917 resultados para Aortic aneurysm
Resumo:
In normal dogs and dogs with subaortic stenosis, it is known that the subcostal transducer site provides higher left ventricular ejection velocities than does the left apical site. We hypothesized that aortic flow velocities could also be obtained from the right parasternal long-axis view, optimized for the placement of the Doppler cursor as parallel as possible into the aortic root. In 15 healthy dogs and 13 healthy cats, high-pulsed repetition frequency Doppler flow velocity measurements in the proximal aorta were performed using two-dimensional echocardiographic guidance. The mean [ +/- standard error of the mean (SEM)] peak aortic flow velocities in healthy dogs were as follows: subcostal site 1.46 +/- 0.05 m/s; apical site 1.12 +/- 0.06 m/s; right parasternal long-axis site 1.09 +/- 0.05 m/s. In healthy cats, the following peak aortic flow velocities were observed: apical site 0.87 +/- 0.03m/s; right parasternal long-axis site 0.87 +/- 0.03 m/s. Aortic flow velocities obtained from the subcostal site were significantly higher in healthy dogs than those obtained from the left apical and right parasternal long-axis site (P< 0.001). There was no statistical difference between the peak aortic flow velocities obtained from right parasternal long-axis and left apical transducer position in all groups. We conclude therefore that right parasternal long-axis and left apical-derived aortic flow velocities are similar and may be used interchangeably in healthy dogs and cats.
Resumo:
OBJECTIVES: An optimized, longitudinal in vivo magnetic resonance vessel wall-imaging protocol was evaluated regarding its capability of detecting differences in the time-dependent atherosclerotic lesion progression in the aortic arch between ApoE(-/-) and double-deficient ApoE(-/-)/TNF(-/-) mice at comparatively early plaque development stages. MATERIALS AND METHODS: Seven ApoE(-/-) and seven ApoE(-/-)/TNF(-/-) female mice underwent MRI at 11.75 teslas at four stages up to 26 weeks of age. A double-gated spin-echo MRI sequence was used with careful perpendicular slice positioning to visualize the vessel wall of the ascending aortic arch. RESULTS: Wall-thickness progression measured with MRI was significant at 11 weeks of age in ApoE(-/-) mice, but only at 26 weeks in ApoE(-/-)/TNF(-/-) mice. A significant correlation was found between MRI wall-thickness and lesion area determined on histology. CONCLUSION: MRI was shown to be sensitive enough to reveal subtle genetically-induced differences in lesion progression at ages earlier than 25 weeks.
Resumo:
BACKGROUND: Different studies have analyzed the potential impact of the underlying pathologic process and the use of deep hypothermic circulatory arrest on outcome and quality of life after surgery on the thoracic aorta. The aim of this study is to analyze the impact of different surgical procedures on outcome and quality of life. METHODS: Between June 2001 and December 2003, 244 patients underwent surgery for various diseases of the ascending aorta with or without involvement of the aortic valve or root. They were divided according to the operative procedure: 76 patients (31.2%) underwent isolated replacement of the ascending aorta, 42 patients (17.2%) received separate aortic valve replacement and supracoronary replacement of the ascending aorta, 86 patients (35.2%) received a mechanical composite graft, and 40 patients (16.4%) received a biologic composite graft. All in-hospital data were assessed, and a follow-up was performed in all survivors after 26.6 +/- 8.8 months, focusing on outcome and quality of life (SF-36). RESULTS: Overall in-hospital mortality was 6.1%, and late mortality was 5.7%, with no significant difference between groups. Independent of the surgical technique and the extent of surgery, there was no difference in quality of life between the surgical collective and an age-matched and sex-matched standard population. CONCLUSIONS: Operations of the ascending aorta and aortic valve are very safe, with low in-hospital mortality and favorable midterm outcome regarding late mortality and morbidity. Quality of life after operations of the ascending aorta and aortic valve is equal to a standard population and is not affected by the surgical procedure. Liberal use of aortic root replacement is therefore justified to radically treat the diseased aortic segment.
Resumo:
Percutaneous valve replacement for severe aortic stenosis has shown to be an alternative treatment option for non-surgical candidates. We report on the first successful valve in valve procedure in an 80-year-old patient with a severe regurgitation of a degenerated aortic bioprosthesis using the Corevalve Revalving system.
