928 resultados para Americium 241, standard deviation
Resumo:
BACKGROUND: The risk of osteoporosis and fracture influences the selection of adjuvant endocrine therapy. We analyzed bone mineral density (BMD) in Swiss patients of the Breast International Group (BIG) 1-98 trial [treatment arms: A, tamoxifen (T) for 5 years; B, letrozole (L) for 5 years; C, 2 years of T followed by 3 years of L; D, 2 years of L followed by 3 years of T]. PATIENTS AND METHODS: Dual-energy X-ray absorptiometry (DXA) results were retrospectively collected. Patients without DXA served as control group. Repeated measures models using covariance structures allowing for different times between DXA were used to estimate changes in BMD. Prospectively defined covariates were considered as fixed effects in the multivariable models. RESULTS: Two hundred and sixty-one of 546 patients had one or more DXA with 577 lumbar and 550 hip measurements. Weight, height, prior hormone replacement therapy, and hysterectomy were positively correlated with BMD; the correlation was negative for letrozole arms (B/C/D versus A), known osteoporosis, time on trial, age, chemotherapy, and smoking. Treatment did not influence the occurrence of osteoporosis (T score < -2.5 standard deviation). CONCLUSIONS: All aromatase inhibitor regimens reduced BMD. The sequential schedules were as detrimental for bone density as L monotherapy.
Carbonate Rock Pore Size Distribution Determination through Iowa Pore Index Testing, MLR-15-01, 2015
Resumo:
The Iowa Pore Index (IPI) measures the pore system of carbonate (limestone and dolomite) rocks using pressurized water to infiltrate the pore system. This technique provides quantitative results for the primary and capillary (secondary) pores in carbonate rocks. These results are used in conjunction with chemical and mineralogical test results to calculate a quality number, which is used as a predictor of aggregate performance in Portland cement concrete (PCC) leading to the durability classification of the aggregate. This study had two main objectives: to determine the effect different aggregate size has on IPI test results and to establish the precision of IPI test and test apparatus. It was found that smaller aggregate size fractions could be correlated to the standard 1/2”-3/4” size sample. Generally, a particle size decrease was accompanied by a slight decrease in IPI values. The IPI testing also showed fairly good agreement of the secondary pore index number between the 1/2”-3/4”and the 3/8”-1/2” fraction. The #4-3/8” showed a greater difference of the secondary number from the 1/2”-3/4” fraction. The precision of the IPI test was established as a standard deviation (Sr) of 2.85 (Primary) and 0.87 (Secondary) with a repeatability limit (%r) of 8.5% and 14.9% for the primary and secondary values, respectively.
Resumo:
BACKGROUND AND STUDY AIMS: Removal of colorectal polyps is routinely performed during withdrawal of the endoscope. However, polyps detected during insertion of the colonoscope may be missed at withdrawal. We aimed to evaluate whether polypectomy during both insertion and withdrawal increases polyp detection and removal rates compared with polypectomy at withdrawal only, and to assess the duration of both approaches. PATIENTS AND METHODS: Patients were included into the study when the first polyp was detected, and randomized into two groups; in group A, polyps ≤ 10 mm in diameter were removed during insertion and withdrawal of the colonoscope, while in group B, these polyps were removed at withdrawal only. Main outcome measures were duration of colonoscopy, number of polyps detected during insertion but not recovered during withdrawal, technical ease, patient discomfort, and complications. RESULTS: 150 patients were randomized to group A and 151 to group B. Mean (± standard deviation [SD]) duration of colonoscopy did not differ between the groups (30.8 ± 15.6 min [A] vs. 28.5 ± 13.8 min [B], P = 0.176). In group A 387 polyps (mean 2.58 per colonoscopy) were detected and removed compared with 389 polyps detected (mean 2.58 per colonoscopy) in group B of which 376 were removed (13 polyps were missed, mean size [SD] 3.2 [1.3] mm; 7.3 % of patients). Patient tolerance was similar in the two groups. CONCLUSIONS: Removal of polyps ≤ 10 mm during withdrawal only is associated with a considerable polyp miss rate. We therefore recommend that these polyps are removed during both insertion and withdrawal.
