899 resultados para vector filtering
Resumo:
The total cross-section for the dd → 4HeK+K− reaction has been measured at a beam momentum of 3.7GeV/c, corresponding to an excess energy of 39MeV, which is the maximum possible atthe Cooler Synchrotron COSY-Jülich. A deuterium cluster-jet target and the ANKE forward magnetic spectrometer, placed inside the storage ring, have been employed in this investigation. We find a total cross-section of σtot < 14 pb, which brings into question the viability of investigating the dd → 4He a0(980)reaction as a means of studying isospin violation.
Resumo:
The discrepancy between the PQCD calculation and the CLEO data for chi (c1)->gamma V (V=rho (0), omega, phi) stimulates our interest in exploring other mechanisms of chi (c1) decay. In this work, we apply an important non-perturbative QCD effect, i.e., the hadronic loop mechanism, to study chi (c1)->gamma V radiative decay. Our numerical result shows that the theoretical results including the hadronic loop contribution and the PQCD calculation of chi (c1)->gamma V are consistent with the corresponding CLEO data of chi (c1)->gamma V. We expect further experimental measurement of chi (c1)->gamma V, which will be helpful to test the hadronic loop effect on chi (c1) decay.
Resumo:
Beijing University of Technology (BJUT); Beijing Municipal Lab of Brain Informatics; Chinese Society of Radiology; National Natural Science Foundation of China (NSFC); State Administration of Foreign Experts Affairs
Resumo:
In this paper, we evaluated various parameters of culture condition affecting high-level soluble expression of human cyclin A, in Escherichia coli BL21(DE3), and demonstrated that the highest protein yield was obtained using TB(no glycerol) + 0.5% glucose medium at 25 degrees C. By single immobilized metal ion affinity chromatography, we got highly purified human cyclin A(2) with a yield ranged from 20 to 30 mg/L. By amyloid-diagnostic dye ThT binding and Fourier transform infrared spectroscopy, we observed a significant decrease in alpha-helix content and an increase in beta-sheet structure in cyclin A(2) inclusion body in comparison to its native protein, and confirmed the resemblance of the internal organization of cyclin A(2) inclusion body and amyloid fibrils.
Resumo:
The potential of Kalman filtering for indication of unexpected components in a mixture was experimentally evaluated by taking the spectrofluorimetric analysis of the tricomponent system;oi phenylalanine, tryhtophen and tyrosine as an example. According to
Resumo:
The performance of Kalman filtering, synchronous excitation and numerical derivative techniques for the resolution of overlapping emission spectra in spectrofluorimetry was studied. The extent of spectrum overlap was quantitatively described by the separation degree D(s), defined as the ratio of the peak separation to the full width at half-maximum of the emission spectrum of the interferent. For the system of Rhodamine B and Rhodamine 6G with a large D(s) of about 0.4, both Kalman filtering and synchronous techniques are able to resolve the overlapping spectra well and to give satisfactory results while the derivative spectra are still overlapped with each other. Moreover, the sensitivities are greatly decreased in derivative techniques. For more closely spaced spectra emitted by the complexes of Al and Zn with 7-iodo-8-hydroxyquinoline-5-sulphonic acid (Ferron)-hexadecyltrimethylammonium bromide, the synchronous excitation technique cannot completely separate the overlapping peaks, although it increases the separation degree from 0.25 in the conventional spectra to 0.37 in the synchronous spectra. On the other hand, Kalman filtering is capable of resolving this system. When the Al/Zn intensity ratio at the central wavelength of Al was > 1, however, the accuracy and precision of the estimates for Zn concentration produced by the Kalman filter became worse. In this event, the combination of synchronous excitation and Kalman filtering can much improve the analytical results.
Resumo:
Effects of some factors on the performance of our Kalman filter in discrimination of closely spaced overlapping signals were investigated. The resolution power of the filter for overlapping lines can be strengthened by reduction of the step size in scans. The minimum peak separation of two lines which the Kalman filter can effectively handle generally equals two to three times the step size in scans. Significant difference between the profiles of the analysis and interfering lines and multiple lines from matrix in the spectral window of the analysis line are very helpful for the Kalman filter to discern closely spaced analysis and interfering signals correctly, which allow the filter well to resolve the line pair with very small peak distance or even the entirely coincident lines.
Resumo:
A Kalman filter was developed for resolving overlapping lines in inductively coupled plasma atomic emission spectrometry (ICP-AES) and evaluated experimentally with the determination of La in the presence of Ho, and Cu in the presence of Pr. The whiteness of the innovation sequence for an optimal filter was explored to be the criterion for the correction of the wavelength positioning errors which may occur in spectral scans. Under the conditions of the medium-resolution spectrometer and 1.5 pm step size in scans, the filter effectively resolved the Cu/Pr line pair having a small peak separation of 4.8 pm. For the La/Ho line pair with a peak distance of 9.8 pm, an unbiased estimate for La concentration was still obtained even when the signal-to-background ratio was down to 0.048. Favourable detection limits for real samples were achieved. Unstructured backgrounds were modeled theoretically and all spectral scans therefore did not require the correction for solvent.
Resumo:
This paper deals with the evaluation of the reliability of the analytical results obtained by Kalman filtering. Two criteria for evaluation were compared: one is based on the autocorrelation analysis of the innovation sequence, the so-called NAC criterion; the other is the innovations number, which actually is the autocorrelation coefficient of the innovation sequence at the initial wavelength. Both criteria allow compensation for the wavelength positioning errors in spectral scans, but there exists a difference in the way they work. The NAC criterion can provide information about the reliability of an individual result, which is very useful for the indication of unmodelled emissions, while the innovations number should be incorporated with the normalization of the innovations or seek the help of the sequence itself for the same purpose. The major limitation of the NAC criterion is that it does not allow the theoretical modelling of continuous backgrounds, which, however, is convenient in practical analysis and can be taken with the innovations number criterion.
Resumo:
This work evaluates the effect of wavelength positioning errors in spectral scans on analytical results when the Kalman filtering technique is used for the correction of line interferences in inductively coupled plasma atomic emission spectrometry (ICP-AES). The results show that a positioning accuracy of 0.1 pm is required in order to obtain accurate and precise estimates for analyte concentrations. The positioning error in sample scans is more crucial than that in model scans. The relative bias in measured analyte concentration originating from a positioning error in a sample scan increases linearly with an increase in the magnitude of the error and the peak distance of the overlapping lines, but is inversely proportional to the signal-to-background ratio. By the use of an optimization procedure for the positions of scans with the innovations number as the criterion, the wavelength positioning error can be reduced and, correspondingly, the accuracy and precision of analytical results improved.