918 resultados para reverse-phase high-performance liquid chromatography
Resumo:
The carotenoid composition of Brazilian Valencia orange juice was determined by open column chromatography (OCC) and high-performance liquid chromatography. Carotenoid pigments were extracted using acetone and saponified using 10% methanolic potassium hydroxide. Sixteen pigments were isolated by OCC and identified as alpha-carotene, zeta-carotene, beta-carotene, alpha-cryptoxanthin, beta-cryptoxanthin, lutein-5,6-epoxide, violaxanthin, lutein, antheraxanthin, zeaxanthin, luteoxanthin A, luteoxanthin B, mutatoxanthin A, mutatoxanthin B, auroxanthin B and trollichrome B. Thirteen carotenoid pigments were separated using a ternary gradient (acetonitrile-methanol-ethyl acetate) elution on a C-18 reversed-phase column. Among these, violaxanthin, lutein, zeaxanthin, beta-cryptoxanthin, zeta-carotene, alpha-carotene, and beta-carotene were quantified. The total carotenoid content was 12 +/- 6.7 mg/1, and the major carotenoids were lutein (23%), beta-cryptoxanthin (21%), and zeaxanthin (20%). 2005 Elsevier Ltd. All rights reserved.
Resumo:
We evaluated the presence of the melatonin metabolite N-1-acetyl-N-2-formyl-5-methoxykynuramine (AFMK), in cerebrospinal fluid (CSF) of patients with viral meningitis (n = 20) and control samples (n = 8) and correlate AFMK levels with inflammatory markers such as cellularity, protein, tumor necrosis factor (TNF)-alpha, interleukin (IL)-8 and IL-1 beta levels. A portion of the CSF was extracted with dichloromethane (1:5) and analyzed by high-performance liquid chromatography (HPLC) under standardized conditions for AFMK. AFMK was detected in 16 of 20 CSF samples of patients with viral meningitis; the concentration of AFMK was found to be above the quantification limit (50 nmol/L) in six of these samples. AFMK was not detected in any of the eight control samples. The samples were classified into groups according to AFMK levels: undetectable (< 10 nmol/L, group I), detectable but below the quantification limit (< 50 nmol/L, group II), and quantified (> 50 nmol/L, group III). Group II presented the highest levels of proteins and IL-8, whereas group III showed the lowest levels of the inflammatory parameters. This study supports our hypothesis that inflammation favors the formation of AFMK and that this compound has immunomodulatory activity in vivo.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
A high performance liquid chromatography (HPLC) method for extraction and determination of pesticides from raw milk was developed. The method involves direct injection of raw milk samples on a bovine serum albumin-dimethyl-octyl-silica gel (BSA-Si-Cs) column. The mobile phase 0.05 mol.L-1 phosphate buffer pH6.0 in acetonitrile (70:30 v/v) was employed for extraction and separation of bendiocarb, methylparathion, pentachlorophenol, and methomyl pesticides. The method shows good results of recovery in the pesticides studied, higher than 99.6%.
Resumo:
The pharmacokinetics of enrofloxacin (ENRO), a fluoroquinolone antimicrobial agent, was studied in male broiler chickens (Cobb) after single oral administration of 10 mg of ENRO/kg b.w. A high-performance liquid chromatography-photodiode array detector (DAD) (HPLC-DAD) method was developed and validated and used for quantitation of ENRO and its major metabolite ciprofloxacin in plasma. The HPLC analyses were carried out using a cationic-octadecyl mixed column and 0.05 mol/L phosphate buffer (pH 2.5)/acetonitrile as mobile phase. The sample preparation of plasma consisted of the precipitation of proteins followed by solid phase extraction on cationic-octadecyl mixed cartridges. The method was validated considering linear range, linearity, selectivity, sensitivity, limit of detection (LOD), limit of quantitation (LOQ), intra- and inter-day precisions and accuracy. The LOD and LOQ for both fluoroquinolones were 60 and 200 ng/mL for plasma. The plasma concentration vs. time graph was characteristic of a two-compartment open model. The maximal plasma concentration of 1.5 +/- 0.2 mg/mL was achieved at 9 +/- 2 h. The elimination half-life and the mean residence time of ENRO were 1.5 +/- 0.2 and 15.64 h, respectively. The area under the concentration-time curve was calculated as 35 +/- 4 mg(.)h/mL.
