951 resultados para Air-flow Rate


Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper describes preliminary work on the generation of synthesis gas from water electrolysis using graphite electrodes without the separation of the generated gases. This is an innovative process, that has no similar work been done earlier. Preliminary tests allowed to establish correlations between the applied current to the electrolyser and flow rate and composition of the generated syngas, as well as a characterisation of generated carbon nanoparticles. The obtained syngas can further be used to produce synthetic liquid fuels, for example, methane, methanol or DME (dimethyl ether) in a catalytic reactor, in further stages of a present ongoing project, using the ELECTROFUEL® concept. The main competitive advantage of this project lies in the built-in of an innovative technology product, from RE (renewable energy) power in remote locations, for example, islands, villages in mountains as an alternative for energy storage for mobility constraints.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Master Thesis to obtain the Master degree in Chemical Engineering - Branch Chemical Processes

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Atualmente o gás natural é a principal fonte de energia utilizada pela maioria dos europeus nos setores doméstico, terciário e industrial. É considerado a alternativa energética do futuro e a mais ecologicamente correta de que podemos dispor, numa escala compatível com as elevadas necessidades energéticas da Humanidade a nível global. Aliado a estes factos, surgem cada vez mais regras de boa prática, normas e legislação, nomeadamente especificações técnicas de forma a regular o setor e dotar as entidades intervenientes na conceção e controlo de uma instalação de rede de gás, de um conhecimento mais detalhado e atualizado sobre esta matéria. Esta dissertação pretende assim contribuir para a melhoria e modernização do desempenho de todos os que exercem funções neste setor, com vista ao aperfeiçoamento da qualidade e utilidade dos seus serviços. Este trabalho reúne o conjunto de informação técnica presente na legislação e normas de forma a preencher a eventual falha do conhecimento neste ramo por parte destes profissionais dotando-os de um conhecimento mais aprofundado, de modo a que possam executar corretamente e de forma eficaz o seu trabalho. Por outro lado, esta dissertação tem como objetivo o projeto e desenvolvimento de uma rede de distribuição de gás natural aplicado a três redes concretas: rede de distribuição, edifício e moradia. A conceção do projeto de instalação de gás inicia-se com a recolha de informação, seguindo-se o desenvolvimento do estudo do traçado. Assim, estão reunidas as condições para dimensionar e providenciar a escolha de materiais mais adequados para a execução da obra. A metodologia de dimensionamento adotada teve por base a equação dos gases perfeitos e a fórmula de Renouard simplificada, encontrando-se implementada numa folha de cálculo. Esta ferramenta de cálculo aliada à metodologia permite realizar de forma expedita o correto dimensionamento de uma rede de gás, bem como apurar se a velocidade de escoamento se encontra em conformidade com o definido no projeto.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Esta dissertação teve como objetivo fundamental a otimização energética do sistema de refrigeração da máquina de impregnar tela ZELL e, como objetivo adicional, a avaliação da qualidade da água do circuito, justificada pela acentuada degradação dos rolos devido à corrosão provocada pela recirculação da água de arrefecimento. Inicialmente fez-se o levantamento de informações do processo produtivo para caracterizar o funcionamento do sistema de refrigeração, tendo-se selecionado duas telas de poliéster designadas neste estudo por P1 e P2 e, também, uma tela de nylon designada por N. Foram efetuados ensaios, um para cada tela, para a atual temperatura de setpoint da água à saída da torre de arrefecimento (30ºC). Realizou-se outro ensaio para a tela N mas com uma temperatura de setpoint de 37ºC, ao qual se chamou N37. Deste modo, determinou-se as potências térmicas removidas pela água de refrigeração e as potências térmicas perdidas por radiação e por convecção, tendo-se verificado que na generalidade dos rolos as referências P1 e P2 apresentam valores mais elevados. Em termos percentuais, a potência térmica removida pela água de refrigeração nos grupos tratores 1 e 3 e no conjunto de rolos de R1 a R29 corresponde a 48%, 10% e 70%, respetivamente. Com a avaliação às necessidades de arrefecimento da máquina ZELL, confirmou-se que os caudais atuais de refrigeração dos rolos garantem condições, mais que suficientes, de funcionamento dos rolamentos. Assim sendo, fez-se uma análise no sentido da diminuição do caudal total que passou de 10,25 L/s para 7,65 L/s. Considerando esta redução, determinou-se o caudal de ar húmido a ser introduzido na torre de arrefecimento. O valor determinado foi de 4,6 m3ar húmido/s, o que corresponde a uma redução de cerca de 32% em relação ao caudal atual que é de 6,8 m3ar húmido/s. Com os resultados das análises efetuadas à água do circuito de refrigeração, concluiu-se que a água de reposição e a água de recirculação possuem má qualidade para uso na generalidade dos sistemas de refrigeração, principalmente devido aos elevados valores de concentração de ferro e condutividade elétrica, responsáveis pela intensificação da corrosão no interior dos rolos.