930 resultados para transient thermal distortion analysis
Resumo:
The major objective of this work was to evaluate the potential of image analysis for characterizing air voids in Portland cement Concrete (PCC), voids and constituents of Asphalt Concrete (AC) and aggregate gradation in AC. Images for analysis were obtained from a scanning electron microscope (SEM). Sample preparation techniques are presented that enhance signal differences so that backscattered electron (BSE) imaging, which is sensitive to atomic number changes, can be effectively employed. Work with PCC and AC pavement core samples has shown that the low vacuum scanning electron microscope (LVSEM) is better suited towards rapid analyses. The conventional high vacuum SEM can also be used for AC and PCC analyses but some distortion within the sample matrix will occur. Images with improved resolution can be obtained from scanning electron microscope (SEM) backscatter electron (BSE) micrographs. In a BSE image, voids filled with barium sulfate/resin yield excellent contrast in both PCC and AC. There is a good correlation between percent of air by image analysis and linear traverse.
Resumo:
Recent ink dating methods focused mainly on changes in solvent amounts occurring over time. A promising method was developed at the Landeskriminalamt of Munich using thermal desorption (TD) followed by gas chromatography / mass spectrometry (GC/MS) analysis. Sequential extractions of the phenoxyethanol present in ballpoint pen ink entries were carried out at two different temperatures. This method is applied in forensic practice and is currently implemented in several laboratories participating to the InCID group (International Collaboration on Ink Dating). However, harmonization of the method between the laboratories proved to be a particularly sensitive and time consuming task. The main aim of this work was therefore to implement the TD-GC/MS method at the Bundeskriminalamt (Wiesbaden, Germany) in order to evaluate if results were comparable to those obtained in Munich. At first validation criteria such as limits of reliable measurements, linearity and repeatability were determined. Samples were prepared in three different laboratories using the same inks and analyzed using two TDS-GC/MS instruments (one in Munich and one in Wiesbaden). The inter- and intra-laboratory variability of the ageing parameter was determined and ageing curves were compared. While inks stored in similar conditions yielded comparable ageing curves, it was observed that significantly different storage conditions had an influence on the resulting ageing curves. Finally, interpretation models, such as thresholds and trend tests, were evaluated and discussed in view of the obtained results. Trend tests were considered more suitable than threshold models. As both approaches showed limitations, an alternative model, based on the slopes of the ageing curves, was also proposed.
Resumo:
Between the cities of Domodossola and Locarno, the complex ``Centovalli Line'' tectonic zone of the Central Alps outlines deformation phases over a long period of time (probably starting similar to 30 Ma ago) and under variable P-T conditions. The last deformation phases developed gouge-bearing faults with a general E-W trend that crosscuts the roots of the Alpine Canavese zone and the Finero ultramafic body. Kinematic indicators show that the general motion was mainly dextral associated with back thrusting towards the S. The <2 mu m clay fractions of fault gouges from Centovalli Line consist mainly of illite, smectite and chlorite with varied illite-smectite, chlorite-smectite and chlorite-serpentine mixed-layers. Constrained with the illite crystallinity index, the thermal conditions induced by the tectonic activity show a gradual trend from anchizonal to diagenetic conditions. The <2 and <0.2 mu M clay fractions, and hydrothermal K-feldspar separates all provide K-Ar ages between 14.2 +/- 2.9 Ma and roughly 0 Ma, with major episodes at about 12,8, 6 and close to 0 Ma These ages set the recurrent tectonic activity and the associated fluid circulations between Upper Miocene and Recent. On the basis of the K-Ar ages and with a thermal gradient of 25-30 degrees C/km, the studied fault zones were located at a depth of 4-7 km. If they were active until now as observed in field, the exhumation was approximately 2.5-3.0 km for the last 12 Ma with a mean velocity of 0.4 mm/y. Comparison with available models on the recent Alpine evolution shows that the tectonic activity in the area relates to a continuum of the back-thrusting movements of the Canavese Line, and/or to several late-extensional phases of the Rhone-Simplon line. The Centovalli-Val Vigezzo zone therefore represents a major tectonic zone of the Central-Western Alps resulting from different interacting tectonic events. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
