957 resultados para non-destructive test


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Indicators microorganisms can be used as a method for evaluating the sanitary quality of food products, indicating the suitability of conditions for obtaining, processing and storage of food. This study sought to evaluate surface contamination of cattle carcasses that come from a slaughter plant under Federal Inspection in western Parana by mesophilic bacteria (AM), Enterobacteriaceae (EB), coliform at 35 degrees C (TC) and E. coli (EC). Surface samples were collected from 25 carcasses, each at 4 different points of slaughter, for non-destructive method. The samples were diluted in decimal scale and incubated in Petrifilm (R) plates. Were found averages of 1.46; 0.3; 0.23 and 0.21 log CFU / cm (2) for AM, EB, CT and EC, respectively. The values to be found were well below those recommended by the decision 471/2001 of the European Union and several other authors surveyed, indicating the effectiveness of the hygienic process industry.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

O desenvolvimento de técnicas não invasivas e não destrutivas para a avaliação da composição e qualidade de carcaça em animais tem mobilizado consideráveis recursos em pesquisa. A ultra-sonografia aparece neste contexto como uma técnica viável, confiável e de custo aceitável para esta função. No presente trabalho foi avaliada a técnica de ultra-sonografia em tempo real como ferramenta para predição da área de olho-de-lombo (AOL) e espessura da camada de gordura subcutânea (ECG) a partir de imagens tomadas em animais vivos, quando comparadas com as medições na carcaça. Foram utilizados 115 bovinos jovens (30, ½ Angus x Nellore; 30, ½ Canchim x Nellore; 30, ½ Simental x Nellore, e 25 Nellores), com peso inicial médio de 329 kg e de dois tamanhos à maturidade (pequeno e grande), no sistema de produção do novilho superprecoce. As medidas de ultra-sonografia foram realizadas a cada 28 dias totalizando quatro medições até o final do confinamento. A precisão da predição aumentou em função da proximidade da data do abate, sendo máxima na quarta medida (R²= 0,68 para AOL e 0,82 para ECG). Houve efeito de grupo genético e de medida ultra-sonográfica para ECG. O tamanho corporal não teve efeito sobre nenhuma das características estudadas.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objective: The aim of this study was to investigate the effectiveness of two alternatives methods for the disinfection of oral cleaning devices. Methods: One type of toothbrush and two types of tongue scrapers (steel and plastic) were tested in this study. Sixteen specimens of each group were cut with standardized dimensions, contaminated separately with Candida albicans, Streptococcus mutans and Staphylococcus aureus and incubated for 24 h. After this, oral cleaning devices were washed in saline solution to remove non-adhered cells and divided into two groups (n = 8), one irradiated in microwave and other immersed in 3.78% sodium perborate solution, and evaluated for microbial recovery. The values of cfu of each group of microorganism after disinfection were compared by Kruskal-Wallis and Dunn non-parametric test, considering 95% of confidence. Results: The toothbrush harboured a significant larger number of viable organisms than the tongue scrapers. The steel tongue scraper was less susceptible to adhesion of the three oral microorganisms. The time required to inactivate all contaminating microorganisms using microwave oven was 1 min and, for the immersion in 3.78% sodium perborate solution, was 2 and 3 h, respectively, for C. albicans and S. mutans/S. aureus. Conclusion: Microwave irradiation proved to be an effective alternative method to the disinfection of tongue cleaners and toothbrushes.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

O Limiar Anaeróbio (Lan) pode ser determinado por protocolos que utilizam concentrações fixas de lactato sanguíneo como o OBLA (Onset of Blood Lactate Accumulation) e os que utilizam procedimentos mais individualizados, como o Lactato Mínimo (Lacmin). Independente do método, a mensuração da capacidade aeróbia através do Lan nesses casos exige a utilização de equipamentos sofisticados, além do elevado custo por atleta, o que torna sua aplicação limitada. Como alternativa, um dos testes não invasivos mais empregados no meio esportivo é o de 12 minutos proposto por Cooper. O objetivo principal do presente estudo foi comparar a intensidade de exercício obtida pelo teste de 12min com as intensidades correspondentes ao Lan obtido pelo protocolo adaptado ao de Tegtbur et al. (1993) (Lac minat) e pelo OBLA em futebolistas profissionais. Para tanto participaram 16 atletas pertencentes a uma equipe profissional filiada à série A3 do futebol paulista. Cada atleta foi avaliado nos três protocolos, com intervalo mínimo de 48 e máximo de 72 horas. Os resultados mostraram diferença (p < 0,05) entre as velocidades (km.h-1) obtidas pelo teste de Cooper (15,09 ± 0,94) e OBLA (14,28 ± 1,02); entretanto, esses testes apresentaram correlação significativa. Cooper e OBLA não apresentaram correlação com o Lac minat, mas as velocidades foram similares com esse protocolo. Dessa maneira, a partir da análise de regressão entre os valores de Cooper e OBLA foi possível determinar uma equação de correção que permita, através do teste de Cooper, a obtenção da intensidade correspondente ao Lan determinado pelo OBLA em futebolistas profissionais.