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A dependência energética das grandes economias mundiais, alertaram o mundo para a necessidade de mudar o comportamento relativo ao consumo de energia. O sector dos edifícios representa 40% dos consumos globais de energia na União Europeia, já no panorama nacional, o sector dos edifícios representa 28% dos consumos globais da energia, constituindo uma parte significativa no consumo global de energia, sendo portanto, essencial avaliar o desempenho energético dos edifícios, no sentido de promover a sua eficiência energética e beneficiar do grande potencial de economia de energia. Portugal à luz das linhas de orientação da União Europeia com o objectivo de instigar o aumento da eficiência energética nos edifícios, lançou o programa nacional para a eficiência energética nos Edifícios (P3E). Posteriormente, da transposição da Directiva 2002/91/CE para a ordem jurídica nacional surgiu o SCE, o RCCTE e o RSECE. Já em 2013, com a necessidade de transpor para a ordem da jurídica nacional a Directiva n.º 2010/31/EU, surge o Decreto-Lei n.º 118/2013, reunindo num só diploma o SCE, o REH e o RECS, promovendo uma revisão da legislação nacional, garantindo e promovendo a melhoria do desempenho energético dos edifícios. Através da presente dissertação, pretende-se avaliar o desempenho energético de uma pequena fracção de serviços existente tendo por base a metodologia regulamentar revogada do RSECE e a vigente metodologia regulamentar do RECS. Após apresentação dos dois regulamentos e da identificação das principais diferenças entre as duas metodologias regulamentares, procedeu-se ao enquadramento da fracção em estudo no âmbito de aplicação do RSECE e do RECS. Segundo os dois regulamentos a fracção não está sujeita a requisitos mínimos de qualidade térmica, nem a quaisquer requisitos energéticos e de eficiência dos sistemas técnicos, ao tratar-se de uma pequena fracção de serviços existente. Recorrendo ao software DesignBuilder, gerou-se o modelo da fracção em estudo, que através da simulação dinâmica multizona permitiu obter os consumos de energia anuais e a sua desagregação por utilização final. A partir dos consumos energia, determinaram-se os indicadores de eficiência energética de acordo com as duas metodologias, permitindo deste modo, proceder à classificação energética da fracção em estudo. De acordo com o RSECE a fracção em estudo obteve a classificação D, já segundo o RECS alcançou a classe C. Para aumentar a eficiência energética da fracção e consequentemente diminuir o consumo energético, foi proposto proceder à substituição das lâmpadas existentes por lâmpadas tubulares de tecnologia LED e à substituição do sistema de ventilação mecânico por um sistema de ventilação dimensionado para os novos valores de caudal de ar novo regulamentares. Com a implementação destas duas medidas a fracção em estudo melhoraria a sua classificação energética, exigindo um investimento baixo e apresentando um período de retorno de 1 ano e 5 meses. Segundo o RSECE passaria para a classe B, e aplicando a metodologia regulamentar do RECS alcançaria a classe B-.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A turvação é uma das principais preocupações das empresas de rede de distribuição de água potável. Para se saber a sua origem existem diversos mecanismos, sugeridos em bibliografia, que explicam a formação de depósitos de partículas nas tubagens, que se acumulam em camadas sobrepostas, criando entre si forças de coesão. A turvação pode surgir se o caudal ou a velocidade na tubagem aumentar, por alguma razão, pois um aumento da tensão de corte sobre o depósito, pode superar as forças de coesão levando à sua ressuspensão. Esta explicação é traduzida matematicamente pelo modelo PODDS (Prediction of Discolouration in Drinking Water Distribtuion System). O modelo PODDS foi compilado em EPANET recentemente por uma equipa de investigadores da Universidade de Sheffield e foi utilizado para fazer o estudo num ramal da empresa AdDP - Águas do Douro e Paiva, SA. Os resultados das simulações permitirão prever o caudal mínimo teórico a utilizar no ramal que origina o valor limite de turvação. Foram realizados ensaios de variação do caudal no ramal de Jovim-Ramalde para a calibração do modelo. Os parâmetros obtidos foram: Cmáx igual a 100 NTUm, b e n igual a 1, k é igual -1 NTUm3/N, e por fim, P igual a 0,0001 NTUm3/N.s. Após calibração do modelo realizaram-se simulações com atualização das forças de coesão para conhecer o caudal que provocaria a mobilização das partículas até uma turvação de 4 NTU e concluiu-se que o valor seria de 4,32 m3/s. O tempo necessário para regressar a valores inferiores a 1 NTU também foi determinado e 4 horas e 8 minutos foi o valor alcançado. Por fim realizou-se um estudo da influência da temperatura neste modelo e o resultado mostrou que este parâmetro é pouco influente para a gama de temperaturas considerada.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