Resumo:
The Jebel Ressas Pb-Zn deposits in North-Eastern Tunisia occur mainly as open-space fillings (lodes, tectonic breccia cements) in bioclastic limestones of the Upper Jurassic Ressas Formation and along the contact of this formation with Triassic rocks. The galena-sphalerite association and their alteration products (cerussite, hemimorphite, hydrozincite) are set within a calcite gangue. The Triassic rocks exhibit enrichments in trace metals, namely Pb, Co and Cd enrichment in clays and Pb, Zn, Cd, Co and Cr enrichment in carbonates, suggesting that the Triassic rocks have interacted with the ore-bearing fluids associated with the Jebel Ressas Pb-Zn deposits. The delta(18)O content of calcite associated with the Pb-Zn mineralization suggests that it is likely to have precipitated from a fluid that was in equilibrium with the Triassic dolostones. The delta(34)S values in galenas from the Pb-Zn deposits range from -1.5 to +11.4%, with an average of 5.9% and standard deviation of 3.9%. These data imply mixing of thermochemically-reduced heavy sulfur carried in geothermal- and fault-stress-driven deep-seated source fluid with bacterially-reduced light sulfur carried in topography-driven meteoric fluid. Lead isotope ratios in galenas from the Pb-Zn deposits are homogenous and indicate a single upper crustal source of base-metals for these deposits. Synthesis of the geochemical data with geological data suggests that the base-metal mineralization at Jebel Ressas was formed during the Serravallian-Tortonian (or Middle-Late Miocene) Alpine compressional tectonics.
Resumo:
The aim of this study was to develop an ambulatory system for the three-dimensional (3D) knee kinematics evaluation, which can be used outside a laboratory during long-term monitoring. In order to show the efficacy of this ambulatory system, knee function was analysed using this system, after an anterior cruciate ligament (ACL) lesion, and after reconstructive surgery. The proposed system was composed of two 3D gyroscopes, fixed on the shank and on the thigh, and a portable data logger for signal recording. The measured parameters were the 3D mean range of motion (ROM) and the healthy knee was used as control. The precision of this system was first assessed using an ultrasound reference system. The repeatability was also estimated. A clinical study was then performed on five unilateral ACL-deficient men (range: 19-36 years) prior to, and a year after the surgery. The patients were evaluated with the IKDC score and the kinematics measurements were carried out on a 30 m walking trial. The precision in comparison with the reference system was 4.4 degrees , 2.7 degrees and 4.2 degrees for flexion-extension, internal-external rotation, and abduction-adduction, respectively. The repeatability of the results for the three directions was 0.8 degrees , 0.7 degrees and 1.8 degrees . The averaged ROM of the five patients' healthy knee were 70.1 degrees (standard deviation (SD) 5.8 degrees), 24.0 degrees (SD 3.0 degrees) and 12.0 degrees (SD 6.3 degrees for flexion-extension, internal-external rotation and abduction-adduction before surgery, and 76.5 degrees (SD 4.1 degrees), 21.7 degrees (SD 4.9 degrees) and 10.2 degrees (SD 4.6 degrees) 1 year following the reconstruction. The results for the pathologic knee were 64.5 degrees (SD 6.9 degrees), 20.6 degrees (SD 4.0 degrees) and 19.7 degrees (8.2 degrees) during the first evaluation, and 72.3 degrees (SD 2.4 degrees), 25.8 degrees (SD 6.4 degrees) and 12.4 degrees (SD 2.3 degrees) during the second one. The performance of the system enabled us to detect knee function modifications in the sagittal and transverse plane. Prior to the reconstruction, the ROM of the injured knee was lower in flexion-extension and internal-external rotation in comparison with the controlateral knee. One year after the surgery, four patients were classified normal (A) and one almost normal (B), according to the IKDC score, and changes in the kinematics of the five patients remained: lower flexion-extension ROM and higher internal-external rotation ROM in comparison with the controlateral knee. The 3D kinematics was changed after an ACL lesion and remained altered one year after the surgery
Resumo:
BACKGROUND: Diverse psychological factors are involved in the pathophysiology of stress. In order to devise effective intervention strategies, it is important to elucidate which factors play the most important role in the association between psychological stress and exacerbation of Crohn's disease (CD). We hypothesized that the association between perceived stress and exacerbation of CD would remain after removal of mood and anxiety components, which are largely involved in stress perception. METHODS: In all, 468 adults with CD were recruited and followed in different hospitals and private practices of Switzerland for 18 months. At inclusion, patients completed the Perceived Stress Questionnaire and anxiety and depression were assessed using the Hospital Anxiety and Depression Scale. During the follow-up, gastroenterologists assessed whether patients presented with a CD exacerbation. By means of binary logistic regression analysis, we estimated the factor by which one standard deviation of perceived stress would increase the odds of exacerbation of CD with and without controlling for anxiety and depression. RESULTS: The odds of exacerbation of CD increased by 1.85 times (95% confidence interval 1.43-2.40, P < 0.001) for 1 standard deviation of perceived stress. After removing the anxiety and depression components, the residuals of perceived stress were no longer associated with exacerbation of CD. CONCLUSIONS: The association between perceived stress and exacerbation of CD was fully attributable to the mood components, specifically anxiety and depression. Future interventional studies should evaluate the treatment of anxiety and depression as a strategy for potential prevention of CD exacerbations.