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A análise de crescimento de plantas pode ser considerada um bom indicativo para a avaliação das bases fisiológicas de produção e da influência exercida por variáveis ambientais, genéticas e agronômicas. Avaliou-se o crescimento da figueira 'Roxo de Valinhos', submetida a irrigação e cobertura morta (bagacilho de cana-de-açúcar triturado), em Botucatu (SP). O experimento utilizou blocos casualizados, em esquema fatorial 2x2 (cobertura morta x irrigação), com 4 repetições, sendo cada repetição constituída por 3 plantas, com caracterização dos seguintes tratamentos: T1 - sem irrigação e sem cobertura morta; T2 - sem irrigação e com cobertura morta; T3 - com irrigação e sem cobertura morta; T4 - com irrigação e cobertura morta. Foram realizadas análises destrutivas e não destrutivas, aos 7, 55, 76, 97, 114, 135, 156, 176, 198, 219, 240, 254 e 275 dias após o transplantio, com base nos seguintes parâmetros: diâmetro do ramo e do caule, comprimento do ramo, número de folhas, número de entrenós e número de frutos. Foram particionados os diferentes órgãos da planta, para obtenção da massa seca e fresca das partições isoladas. As medições da área foliar (cm²) foram realizadas com aparelho integrador fotoelétrico. O manejo da irrigação foi realizado com o auxílio da técnica de tensiometria, mantendo o potencial matricial do solo próximo a -30 kPa. O uso de cobertura morta e irrigação favoreceu o desenvolvimento das plantas (diâmetro do caule de 36,60 mm e comprimento do ramo de 1,28 m), e as taxas de crescimento, crescimento relativo e assimilatória líquida da cultura foram de 7 g m-2 dia-1, 0,015 g g-1 dia-1 e 17 g m-2 dia-1, respectivamente. As taxas indicaram que a cobertura morta ofereceu condições hídricas satisfatórias ao rápido estabelecimento das mudas.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

As imagens obtidas pelos raios X vêm sendo utilizadas na análise da qualidade de sementes desde os anos 50 e, atualmente, vêm se destacando por ser um método rápido, de boa precisão e não destrutivo. Deste modo, o presente trabalho foi realizado com o objetivo de avaliar as características morfológicas dos embriões de sementes de Tecoma stans L. Juss. ex Kunth pertencentes a diferentes classes de massa através da análise de imagens obtidas pelo uso dos raios X, correlacionando-as com a germinação e morfologia das plântulas. Foram utilizadas sete classes de massa com trinta sementes em cada classe, que foram submetidas aos raios X para a obtenção das imagens dos embriões. Os embriões, de cada uma das classes, foram separados de acordo com suas características morfológicas em 4 categorias (embriões sem defeito, embriões com pequenos defeitos, embriões deformados e sementes sem embrião). As sementes das diferentes classes de massa foram colocadas para germinar (emissão da raiz primária) e após dez dias foi observado o número de plântulas normais em cada uma das categorias e classes de massa. A maioria das sementes das classes 1 e 2, mais leves, apresenta-se com embriões deformados ou sem embrião, enquanto que as de maior massa (classes 3 a 7) apresentam embriões sem defeitos, em sua maioria ou totalidade. Quase a totalidade das sementes com embriões sem defeito germina, porém, nem todas dão origem a plântulas normais.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A fast, simple, non-destructive method for the direct screening of polycyclic aromatic hydrocarbons (PAHs) in vegetable oil samples is proposed. The method uses a supercritical fluid extraction (SFE) system coupled on-line with a fluorimetric detector to determine PAHs. This special assembly avoids the main problems encountered in the determination of PAHs in complex matrices such as vegetable oils. PAHs are selectively extracted by using silica gel in the thimble and cleaned up by passage through a C18 column. Interferences are preferentially retained by the silica gel during the SFE process while PAHs are adsorbed in the C18 column and the remainder of the matrix is sent to waste. Finally, the C18 column is purged to remove residual CO2 gas and adsorbed PAHs are recovered by desorption with a solvent. The extracts from positive samples are subsequently analyzed by liquid chromatography (LC) with fluorescence detection. The proposed method allows the confirmation of vegetable oil safety and hence provides a new tool for consumer protection. (C) 2004 Elsevier B.V. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The phase transition from the non-polar a-phase to the polar beta-phase of poly(vinylidene fluoride) (PVDF) has been investigated using micro-Raman spectroscopy, which is advantageous for being a non-destructive technique. Films of alpha-PVDF were subjected to stretching under controlled rates and at 80 degrees C, the transition to beta-PVDF being monitored by the decrease in the Raman band at 794 cm(-1) characteristic of the a-phase, with the concomitant increase in the 839 cm(-1) band characteristic of the beta-phase. Poling with negative corona discharge was found to affect the alpha-PVDF morphology improving the Raman bands related to this crystalline phase. This effect is minimized for films stretched to higher ratios. Significantly, corona-induced effects could not be observed with the other experimental techniques, viz. X-ray diffraction and infrared spectroscopy.