998 resultados para pair comparison


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The ventilation efficiency concept is an attempt to quantify a parameter that can easily distinguish the different options for air diffusion in the building spaces. Thirteen strategies of air diffusion were measured in a test chamber through the application of the tracer gas method, with the objective to validate the calculation by Computational fluid dynamics (CFD). Were compared the Air Change Efficiency (ACE) and the Contaminant Removal Effectiveness (CRE), the two indicators most internationally accepted. The main results from this work shows that the values of the numerical simulations are in good agreement with experimental measurements and also, that the solutions to be adopted for maximizing the ventilation efficiency should be the schemes that operate with low speeds of supply air and small differences between supply air temperature and the room temperature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose – Our paper aims at analyzing how different European countries cope with the European Energy Policy, which proposes a set of measures (free energy market, smart meters, energy certificates) to improve energy utilization and management in Europe. Design/methodology/approach – The paper first reports the general vision, regulations and goals set up by Europe to implement the European Energy Policy. Later on, it performs an analysis of how some European countries are coping with the goals, with financial, legal, economical and regulatory measures. Finally, the paper draws a comparison between the countries to present a view on how Europe is responding to the emerging energy emergency of the modern world. Findings – Our analysis on different use cases (countries) showed that European countries are converging to a common energy policy, even though some countries appear to be later than others In particular, Southern European countries were slowed down by the world financial and economical crisis. Still, it appears that contingency plans were put into action, and Europe as a whole is proceeding steadily towards the common vision. Research limitations/implications – European countries are applying yet more cuts to financing green technologies, and it is not possible to predict clearly how each country will evolve its support to the European energy policy. Practical implications – Different countries applied the concepts and measures in different ways. The implementation of the European energy policy has to cope with the resulting plethora of regulations, and a company proposing enhancement regarding energy management still has to possess robust knowledge of the single country, before being able to export experience and know-how between European countries. Originality/Value – Even though a few surveys on energy measures in Europe are already part of the state-of-the-art, organic analysis diagonal to the different topics of the European Energy Policy is missing. Moreover, this paper highlights how European countries are converging on a common view, and provides some details on the differences between the countries, thus facilitating parties interesting into cross-country export of experience and technology for energy management.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do grau de Mestre em Conservação e Restauro,Área de especialização Cerâmica e Vidro

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Let and be matrices over an algebraically closed field. Let be elements of such that and . We give necessary and sufficient condition for the existence of matrices and similar to and, respectively, such that has eigenvalues.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study, we sought to assess the applicability of GC–MS/MS for the identification and quantification of 36 pesticides in strawberry from integrated pest management (IPM) and organic farming (OF). Citrate versions of QuEChERS (quick, easy, cheap, effective, rugged and safe) using dispersive solid-phase extraction (d-SPE) and disposable pipette extraction (DPX) for cleanup were compared for pesticide extraction. For cleanup, a combination of MgSO4, primary secondary amine and C18 was used for both the versions. Significant differences were observed in recovery results between the two sample preparation versions (DPX and d-SPE). Overall, 86% of the pesticides achieved recoveries (three spiking levels 10, 50 and 200 µg/kg) in the range of 70–120%, with <13% RSD. The matrix effects were also evaluated in both the versions and in strawberries from different crop types. Although not evidencing significant differences between the two methodologies were observed, however, the DPX cleanup proved to be a faster technique and easy to execute. The results indicate that QuEChERS with d-SPE and DPX and GC–MS/MS analysis achieved reliable quantification and identification of 36 pesticide residues in strawberries from OF and IPM.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A dot-enzyme-linked immunosorbent assay (Dot-ELISA) for pneumococcal antigen detection was standardized in view of the need for a rapid and accurate immunodiagnosis of acute pneumococcal pneumonia. A total of 442 pleural fluid effusion samples (PFES) from children with clinical and laboratory diagnoses of acute bacterial pneumonia, plus 38 control PFES from tuberculosis patients and 20 negative control serum samples from healthy children were evaluated by Dot-ELISA. The samples were previously treated with 0.1 M EDTA pH 7.5 at 90°C for 10 min and dotted on nitrocellulose membrane. Pneumococcal omniserum diluted at 1:200 was employed in this assay for antigen detection. When compared with standard bacterial culture, counterimmunoelectrophoresis and latex agglutination techniques, the Dot-ELISA results showed relative indices of 0.940 to sensitivity, 0.830 to specificity and 0.760 to agreement. Pneumococcal omniserum proved to be an optimal polyvalent antiserum for the detection of pneumococcal antigen by Dot-ELISA. Dot-ELISA proved to be a practical alternative technique for the diagnosis of pneumococcal pneumonia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