PURPOSE: This study was designed to compare baseline data and clinical outcome between patients with prostate enlargement/benign prostatic hyperplasia (PE/BPH) who underwent unilateral and bilateral prostatic arterial embolization (PAE) for the relief of lower urinary tract symptoms (LUTS). METHODS: This single-center, ambispective cohort study compared 122 consecutive patients (mean age 66.7 years) with unilateral versus bilateral PAE from March 2009 to December 2011. Selective PAE was performed with 100- and 200-μm nonspherical polyvinyl alcohol (PVA) particles by a unilateral femoral approach. RESULTS: Bilateral PAE was performed in 103 (84.4 %) patients (group A). The remaining 19 (15.6 %) patients underwent unilateral PAE (group B). Mean follow-up time was 6.7 months in group A and 7.3 months in group B. Mean prostate volume, PSA, International prostate symptom score/quality of life (IPSS/QoL) and post-void residual volume (PVR) reduction, and peak flow rate (Qmax) improvement were 19.4 mL, 1.68 ng/mL, 11.8/2.0 points, 32.9 mL, and 3.9 mL/s in group A and 11.5 mL, 1.98 ng/mL, 8.9/1.4 points, 53.8 mL, and 4.58 mL/s in group B. Poor clinical outcome was observed in 24.3 % of patients from group A and 47.4 % from group B (p = 0.04). CONCLUSIONS: PAE is a safe and effective technique that can induce 48 % improvement in the IPSS score and a prostate volume reduction of 19 %, with good clinical outcome in up to 75 % of treated patients. Bilateral PAE seems to lead to better clinical results; however, up to 50 % of patients after unilateral PAE may have a good clinical outcome.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

O tratamento das águas residuais domésticas surge com o intuito de degradar os poluentes presentes, para que as águas residuais tratadas não prejudiquem o ambiente nem a saúde pública. O presente trabalho teve como objetivo a conceção e o dimensionamento de uma Estação de Tratamento de Águas Residuais (ETAR) na freguesia de Canelas com a finalidade de substituir a já existente e permitir a ampliação da área da rede de saneamento da freguesia. Foram considerados dois tipos de ETAR’s, compacta e convencional, para tratar águas residuais domésticas de aproxidamente 2000 habitantes, com um caudal médio de 400 m3/dia e um caudal de ponta de 1136,7 m3/dia. Das duas opções optou-se pela convencional uma vez que acarreta um menor investimento, no valor de 187 232 €, e se considera também mais adequada às características do efluente a tratar. O tratamento escolhido inclui inicialmente uma gradagem, com uma grade constituída por sete barras com um espaçamento de 20 mm entre elas, seguida de um tamisador rotativo com uma abertura de malha de 3 mm. Depois do tamisador, optou-se por um sistema de desarenação/desengorduramento com um volume do tanque de 3,95 m3 e um fluxo de ar de 17,9 m3/h. Na fase seguinte considerou-se um tratamento biológico por lamas ativadas em regime de arejamento prolongado num tanque de arejamento de volume igual a 245,8 m3 com um arejador submerso, seguindo-se um decantador secundário de volume 33,3 m3. Por último, escolheu-se um sistema de desinfeção por ultravioleta e, a montante do mesmo, um filtro rápido para eliminar pequenas partículas que o efluente ainda possa conter. Para a desinfeção foram consideradas duas secções com cinco módulos de duas lâmpadas cada, ou seja, vinte lâmpadas ultravioleta. Dos resíduos produzidos pelo tratamento da água residual, os gradados e as areias serão encaminhados para aterro, enquanto que as lamas serão enviadas para a ETAR das Termas de S.Vicente, para que sofram o tratamento adequado e sejam encaminhadas para o destinal final adequado (aplicação em solos agrícolas, compostagem ou em alternativa para aterro). No caso da ETAR covencional foi ainda avaliada a possível reutilização de um decantador da ETAR de Milhundos uma vez que esta se encontrava em fase de desativação. Desta avaliação, concluiu-se que não seria economicamente viável o seu reaproveitamento. Mestrado em Engenharia Química – Tecnologias de Proteção Ambiental Para além disso realizou-se também um levantamento dos principais problemas que ocorrem na maioria das ETAR’s e foram apresentadas as respetivas sugestões de resolução. A realização de um inquérito permititu concluir que os odores são o problema que mais causa incómodo à população.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A procura por alternativas ao atual paradigma energético, que se caracteriza por uma predominância indiscutível das fontes combustíveis fósseis, é o motivo primário desta investigação. A energia emitida pelo Sol que chega à Terra diariamente ultrapassa em várias ordens de grandeza a energia que a nossa sociedade atual necessita. O efeito chaminé é uma das formas de aproveitar essa energia. Este efeito tem origem no diferencial de temperaturas existente entre o interior e o exterior de uma chaminé, que provoca um gradiente nas massas volúmicas do fluido entre o interior e o exterior da chaminé, induzindo assim um fluxo de ar. Esta diferença de temperaturas radica na exposição da face exterior da chaminé à radiação solar. No sistema que nos propomos estudar, o ar entra na chaminé por pequenos orifícios situados na sua base, e, ao tomar contacto com as paredes internas da chaminé, aquece desde a temperatura ambiente, Ta, até à temperatura interna, Ti . Este aumento de temperatura torna o ar dentro da chaminé mais “leve” em comparação com o ar mais frio do exterior levando-o a ascender ao longo do interior da chaminé. Este escoamento contém energia cinética que pode, por exemplo, ser transformada em energia elétrica por intermédio de turbinas. A eficiência de conversão da energia será tanto maior quanto menor for a velocidade do ar a jusante da turbina. Esta tecnologia poderá ser instalada de forma descentralizada, como acontece com as atuais centrais concentradoras solares térmicas e fotovoltaicas localizadas na periferia de grandes cidades ou, alternativamente, poderá ser inserida no próprio tecido urbanístico. A investigação demonstra que as dimensões da chaminé, a irradiação e a temperatura do ar são os fatores com maior impacto na potência hidráulica gerada.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Dissertation presented to Faculdade de Ciências e Tecnologia, Universidade Nova de Lisboa for obtaining the master degree in Membrane Engineering