Resumo:
Although physical activity is recommended in patients on maintenance hemodialysis (MHD), randomized controlled trials testing the effects of exercise in this population have given conflicting results. In general, aerobic exercises mostly failed to produce improvements in physical function, whereas resistance exercises, although less studied, appeared to be more promising. The use of sophisticated materials such as leg press and free weights may preclude widespread application of resistance training in patients on MHD. Simple and cheap elastic bands may thus be an attractive alternative. We tested the feasibility of a supervised intradialytic resistance band exercise training program, and its effects on physical function, in patients on MHD. A total of 11 unselected adult patients on MHD from our center, aged 70 ± 10.7 (mean ± standard deviation) years, including 8 men and 3 women, accepted to follow the program under the supervision of qualified physiotherapists. Thirty-six exercise sessions of moderate intensity (twice a week, mean duration 40 minutes each, during 4.5 to 6 months), mainly involving leg muscles against an elastic resistance, were performed. The exercise program was well tolerated and all patients completed it. Statistically significant improvements were observed in the following tests: Tinetti test, 23.9 ± 3.9 points before versus 25.7 ± 3.5 points after the program (P = .022); the Timed Up and Go test, 12.1 ± 6.6 versus 10 ± 5.8 seconds (P = .0156). Improvements in the 6-minute walk distance and in the one-leg balance tests just failed to reach statistical significance. In this single-center pilot study, an intradialytic resistance band exercise program was feasible, well tolerated, and showed encouraging results on physical function.
Resumo:
Recent genome-wide association (GWA) studies described 95 loci controlling serum lipid levels. These common variants explain ∼25% of the heritability of the phenotypes. To date, no unbiased screen for gene-environment interactions for circulating lipids has been reported. We screened for variants that modify the relationship between known epidemiological risk factors and circulating lipid levels in a meta-analysis of genome-wide association (GWA) data from 18 population-based cohorts with European ancestry (maximum N = 32,225). We collected 8 further cohorts (N = 17,102) for replication, and rs6448771 on 4p15 demonstrated genome-wide significant interaction with waist-to-hip-ratio (WHR) on total cholesterol (TC) with a combined P-value of 4.79×10(-9). There were two potential candidate genes in the region, PCDH7 and CCKAR, with differential expression levels for rs6448771 genotypes in adipose tissue. The effect of WHR on TC was strongest for individuals carrying two copies of G allele, for whom a one standard deviation (sd) difference in WHR corresponds to 0.19 sd difference in TC concentration, while for A allele homozygous the difference was 0.12 sd. Our findings may open up possibilities for targeted intervention strategies for people characterized by specific genomic profiles. However, more refined measures of both body-fat distribution and metabolic measures are needed to understand how their joint dynamics are modified by the newly found locus.
Resumo:
The goal of this study was to investigate the impact of computing parameters and the location of volumes of interest (VOI) on the calculation of 3D noise power spectrum (NPS) in order to determine an optimal set of computing parameters and propose a robust method for evaluating the noise properties of imaging systems. Noise stationarity in noise volumes acquired with a water phantom on a 128-MDCT and a 320-MDCT scanner were analyzed in the spatial domain in order to define locally stationary VOIs. The influence of the computing parameters in the 3D NPS measurement: the sampling distances bx,y,z and the VOI lengths Lx,y,z, the number of VOIs NVOI and the structured noise were investigated to minimize measurement errors. The effect of the VOI locations on the NPS was also investigated. Results showed that the noise (standard deviation) varies more in the r-direction (phantom radius) than z-direction plane. A 25 × 25 × 40 mm(3) VOI associated with DFOV = 200 mm (Lx,y,z = 64, bx,y = 0.391 mm with 512 × 512 matrix) and a first-order detrending method to reduce structured noise led to an accurate NPS estimation. NPS estimated from off centered small VOIs had a directional dependency contrary to NPS obtained from large VOIs located in the center of the volume or from small VOIs located on a concentric circle. This showed that the VOI size and location play a major role in the determination of NPS when images are not stationary. This study emphasizes the need for consistent measurement methods to assess and compare image quality in CT.
Allergic rhinitis in patients with asthma: the Swiss LARA (Link Allergic Rhinitis in Asthma) survey.