No panorama socioeconómico atual, a contenção de despesas e o corte no financiamento de serviços secundários consumidores de recursos conduzem à reformulação de processos e métodos das instituições públicas, que procuram manter a qualidade de vida dos seus cidadãos através de programas que se mostrem mais eficientes e económicos. O crescimento sustentado das tecnologias móveis, em conjunção com o aparecimento de novos paradigmas de interação pessoa-máquina com recurso a sensores e sistemas conscientes do contexto, criaram oportunidades de negócio na área do desenvolvimento de aplicações com vertente cívica para indivíduos e empresas, sensibilizando-os para a disponibilização de serviços orientados ao cidadão. Estas oportunidades de negócio incitaram a equipa do projeto a desenvolver uma plataforma de notificação de problemas urbanos baseada no seu sistema de informação geográfico para entidades municipais. O objetivo principal desta investigação foca a idealização, conceção e implementação de uma solução completa de notificação de problemas urbanos de caráter não urgente, distinta da concorrência pela facilidade com que os cidadãos são capazes de reportar situações que condicionam o seu dia-a-dia. Para alcançar esta distinção da restante oferta, foram realizados diversos estudos para determinar características inovadoras a implementar, assim como todas as funcionalidades base expectáveis neste tipo de sistemas. Esses estudos determinaram a implementação de técnicas de demarcação manual das zonas problemáticas e reconhecimento automático do tipo de problema reportado nas imagens, ambas desenvolvidas no âmbito deste projeto. Para a correta implementação dos módulos de demarcação e reconhecimento de imagem, foram feitos levantamentos do estado da arte destas áreas, fundamentando a escolha de métodos e tecnologias a integrar no projeto. Neste contexto, serão apresentadas em detalhe as várias fases que constituíram o processo de desenvolvimento da plataforma, desde a fase de estudo e comparação de ferramentas, metodologias, e técnicas para cada um dos conceitos abordados, passando pela proposta de um modelo de resolução, até à descrição pormenorizada dos algoritmos implementados. Por último, é realizada uma avaliação de desempenho ao par algoritmo/classificador desenvolvido, através da definição de métricas que estimam o sucesso ou insucesso do classificador de objetos. A avaliação é feita com base num conjunto de imagens de teste, recolhidas manualmente em plataformas públicas de notificação de problemas, confrontando os resultados obtidos pelo algoritmo com os resultados esperados.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A candidin, which is a suspension of killed yeast cells, is commonly used for intradermal tests of delayed hypersensitivity, to evaluate the immunological cellular competence of the patient, when the test is applied along with other similar tests. When working with a cellular antigen, the histopathology of positive skin tests reveals a cellular infiltrate which not only presents a characteristic hypersensitivity reaction but also a neutrophilic abscess in the central part. This research presents the results of a comparison between the yeast cell suspension and the polysaccharide antigens, both obtained from the same strains of Candida albicans. The results obtained by skin tests in one hundred individuals were 61.0% with the polysaccharide antigen and 69.0% with the yeast cell suspension antigen. Concordant results concerning the two antigens were observed in 82.0% of the individuals. The discussion section presents an assumption to explain the differences of positivity obtained with the two antigens. We conclude that the polysaccharide antigen can be utilized in the intradermal test of delayed hypersensitivity to Candida albicans.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertation submitted in partial fulfilment of the requirements for the Degree of Master of Science in Geospatial Technologies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work was planned by taking into account all the knowledge accumulated from the immunological study of paracoccidioidomycosis. It aimed at comparing a polysaccharide antigen from Histoplasma capsulatum to a classic histoplasmin with the help of intradermal tests of delayed type of hypersensitivity. Tests were applied to 115 individuals in Santo Amaro, a town in the state of São Paulo. Positive results using classic histoplasmin were obtained in 46.0% cases whereas positive results using the polysaccharide antigen at its hightest concentration were obtained in 51.30% cases. The major conclusion in this investigation is that it is possible to use the polysaccharide antigen as histoplasmin instead of the filtrate antigen

