1000 resultados para Acoustic imaging


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To assess the usefulness of Doppler tissue imaging (DTI) for evaluating the systolic function of chagasic patients with and without electrocardiographic abnormalities, in comparision with echocardiographic study. METHODS: We studied 77 patients divided into 3 groups as follows: group 1 - control; group 2 - chagasic patients with normal electrocardiographic findings; and group 3 - chagasic patients with abnormal electrocardiographic findings. The following parameters were assessed: left ventricular dimensions and ejection fraction, left atrial dimensions and diastolic function on echocardiography. Systolic velocity and regional isovolumic contraction time (IVCTr) of the septal, anterior, lateral, posterior and inferior left ventricular walls were assessed on DTI. RESULTS: Left ventricular cavitary dimensions, ejection fraction and DTI systolic wave showed significant differences between groups 1 and 3 and between groups 2 and 3, which were not found between groups 1 and 2. IVCTr allowed a statistically significant discrimination among the 3 groups. CONCLUSION: DTI allowed discrimination among the different groups assessed, being superior to echocardiography in identifying early abnormalities of contractility, and, therefore, potentially useful for detecting incipient myocardial alterations in chagasic patients with normal electrocardiographic findings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

El control de propiedades hidrodinámicas capaces de influir en la mecánica de ruptura y poración de sistemas lamelares o membranas es de fundamental interés para diferentes aplicaciones biotecnológicas. Resulta de particular interés la conexión entre los procesos microscópicos relacionados al tipo de moléculas o unidades básicas, el orden determinado en el auto-ensamblado de las mismas y la dinámica local del sistema, con las propiedades físicas que determinan el comportamiento macroscópico bajo estimulación acústica. Resultados logrados recientemente sugieren la existencia de resonancias hidrodinámicas que podrian ser utilizadas para lograr la inestabilidad del sistema a baja potencia acústica. Se realizaran estudios experimentales utilizando principalmente técnicas que combinan resonancia magnética nuclear (RMN) y la sonicación de la muestra. También se realizarán estudios teóricos y simulaciones numéricas que permitan modelar los sistemas bajo estudio. Se propone dar continuidad al desarrollo de una técnica de relaxometría magnética nuclear en la cual se estimula acústicamente a la muestra durante el proceso de relajación magnética nuclear, y continuar la implementación de técnicas de RMN con resolución espacial que permitan complementar los estudios mencionados. Se espera comprender los mecanismos físicos que determinan la estabilidad de fases lamelares, logrando un modelo verificable y consistente que permita relacionar las propiedades mecánicas e hidrodinámicas con las propiedades de orden y dinámica molecular. Asimismo, se espera lograr avances en el desarrollo de las técnicas experimentales involucradas. La importancia del proyecto radica en el enfoque del problema. A diferencia de casi la totalidad de los estudios reportados, nuestro interés se enfoca en mecanismos de interacción entre la membrana y el campo acústico que sean eficientes a baja potencia acústica, en un régimen donde los gradientes térmicos y la cavitación sean despreciables.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Surgeons may use a number of cutting instruments such as osteotomes and chisels to cut bone during an operative procedure. The initial loading of cortical bone during the cutting process results in the formation of microcracks in the vicinity of the cutting zone with main crack propagation to failure occuring with continued loading. When a material cracks, energy is emitted in the form of Acoustic Emission (AE) signals that spread in all directions, therefore, AE transducers can be used to monitor the occurrence and development of microcracking and crack propagation in cortical bone. In this research, number of AE signals (hits) and related parameters including amplitude, duration and absolute energy (abs-energy) were recorded during the indentation cutting process by a wedge blade on cortical bone specimens. The cutting force was also measured to correlate between load-displacement curves and the output from the AE sensor. The results from experiments show AE signals increase substantially during the loading just prior to fracture between 90% and 100% of maximum fracture load. Furthermore, an amplitude threshold value of 64dB (with approximate abs-energy of 1500 aJ) was established to saparate AE signals associated with microcracking (41 – 64dB) from fracture related signals (65 – 98dB). The results also demonstrated that the complete fracture event which had the highest duration value can be distinguished from other growing macrocracks which did not lead to catastrophic fracture. It was observed that the main crack initiation may be detected by capturing a high amplitude signal at a mean load value of 87% of maximum load and unsteady crack propagation may occur just prior to final fracture event at a mean load value of 96% of maximum load. The author concludes that the AE method is useful in understanding the crack initiation and fracture during the indentation cutting process.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Unidentified heart valve disease is associated with a significant morbidity and mortality. It has therefore become important to accurately identify, assess and monitor patients with this condition in order that appropriate and timely intervention can occur. Although echocardiography has emerged as the predominant imaging modality for this purpose, recent advances in cardiac magnetic resonance and cardiac computed tomography indicate that they may have an important contribution to make. The current review describes the assessment of regurgitant and stenotic heart valves by multimodality imaging (echocardiography, cardiac computed tomography and cardiac magnetic resonance) and discusses their relative strengths and weaknesses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Imaging microwave reconstruction dielectric contrast regularization iterative multiport cavity measurement

