabricated on one single edentulous master cast with 6 implants in the positions of the second premolars, canines and central incisors. A photogrammetric scanner (P) provided digitized data for TIT-P (n=5) while a laser scanner (L) was used for TIT-L (n=5). The control groups consisted of soldered gold bars (gold, n=5) and ZrO-P with similar bar design. Median vertical distance between implant and bar platforms from non-tightened implants (one-screw test) was calculated from mesial, buccal and distal scanning electron microscope measurements. RESULTS Vertical microgaps were not significantly different between TIT-P (median 16μm; 95% CI 10-27μm) and TIT-L (25μm; 13-32μm). Gold (49μm; 12-69μm) had higher values than TIT-P (p=0.001) and TIT-L (p=0.008), while ZrO-P (35μm; 17-55μm) exhibited higher values than TIT-P (p=0.023). Misfit values increased in all groups from implant position 23 (3 units) to 15 (10 units), while in gold and TIT-P values decreased from implant 11 toward the most distal implant 15. SIGNIFICANCE CAD/CAM titanium bars showed high precision of fit using photogrammetric and laser scanners. In comparison, the misfit of ZrO bars (CAM/CAM, photogrammetric scanner) and soldered gold bars was statistically higher but values were clinically acceptable.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES The study investigated the modification of composite-to-enamel bond strength by pre-treatment of enamel with a concentrated, acidic SnCl2-solution. METHODS Six groups of flat human enamel specimens (n=44 per group) were treated as follows: OB-H: H3PO4 etching, Optibond FL application (primer+adhesive; manufacturer's instructions); OB-S: SnCl2 pre-treatment, Optibond FL application (primer+adhesive); OB-HS: H3PO4 etching+SnCl2 pre-treatment, Optibond FL application (primer+adhesive); CF-N: Clearfil SE application (primer+bond; manufacturer's instructions); CF-H: H3PO4 etching, Clearfil SE application (primer+bond); CF-S: SnCl2 pre-treatment, Clearfil SE application (primer+bond). Enamel specimens were then built up with resin composite (Clearfil Majesty Esthetic) and stored (100% humidity, 37 °C, 1 week). μTBS-measurement and failure mode analysis of one-half of the specimens were performed immediately after storage, while the other half was analysed after a thermocycling procedure (8500 cycles; 5 °C and 55 °C; dwell time 30s). Additional specimens were prepared for SEM- and EDX-analysis. RESULTS Highest values were measured for OB-H before and after thermocycling, lowest values for CF-N. Compared to OB-H treatment, OB-S treatment reduced μTBS before/after thermocycling by 23%/28% and OB-HS treatment by 8%/24% (except for OB-SH before (n.s.), all p≤0.001 compared to OB-H). In the Clearfil SE treated groups pre-treatment increased μTBS significantly compared to CF-N (before/after: CF-H: +46%/+70%; CF-S: +51%/42%; all p≤0.001). CONCLUSION Pre-treatment with H3PO4 or SnCl2 markedly increased the μTBS of Clearfil SE to enamel. However, thermocycling partly reduced the gain in μTBS obtained by SnCl2 pre-treatment. CLINICAL SIGNIFICANCE The application of an acidic and highly concentrated SnCl2 solution is a good option to increase the μTBS between enamel and a resin composite mediated by an adhesive system containing the multifunctional monomer MDP.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE To compare the precision of fit of full-arch implant-supported screw-retained computer-aided designed and computer-aided manufactured (CAD/CAM) titanium-fixed dental prostheses (FDP) before and after veneering. The null-hypothesis was that there is no difference in vertical microgap values between pure titanium frameworks and FDPs after porcelain firing. MATERIALS AND METHODS Five CAD/CAM titanium grade IV frameworks for a screw-retained 10-unit implant-supported reconstruction on six implants (FDI tooth positions 15, 13, 11, 21, 23, 25) were fabricated after digitizing the implant platforms and the cuspid-supporting framework resin pattern with a laser scanner (CARES(®) Scan CS2; Institut Straumann AG, Basel, Switzerland). A bonder, an opaquer, three layers of porcelain, and one layer of glaze were applied (Vita Titankeramik) and fired according to the manufacturer's preheating and fire cycle instructions at 400-800°C. The one-screw test (implant 25 screw-retained) was applied before and after veneering of the FDPs to assess the vertical microgap between implant and framework platform with a scanning electron microscope. The mean microgap was calculated from interproximal and buccal values. Statistical comparison was performed with non-parametric tests. RESULTS All vertical microgaps were clinically acceptable with values <90 μm. No statistically significant pairwise difference (P = 0.98) was observed between the relative effects of vertical microgap of unveneered (median 19 μm; 95% CI 13-35 μm) and veneered FDPs (20 μm; 13-31 μm), providing support for the null-hypothesis. Analysis within the groups showed significantly different values between the five implants of the FDPs before (P = 0.044) and after veneering (P = 0.020), while a monotonous trend of increasing values from implant 23 (closest position to screw-retained implant 25) to 15 (most distant implant) could not be observed (P = 0.169, P = 0.270). CONCLUSIONS Full-arch CAD/CAM titanium screw-retained frameworks have a high accuracy. Porcelain firing procedure had no impact on the precision of fit of the final FDPs. All implant microgap measurements of each FDP showed clinically acceptable vertical misfit values before and after veneering. Thus, the results do not only show accurate performance of the milling and firing but show also a reproducible scanning and designing process.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this online course is to ensure new nursing graduate students know how to use computer technologies required to complete academic and research activities. Powerful computers, high speed internet, digitalized resources and databases are widely available in educational institutes. New renovation and updates are being released at faster pace than ever. All these developments are necessary for a student to utilize computer programs and synthesize large amount of data in a limited time for any given academic research project. [See PDF for complete abstract]