Combined structural analysis and oxygen isotope thermometry of syntectonic quartz-calcite fibrous veins can be used to correlate the thermal history of deformed rocks,vith specific structural and tectonic events. Results are presented for the Mercies nappe in the western Helvetic Alps, Switzerland, where mineral parageneses, illite `'crystallinity,'' and fluid inclusion chemistry record an apparent peak metamorphic temperature gradient that increased across the Morcles nappe from anchizonal conditions in the foreland to epizonal conditions in its hinterland root zone. Twenty-seven quartz-calcite veins were analyzed in this study in order to determine the temperatures of veining during formation and deformation of the nappe, Peak metamorphic temperatures ranged from approximate to 260 to 290 degrees C in the shallower, foreland localities and to approximate to 330 to 350 degrees C in the deeper, more hinterland localities at the end of S1-foliation formation, related to large-scale folding. Temperatures gradually decreased throughout the nappe during subsequent development of the S2 foliation and S3 crenulation cleavage, Uplift and erosion of the overlying nappe pile resulted in slow cooling of the Morcles nappe during the waning stages of the Alpine Orogeny. The dominant foliation-forming deformation of the Morcles nappe occurred at elevated temperatures over the course of 10 to 15 Ma. Combined structure-oxygen isotope analyses of quartz-calcite veins yield better temperature and temporal constraints on the thermal histories of subgreenschist vein-bearing tectonites than do other geothermometers.
Resumo:
Mucosal immunity to the enteric pathogen Shigella flexneri is mediated by secretory IgA (S-IgA) antibodies directed against the O-antigen (O-Ag) side chain of lipopolysaccharide. While secretory antibodies against the O-Ag are known to prevent bacterial invasion of the intestinal epithelium, the mechanisms by which this occurs are not fully understood. In this study, we report that the binding of a murine monoclonal IgA (IgAC5) to the O-Ag of S. flexneri serotype 5a suppresses activity of the type 3 secretion (T3S) system, which is necessary for S. flexneri to gain entry into intestinal epithelial cells. IgAC5's effects on the T3S were rapid (5 to 15 min) and were coincident with a partial reduction in the bacterial membrane potential and a decrease in intracellular ATP levels. Activity of the T3S system returned to normal levels 45 to 90 min following antibody treatment, demonstrating that IgAC5's effects were transient. Nonetheless, these data suggest a model in which the association of IgA with the O-Ag of S. flexneri partially de-energizes the T3S system and temporarily renders the bacterium incapable of invading intestinal epithelial cells. IMPORTANCE: Secretory IgA (S-IgA) serves as the first line of defense against enteric infections. However, despite its well-recognized role in mucosal immunity, relatively little is known at the molecular level about how this class of antibody functions to prevent pathogenic bacteria from penetrating the epithelial barrier. It is generally assumed that S-IgA functions primarily by "immune exclusion," a phenomenon in which the antibody binds to microbial surface antigens and thereby promotes bacterial agglutination, entrapment in mucus, and physical clearance from the gastrointestinal tract via peristalsis. The results of the present study suggest that in addition to serving as a physical barrier, S-IgA may have a direct impact on the ability of microbial pathogens to secrete virulence factors required for invasion of intestinal epithelial cells.