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This study focus in the valorization of the apple pomace with the main goal of obtaining added value products. For that, hot compressed water technology was used for the extraction of phenolic compounds and hydrolysis of polysaccharides presents in the lignocellulosic structure of apple pomace to obtain simple sugars. The sugars have been utilized as alternative carbon source for growth, lipid accumulation and carotenoids production by five different yeast Yarrowia lipolytica, Rhodotorula mucilaginosa, Rhodotorula glutinis, Rhodosporidium babjevae and Rhodosporidium toruloides. Hydrolysis experiments were carried out with constant pressure of 100 bar, flow rate of 2mL/min and temperatures between 50°C and 250°C. The amount of total sugars present in apple pomace hydrolysates showed maximum values for the hydrolysis temperatures of 110°C and 190°C. In fact, these temperatures revealed the best results regarding the monosaccharides quantities. The amount of 5-HMF and furfural in each hydrolysate varied through the different temperatures. Maximum values for 5-HMF were obtained with 170°C, while furfural showed to be maximum at 210°C. Extraction of phenolic compounds were performed in simultaneously with hydrolysis reactions. Total phenolic compounds (TPC) increased along the temperature, however with small variations between 170°C and 250°C. Hydrolysates were then used as alternative carbon source to yeast growth. R. mucilaginosa shows the highest optical density, with the hydrolysate obtained at 130°C. Carotenoids produced by these yeast scored a total of 7.02μg carotenoids/g cell dry weight, while for the control assay, the same yeast scored 9.31μg caratonoides/g cell dry weight. β-carotene was quantified by HPLC, were 33% of the carotenoid production by R. mucilaginosa with hydrolysate as carbon source, corresponded to β-caroteno.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Due to the fact that different injection molding conditions tailor the mechanical response of the thermoplastic material, such effect must be considered earlier in the product development process. The existing approaches implemented in different commercial software solutions are very limited in their capabilities to estimate the influence of processing conditions on the mechanical properties. Thus, the accuracy of predictive simulations could be improved. In this study, we demonstrate how to establish straightforward processing-impact property relationships of talc-filled injection-molded polypropylene disc-shaped parts by assessing the thermomechanical environment (TME). To investigate the relationship between impact properties and the key operative variables (flow rate, melt and mold temperature, and holding pressure), the design of experiments approach was applied to systematically vary the TME of molded samples. The TME is characterized on computer flow simulation outputsanddefined bytwo thermomechanical indices (TMI): the cooling index (CI; associated to the core features) and the thermo-stress index (TSI; related to the skin features). The TMI methodology coupled to an integrated simulation program has been developed as a tool to predict the impact response. The dynamic impact properties (peak force, peak energy, and puncture energy) were evaluated using instrumented falling weight impact tests and were all found to be similarly affected by the imposed TME. The most important molding parameters affecting the impact properties were found to be the processing temperatures (melt andmold). CI revealed greater importance for the impact response than TSI. The developed integrative tool provided truthful predictions for the envisaged impact properties.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Dissertação de mestrado integrado em Biomedical Engineering Biomaterials, Biomechanics and Rehabilitation

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Dissertação de mestrado integrado em Engenharia Civil

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Dissertação de mestrado em Técnicas de Caraterização e Análise Química