Resumo:
OBJECTIVES: We sought to determine both the procedural performance and safety of percutaneous implantation of the second (21-French [F])- and third (18-F)-generation CoreValve aortic valve prosthesis (CoreValve Inc., Irvine, California). BACKGROUND: Percutaneous aortic valve replacement represents an emerging alternative therapy for high-risk and inoperable patients with severe symptomatic aortic valve stenosis. METHODS: Patients with: 1) symptomatic, severe aortic valve stenosis (area <1 cm2); 2) age > or =80 years with a logistic EuroSCORE > or =20% (21-F group) or age > or =75 years with a logistic EuroSCORE > or =15% (18-F group); or 3) age > or =65 years plus additional prespecified risk factors were included. Introduction of the 18-F device enabled the transition from a multidisciplinary approach involving general anesthesia, surgical cut-down, and cardiopulmonary bypass to a truly percutaneous approach under local anesthesia without hemodynamic support. RESULTS: A total of 86 patients (21-F, n = 50; 18-F, n = 36) with a mean valve area of 0.66 +/- 0.19 cm2 (21-F) and 0.54 +/- 0.15 cm2 (18-F), a mean age of 81.3 +/- 5.2 years (21-F) and 83.4 +/- 6.7 years (18-F), and a mean logistic EuroSCORE of 23.4 +/- 13.5% (21-F) and 19.1 +/- 11.1% (18-F) were recruited. Acute device success was 88%. Successful device implantation resulted in a marked reduction of aortic transvalvular gradients (mean pre 43.7 mm Hg vs. post 9.0 mm Hg, p < 0.001) with aortic regurgitation grade remaining unchanged. Acute procedural success rate was 74% (21-F: 78%; 18-F: 69%). Procedural mortality was 6%. Overall 30-day mortality rate was 12%; the combined rate of death, stroke, and myocardial infarction was 22%. CONCLUSIONS: Treatment of severe aortic valve stenosis in high-risk patients with percutaneous implantation of the CoreValve prosthesis is feasible and associated with a lower mortality rate than predicted by risk algorithms.
Resumo:
PURPOSE: This study was conducted to create an animal model for thoracic aortic transection that is suitable for thoracic endograft research. MATERIALS AND METHODS: Percutaneous aortic transection creation was attempted in 12 sheep. A custom collapsible circumferential cutting device was inserted into the proximal descending thoracic aorta via a femoral approach with an 11-F delivery catheter. The device was deployed 2 cm distal to the left subclavian artery origin and rotated 20 times to create aortic transection. Aortic diameters, mean aortic pressures, and heart rates were tested for degrees of difference between measurements before and after the creation of transection. On necropsy, the extent of aortic damage was classified as none, nontransmural, or transmural, and aortic transection was classified as none, partial, or circumferential. RESULTS: On angiography, creation of transmural thoracic aortic transection was successful in 91.7% (11/12) of animals. Aortic transection was circumferential in 54.4% (6/11) of animals and partial in 45.6% (5/11) of animals. Mean aortic diameter was 19.6 +/- 3.4 mm (range 12-24 mm) pre-transection and 25.8 +/- 4.5 mm (range 17.8-33 mm) post-transection (P = .0003). Pre-transection, mean aortic pressure was 79 +/- 13.8 mmHg, and 64.6 +/- 15.8 mmHg 15 min post-transection (P = .041). Pre-transection, mean heart rate was 94.5 +/- 17.2 beats per minute (bpm), and 105.8 +/- 17.2 bpm 15 min post-transection (P = .0057). CONCLUSIONS: Thoracic aortic transection was successfully created percutaneously in most animals. The animals remained in hemodynamically stable condition for as long as 240 minutes after the creation of aortic injury. This percutaneous animal model is straightforward and may be of potential value for future thoracic endograft research.