Resumo:
Correspondència referida a l'article de R. Giannetti, publicat ibid. vol.49 p.87-88
Resumo:
The safe use of nuclear power plants (NPPs) requires a deep understanding of the functioning of physical processes and systems involved. Studies on thermal hydraulics have been carried out in various separate effects and integral test facilities at Lappeenranta University of Technology (LUT) either to ensure the functioning of safety systems of light water reactors (LWR) or to produce validation data for the computer codes used in safety analyses of NPPs. Several examples of safety studies on thermal hydraulics of the nuclear power plants are discussed. Studies are related to the physical phenomena existing in different processes in NPPs, such as rewetting of the fuel rods, emergency core cooling (ECC), natural circulation, small break loss-of-coolant accidents (SBLOCA), non-condensable gas release and transport, and passive safety systems. Studies on both VVER and advanced light water reactor (ALWR) systems are included. The set of cases include separate effects tests for understanding and modeling a single physical phenomenon, separate effects tests to study the behavior of a NPP component or a single system, and integral tests to study the behavior of the whole system. In the studies following steps can be found, not necessarily in the same study. Experimental studies as such have provided solutions to existing design problems. Experimental data have been created to validate a single model in a computer code. Validated models are used in various transient analyses of scaled facilities or NPPs. Integral test data are used to validate the computer codes as whole, to see how the implemented models work together in a code. In the final stage test results from the facilities are transferred to the NPP scale using computer codes. Some of the experiments have confirmed the expected behavior of the system or procedure to be studied; in some experiments there have been certain unexpected phenomena that have caused changes to the original design to avoid the recognized problems. This is the main motivation for experimental studies on thermal hydraulics of the NPP safety systems. Naturally the behavior of the new system designs have to be checked with experiments, but also the existing designs, if they are applied in the conditions that differ from what they were originally designed for. New procedures for existing reactors and new safety related systems have been developed for new nuclear power plant concepts. New experiments have been continuously needed.
Resumo:
Diplomityön tavoitteena on paineistimen yksityiskohtainen mallintaminen APROS- ja TRACE- termohydrauliikkaohjelmistoja käyttäen. Rakennetut paineistinmallit testattiin vertaamalla laskentatuloksia paineistimen täyttymistä, tyhjentymistä ja ruiskutusta käsittelevistä erilliskokeista saatuun mittausdataan. Tutkimuksen päätavoitteena on APROSin paineistinmallin validoiminen käyttäen vertailuaineistona PACTEL ATWS-koesarjan sopivia paineistinkokeita sekä MIT Pressurizer- ja Neptunus- erilliskokeita. Lisäksi rakennettiin malli Loviisan ydinvoimalaitoksen paineistimesta, jota käytettiin turbiinitrippitransientin simulointiin tarkoituksena selvittää mahdolliset voimalaitoksen ja koelaitteistojen mittakaavaerosta johtuvat vaikutukset APROSin paineistinlaskentaan. Kokeiden simuloinnissa testattiin erilaisia noodituksia ja mallinnusvaihtoehtoja, kuten entalpian ensimmäisen ja toisen kertaluvun diskretisointia, ja APROSin sekä TRACEn antamia tuloksia vertailtiin kattavasti toisiinsa. APROSin paineistinmallin lämmönsiirtokorrelaatioissa havaittiin merkittävä puute ja laskentatuloksiin saatiin huomattava parannus ottamalla käyttöön uusi seinämälauhtumismalli. Työssä tehdyt TRACE-simulaatiot ovat osa United States Nuclear Regulatory Commissionin kansainvälistä CAMP-koodinkehitys-ja validointiohjelmaa.