Resumo:
Equine antivenom is considered the only treatment for animal-generated envenomations, but it is costly. The study aimed to produce Apis mellifera (Africanized honeybee) and Crotalus durissus terrificus (C.d.t.) antivenoms using nanostructured silica (SBA-15) as adjuvant and cobalt-60 (60Co)-detoxified venoms utilizing young sheep. Natural and 60Co-irradiated venoms were employed in four different hyperimmunization protocols. Thus, 8 groups of 60- to 90-d-old sheep were hyperimmunized, enzyme-linked immunosorbent assay (ELISA) serum titers collected every 14 d were assessed clinically daily, and individual weight were measured, until d 84. Incomplete Freund's (IFA) and nanostructured silica (SBA15) adjuvants were compared. The lethal dose (LD50) for both venoms was determined following intraperitoneal (ip) administration to mice. High-performance liquid chromatography on reversed phase (HPLC-RP) was used also to measure the 60Co irradiation effects on Apis venom. At the end of the study, sheep were killed in a slaughterhouse. Kidneys were histologically analyzed. LD50 was 5.97 mg/kg Apis and 0.07 mg/kg C.d.t. for native compared to 13.44 mg/kg Apis and 0.35 mg/kg C.d.t. for irradiated venoms. HPLC revealed significant differences in chromatographic profiles between native and irradiated Apis venoms. Native venom plus IFA compared with SBA-15 showed significantly higher antibody titers for both venoms. Apis-irradiated venom plus IFA or SBA-15 displayed similar antibody titers but were significantly lower when compared with native venom plus IFA. Weight gain did not differ significantly among all groups. 60Co irradiation decreased toxicity and maintained venom immunogenic capacity, while IFA produced higher antibody titers. SBA-15 was able to act as an adjuvant without producing adverse effects. Hyperimmunization did not affect sheep weight gain, which would considerably reduce the cost of antiserum production, as these sheep were still approved for human consumption even after being subjected to hyperimmunization.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
As hemoglobinopatias são um grupo de afecções genéticas que representam problema de saúde pública em muitos países em que sua incidência é alta, com significativa morbidade. Objetivamos identificar defeitos moleculares que pudessem explicar o perfil laboratorial obtido por eletroforese e HPLC com Hb F elevada, em um grupo de indivíduos adultos sem sinais ou sintomas de anemia. Encontramos cinco diferentes mutações que originam beta talassemia por PCR-ASO: três casos com CD 6 (-A), um CD 39, um IVS 1-5, um -87 todas de origem mediterrânea, e um IVS II-654 de origem asiática. As mutações CD 6 (-A), -87 e IVS II-654 foram descritas pela primeira vez na população brasileira.
Resumo:
Several factors render carotenoid determination inherently difficult. Thus, in spite of advances in analytical instrumentation, discrepancies in quantitative results on carotenoids can be encountered in the international literature. A good part of the errors comes from the pre-chromatographic steps such as sampling scheme that does not yield samples representative of the food lots under investigation; sample preparation which does not maintain representativity and guarantee homogeneity of the analytical sample; incomplete extraction; physical losses of carotenoids during the various steps, especially during partition or washing and by adsorption to glass walls of containers; isomerization and oxidation of carotenoids during analysis. on the otherhand, although currently considered the method of choice for carotenoids, high performance liquid chromatography (HPLC) is subject to various sources of errors, such as: incompatibility of the injection solvent and the mobile phase, resulting in distorted or split peaks; erroneous identification; unavailability, impurity and instability of carotenoid standards; quantification of highly overlapping peaks; low recovery from the HPLC column; errors in the preparation of standard solutions and in the calibration procedure; calculation errors. Illustrations of the possible errors in the quantification of carotenoids by HPLC are presented.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)