809 resultados para misure sperimentali localizzazione indoor ranging reti wireless
Resumo:
This thesis considers aspects related to the design and standardisation of transmission systems for wireless broadcasting, comprising terrestrial and mobile reception. The purpose is to identify which factors influence the technical decisions and what issues could be better considered in the design process in order to assess different use cases, service scenarios and end-user quality. Further, the necessity of cross-layer optimisation for efficient data transmission is emphasised and means to take this into consideration are suggested. The work is mainly related terrestrial and mobile digital video broadcasting systems but many of the findings can be generalised also to other transmission systems and design processes. The work has led to three main conclusions. First, it is discovered that there are no sufficiently accurate error criteria for measuring the subjective perceived audiovisual quality that could be utilised in transmission system design. Means for designing new error criteria for mobile TV (television) services are suggested and similar work related to other services is recommended. Second, it is suggested that in addition to commercial requirements there should be technical requirements setting the frame work for the design process of a new transmission system. The technical requirements should include the assessed reception conditions, technical quality of service and service functionalities. Reception conditions comprise radio channel models, receiver types and antenna types. Technical quality of service consists of bandwidth, timeliness and reliability. Of these, the thesis focuses on radio channel models and errorcriteria (reliability) as two of the most important design challenges and provides means to optimise transmission parameters based on these. Third, the thesis argues that the most favourable development for wireless broadcasting would be a single system suitable for all scenarios of wireless broadcasting. It is claimed that there are no major technical obstacles to achieve this and that the recently published second generation digital terrestrial television broadcasting system provides a good basis. The challenges and opportunities of a universal wireless broadcasting system are discussed mainly from technical but briefly also from commercial and regulatory aspect
Resumo:
An air quality evaluation of indoor environments with focus on lower carbonyls was carried out in 50 public places using TO-11A methodology. Formaldehyde levels (ranging from 12.5 to 1034 mg m-3) were above the threshold limit in 49 of 50 analyzed samples while acetaldehyde (ranging from 5.2 to 840 mg m-3) and acetone (ranging from 5.5 to 4839 mg m-3) were respectively bellow the limits of OSHA and NIOSH in all samples. However all samples were bellow the threshold limits suggested by the Brazilian legislation - NR-15. A correlation study between the carbonyls and temperature and humidity was also done.
Resumo:
Simultaneous measurements of outdoor and indoor pollution were performed at three schools in Lisbon. Volatile organic compounds (VOCs), formaldehyde and NO2 were passively monitored over a two-week period. Bacterial and fungal colony-forming units and comfort parameters were also monitored at classrooms and playgrounds. The highest indoor levels of CO2 (2666 μg/m³), NO2 (40.3 μg/m³), VOCs (10.3 μg/m³), formaldehyde (1.03 μg/m³) and bioaerosols (1634 CFU/m³), and some indoor/outdoor ratios greater than unity, suggest that indoor sources and building conditions might have negative effects on air indoors. Increasing ventilation rates and use of low-emission materials would contribute towards improving indoor air quality.
Resumo:
Atmospheric pollutants can have serious impacts on the preservation of São Paulo's tangible cultural heritage. The purpose of this paper is to report the results of a monitoring campaign focussed on particulate matter (PM) that was conducted in three of the most important museums of the São Paulo megacity (Brazil): the Museu de Arqueologia e Etnologia (MAE-USP), the Museu Paulista (MP-USP), and the Pinacoteca do Estado de São Paulo (PE). These museums exhibit indoor PM and black carbon (BC) concentrations consistent with their urban locations and their specific methods for managing the indoor environment.
Resumo:
@450 wireless broadband service is Digita’s mobile wireless broadband network service. In @450 network Digita acts as the network operator offering network capacity to service operators. For Digita it is important to know what kind of services its network is capable of and what are the network’s service parameters. The knowledge of the network parameters and the behaviour can be used in advance in the development of new service products. Before a new service product can be offered to service operators a lot of work has to be done. The basic testing is necessary to get an understanding of the basic functionality. The requirement specification has to be done and a new product has to be created. The new product has to be tested. The test results have to be analysed in order to find out if the new product is suitable for real use and with which limitations. The content of this Thesis is the development of wireless technologies, @450 service and network, FLASH-OFDM technology, FLASH-OFDM performance testing and the development of a new service product.
Resumo:
The number of autonomous wireless sensor and control nodes has been increasing rapidly during the last decade. Until recently, these wireless nodes have been powered with batteries, which have lead to a short life cycle and high maintenance need. Due to these battery-related problems, new energy sources have been studied to power wireless nodes. One solution is energy harvesting, i.e. extracting energy from the ambient environment. Energy harvesting can provide a long-lasting power source for sensor nodes, with no need for maintenance. In this thesis, various energy harvesting technologies are studied whilst focusing on the theory of each technology and the state-of-the-art solutions of published studies and commercial solutions. In addition to energy harvesting, energy storage and energy management solutions are also studied as a subsystem of a whole energy source solution. Wireless nodes are also used in heavy-duty vehicles. Therefore a reliable, long-lasting and maintenance-free power source is also needed in this kind of environment. A forestry harvester has been used as a case study to study the feasibility of energy harvesting in a forestry harvester’s sliding boom. The energy harvester should be able to produce few milliwatts to power the target system, an independent limit switch.
