933 resultados para passive filter
Resumo:
Analog filters and direct digital filters are implemented using digital signal processing techniques. Specifically, Butterworth, Elliptic, and Chebyshev filters are implemented using the Motorola 56001 Digital Signal Processor by the integration of three software packages: MATLAB, C++, and Motorola's Application Development System. The integrated environment allows the novice user to design a filter automatically by specifying the filter order and critical frequencies, while permitting more experienced designers to take advantage of MATLAB's advanced design capabilities. This project bridges the gap between the theoretical results produced by MATLAB and the practicalities of implementing digital filters using the Motorola 56001 Digital Signal Processor. While these results are specific to the Motorola 56001 they may be extended to other digital signal processors. MATLAB handles the filter calculations, a C++ routine handles the conversion to assembly code, and the Motorola software compiles and transmits the code to the processor
Resumo:
Liquid-liquid extraction (LLE) is a method used to separate compounds based on their relative activity in two immiscible phases. By significantly reducing the scale of liquid-liquid extraction to the micro- and milli-fluidic levels, this separation process can bemade suitable for low volume, high value materials.
Resumo:
Based on the exponential aging of the population and the increasing life expectancy in industrialized western countries, prostate cancer (PCa) in elderly men is becoming a disease of increasing significance. Consensus exists that men over the age of 75 years should not be screened for PCa; however, higher age as a single parameter should not exclude men from being diagnosed with prostate cancer and treated accordingly. It is well-known that overdiagnosis and overtreatment are frequent in this age group. Competing mortality risks of men older than 75 years may supersede the risk of dying from PCa several fold. Both the treating physician and the patient himself should therefore balance the possible risks and benefits of diagnosing and treating prostate cancer concerning the impact on quality of life. This is of special importance when taking into account that the complication rates of curative treatment modalities are higher in older patients than in younger men and that hormonal treatment might have negative effects especially in older men.Age, existing comorbidities, cognitive and physical status in combination with specific tumor parameters are useful tools for an individualized treatment.Therapy should be considered for healthy, active men aged 75 years or older who present with high-risk PCa and/or with a PSA doubling time <12 months. Elderly men who are unfit or have low to intermediate risk PCa will most likely not benefit from treatment.
Resumo:
This field study examined the vitellogenin (VTG) biomarker response under conditions of low and fluctuating activities of environmental estrogenicity. The present study was performed on immature brown trout (Salmo trutta) exposed to the small river Luetzelmurg, which is located in the prealpine Swiss midland region and receives effluents from a single sewage treatment plant (STP). To understand better factors influencing the relationship between estrogenic exposure and VTG induction, we compared VTG levels in caged (stationary) and feral (free-ranging) fish, VTG levels in fish from up- and downstream of the STP, and two different methods for quantifying VTG (enzyme-linked immunosorbent assay vs real-time reverse transcription-polymerase chain reaction), and we used passive samplers (polar organic chemical integrative sampler [POCIS]) to integrate the variable, bioaccumulative estrogenic load in the river water over time. The POCIS from the downstream site contained approximately 20-fold higher levels of bioassay-derived estrogen equivalents than the POCIS from the upstream site. In feral fish, this site difference in estrogenic exposure was reflected in VTG protein levels but not in VTG mRNA. In contrast, in caged fish, the site difference was evident only for VTG mRNA but not for VTG protein. Thus, the outcome of VTG biomarker measurements varied with the analytical detection method (protein vs mRNA) and with the exposure modus (caged vs feral). Our findings suggest that for environmental situations with low and variable estrogenic contamination, a multiple-assessment approach may be necessary for the assessment of estrogenic exposure in fish.
Resumo:
Thrombosis of the inferior vena cava is a life-threatening complication in cancer patients leading to pulmonary embolism. These patients can also be affected by superior vena cava syndrome causing dyspnea followed by trunk or extremity swelling. We report the case of a 61-year-old female suffering from an extended colorectal tumor who became affected by both of the mentioned complications. Due to thrombus formation within the right vena jugularis interna, thrombosis of the inferior vena cava, and superior vena cava syndrome, a combined interventional procedure via a left jugular access with stenting of the superior vena cava and filter placement into the inferior vena cava was performed As a consequence, relief of the patient's symptoms, prevention of pulmonary embolism, and paving of the way for further venous chemotherapy were achieved.
Resumo:
PURPOSES: To evaluate the safety of inferior vena cava (IVC) filter retrieval in therapeutically anticoagulated patients in comparison to prophylactically or not therapeutically anticoagulated patients with respect to retrieval-related hemorrhagic complications. MATERIALS AND METHODS: This was a retrospective study of 115 consecutive attempted IVC filter retrievals in 110 patients. Filter retrievals were stratified as performed in patients who were therapeutically anticoagulated (group 1), prophylactically anticoagulated (group 2), or not therapeutically anticoagulated (group 3). The collected data included anticoagulant and antiplatelet medications (type, form and duration of administration, dosage) at the time of retrieval. Phone interviews and chart review was performed for the international normalized ratio (INR), activated partial thromboplastin time, platelet count, infusion of blood products, and retrieval-related hemorrhagic complications. RESULTS: Group 1 included 65 attempted filter retrievals in 61 therapeutically anticoagulated patients by measured INR or dosing when receiving low-molecular-weight heparin (LMWH). Four retrievals were not successful. In patients receiving oral anticoagulation, the median INR was 2.35 (range, 2 to 8). Group 2 comprised 23 successful filter retrievals in 22 patients receiving a prophylactic dose of LMWH. Group 3 included 27 attempted filter retrievals in 27 patients not receiving therapeutic anticoagulation. Six retrievals were not successful. Five patients were receiving oral anticoagulation with a subtherapeutic INR (median, 1.49; range, 1.16 to 1.69). No anticoagulation medication was administered in 22 patients. In none of the groups were hemorrhagic complications related to the retrieval procedures identified. CONCLUSIONS: These results suggest that retrieval of vena cava filters in anticoagulated patients is safe. Interruption or reversal of anticoagulation for the retrieval of vena cava filters is not indicated.
Resumo:
PURPOSE: To investigate the impact of filter design on blood flow impairment in the internal carotid artery (ICA) among patients undergoing carotid artery stenting (CAS) using filter-type emboli protection devices (EPD). METHODS: Between July 2003 and March 2007, 115 filter-protected CAS procedures were performed at an academic institution in 107 consecutive patients (78 men; mean age 68 years, range 38-87). The Angioguard, FilterWire EZ, and Spider filters were used in 68 (59%), 32 (28%), and 15 (13%) of cases, respectively. Patient characteristics, procedural and angiographic data, and outcomes were prospectively entered into an electronic database and reviewed retrospectively along with all angiograms. RESULTS: Flow impairment while the filter was in place was observed in 25 (22%) cases. The presumptive reason of flow impairment was filter obstruction in 21 (18%) instances and flow-limiting spasm at the level of the filter in 4 (4%). In all cases, flow was restored after retrieval of the filter. Flow obstruction in the ICA occurred more frequently with Angioguard (22/68; 32.3%) than with FilterWire EZ (2/32; 6.2%) or Spider (1/15; 6.7%; p = 0.004). No flow occurred in 13 (19%) procedures, all of them protected with Angioguard; no patient treated with other devices experienced this event (p = 0.007). Two (8.0%) strokes occurred in procedures associated with flow impairment, while 1 (1.1%) event was observed in the presence of preserved flow throughout the intervention (p = 0.11). CONCLUSION: Flow impairment in the ICA during filter-based CAS is common and related to the type of filter used.