877 resultados para Águas residuais - Purificação - Tratamento biológico
Resumo:
High fuel consumption and its inadequate control in fuel stations caused the pollution of soil and aquifers. These consequences created more concern with the increased exploration of aquifers to supply the groundwater demand. The objective of this study was to evaluate the eficiency and efectiveness of the of pump and treat technique of the water applied to the Coastal Aquifer in the cleaning up of the plumes produced by the leaking of fuel in the gas station Auto Posto Baía do Sol Ltda. The gas station is located in São Sebastião, in the north coast of São Paulo State. In the case of Auto Posto Baía do Sol Ltda., the technique of pump and treat was eficient and the plume produced by the leakage was completely removed. However, the efectiveness of this technique was low due to the long time required for the complete operation.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Pós-graduação em Zootecnia - FMVZ
Resumo:
Maintaining the levels of fluoride ion in public water supply within the parameters of adequacy it becomes essential so the measure carries a greater impact on caries prevention and control, without increasing the prevalence of dental fluorosis. Thus, it is necessary a rigorous control of the process, avoiding the undesired effects at levels above recommended levels, as well as avoiding levels below the recommended that do not offer the highest benefit. The aim of this study was to analyze the content of fluoride in public water supply in the city of Birigui, SP, with different sources of supply, checking if the fluoride levels are within the recommended. The samples were collected monthly from points previously established, with the knowledge of the distribution network of water and identifying the amount and location of supply sources and water treatment plant. Analyses were performed in duplicate in the period from January to December of 2009, in the laboratory - NEPESCO - of the Dental School of Araçatuba, Univ Estadual Paulista – UNESP, using an ion analyzer coupled to a specific electrode for fluoride. Of the total samples (n = 512), 44% (n = 224) had adequate levels and 56% (n = 288) inadequate levels, 10% (n = 49) lower levels and 46% (n = 239) showed levels above the recommended. There were differences in results when comparing the analysis of different sources. The fluoride concentration in the majority of the samples from deep wells was classified as inadequate not offering the desired benefit, or exposing the population to the risk of dental fluorosis.
Resumo:
Water quality is very important for the health and the population welfare, and the public supply system must provide water quality and suffi cient quantity for the entire population. Water treatment stations, are the main way to obtain water quality. When this doesn’t occur, several problems can affect the population, in this case, using water with poor quality is a constant risk of emergence causing various diseases. The elimination of microorganisms in treated water reduces competition, encouraging the multiplication of chlorine resistant bacteria as Mycobacterium genus frequently isolated from treated and chlorinated water. Considering the lack of indication from examinations of mycobacteria routine laboratory for quality control of drinking water and other human uses, the objective was to verify the presence isolate and identify the environmental mycobacteria in the system water source surface of Araraquara - SP. We analyzed 40 water samples, distributed as follows: ten water gross collected at Station Water Treatment Plant (WTP), harvested after ten fi ltration; ten collected in the reservoir after chlorination and ten in the network distribution. Were recovered 43 isolates of mycobacteria. All isolates were subjected to PCR-PRA. The mycobacteria were identifi ed as M. lentifl avum, M. parafortuitum, M. genavense, M. gordonae, M. fortuitum, M. confl uent, M. duvalii, M. avium subspecies paratuberculosis and M. szulgai. With these results, was concluded that water is an important source of environmental mycobacteria probably related to several human diseases, suggesting the carrying out continuous monitoring of the microorganisms in the system drinking water.
Resumo:
This paper aimed to study the treatability of rainwater using natural coagulant tannin based. Assays were performed in laboratory scale and aimed to study the conditions most suitable for dosage and for pH of coagulation. Preliminary tests indicated that tannin concentration of 3% (m/m) prepared from the commercial solution presented the best set of results (84.3% of removal for apparent color and 82.51% for turbidity) compared to ferric chloride (66.25% of removal for apparent color and 67.82% for turbidity) and starch (73.68% of removal for apparent color and 67.19% for turbidity). The coagulation diagrams indicate that the best region for dosage ranges from 15 mg/L to about 37.5 mg/L and for pH ranging from about 6.5 to 7.5. The results indicate that the tannin based natural coagulant may be an alternative to conventional coagulants for rainwater treatment seeking non potable uses.