Resumo:
OBJECTIVE: To determine the characteristics of asthma (A) and allergic rhinitis (AR) among asthma patients in primary care practice. RESEARCH DESIGN AND METHODS: Primary care physicians, pulmonologists, and allergologists were asked to recruit consecutive asthma patients with or without allergic rhinitis from their daily practice. Cross-sectional data on symptoms, severity, treatment and impact on quality of life of A and AR were recorded and examined using descriptive statistics. Patients with and without AR were then compared. RESULTS: 1244 asthma patients were included by 211 physicians. Asthma was controlled in 19%, partially controlled in 27% and not controlled in 54%. Asthma treatment was generally based on inhaled corticosteroids (ICS) with or without long acting beta 2 agonists (78%). A leukotriene receptor antagonist (LTRA) was used by 46% of the patients. Overall, 950 (76%) asthma patients had AR (A + AR) and 294 (24%) did not (A - AR). Compared to patients with A - AR, A + AR patients were generally younger (mean age +/- standard deviation: 42 +/- 16 vs. 50 +/- 19 years, p < 0.001) and fewer used ICS (75% vs. 88%, p < 0.001). LTRA usage was similar in both groups (46% vs. 48%). Asthma was uncontrolled in 53% of A + AR and 57% of A - AR patients. Allergic rhinitis was treated with a mean of 1.9 specific AR medications: antihistamines (77%), nasal steroids (66%) and/or vasoconstrictors (38%), and/or LTRA (42%). Rhinorrhoea, nasal obstruction, or nasal itching were the most frequently reported AR symptoms and the greatest reported degree of impairment was in daily activities/sports (55%). CONCLUSIONS: Allergic rhinitis was more common among younger asthma patients, increased the burden of symptoms and the need for additional medication but was associated with improved asthma control. However, most asthma patients remained suboptimally controlled regardl-ess of concomitant AR.
Resumo:
Professional cleaning is a basic service occupation with a wide variety of tasks carried out in all kind of different sectors and workplaces by a large workforce. One important risk for cleaning workers is the exposure to chemical substances that are present in cleaning products.Monoethanolamine was found to be often present in cleaning products such as general purpose cleaners, bathroom cleaners, floor cleaners and kitchen cleaners. Monoethanolamine can injure the skin, and exposure to monoethanolamine was associated to asthma even when the air concentrations were low. It is a strong irritant and known to be involved in sensitizing mechanisms. It is very likely that the use of cleaning products containing monoethanolamine gives rise to respiratory and dermal exposures. Therefore there is a need to further investigate the exposures to monoethanolamine for both, respiratory and dermal exposure.The determination of monoethanolamine has traditionally been difficult and analytical methods available are little adapted for occupational exposure assessments. For monoethanolamine air concentrations, a sampling and analytical method was already available and could be used. However, a method to analyses samples for skin exposure assessments as well as samples of skin permeation experiments was missing. Therefore one main objective of this master thesis was to search an already developed and described analytical method for the measurement of monoethanolamine in water solutions, and to set it up in the laboratory. Monoethanolamine was analyzed after a derivatisation reaction with o-pthtaldialdehyde. The derivated fluorescing monoethanolamine was then separated with high performance liquid chromatography and detection took place with a fluorescent detector. The method was found to be suitable for qualitative and quantitative analysis of monoethanolamine. An exposure assessment was conducted in the cleaning sector to measure the respiratory and dermal exposures to monoethanolamine during floor cleaning. Stationary air samples (n=36) were collected in 8 companies and samples for dermal exposures (n=12) were collected in two companies. Air concentrations (Mean = 0.18 mg/m3, Standard Deviation = 0.23 mg/m3, geometric Mean = 0.09 mg/m3, Geometric Standard Deviation = 3.50) detected were mostly below 1/10 of the Swiss 8h time weighted average occupational exposure limit. Factors that influenced the measured monoethanolamine air concentrations were room size, ventilation system and the concentration of monoethanolamine in the cleaning product and amount of monoethanolamine used. Measured skin exposures ranged from 0.6 to 128.4 mg/sample. Some cleaning workers that participated in the skin exposure assessment did not use gloves and had direct contact with the solutions containing the cleaning product and monoethanolamine. During the entire sampling campaign, cleaning workers mostly did not use gloves. Cleaning workers are at risk to be regularly exposed to low air concentrations of monoethanolamine. This exposure may be problematic if a worker suffers from allergic reactions (e.g. Asthma). In that case a substitution of the cleaning product may be a good prevention measure as several different cleaning products are available for similar cleaning tasks. Currently there are no occupational exposure limits to compare the skin exposures that were found. To prevent skin exposures, adaptations of the cleaning techniques and the use of gloves should be considered. The simultaneous skin and airborne exposures might accelerate adverse health effects. Overall the risks caused by exposures to monoethanolamine are considered as low to moderate when the cleaning products are used correctly. Whenever possible, skin exposures should be avoided. Further research should consider especially the dermal exposure routes, as very high exposures might occur by skin contact with cleaning products. Dermatitis but also sensitization might be caused by skin exposures. In addition, new biomedical insights are needed to better understand the risks of the dermal exposure. Therefore skin permeability experiments should be considered.
