949 resultados para Assembling (Electronic computers)


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: Electronic assistive technology (EAT) includes computers, environmental control systems and information technology systems and is widely considered to be an important part of present-day life. Method: Fifty-six Irish community occupational therapists completed a questionnaire on EAT. All surveyed were able to identify the benefits of EAT. Results: While respondents reported that they should be able to assess for and prescribe EATs, only a third (19) were able to do so, and half (28) had not been able to do so in the past. Community occupational therapists identified themselves as havinga role in a multidisciplinary team to assess for and prescribe EAT. Conclusion: Results suggest that it is important for occupational therapists to have up-to-date knowledge and training in assistive and computer technologies in order to respond to the occupational needs of clients.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The effectiveness of various kinds of computer programs is of concern to nurse-educators. Using a 3x3 experimental design, ninety second year diploma student nurses were randomly selected from a total population at three community colleges in Ontario. Data were collected via a 20-item valid and reliable Likert-type questionnaire developed by the nursing profession to measure perceptions of nurses about computers in the nursing role. The groups were pretested and posttested at the beginning and end of one semester. Subjects attending College A group received a computer literacy course which comprised word processing with technology awareness. College B students were exposed to computer-aided instruction primarily in nursing simulations intermittently throughout the semester. College C subjects maintained their regular curriculum with no computer involvement. The student's t-test (two-tailed) was employed to assess the attitude scores data and a one-way analysis of variance was performed on the attitude scores. Posttest analysis revealed that there was a significant difference (p<.05) between attitude scores on the use of computers in the nursing role between College A and C. No significant differences (p>.05) were seen between College B and A in posttesting. Suggestions for continued computer education of diploma student nurses are provided.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study examined nurses' attitudes toward computers before training and 2 months after training. A quantitative approach and a nonexperimental survey design were used in this study. Stronge and Brodt's (1985) instrument, Nurses' Attitudes Toward Computerization Questionnaire, was used to assess 27 nurses' attitudes prior to and 2 months after computer training. Demographic variables also were collected on the questionnaires. The results of this study showed that, overall, nurses had positive attitudes towards computers in both questionnaires. The results of the first questionnaire were consistent with other studies. There were no studies that involved a follow-up questionnaire using Stronge and Brodt's (1985) instrument. Attitude scores of Questionnaire 2 were higher than attitude scores of Questionnaire 1. More time for nursing tasks, less time for quality patient care, and threat to job security questions were found to be statistically significant. This study found no statistical significance between attitudes and demographic variables. Younger nurses a~d nurses with fewer years of computer experience were most likely to exhibit positive attitudes. Implications for practice and future research were discussed. Some limitations were identified and discussed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A linear trinuclear Ni-Schiff base complex [Ni-3(salpen)(2)(PhCH2COO)(2)(EtOH)] has been synthesized by combining Ni(ClO4)(2)center dot 6H(2)O, phenyl acetic acid (C6H5CH2COOH), and the Schiff base ligand, N,N'-bis(salicylidene)-1,3-pentanediamine (H(2)salpen). This complex is self-assembled through hydrogen bonding and C-H-g interaction in the solid state to generate a sheet-like architecture, while in organic solvent (CH2Cl2), it forms vesicles with a mean diameter of 290 nm and fused vesicles, depending upon the concentration of the solution. These vesicles act as an excellent carrier of dye molecules in CH2Cl2. The morphology of the complex has been determined by scanning electron microscopy and transmission electron microscopy experiments, and the encapsulation of dye has been examined by confocal microscopic image and electronic absorption spectra.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The present work will explain a method to achieve a remote controlled (via IR LED) alphanumeric Liquid Crystal Display. In modern times, the remote access of different devices has become quite popular, therefore, the aim of this project is to provide a useful tool that will integrate common and easy to access devices. The system includes a C language based user interface, an assembly language code for the AT89C51ED2 microcontroller instructions and some digital electronic circuits needed for the driving and control of both the LCD and the infrared communication, as well as the PC with a parallel port. The interaction of all the devices provides a whole system that can be helpful in different applications, or it can be separated into each one of its different stages to take the best advantage as possible.