Resumo:
The purpose of a water treatment plant (WTP) is to provide quality water to the population in the municipality where it is operate, being directly linked to the health of the community. The efficiency of a water treatment is directly related to the quality and reliability of the methods used. The analytical results of any laboratory test or calibration is a critical process for any company today. A tool used to assist in a quality management system process is ISO/IEC 17025:2005. Given the above, the objective of this study was to evaluate the performance of an ETA located in Lençóis Paulista-SP, using the analytical results obtained by physical, chemical and microbiological determinations in the period 1-30 October 2015. Such determinations are grounded in compliance with current Ordinance 2914 the Ministry of Health and the Quality Management System, which is required for all laboratories carrying out laboratory tests for control and surveillance of water quality for human consumption
Resumo:
Mastits is considered uncommon disease in mares. Streptococcus equi, Staphylococcus sp., Corynebacterium sp., Actinobacillus sp., Nocardia sp. and enterobacterias are major microorganisms involved in equine mammary infections. The disease is commonly related to traumatic lesions in mammary glands and teats. Edema, fibrosis, masses to palpation of glands, and viscous to seropurulent milk are mainly clinical signs observed in affected animals. The diagnosis is based on clinical exam of mammary glands and microbiological culture of the milk. There are no standard to use of indirect exams on diagnosis, including California Mastits Test and Somatic Cell Count. Systemic antimicrobials are recommended in therapy, based on previous “in vitro” susceptibility microbiological test. No specific control measures are indicated in equine mastits. The present study reviewed the mastits in mares, with emphasis to etiology, epidemiology findings, clinical manifestation, diagnosis, treatment and control aspects.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Microbiologia Agropecuária - FCAV
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
A VDAC é uma porina presente na MME cuja função é crucial no metabolismo energético, sobrevivência e morte celular. A caracterização da VDAC torna-se importante para a compreensão das inter-relações da mitocôndria com os diferentes componentes citosólicos, tais como a HK. A ligação HK-VDAC favorece a utilização do ATP intramitocondrial em células neuronais, a HK cerebral pode interagir de formas diferentes com a VDAC, o que resulta em diferentes sítios de ligação (sítios A e B). Os variados papéis metabólicos das isoformas da VDAC podem ser explicados pela presença de alterações pós-traducionais. No presente trabalho purificamos a VDAC1 mitocondrial neuronal proveniente de cérebro aviar. Paralelamente, comprovamos que a presença de múltiplas formas das VDACs 1 e 2 em cérebros murino e aviar, seja devida à presença de modificações pós-traducionais, nomeadamente a fosforilação. A proteína isolada apresentou peso molecular de 30KDa. Quando submetida à eletroforese e posteriormente à coloração para a identificação de fosfoproteínas, a mesma mostrou-se desfosforilada. O conhecimento da presença, ou ausência de fosforilação das VDACs, reside na importância de estabelecer-se as bases moleculares ligadas à existência de sítios A e B nas mitocôndrias neuronais.
Resumo:
Objetivou-se analisar potencialidades e limites da estratégia do tratamento supervisionado (DOTS) para a tuberculose, sob a percepção de usuários em tratamento e de trabalhadores de saúde de uma supervisão técnica de saúde do município de São Paulo. Entrevistaram-se 4 usuários e 17 profissionais de saúde de nove unidades básicas de saúde, entre abril e junho de 2006, após consentimento livre e esclarecido. Os depoimentos foram decodificados segundo a técnica de análise de discurso. Adotou-se a teoria da determinação social do processo saúde/doença como referencial teórico. Foram potencialidades: criação de vínculo entre profissional/usuário e incentivos ao tratamento, o que favorece a adesão. Foram limites: restrito envolvimento dos profissionais no DOTS e conciliar horário de trabalho do usuário com a supervisão. Reitera-se que a adesão ao tratamento transcende o âmbito biológico, sendo fundamental que os trabalhadores de saúde reconheçam os usuários como portadores de necessidades, não se restringindo apenas à supervisão da tomada de medicamentos.