Resumo:
This paper aims to examine changes in common longevity and variability of the adult life span, and attempts to answer whether or not the compression of mortality continues in Switzerland in the years 1876-2005. The results show that the negative relationships between the large increase in the adult modal age at death, observed at least from the 1920s, and the decrease in the standard deviation of the ages at deaths occurring above it, illustrate a significant compression of adult mortality. Typical adult longevity increased by about 10% during the last fifty years in Switzerland, and adult heterogeneity in the age at death decreased in the same proportion. This analysis has not found any evidence suggesting that we are approaching longevity limits in term of modal or even maximum life spans. It ascertains a slowdown in the reduction of adult heterogeneity in longevity, already observed in Japan and other low mortality countries.
Resumo:
The objective of this work was to evaluate a generalized response function to the atmospheric CO2 concentration [f(CO2)] by the radiation use efficiency (RUE) in rice. Experimental data on RUE at different CO2 concentrations were collected from rice trials performed in several locations around the world. RUE data were then normalized, so that all RUE at current CO2 concentration were equal to 1. The response function was obtained by fitting normalized RUE versus CO2 concentration to a Morgan-Mercer-Flodin (MMF) function, and by using Marquardt's method to estimate the model coefficients. Goodness of fit was measured by the standard deviation of the estimated coefficients, the coefficient of determination (R²), and the root mean square error (RMSE). The f(CO2) describes a nonlinear sigmoidal response of RUE in rice, in function of the atmospheric CO2 concentration, which has an ecophysiological background, and, therefore, renders a robust function that can be easily coupled to rice simulation models, besides covering the range of CO2 emissions for the next generation of climate scenarios for the 21st century.
Resumo:
Peer-reviewed
Resumo:
Objectives: Quantitative ultrasound (QUS) is an attractive method for assessing fracture risk because it is portable, inexpensive, without ionizing radiation, and available in areas of the world where DXA is not readily accessible or affordable. However, the diversity of QUS scanners and variability of fracture outcomes measured in different studies is an important obstacle to widespread utilisation of QUS for fracture risk assessment. We aimed in this review to assess the predictive power of heel QUS for fractures considering different characteristics of the association (QUS parameters and fracture outcomes measured, QUS devices, study populations, and independence from DXA-measured bone density).Materials/Methods : We conducted an inverse-variance randomeffects meta-analysis of prospective studies with heel QUS measures at baseline and fracture outcomes in their follow-up. Relative risks (RR) per standard deviation (SD) of different QUS parameters (broadband ultrasound attenuation [BUA], speed of sound &SOS;, stiffness index &SI;, and quantitative ultrasound index [QUI]) for various fracture outcomes (hip, vertebral, any clinical, any osteoporotic, and major osteoporotic fractures) were reported based on study questions.Results : 21 studies including 55,164 women and 13,742 men were included with a total follow-up of 279,124 person-years. All four QUS parameters were associated with risk of different fractures. For instance, RR of hip fracture for 1 SD decrease of BUA was 1.69 (95% CI 1.43-2.00), SOS was 1.96 (95% CI 1.64-2.34), SI was 2.26 (95%CI 1.71-2.99), and QUI was 1.99 (95% CI 1.49-2.67). Validated devices from different manufacturers predicted fracture risks with a similar performance (meta-regression p-values>0.05 for difference of devices). There was no sign of publication bias among the studies. QUS measures predicted fracture with a similar performance in men and women. Meta-analysis of studies with QUS measures adjusted for hip DXA showed a significant and independent association with fracture risk (RR/SD for BUA =1.34 [95%CI 1.22-1.49]).Conclusions : This study confirms that QUS of the heel using validated devices predicts risk of different fracture outcomes in elderly men and women. Further research and international collaborations are needed for standardisation of QUS parameters across various manufacturers and inclusion of QUS in fracture risk assessment tools. Disclosure of Interest : None declared.