Resumo:
Uusi EPR-reaktorikonsepti on suunniteltu selviytymään tapauksista, joissa reaktorinsydän sulaa ja sula puhkaisee paineastian. Suojarakennuksen sisälle on suunniteltu alue, jolle sula passiivisesti kerätään, pidätetään ja jäähdytetään. Alueelle laaditaan valurautaelementeistä ns.sydänsieppari, joka tulvitetaan vedellä. Sydänsulan tuottama jälkilämpö siirtyyveteen, mistä se poistetaan suojarakennuksen jälkilämmönpoistojärjestelmän kautta. Suuri osa lämmöstä poistuu sydänsulasta sen yläpuolella olevaan veteen, mutta lämmönsiirron tehostamiseksi myös sydänsiepparin alapuolelle on sijoitettu vedellä täytettävät jäähdytyskanavat. Jotta sydänsiepparin toiminta voitaisiin todentaa, on Lappeenrannan Teknillisellä Yliopistolla rakennettu Volley-koelaitteisto tätä tarkoitusta varten. Koelaitteisto koostuu kahdesta täysimittaisesta valuraudasta tehdystä jäähdytyskanavasta. Sydänsulan tuottamaa jälkilämpöä simuloidaan koelaitteistossa sähkövastuksilla. Tässä työssä kuvataan simulaatioiden suorittaminen ja vertaillaan saatuja arvoja mittaustuloksiin. Työ keskittyy sydänsiepparista jäähdytyskanaviin tapahtuvan lämmönsiirron teoriaan jamekanismeihin. Työssä esitetään kolme erilaista korrelaatiota lämmönsiirtokertoimille allaskiehumisen tapauksessa. Nämä korrelaatiot soveltuvat erityisesti tapauksiin, joissa vain muutamia mittausparametreja on tiedossa. Työn toinen osa onVolley 04 -kokeiden simulointi. Ensin käytettyä simulointitapaa on kelpoistettuvertaamalla tuloksia Volley 04 ja 05 -kokeisiin, joissa koetta voitiin jatkaa tasapainotilaan ja joissa jäähdytteen käyttäytyminen jäähdytyskanavassa on tallennettu myös videokameralla. Näiden simulaatioiden tulokset ovat hyvin samanlaisiakuin mittaustulokset. Korkeammilla lämmitystehoilla kokeissa esiintyi vesi-iskuja, jotka rikkoivat videoinnin mahdollistavia ikkunoita. Tämän johdosta osassa Volley 04 -kokeita ikkunat peitettiin metallilevyillä. Joitakin kokeita jouduttiin keskeyttämään laitteiston suurten lämpöjännitysten johdosta. Tällaisten testien simulaatiot eivät ole yksinkertaisia suorittaa. Veden pinnan korkeudesta ei ole visuaalista havaintoa. Myöskään jäähdytteen tasapainotilanlämpötiloista ei ole tarkkaa tietoa, mutta joitakin oletuksia voidaan tehdä samoilla parametreilla tehtyjen Volley 05 -kokeiden perusteella. Mittaustulokset Volley 04 ja 05 -kokeista, jotka on videoitu ja voitu ajaa tasapainotilaan saakka, antoivat simulaatioiden kanssa hyvin samankaltaisia lämpötilojen arvoja. Keskeytettyjen kokeiden ekstrapolointi tasapainotilaan ei onnistunut kovin hyvin. Kokeet jouduttiin keskeyttämään niin paljon ennen termohydraulista tasapainoa, ettei tasapainotilan reunaehtoja voitu ennustaa. Videonauhoituksen puuttuessa ei veden pinnan korkeudesta saatu lisätietoa. Tuloksista voidaan lähinnä esittää arvioita siitä, mitä suuruusluokkaa mittapisteiden lämpötilat tulevat olemaan. Nämä lämpötilat ovat kuitenkin selvästi alle sydänsiepparissa käytettävän valuraudan sulamislämpötilan. Joten simulaatioiden perusteella voidaan sanoa, etteivät jäähdytyskanavien rakenteet sula, mikäli niissä on pienikin jäähdytevirtaus, eikä useampia kuin muutama vierekkäinen kanava ole täysin kuivana.
Resumo:
The domestic hot water cylinder incorporates encapsulated pcm placed in 57 vertical pipes. The use of PCM increases the thermal energy storage capacity of the cylinder and allows the use of low cost electricity during low peak periods. After experimental validation the numerical model developed in the project will be used to optimize the distribution of the pcm inside the water tank.