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Cardiac magnetic resonance imaging provides detailed anatomical information on infarction. However, few studies have investigated the association of these data with mortality after acute myocardial infarction. Objective: To study the association between data regarding infarct size and anatomy, as obtained from cardiac magnetic resonance imaging after acute myocardial infarction, and long-term mortality. Methods: A total of 1959 reports of “infarct size” were identified in 7119 cardiac magnetic resonance imaging studies, of which 420 had clinical and laboratory confirmation of previous myocardial infarction. The variables studied were the classic risk factors – left ventricular ejection fraction, categorized ventricular function, and location of acute myocardial infarction. Infarct size and acute myocardial infarction extent and transmurality were analyzed alone and together, using the variable named “MET-AMI”. The statistical analysis was carried out using the elastic net regularization, with the Cox model and survival trees. Results: The mean age was 62.3 ± 12 years, and 77.3% were males. During the mean follow-up of 6.4 ± 2.9 years, there were 76 deaths (18.1%). Serum creatinine, diabetes mellitus and previous myocardial infarction were independently associated with mortality. Age was the main explanatory factor. The cardiac magnetic resonance imaging variables independently associated with mortality were transmurality of acute myocardial infarction (p = 0.047), ventricular dysfunction (p = 0.0005) and infarcted size (p = 0.0005); the latter was the main explanatory variable for ischemic heart disease death. The MET-AMI variable was the most strongly associated with risk of ischemic heart disease death (HR: 16.04; 95%CI: 2.64-97.5; p = 0.003). Conclusion: The anatomical data of infarction, obtained from cardiac magnetic resonance imaging after acute myocardial infarction, were independently associated with long-term mortality, especially for ischemic heart disease death.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Independent Component Analysis, Time Series Analysis, Functional Magnetic Resonance Imaging

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Subsurface Radar, Ground Penetrating Radar (GPR), Synthetic Aperture Radar (SAR), Anti-Personnel Landmine, Antenna Desing, Field Simulation, Focusing, Dielectric Lens, Geophysics, Soil Properties

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AbstractBackground:Prone imaging has been demonstrated to minimize diaphragmatic and breast tissue attenuation.Objectives:To determine the role of prone imaging on the reduction of unnecessary rest perfusion studies and coronary angiographies performed, thus decreasing investigation time and radiation exposure.Methods:We examined 139 patients, 120 with an inferior wall and 19 with an anterior wall perfusion defect that might represented attenuation artifact. Post-stress images were acquired in both the supine and prone position. Coronary angiography was used as the “gold standard” for evaluating coronary artery patency. The study was terminated and rest imaging was obviated in the presence of complete improvement of the defect in the prone position. Quantitative interpretation was performed. Results were compared with clinical data and coronary angiographic findings.Results:Prone acquisition correctly revealed defect improvement in 89 patients (89/120) with inferior wall and 12 patients (12/19) with anterior wall attenuation artifact. Quantitative analysis demonstrated statistically significant difference in the mean summed stress scores (SSS) of supine and mean SSS of prone studies in patients with disappearing inferior wall defect in the prone position and patent right coronary artery (true negative results). The mean difference between SSS in supine and in prone position was higher with disappearing than with remaining defects.Conclusion:Technetium-99m (Tc-99m) tetrofosmin myocardial perfusion imaging with the patient in the prone position overcomes soft tissue attenuation; moreover it provides an inexpensive, accurate approach to limit the number of unnecessary rest perfusion studies and coronary angiographies performed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Magdeburg, Univ., Fak. für Elektrotechnik und Informationstechnik, Diss., 2009

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Magdeburg, Univ., Fak. für Naturwiss., Diss., 2013

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Magdeburg, Univ., Fak. für Elektrotechnik und Informationstechnik, Diss., 2015

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Magdeburg, Univ., Fak. für Naturwiss., Diss., 2015

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Los requisitos de los dispositivos empleados en los nuevos sistemas de telecomunicaciones son: unas avanzadas prestaciones, reducido tamaño y bajo coste. Actualmente, se utilizan filtros basados en la tecnología SAW para trabajar a frecuencias de microondas. Dado los inconvenientes que presentan dicho tipo de filtros, se pretende substituirlos por filtros basados en tecnología BAW. La topología en escalera es hasta el momento la más extendida para diseñar estos filtros.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hypoxia, a condition of insufficient oxygen availability to support metabolism, occurs when the vascular supply is interrupted, as in stroke. The identification of the hypoxic and viable tissue in stroke as compared with irreversible lesions (necrosis) has relevant implications for the treatment of ischemic stroke. Traditionally, imaging by positron emission tomography (PET), using 15O-based radiotracers, allowed the measurement of perfusion and oxygen extraction in stroke, providing important insights in its pathophysiology. However, these multitracer evaluations are of limited applicability in clinical settings. More recently, specific tracers have been developed, which accumulate with an inverse relationship to oxygen concentration and thus allow visualizing the hypoxic tissue non invasively. These belong to two main groups: nitroimidazoles, and among these the 18F-Fluoroimidazole (18F-FMISO) is the most widely used, and the copper-based tracers, represented mainly by Cu-ATSM. While these tracers have been at first developed and tested in order to image hypoxia in tumors, they have also shown promising results in stroke models and preliminary clinical studies in patients with cardiovascular disorders, allowing the detection of hypoxic tissue and the prediction of the extent of subsequent ischemia and clinical outcome. These tracers have therefore the potential to select an appropriate subgroup of patients who could benefit from a hypoxia-directed treatment and provide prognosis relevant imaging. The molecular imaging of hypoxia made important progress over the last decade and has a potential for integration into the diagnostic and therapeutic workup of patients with ischemic stroke.