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper deals with the analysis of 10 batches of L.major-like and L.(V.) braziliensis antigens added or not of a proteases inhibitor evaluated by means of an IgG-ELISA on three consecutive days using positive standard sera from patients with diagnosis of American Leishmaniasis previously tested for the presence of IgG antibodies by means of ELISA. The statistical analysis showed that for L. (V.) braziliensis the PMSF-containing antigen did not show any difference among batches or days of testing; the L.(V.) braziliensis antigen without PMSF showed statistical significance for differences among batches and a two-way ANOVA showed significant differences between antigens. L.major-like antigen prepared with or without PMSF showed differences among batches; all 3 days of testing displayed differences for the PMSF antigen but only for days 1 and 2 for the antigen without inhibitor. A two-way ANOVA showed differences among batches of the antigens but not for antigens with and without the protein inhibitor. According to the statistical analysis the L.major-like antigen added or not of PMSF has shown that it is the choice antigen for mucocutaneous leishmaniasis serology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The most practicable assay for measurement of measles IgG (mIgG) in large numbers of sera is an enzyme immunoassay (EIA). To assess how EIA results would agree with those by the gold standard method of plaque reduction neutralization (PRN) we compared the results from the two methods in 43 pairs of maternal and umbilical cord sera, and sera from the corresponding infants when aged 11 - 14 months. In maternal-cord sera, the differences between mean antibody levels by EIA or PRN were not statistically significant, though in individual sera, differences could be large. However, agreement was less good for infants sera, in which levels of mIgG were very low. The conclusions of a study of transplacental transport of mIgG would not be affected by the use of either technique. When studying waning immunity in infants, PRN should be the method of choice, while results from studies using EIA should be interpreted with caution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A pair matched case/control study was conducted from January 1991 to 30 June 1992 in order to define clinical and laboratory findings associated with DMAC infection in AIDS patients. Since DMAC infection is usually associated with advanced immunodeficiency, and therefore also with other opportunistic illnesses, in addition to the number of CD4+ lymphocytes, cases and controls were matched using the following criteria: date of AIDS diagnosis and antiretroviral therapy, number and severity of associated opportunistic infections and, whenever possible, type of Pneumocystis carinii prophylaxis, age and gender, in this order of relevance. Cases (defined as patients presenting at least one positive culture for MAC at a normally sterile site) and controls presented CD4+ lymphocyte counts below 50 cel/mm3. A significantly higher prevalence of general, digestive and respiratory signs, increased LDH levels, low hemoglobin levels and CD4+ cell counts were recorded for cases when compared to controls. Increases in gGT and alkaline phosphatase levels seen in cases were also recorded for controls. In conclusion, the strategy we used for selecting controls allowed us to detect laboratory findings associated to DMAC infection not found in other advanced immunossupressed AIDS patients without DMAC.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Screening blood donations for anti-HCV antibodies and alanine aminotransferase (ALT) serum levels generally prevents the transmission of hepatitis C virus (HCV) by transfusion. The aim of the present study was to evaluate the efficiency of the enzyme immunoassay (EIA) screening policy in identifying potentially infectious blood donors capable to transmit hepatitis C through blood transfusion. We have used a reverse transcriptase (RT)-nested polymerase chain reaction (PCR) to investigate the presence of HCV-RNA in blood donors. The prevalence of HCV-RNA positive individuals was compared with the recombinant immunoblot assay (RIBA-2) results in order to assess the usefulness of both tests as confirmatory assays. Both tests results were also compared with the EIA-2 OD/C ratio (optical densities of the samples divided by the cut off value). ALT results were expressed as the ALT quotient (qALT), calculated dividing the ALT value of the samples by the maximum normal value (53UI/l) for the method. Donors (n=178) were divided into five groups according to their EIA anti-HCV status and qALT: group A (EIA > or = 3, ALT<1), group B (EIA > or = 3, ALT>1), group C (1<=EIA<3, ALT<1), group D (1<=EIA<3, ALT>1) and group E (EIA<=0.7). HCV sequences were detected by RT-nested PCR, using primers for the most conserved region of viral genome. RIBA-2 was applied to the same samples. In group A (n=6), all samples were positive by RT-nested PCR and RIBA-2. Among 124 samples in group B, 120 (96.8%) were RIBA-2 positive and 4 (3.2%) were RIBA-2 indeterminate but were seropositive for antigen c22.3. In group B, 109 (87.9%) of the RIBA-2 positive samples were also RT-nested PCR positive, as well as were all RIBA-2 indeterminate samples. In group C, all samples (n=9) were RT-nested PCR negative: 4 (44.4%) were also RIBA-2 negative, 4 (44.4%) were RIBA-2 positive and 1 (11.1%) was RIBA-2 indeterminate. HCV-RNA was detected by RT-nested PCR in 3 (37.5%) out of 8 samples in group D. Only one of them was also RIBA-2 positive, all the others were RIBA-2 indeterminate. All of the group E samples (controls) were RT- nested PCR and RIBA-2 negative. Our study suggests a strong relation between anti-HCV EIA-2 ratio > or = 3 and detectable HCV-RNA by RT-nested PCR. We have also noted that blood donors with RIBA-2 indeterminate presented a high degree of detectable HCV-RNA using RT-nested PCR (75%), especially when the c22.3 band was detected.