Resumo:
Broadcasting systems are networks where the transmission is received by several terminals. Generally broadcast receivers are passive devices in the network, meaning that they do not interact with the transmitter. Providing a certain Quality of Service (QoS) for the receivers in heterogeneous reception environment with no feedback is not an easy task. Forward error control coding can be used for protection against transmission errors to enhance the QoS for broadcast services. For good performance in terrestrial wireless networks, diversity should be utilized. The diversity is utilized by application of interleaving together with the forward error correction codes. In this dissertation the design and analysis of forward error control and control signalling for providing QoS in wireless broadcasting systems are studied. Control signaling is used in broadcasting networks to give the receiver necessary information on how to connect to the network itself and how to receive the services that are being transmitted. Usually control signalling is considered to be transmitted through a dedicated path in the systems. Therefore, the relationship of the signaling and service data paths should be considered early in the design phase. Modeling and simulations are used in the case studies of this dissertation to study this relationship. This dissertation begins with a survey on the broadcasting environment and mechanisms for providing QoS therein. Then case studies present analysis and design of such mechanisms in real systems. The mechanisms for providing QoS considering signaling and service data paths and their relationship at the DVB-H link layer are analyzed as the first case study. In particular the performance of different service data decoding mechanisms and optimal signaling transmission parameter selection are presented. The second case study investigates the design of signaling and service data paths for the more modern DVB-T2 physical layer. Furthermore, by comparing the performances of the signaling and service data paths by simulations, configuration guidelines for the DVB-T2 physical layer signaling are given. The presented guidelines can prove useful when configuring DVB-T2 transmission networks. Finally, recommendations for the design of data and signalling paths are given based on findings from the case studies. The requirements for the signaling design should be derived from the requirements for the main services. Generally, these requirements for signaling should be more demanding as the signaling is the enabler for service reception.
Experimental evaluation of the performance of a wireless sensor network in agricultural environments
Resumo:
The aim of this study was to perform an experimental study to evaluate the proper operation distance between the nodes of a wireless sensor network available on the market for different agricultural crops (maize, physic nut, eucalyptus). The experimental data of the network performance offers to farmers and researchers information that might be useful to the sizing and project of the wireless sensor networks in similar situations to those studied. The evaluation showed that the separation of the nodes depends on the type of culture and it is a critical factor to ensure the feasibility of using WSN. In the configuration used, sending packets every 2 seconds, the battery life was about four days. Therefore, the autonomy may be increased with a longer interval of time between sending packets.
Resumo:
Capybaras (Hydrochaeris hydrochaeris) are among the main hosts of Amblyomma spp. ticks, which is able to transmit Rickettsia species to human beings and animals. Since they are often infested with potential vector ticks, capybaras may be used as sentinels for rickettsiosis, such as the Brazilian Spotted Fever. The aim of the present study was to determine the prevalence of antibodies against Rickettsia spp. using the indirect immunofluorescence assay (IFA) in 21 free-ranging and 10 captive animals from the Zoological Park of the 'Bela Vista Biological Sanctuary' (BVBS), Itaipu Binational, Foz do Iguaçu, Southern Brazil. Antigens of six rickettsial species already identified in Brazil (Rickettsia rickettsii, R. parkeri, R. bellii, R. rhipicephali, R. amblyommii and R. felis) were used for IFA. Ticks from each capybara were collected for posterior taxonomic identification. A total of 19 (61.3%) samples reacted to at least one of tested species. Seropositivity was found in 14 (45.2%), 12 (38.7%), 5 (16.1%), 4 (12.9%), 3 (9.7%) and 3 (9.7%) animals for R. rickettsii, R. bellii, R. parkeri, R. amblyommii, R. felis and R. rhipicephali, respectively. Two captive capybaras presented suggestive titers of R. rickettsii infection and one sample showed homologous reaction to R. parkeri. Only one free-ranging capybara presented evidence R. bellii infection. Ticks collected on capybaras were identified as Amblyomma dubitatum e Amblyomma sp. Results evidenced the rickettsial circulation in the area, suggesting a potential role of capybaras on bacterial life cycle.