Resumo:
IIn electric drives, frequency converters are used to generatefor the electric motor the AC voltage with variable frequency and amplitude. When considering the annual sale of drives in values of money and units sold, the use of low-performance drives appears to be in predominant. These drives have tobe very cost effective to manufacture and use, while they are also expected to fulfill the harmonic distortion standards. One of the objectives has also been to extend the lifetime of the frequency converter. In a traditional frequency converter, a relatively large electrolytic DC-link capacitor is used. Electrolytic capacitors are large, heavy and rather expensive components. In many cases, the lifetime of the electrolytic capacitor is the main factor limiting the lifetime of the frequency converter. To overcome the problem, the electrolytic capacitor is replaced with a metallized polypropylene film capacitor (MPPF). The MPPF has improved properties when compared to the electrolytic capacitor. By replacing the electrolytic capacitor with a film capacitor the energy storage of the DC-linkwill be decreased. Thus, the instantaneous power supplied to the motor correlates with the instantaneous power taken from the network. This yields a continuousDC-link current fed by the diode rectifier bridge. As a consequence, the line current harmonics clearly decrease. Because of the decreased energy storage, the DC-link voltage fluctuates. This sets additional conditions to the controllers of the frequency converter to compensate the fluctuation from the supplied motor phase voltages. In this work three-phase and single-phase frequency converters with small DC-link capacitor are analyzed. The evaluation is obtained with simulations and laboratory measurements.
Resumo:
The application of forced unsteady-state reactors in case of selective catalytic reduction of nitrogen oxides (NOx) with ammonia (NH3) is sustained by the fact that favorable temperature and composition distributions which cannot be achieved in any steady-state regime can be obtained by means of unsteady-state operations. In a normal way of operation the low exothermicity of the selective catalytic reduction (SCR) reaction (usually carried out in the range of 280-350°C) is not enough to maintain by itself the chemical reaction. A normal mode of operation usually requires supply of supplementary heat increasing in this way the overall process operation cost. Through forced unsteady-state operation, the main advantage that can be obtained when exothermic reactions take place is the possibility of trapping, beside the ammonia, the moving heat wave inside the catalytic bed. The unsteady state-operation enables the exploitation of the thermal storage capacity of the catalyticbed. The catalytic bed acts as a regenerative heat exchanger allowing auto-thermal behaviour when the adiabatic temperature rise is low. Finding the optimum reactor configuration, employing the most suitable operation model and identifying the reactor behavior are highly important steps in order to configure a proper device for industrial applications. The Reverse Flow Reactor (RFR) - a forced unsteady state reactor - corresponds to the above mentioned characteristics and may be employed as an efficient device for the treatment of dilute pollutant mixtures. As a main disadvantage, beside its advantages, the RFR presents the 'wash out' phenomena. This phenomenon represents emissions of unconverted reactants at every switch of the flow direction. As a consequence our attention was focused on finding an alternative reactor configuration for RFR which is not affected by the incontrollable emissions of unconverted reactants. In this respect the Reactor Network (RN) was investigated. Its configuration consists of several reactors connected in a closed sequence, simulating a moving bed by changing the reactants feeding position. In the RN the flow direction is maintained in the same way ensuring uniformcatalyst exploitation and in the same time the 'wash out' phenomena is annulated. The simulated moving bed (SMB) can operate in transient mode giving practically constant exit concentration and high conversion levels. The main advantage of the reactor network operation is emphasizedby the possibility to obtain auto-thermal behavior with nearly uniformcatalyst utilization. However, the reactor network presents only a small range of switching times which allow to reach and to maintain an ignited state. Even so a proper study of the complex behavior of the RN may give the necessary information to overcome all the difficulties that can appear in the RN operation. The unsteady-state reactors complexity arises from the fact that these reactor types are characterized by short contact times and complex interaction between heat and mass transportphenomena. Such complex interactions can give rise to a remarkable complex dynamic behavior characterized by a set of spatial-temporal patterns, chaotic changes in concentration and traveling waves of heat or chemical reactivity. The main efforts of the current research studies concern the improvement of contact modalities between reactants, the possibility of thermal wave storage inside the reactor and the improvement of the kinetic activity of the catalyst used. Paying attention to the above mentioned aspects is important when higher activity even at low feeding temperatures and low emissions of unconverted reactants are the main operation concerns. Also, the prediction of the reactor pseudo or steady-state performance (regarding the conversion, selectivity and thermal behavior) and the dynamicreactor response during exploitation are important aspects in finding the optimal control strategy for the forced unsteady state catalytic tubular reactors. The design of an adapted reactor requires knowledge about the influence of its operating conditions on the overall process performance and a precise evaluation of the operating parameters rage for which a sustained dynamic behavior is