Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work a simple and versatile procedure is described for treating water samples using small polypropylene (PP) vials (4 mL) for determining heavy metals by square wave voltammetry (SWV). This procedure involves treatment with nitric acid (0.2 mol L-1) and boiling in a water-bath (~ 100 ºC). This process is completed after one hour and allows the pretreatment of several samples simultaneously. The accuracy was estimated using addition/recovery studies and certified water sample analysis, yielding an agreement near to 100%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Leaves of Lippia alba were submitted to six different drying treatments, using air at ambient temperature and heated up to 80 °C. The essential oil was extracted by steam distillation and analyzed by GC-MS. For the dried leaves, the oil content was reduced by 12 to 17% when compared with the fresh plant (0.66%). The major oil component was citral, representing 76% for the fresh plant, and varying from 82 to 84% for the dried material. These results showed that L. alba can be submitted to a drying process of up to 80 ºC without degradation and/or loss of the major, [LC1] active component.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ilex paraguariensis is a native plant in Southern Brazil, whose leaves are utilized in beverages such as chimarrão and tererê. This study investigated variations of total methylxanthines in leaves from two Ilex populations collected at one-month intervals over the course of one year. The levels varied from 1.92 to 10.37 mg/g (Ijuí) and 1.77 to 9.17 mg/g (Santa Maria). Statistical analysis indicated a significative variation in the contents of all samples analysed, confirming seasonal fluctuations. These results show that the period of harvest might decisively influence the organoleptic characteristics of raw material used in industry and therefore in commercial products.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new titrimetric method for the determination of phosphite in fertilizer samples, based on reaction of H3PO3 with standard iodine solution in neutral media, is proposed. Diluted samples containing ca. 0.4% m/v P2O5 are heated and titrated with 0.05 mol L-1 iodine standard until the solution becomes faint yellow. Back titration is also feasible: a slight excess of titrant is added followed by starch indicator and titration is completed taking as the end point the change in color from blue to colorless. The influence of chemical composition and pH of buffers, temperature and foreign species on waiting time and end-point detection were investigated. For the Na2HPO4/NaH2PO4 buffer (pH 6.8) at 70 °C, the titration time was 10 min, corresponding to about 127 mg iodine, 200 mg KI and 174 mg Na2HPO4 and 176 mg NaH2PO4 consumed per determination. Accuracy was checked for phosphite determination in seven fertilizer samples. Results obtained by the proposed procedure were in agreement with those obtained by spectrophotometry at 95% confidence level. The R.S.D. (n=10) for direct and back titration was 0.4% and 1.3% respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An air quality evaluation of indoor environments with focus on lower carbonyls was carried out in 50 public places using TO-11A methodology. Formaldehyde levels (ranging from 12.5 to 1034 mg m-3) were above the threshold limit in 49 of 50 analyzed samples while acetaldehyde (ranging from 5.2 to 840 mg m-3) and acetone (ranging from 5.5 to 4839 mg m-3) were respectively bellow the limits of OSHA and NIOSH in all samples. However all samples were bellow the threshold limits suggested by the Brazilian legislation - NR-15. A correlation study between the carbonyls and temperature and humidity was also done.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Brazilian legislation requires analysis of certain parameters to classify a wine and allow its commercialization. Some physico-chemical and some color parameters were determined in this work in samples of different red wines sold in the metropolitan area of Recife. Multivariate analysis comprising principal component analysis and hierarchical cluster analysis was employed to distinguish the analyzed wines. The results for pH, chloride concentration, color parameters and ammonium content were the most important variables for sample classification. It was also possible to classify the wines as soft or dry wines and amongst the soft wines we could determine two out of four winegrowing producers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper reports the development of a methodology for simultaneously determining As, Cd and Pb, employing GF AAS with polarized Zeeman-effect background correction. In order to make the procedure applicable, the influence of pyrolysis and atomization temperatures and the amount of chemical modifiers were studied. Factorial and central composite designs were used to optimize these variables. Precision and accuracy of the method were investigated using Natural Water Reference material, Nist SRM 1640. Results are in agreement with certified values at the 95% confidence limit when the Student t-test is used. This methodology was used for quality control of purified water for hemodialysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study presents Pd determinations in bovine tissue samples containing palladium prepared in the laboratory, and CCQM-P63 automotive catalyst