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose: To evaluate the 1-year clinical performance of three self-etching adhesives (Adper Prompt L-Pop, Clearfil S-3 Bond, iBond) in posterior composite restorations using one etch&rinse adhesive (One-Step Plus) as control. Methods: Upon approval by the Institutional Review Board, 121 restorations were inserted in 38 subjects. The adhesives were applied as per manufacturers' instructions. Preparations were restored with a nanofilled resin composite (Filtek Supreme) and evaluated at baseline, 6 months, and 1 year. Statistical analyses included the Chi-square distribution with the McNemar non-parametric test (P< 0.05). Results: At 1 year, 111 restorations in 35 subjects were evaluated using the USPHS modified criteria. No significant changes were observed for the etch&rinse adhesive One-Step Plus. At 1 year the number of Alfa ratings decreased significantly for Clearfil S-3 Bond and for iBond in the categories color match, marginal staining, and marginal adaptation. For Adper Prompt L-Pop, marginal adaptation at 1 year was significantly worse than at baseline. Postoperative sensitivity to air improved significantly for Adper Prompt L-Pop, Clearfil S-3 Bond, and iBond. When the evaluation criteria were paired at 1 year, iBond resulted in a significantly lower number of Alfa ratings than any of the other adhesives for color match, marginal staining, and marginal adaptation. One-Step Plus resulted in a greater number of Alfa ratings for marginal adaptation than either Adper Prompt L-Pop or Clearfil S-3 Bond. Marginal adaptation was significantly better for Clearfil S-3 Bond than for Adper Prompt L-Pop. The post-operative sensitivity measured at 1 year for Adper Prompt L-Pop was statistically better than that for One-Step Plus.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Electrochemical noise (EN) is a generic term describing the phenomenon of spontaneous fluctuations of potential or current noise of electrochemical systems. Since this technique provides a non-destructive condition for investigating corrosion processes, it can be useful to study the electrochemical oxidation of mineral sulfides by microorganisms, a process known as bacterial leaching of metals. This technique was utilized to investigate the dissolution of a bornite electrode in the absence (first 79 h) and after the addition of Acidithiobacillus ferrooxidans (next 113 h) in salts mineral medium at pH 1.8, without addition of the energy source (Fe2+ ions) for this chemolithotrophic bacterium. Potential and current noise data have been determined simultaneously with two identical working bornite electrodes which were linked by a zero resistance ammeter (ZRA). The mean potential, E-coup, coupling current, I-coup, standard deviations of potential and current noise fluctuations and noise resistance, R-n, have been obtained for coupled bornite electrodes. Noise measurements were recorded twice a day in an unstirred solution at 30 degrees C. Significant changes in these parameters were observed when the A. ferrooxidans suspension was added, related with bacterial activity on reduced species present in the sulfide moisture (Fe2+, S2-). ENA was a suitable tool for monitoring the changes of the corrosion behavior of bornite due to the presence of bacterium. (C) 2006 Elsevier B.V. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This work presents a review of recent developments in phase-stepping real-time holographic interferometry with photorefractive sillenite crystals. Quantitative results are shown in micro-rotation, micro-displacement, and micro-deformation measurements, and in wave-optics and surface analysis as well. The phase stepping was carried out in a four-frame process and the resulting phase map was unwrapped by applying a sin/cos filter. The experimental results are in good agreement with the ones obtained through other means, showing the promising potentialities of phase-stepping real-time holographic interferometry for in situ visualisation, monitoring and analysis in non-destructive testing.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background. To evaluate insulin release and insulin sensitivity in women with prior gestational diabetes mellitus (GDM) to gain a better understanding of type 2 diabetes pathogenesis.Methods. GDM women were individually matched for age, body mass index, and waist/hip ratio with those who were normal glucose tolerant in a previous pregnancy (NGT). All women presented with normal glucose tolerance. Twenty pairs were submitted to the oral glucose tolerance test (OGTT) with plasma glucose, insulin, and C-peptide determinations. of the 20 pairs, 18 participated in hyperglycemic (10.0 mmol/l) clamp experiments with frequent plasma glucose and insulin determinations, allowing us to calculate first- and second-phase insulin release and the insulin sensitivity index. GDM and NGT women were compared using Student's t-test, the Mann-Whitney U-test, Friedman's non-parametric test, and the two proportion test for independent groups.Results. GDM women showed higher glycosylated hemoglobin values; at OGTT, they showed late insulin peak with increased plasma insulin levels only during the second hour, and a similar plasma C-peptide response despite a higher plasma glucose curve; during hyperglycemic clamp procedures, they showed similar biphasic insulin release and insulin sensitivity index. Considering that a woman with previous GDM had a defect in insulin release and/or insulin sensitivity, if its magnitude was at least 25% lower than that of the matched NGT woman, 43.8% showed impairment of first-phase insulin release and 55.6% insulin resistance.Conclusions. GDM women showed some degree of glucose intolerance. It is therefore necessary to follow them for a longer time.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)