Resumo:
The effect of varying injection rates of a saline chaser on aortic enhancement in computed tomography (CT) angiography was determined. Single-level, dynamic CT images of a physiological flow phantom were acquired between 0 and 50 s after initiation of contrast medium injection. Four injection protocols were applied with identical contrast medium administration (150 ml injected at 5 ml/s). For baseline protocol A, no saline chaser was applied. For protocols B, C, and D, 50 ml of saline was injected at 2.5 ml/s, 5 ml/s, and 10 ml/s, respectively. Injecting the saline chaser at twice the rate as the contrast medium yielded significantly higher peak aortic enhancement values than injecting the saline at half or at the same rate as the contrast medium (P < 0.05). Average peak aortic enhancement (HU) measured 214, 214, 218, and 226 for protocols A, B, C, and D, respectively. The slower the saline-chaser injection rate, the longer the duration of 90% peak enhancement: 13.6, 12.2, and 11.7 s for protocols B, C, and D, respectively (P > 0.05). In CT angiography, saline chaser injected at twice the rate as the contrast medium leads to increased peak aortic enhancement and saline chaser injected at half the rate tends towards prolonging peak aortic enhancement plateau.
Resumo:
INTRODUCTION: Thrombotic events are a common and severe complication of endovascular aneurysm treatment with significant impact on patients' outcome. This study evaluates risk factors for thrombus formation and assesses the efficacy and safety of abciximab for clot dissolution. MATERIALS AND METHODS: All patients treated with abciximab during (41 patients) or shortly after (22 patients) intracranial aneurysm coil embolisation were retrieved from the institutional database (2000 to 2007, 1,250 patients). Sixty-three patients (mean age, 55.3 years, +/-12.8) had received either intra-arterial or intravenous abciximab. Risk factors for clot formation were assessed and the angiographic and clinical outcome evaluated. RESULTS: No aneurysm rupture occurred during or after abciximab application. The intra-procedural rate of total recanalisation was 68.3%. Thromboembolic complications were frequently found in aneurysms of the Acom complex and of the basilar artery, whilst internal carotid artery aneurysms were underrepresented. Two patients died of treatment-related intracranial haemorrhages into preexisting cerebral infarcts. Two patients developed a symptomatic groin haematoma. CONCLUSIONS: Abciximab is efficacious and safe for thrombolysis during and after endovascular intracranial aneurysm treatment in the absence of preexisting ischaemic stroke.
Resumo:
Coronary aneurysm formation after drug-eluting stent (DES) implantation is a rare complication with late stent thrombosis as a potentially fatal sequela. One possible mechanism involved in aneurysm formation is thought to be late-acquired stent malapposition due to a local inflammatory response to the polymer and/or the drug. Coronary aneurysm formation has been documented with sirolimus- and paclitaxel-eluting stents. We report a case of coronary aneurysm formation in a patient with an everolimus-eluting stent (EES; Xience(R) Abbott Vascular, Redwood City, California) relatively early (3 months) after stent implantation. This case illustrates that even with second-generation DES like the EES, which is thought to be highly biocompatible, there can be adverse reactions to the polymer and/or to the drug.
Resumo:
AIMS: To describe the procedural performance and 30-day outcomes following implantation using the 18 Fr CoreValve Revalving System (CRS) as part of the multicentre, expanded evaluation registry, 1-year after obtaining CE mark approval. METHODS AND RESULTS: Patients with symptomatic severe aortic stenosis and logistic Euroscore > or =15%, or age > or =75 years, or age > or =65 years associated with pre-defined risk factors, and for whom a physician proctor and a clinical specialist were in attendance during the implantation and who collected the clinical data, were included. From April 2007, to April 2008, 646 patients with a mean age of 81 +/- 6.6 years, mean aortic valve area 0.6 +/- 0.2 cm2, and logistic EuroSCORE of 23.1 +/- 13.8% were recruited. After valve implantation, the mean transaortic valve gradient decreased from 49.4 +/- 13.9 to 3 +/- 2 mmHg. All patients had paravalvular aortic regurgitation < or = grade 2. The rate of procedural success was 97%. The procedural mortality rate was 1.5%. At 30 days, the all-cause mortality rate (i.e, including procedural) was 8% and the combined rate of death, stroke and myocardial infarction was 9.3%. CONCLUSIONS: The results of this study demonstrate the high rate of procedural success and a low 30-day mortality in a large cohort of high-risk patients undergoing transcatheter aortic valve implantation (TAVI) with the CRS.