obtained. An apriori estimation of the system parameters result in diminution of the computational efforts. Usually the convergence of unsteady state reactor systems requires integration over hundreds of cycles depending on the initial guess of the parameter values. The investigation of various operation models and thermal transfer strategies give reliable means to obtain recuperative and regenerative devices which are capable to maintain an auto-thermal behavior in case of low exothermic reactions. In the present research work a gradual analysis of the SCR of NOx with ammonia process in forced unsteady-state reactors was realized. The investigation covers the presentationof the general problematic related to the effect of noxious emissions in the environment, the analysis of the suitable catalysts types for the process, the mathematical analysis approach for modeling and finding the system solutions and the experimental investigation of the device found to be more suitable for the present process. In order to gain information about the forced unsteady state reactor design, operation, important system parameters and their values, mathematical description, mathematicalmethod for solving systems of partial differential equations and other specific aspects, in a fast and easy way, and a case based reasoning (CBR) approach has been used. This approach, using the experience of past similarproblems and their adapted solutions, may provide a method for gaining informations and solutions for new problems related to the forced unsteady state reactors technology. As a consequence a CBR system was implemented and a corresponding tool was developed. Further on, grooving up the hypothesis of isothermal operation, the investigation by means of numerical simulation of the feasibility of the SCR of NOx with ammonia in the RFRand in the RN with variable feeding position was realized. The hypothesis of non-isothermal operation was taken into account because in our opinion ifa commercial catalyst is considered, is not possible to modify the chemical activity and its adsorptive capacity to improve the operation butis possible to change the operation regime. In order to identify the most suitable device for the unsteady state reduction of NOx with ammonia, considering the perspective of recuperative and regenerative devices, a comparative analysis of the above mentioned two devices performance was realized. The assumption of isothermal conditions in the beginningof the forced unsteadystate investigation allowed the simplification of the analysis enabling to focus on the impact of the conditions and mode of operation on the dynamic features caused by the trapping of one reactant in the reactor, without considering the impact of thermal effect on overall reactor performance. The non-isothermal system approach has been investigated in order to point out the important influence of the thermal effect on overall reactor performance, studying the possibility of RFR and RN utilization as recuperative and regenerative devices and the possibility of achieving a sustained auto-thermal behavior in case of lowexothermic reaction of SCR of NOx with ammonia and low temperature gasfeeding. Beside the influence of the thermal effect, the influence of the principal operating parameters, as switching time, inlet flow rate and initial catalyst temperature have been stressed. This analysis is important not only because it allows a comparison between the two devices and optimisation of the operation, but also the switching time is the main operating parameter. An appropriate choice of this parameter enables the fulfilment of the process constraints. The level of the conversions achieved, the more uniform temperature profiles, the uniformity ofcatalyst exploitation and the much simpler mode of operation imposed the RN as a much more suitable device for SCR of NOx with ammonia, in usual operation and also in the perspective of control strategy implementation. Theoretical simplified models have also been proposed in order to describe the forced unsteady state reactors performance and to estimate their internal temperature and concentration profiles. The general idea was to extend the study of catalytic reactor dynamics taking into account the perspectives that haven't been analyzed yet. The experimental investigation ofRN revealed a good agreement between the data obtained by model simulation and the ones obtained experimentally.
Resumo:
OBJECTIVE: This study investigated the effectiveness of stereotactic body radiotherapy with helical TomoTherapy (T-SBRT) for treating medically inoperable primary and second-primary early stage non-small-cell lung neoplasm (SPLN) and evaluated whether the movement of organizing pneumonia (OP) within the irradiation field (IF) can be detected via analysis of radiological changes. METHODS: Patients (n = 16) treated for 1 year (2011-12) at our hospital by T-SBRT at a total dose of 60 Gy in five fractions were examined retrospectively. Outcome and toxicity were recorded and were separately described for SPLN. CT scans were reviewed by a single radiologist. RESULTS: Of the 16 patients, 5 (31.3%) had primary lung malignancies, 10 (62.5%) had SPLN, and 1 case (6.3%) had isolated mediastinal metastasis of lung neoplasm. Pathological evidence was obtained for 72.2% of all lesions. The median radiological follow-up was 11 months (10.5 months for SPLN). For all cases, the 6- and 12-month survival rates were 100% and 77.7% (100% and 71.4%, respectively, for SPLN), and the 6- and 12-month locoregional control rates were 100% in all cases. 2 (12.5%) of 16 patients developed grade 3 late transient radiation pneumonitis following steroid therapy and 1 (6.3%) presented asymptomatic infiltrates comparable to OP opacities. CONCLUSION: T-SBRT seems to be safe and effective. ADVANCES IN KNOWLEDGE: Mild OP is likely associated with radiation-induced anomalies in the IF, identification of migrating opacities can help discern relapse of radiation-induced opacities.