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to develop a laboratory method for time response evaluation on electronically controlled spray equipment using Programmable Logic Controllers (PLCs). For that purpose, a PLC controlled digital drive inverter was set up to drive an asynchronous electric motor linked to a centrifugal pump on a experimental sprayer equipped with electronic flow control. The PLC was operated via RS232 serial communication from a PC computer. A user program was written to control de motor by adjusting the following system variables, all related to the motor speed: time stopped; ramp up and ramp down times, time running at a given constant speed and ramp down time to stop the motor. This set up was used in conjunction with a data acquisition system to perform laboratory tests with an electronically controlled sprayer. Time response for pressure stabilization was measured while changing the pump speed by +/-20%. The results showed that for a 0.2 s ramp time increasing the motor speed, as an example, an AgLogix Flow Control system (Midwest Technologies Inc.) took 22 s in average to readjust the pressure. When decreasing the motor speed, this time response was down to 8 s. General results also showed that this kind of methodology could make easier the definition of standards for tests on electronically controlled application equipment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background Patients' health related quality of life (HRQoL) has rarely been systematically monitored in general practice. Electronic tools and practice training might facilitate the routine application of HRQoL questionnaires. Thorough piloting of innovative procedures is strongly recommended before the conduction of large-scale studies. Therefore, we aimed to assess i) the feasibility and acceptance of HRQoL assessment using tablet computers in general practice, ii) the perceived practical utility of HRQoL results and iii) to identify possible barriers hindering wider application of this approach. Methods Two HRQoL questionnaires (St. George's Respiratory Questionnaire SGRQ and EORTC QLQ-C30) were electronically presented on portable tablet computers. Wireless network (WLAN) integration into practice computer systems of 14 German general practices with varying infrastructure allowed automatic data exchange and the generation of a printout or a PDF file. General practitioners (GPs) and practice assistants were trained in a 1-hour course, after which they could invite patients with chronic diseases to fill in the electronic questionnaire during their waiting time. We surveyed patients, practice assistants and GPs regarding their acceptance of this tool in semi-structured telephone interviews. The number of assessments, HRQoL results and interview responses were analysed using quantitative and qualitative methods. Results Over the course of 1 year, 523 patients filled in the electronic questionnaires (1–5 times; 664 total assessments). On average, results showed specific HRQoL impairments, e.g. with respect to fatigue, pain and sleep disturbances. The number of electronic assessments varied substantially between practices. A total of 280 patients, 27 practice assistants and 17 GPs participated in the telephone interviews. Almost all GPs (16/17 = 94%; 95% CI = 73–99%), most practice assistants (19/27 = 70%; 95% CI = 50–86%) and the majority of patients (240/280 = 86%; 95% CI = 82–91%) indicated that they would welcome the use of electronic HRQoL questionnaires in the future. GPs mentioned availability of local health services (e.g. supportive, physiotherapy) (mean: 9.4 ± 1.0 SD; scale: 1 – 10), sufficient extra time (8.9 ± 1.5) and easy interpretation of HRQoL results (8.6 ± 1.6) as the most important prerequisites for their use. They believed HRQoL assessment facilitated both communication and follow up of patients' conditions. Practice assistants emphasised that this process demonstrated an extra commitment to patient centred care; patients viewed it as a tool, which contributed to the physicians' understanding of their personal condition and circumstances. Conclusion This pilot study indicates that electronic HRQoL assessment is technically feasible in general practices. It can provide clinically significant information, which can either be used in the consultation for routine care, or for research purposes. While GPs, practice assistants and patients were generally positive about the electronic procedure, several barriers (e.g. practices' lack of time and routine in HRQoL assessment) need to be overcome to enable broader application of electronic questionnaires in every day medical practice.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The "EMR Tutorial" is designed to be a bilingual online physician education environment about electronic medical records. After iterative assessment and redesign, the tutorial was tested in two groups: U.S. physicians and Mexican medical students. Split-plot ANOVA revealed significantly different pre-test scores in the two groups, significant cognitive gains for the two groups overall, and no significant difference in the gains made by the two groups. Users rated the module positively on a satisfaction questionnaire.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We report absolute experimental integral cross sections (ICSs) for electron impact excitation of bands of electronic-states in furfural, for incident electron energies in the range 20-250 eV. Wherever possible, those results are compared to corresponding excitation cross sections in the structurally similar species furan, as previously reported by da Costa et al. [Phys. Rev. A 85, 062706 (2012)] and Regeta and Allan [Phys. Rev. A 91, 012707 (2015)]. Generally, very good agreement is found. In addition, ICSs calculated with our independent atom model (IAM) with screening corrected additivity rule (SCAR) formalism, extended to account for interference (I) terms that arise due to the multi-centre nature of the scattering problem, are also reported. The sum of those ICSs gives the IAM-SCAR+I total cross section for electron-furfural scattering. Where possible, those calculated IAM-SCAR+I ICS results are compared against corresponding results from the present measurements with an acceptable level of accord being obtained. Similarly, but only for the band I and band II excited electronic states, we also present results from our Schwinger multichannel method with pseudopotentials calculations. Those results are found to be in good qualitative accord with the present experimental ICSs. Finally, with a view to assembling a complete cross section data base for furfural, some binary-encounter-Bethe-level total ionization cross sections for this collision system are presented. (C) 2016 AIP Publishing LLC.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

"This report supersedes BRL report no. 1010 ..."

Relevância:

30.00% 30.00%

Publicador:

Resumo:

"Retyped October, 1964"

Relevância:

30.00% 30.00%

Publicador:

Resumo:

"Revised March 23, 1965"

Relevância:

30.00% 30.00%

Publicador:

Resumo:

"Supported in part by the National Science Foundation under grant no. NSF GJ 28289."