materials of the Proficiency Test, using instrumental thermal and epithermal neutron activation analysis and energy dispersive X-ray fluorescence techniques. Solvent extraction and solid phase extraction procedures were also applied to separate Pd from interfering elements before the irradiation in the nuclear reactor. The results obtained by different techniques were compared against each other to examine sensitivity, precision and accuracy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work describes the optimization of pretreatment steps for the destruction of organic matter in samples of waters and biological fluids, by using an UV irradiation system with a high power UV radiation source (400 W). The efficiency of the system constructed for the photo-decomposition of samples of model waters, natural waters and biological fluids was investigated by performing recovery experiments of the metallic species Zn(II), Cd(II), Pb(II), Cu(II), Al(III) and Fe(III). The use of UV irradiation allowed the liberation of metals bound to the organic matrix and the determination of the total content of elements in the samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In Surface water concentrations of N2O were measured at 37 stations in Guanabara Bay and fluxes estimated across the air-sea interface. Concentrations averaged 8.2 ± 2.2 nmol L-1 and 90% of the stations showed supersaturation averaging 33%. N2O fluxes were estimated using a two-film model which is given by the product of the concentration difference across the film and the gas transfer coefficient (k w). Two parametrizations of k w were used which provided average fluxes of 0.3 and 3.0 µg N m-2 h-1. Flux measurements using floating chambers (not reported here) seem to agree with the upper limit of these estimates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Foliar analysis of biochemical parameters were carried out in order to investigate the influence of air pollutants on two tropical tree species (Licania tomentosa (Benth.) and Bauhinia forfícata (Link.)). Special attention was given to tropospheric ozone due to the fact that concentration levels in the region were found to be up to 140 µg m-3 for a 4 h average time, which is well above the value that can cause injuries to orchides and tobacco (59 µg m-3). Other pollutants such as nitrogen and sulphur oxides were measured and their ambient concentrations were also associated to biochemical alterations in the investigated species.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Methyl ethyl ketone (MEK) is a solvent commonly used in chemical, paint and shoe industry. The aim of this study was to develop and validate a method for urinary quantification of MEK, employing headspace solid phase micro extraction sampling (SPME) coupled to gas chromatography with flame ionization detection (GC-FID). The calibration curve (y=4.6851x-0.0011) presented good linearity with r²=0.9993. Accuracy (94-109%), intra-assay precision (4.07-5.91%) and inter-assay precision (3.03-5.62%) were acceptable. The quantification limit was 0.19 mg/L. This low cost method can be used routinely in the biological monitoring of occupational exposure to MEK, according to the requirements of the Brazilian legislation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We describe the design and tests of a set-up mounted in a conventional double beam spectrophotometer, which allows the determination of optical density of samples confined in a long liquid core waveguide (LCW) capillary. Very long optical path length can be achieved with capillary cell, allowing measurements of samples with very low optical densities. The device uses a custom optical concentrator optically coupled to LCW (TEFLON® AF). Optical density measurements, carried out using a LCW of ~ 45 cm, were in accordance with the Beer-Lambert Law. Thus, it was possible to analyze quantitatively samples at concentrations 45 fold lower than that regularly used in spectrophotometric measurements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work deals with paint decomposition methods for major, minor and trace elements determination. Three methods were investigated: (1) decomposition in closed quartz vessel and heating in microwave oven; (2) decomposition in open vessel using HNO3 and ashing, following the ASTM D 3335-85a method; and (3) decomposition in open vessel using HNO3 + HF and ashing. Paints of different types and colours were analyzed, in which several elements were determined using inductively coupled plasma mass spectrometry (ICP-MS) and inductively coupled plasma optical emission spectrometry (ICP OES). It was observed that method (1) is appropriate for trace, minor and major elements determination, while method (3) is appropriate for Ti.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Batch sorption experiments were carried out to remove methylene blue from its aqueous solutions using zeolites synthesized from fly ashes as an adsorbent. The adsorbents were characterized by XFR, XRD and SEM. Nearly 90 min of contact time are found to be sufficient for the adsorption of dye to reach equilibrium. Equilibrium data have been analyzed using Langmuir and Freundlich isotherms and the results were found to be well represented by the Freundlich isotherm equation. Adsorption data were fitted to both Lagergren first-order and pseudo-second-order kinetic models and the data were found to follow pseudo-second-order kinetics.