Resumo:
Postmortem imaging consists in the non-invasive examination of bodies using medical imaging techniques. However, gas volume quantification and the interpretation of the gas collection results from cadavers remain difficult. We used whole-body postmortem multi-detector computed tomography (MDCT) followed by a full autopsy or external examination to detect the gaseous volumes in bodies. Gases were sampled from cardiac cavities, and the sample compositions were analyzed by headspace gas chromatography-mass spectrometry/thermal conductivity detection (HS-GC-MS/TCD). Three categories were defined according to the presumed origin of the gas: alteration/putrefaction, high-magnitude vital gas embolism (e.g., from scuba diving accident) and gas embolism of lower magnitude (e.g., following a traumatic injury). Cadaveric alteration gas was diagnosed even if only one gas from among hydrogen, hydrogen sulfide or methane was detected. In alteration cases, the carbon dioxide/nitrogen ratio was often >0.2, except in the case of advanced alteration, when methane presence was the best indicator. In the gas embolism cases (vital or not), hydrogen, hydrogen sulfide and methane were absent. Moreover, with high-magnitude vital gas embolisms, carbon dioxide content was >20%, and the carbon dioxide/nitrogen ratio was >0.2. With gas embolisms of lower magnitude (gas presence consecutive to a traumatic injury), carbon dioxide content was <20% and the carbon dioxide/nitrogen ratio was often <0.2. We found that gas analysis provided useful assistance to the postmortem imaging diagnosis of causes of death. Based on the quantifications of gaseous cardiac samples, reliable indicators were determined to document causes of death. MDCT examination of the body must be performed as quickly as possible, as does gas sampling, to avoid generating any artifactual alteration gases. Because of cardiac gas composition analysis, it is possible to distinguish alteration gases and gas embolisms of different magnitudes.
Resumo:
S u b s u r face fluid flow plays a significant role in many geologic processes and is increasingly being studied in the scale of sedimentary basins and geologic time perspective. Many economic resources such as petroleum and mineral deposits are products of basin scale fluid flow operating over large periods of time. Such ancient flow systems can be studied through analysis of diagenetic alterations and fluid inclusions to constrain physical and chemical conditions of fluids and rocks during their paleohy d r og e o l ogic evolution. Basin simulation models are useful to complement the paleohy d r og e o l ogic record preserved in the rocks and to derive conceptual models on hydraulic basin evolution and generation of economic resources. Different types of fluid flow regimes may evo l ve during basin evolution. The most important with respect to flow rates and capacity for transport of solutes and thermal energy is gr avitational fluid flow driven by the topographic configuration of a basin. Such flow systems require the basin to be elevated above sea level. Consolidational fluid flow is the principal fluid migration process in basins below sea level, caused by loading of compressible rocks. Flow rates of such systems are several orders of magnitude below topogr a p hy driven flow. Howeve r, consolidation may create significant fluid ove rpressure. Episodic dewatering of ove rpressured compart m e n t s m ay cause sudden fluid release with elevated flow velocities and may cause a transient local thermal and chemical disequilibrium betwe e n fluid and rock. This paper gives an ove rv i ew on subsurface fluid flow processes at basin scale and presents examples related to the Pe n e d è s basin in the central Catalan continental margin including the offshore Barcelona half-graben and the compressive South-Pyrenean basin.