942 resultados para product data management system


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The need to effectively manage the documentation covering the entire production process, from the concept phase right through to market realise, constitutes a key issue in the creation of a successful and highly competitive product. For almost forty years the most commonly used strategies to achieve this have followed Product Lifecycle Management (PLM) guidelines. Translated into information management systems at the end of the '90s, this methodology is now widely used by companies operating all over the world in many different sectors. PLM systems and editor programs are the two principal types of software applications used by companies for their process aotomation. Editor programs allow to store in documents the information related to the production chain, while the PLM system stores and shares this information so that it can be used within the company and made it available to partners. Different software tools, which capture and store documents and information automatically in the PLM system, have been developed in recent years. One of them is the ''DirectPLM'' application, which has been developed by the Italian company ''Focus PLM''. It is designed to ensure interoperability between many editors and the Aras Innovator PLM system. In this dissertation we present ''DirectPLM2'', a new version of the previous software application DirectPLM. It has been designed and developed as prototype during the internship by Focus PLM. Its new implementation separates the abstract logic of business from the real commands implementation, previously strongly dependent on Aras Innovator. Thanks to its new design, Focus PLM can easily develop different versions of DirectPLM2, each one devised for a specific PLM system. In fact, the company can focus the development effort only on a specific set of software components which provides specialized functions interacting with that particular PLM system. This allows shorter Time-To-Market and gives the company a significant competitive advantage.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PhEDEx, the CMS transfer management system, during the first LHC Run has moved about 150 PB and currently it is moving about 2.5 PB of data per week over the Worldwide LHC Computing Grid (WLGC). It was designed to complete each transfer required by users at the expense of the waiting time necessary for its completion. For this reason, after several years of operations, data regarding transfer latencies has been collected and stored into log files containing useful analyzable informations. Then, starting from the analysis of several typical CMS transfer workflows, a categorization of such latencies has been made with a focus on the different factors that contribute to the transfer completion time. The analysis presented in this thesis will provide the necessary information for equipping PhEDEx in the future with a set of new tools in order to proactively identify and fix any latency issues. PhEDEx, il sistema di gestione dei trasferimenti di CMS, durante il primo Run di LHC ha trasferito all’incirca 150 PB ed attualmente trasferisce circa 2.5 PB di dati alla settimana attraverso la Worldwide LHC Computing Grid (WLCG). Questo sistema è stato progettato per completare ogni trasferimento richiesto dall’utente a spese del tempo necessario per il suo completamento. Dopo svariati anni di operazioni con tale strumento, sono stati raccolti dati relativi alle latenze di trasferimento ed immagazzinati in log files contenenti informazioni utili per l’analisi. A questo punto, partendo dall’analisi di una ampia mole di trasferimenti in CMS, è stata effettuata una suddivisione di queste latenze ponendo particolare attenzione nei confronti dei fattori che contribuiscono al tempo di completamento del trasferimento. L’analisi presentata in questa tesi permetterà di equipaggiare PhEDEx con un insieme di utili strumenti in modo tale da identificare proattivamente queste latenze e adottare le opportune tattiche per minimizzare l’impatto sugli utenti finali.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper is focused on the integration of state-of-the-art technologies in the fields of telecommunications, simulation algorithms, and data mining in order to develop a Type 1 diabetes patient's semi to fully-automated monitoring and management system. The main components of the system are a glucose measurement device, an insulin delivery system (insulin injection or insulin pumps), a mobile phone for the GPRS network, and a PDA or laptop for the Internet. In the medical environment, appropriate infrastructure for storage, analysis and visualizing of patients' data has been implemented to facilitate treatment design by health care experts.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper the software architecture of a framework which simplifies the development of applications in the area of Virtual and Augmented Reality is presented. It is based on VRML/X3D to enable rendering of audio-visual information. We extended our VRML rendering system by a device management system that is based on the concept of a data-flow graph. The aim of the system is to create Mixed Reality (MR) applications simply by plugging together small prefabricated software components, instead of compiling monolithic C++ applications. The flexibility and the advantages of the presented framework are explained on the basis of an exemplary implementation of a classic Augmented Realityapplication and its extension to a collaborative remote expert scenario.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper introduces an area- and power-efficient approach for compressive recording of cortical signals used in an implantable system prior to transmission. Recent research on compressive sensing has shown promising results for sub-Nyquist sampling of sparse biological signals. Still, any large-scale implementation of this technique faces critical issues caused by the increased hardware intensity. The cost of implementing compressive sensing in a multichannel system in terms of area usage can be significantly higher than a conventional data acquisition system without compression. To tackle this issue, a new multichannel compressive sensing scheme which exploits the spatial sparsity of the signals recorded from the electrodes of the sensor array is proposed. The analysis shows that using this method, the power efficiency is preserved to a great extent while the area overhead is significantly reduced resulting in an improved power-area product. The proposed circuit architecture is implemented in a UMC 0.18 [Formula: see text]m CMOS technology. Extensive performance analysis and design optimization has been done resulting in a low-noise, compact and power-efficient implementation. The results of simulations and subsequent reconstructions show the possibility of recovering fourfold compressed intracranial EEG signals with an SNR as high as 21.8 dB, while consuming 10.5 [Formula: see text]W of power within an effective area of 250 [Formula: see text]m × 250 [Formula: see text]m per channel.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Center for Orbit Determination in Europe (CODE) is contributing as a global Analysis center to the International GNSS Service (IGS) since many years. The processing of GPS and GLONASS data is well established in CODE’s ultra-rapid, rapid, and final product lines. With the introduction of new signals for the established and new GNSS, new challenges and opportunities are arising for the GNSS data management and processing. The IGS started the Multi-GNSS-EXperiment (MGEX) in 2012 in order to gain first experience with the new data formats and to develop new strategies for making optimal use of these additional measurements. CODE has started to contribute to IGS MGEX with a consistent, rigorously combined triple-system orbit solution (GPS, GLONASS, and Galileo). SLR residuals for the computed Galileo satellite orbits are of the order of 10 cm. Furthermore CODE established a GPS and Galileo clock solution. A quality assessment shows that these experimental orbit and clock products allow even a Galileo-only precise point positioning (PPP) with accuracies on the decimeter- (static PPP) to meter-level (kinematic PPP) for selected stations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Problems due to the lack of data standardization and data management have lead to work inefficiencies for the staff working with the vision data for the Lifetime Surveillance of Astronaut Health. Data has been collected over 50 years in a variety of manners and then entered into a software. The lack of communication between the electronic health record (EHR) form designer, epidemiologists, and optometrists has led to some level to confusion on the capability of the EHR system and how its forms can be designed to fit all the needs of the relevant parties. EHR form customizations or form redesigns were found to be critical for using NASA's EHR system in the most beneficial way for its patients, optometrists, and epidemiologists. In order to implement a protocol, data being collected was examined to find the differences in data collection methods. Changes were implemented through the establishment of a process improvement team (PIT). Based on the findings of the PIT, suggestions have been made to improve the current EHR system. If the suggestions are implemented correctly, this will not only improve efficiency of the staff at NASA and its contractors, but set guidelines for changes in other forms such as the vision exam forms. Because NASA is at the forefront of such research and health surveillance the impact of this management change could have a drastic improvement on the collection of and adaptability of the EHR. Accurate data collection from this 50+ year study is ongoing and is going to help current and future generations understand the implications of space flight on human health. It is imperative that the vast amount of information is documented correctly.^