Resumo:
Abstract:A serological survey for antibodies against Leptospira interrogans, Brucella abortus, and Chlamydophila abortus was conducted in 21 clinically healthy, free-ranging giant ant- eaters (Myrmecophaga tridactyla) from Parque Nacional das Emas (Goiás State, Brazil; n=6), Parque Nacional da Serra da Canastra (Minas Gerais State, Brazil; n=9), and RPPN SESC Pantanal (Mato Grosso State, Brazil; n=6) between July 2001 and September 2006. Sera were screened for antibodies against 22 serovars of Leptospira interrogans with a microscopic agglutination test. Twelve tested positive for L. interrogansserovars sentot (n=5 in PN Emas, n=2 in PN Serra da Canastra), butembo (n=2 in PN Serra da Canastra), autumnalis, bataviae, and shermani/icterohaemorrhagiae(n=1 each in SESC Pantanal)One adult female tested positive for B. abortus with the buffered plate antigen test. All sera were negative for C. abortususing the complement fixation text. This is the first report of pathogens that may interfere with the reproduction and population dynamics of free-ranging giant anteaters.
Resumo:
Abstract: The Brazilian savanna, also known as Cerrado, is one of the world's richest and most ecologically invaluable tropical savanna regions. There are few studies in Brazil about the diseases that affect the wild canids of this biome, which may be harmful to wildlife populations and public health. The aim of this study was to evaluate the occurrence of antibodies against Leptospira spp. in three Cerrado wild canids species using the microscopic agglutination test (MAT). Serum samples were tested from 19 crab-eating foxes (Cerdocyon thous), 14 maned wolves (Chrysocyon brachyurus), and seven hoary foxes (Lycalopex vetulus), all free-ranging animals found in the municipalities of Araguari and Uberlândia, Minas Gerais State, and Cumari, Goiás State, Brazil. Fourteen (35%) of these samples were seropositive. The most frequent serovars detected in the samples were Copenhageni and Hardjo, but reactions to the serovars Autumnalis, Grippotyphosa, Hebdomadis, Wolffi, and Icterohaemorrhagiae also occurred. Notwithstanding other reported results, this study is the first to report the presence of antibodies against Leptospira spp. in L. vetulus. The three species of wild canids examined may act as potential hosts for several serovars of leptospira in Brazil's savanna environment.
Resumo:
In this report are described means for indoor localization in special, challenging circum-stances in marine industry. The work has been carried out in MARIN project, where a tool based on mobile augmented reality technologies for marine industry is developed. The tool can be used for various inspection and documentation tasks and it is aimed for improving the efficiency in design and construction work by offering the possibility to visualize the newest 3D-CAD model in real environment. Indoor localization is needed to support the system in initialization of the accurate camera pose calculation and auto-matically finding the right location in the 3D-CAD model. The suitability of each indoor localization method to the specific environment and circumstances is evaluated.
Resumo:
Waste has been incinerated for energy utilization for more than a hundred years, but the harmful emissions emitted from the incineration plants did not begin to cause concern until the 1980s. Many plants were shutdown and the waste incineration plant in Kyläsaari Helsinki was one of them. In later years, new landfill regulations have increased the interest in waste incineration. During the last year, four new plants were taken into operation in Finland, Westenergy in Vaasa among them. The presence of dust has been observed indoors at Westenergy waste incineration plant. Dust is defined as particles with a diameter above 10 μm, while fine particles have a diameter smaller than 2.5 μm, ultrafine under 0.1 μm and nanoparticles under 0.05 μm. In recent years, the focus of particle health research has been changed to investigate smaller particles. Ultrafine particles have been found to be more detrimental to health than larger particles. Limit values regulating the concentrations of ultrafine particles have not been determined yet. The objective of this thesis was to investigate dust and particles present inside the Westenergy waste incineration facility. The task was to investigate the potential pollutant sources and to give recommendations of how to minimize the presence of dust and particles in the power plant. The total particle number concentrations and size distributions where measured at 15 points inside the plant with an Engine Exhaust Particle Sizer (EEPS) Spectrometer. The measured particles were mainly in the ultrafine size range. Dust was only visually investigated, since the main purpose was to follow the dust accumulation. The measurement points inside the incineration plant were chosen according to investigate exposure to visitors and workers. At some points probable leakage of emissions were investigated. The measurements were carried out during approximately one month in March–April 2013. The results of the measurements showed that elevated levels of dust and particles are present in the indoor air at the waste incineration plant. The cleanest air was found in the control room, warehouse and office. The most polluted air was near the sources that were investigated due to possible leakage and in the bottom ash hall. However, the concentrations were near measured background concentrations in European cities and no leakage could be detected. The high concentrations were assumed to be a result of a lot of dust and particles present on surfaces that had not been cleaned in a while. The main source of the dust and particles present inside the waste incineration plant was thought to be particles and dust from the outside air. Other activities in the area around the waste incineration facility are ground work activities, stone crushing and traffic, which probably are sources of particle formation. Filtration of the outside air prior entering the facility would probably save personnel and visitors from nuisance and save in cleaning and maintenance costs.