948 resultados para liquid-solid extraction
Resumo:
A phenolic fraction was obtained from of the acetone-water-acetic acid extract of Inga edulis leaves, by liquid-liquid partition and SPE-C18 cartridges. This method provided an increase of 108, 66, 51, 50 and 36% of flavonols, proanthocyanidins, total polyphenols, gallotannins and flavanols, respectively. The major phenolics in purified fraction were procyanidin B2, catechin and myricetin-3-O-α-L-rhamnopyranoside, which achieved increases of 111, 47 and 45%, respectively, after SPE. Acid hydrolysis confirmed the presence of procyanidins, prodelphinidins and glycosylated flavonoids.
Resumo:
A liquid chromatography method was developed and validated for the determination of phenobarbital in human plasma using phenytoin as internal standard. The drugs were extracted from plasma by liquid-liquid extraction and separated isocratically on a C12 analytical column, maintained at 35 ºC, with water:acetonitrile:methanol (58.8:15.2:26, v/v/v) as mobile phase, run at a flow rate of 1.2 mL/min with detection at 205 nm. The method was linear in the range of 0.1-4 μg/mL (r²=0.9999) and demonstrated acceptable results for the precision, accuracy and stability studies. The method was successfully applied for the bioequivalence study of two tablet formulations (test and reference) of phenobarbital 100 mg after single oral dose administration to healthy human volunteers.
Resumo:
Decomposition of carbon tetrachloride in a DC thermal plasma reactor was investigated in argon atmosphere. The operational parameters such as plasma torch power and argon flow rate versus CCl4 conversion were examined. The CCl4 net degradation was determined by GC-FID, the chlorine produced was quantified by iodometric titration, the solid carbon was characterised by Raman spectroscopy and by BET analysis. The solid carbon collected inside de plasma reactor was submitted to solid/liquid extraction and the desorbed species were identified by GC-MS.
Resumo:
This work shows results on the characterization, by liquid chromatography coupled to high resolution tandem mass spectrometry (LC-IT-TOF-MS) with electrospray ionization, of organic compounds present in raw and treated effluents from a combined sewage treatment systems (upflow anaerobic sludge blanket-trickling filter). The sewage samples were prepared by C18 solid phase extraction and the spectra obtained from the various extracts were submitted to principal component analysis to evaluate their pattern and identify the major deprotonated species. Some target compounds were submitted to semiquantitative analysis, using phenolphtalein as internal standard. The results showed the anaerobic step had little impact on the removal of anionic surfactants (LAS), fatty acids, and some contaminantes such as bisphenol A and bezafibrate, whereas the aerobic post-treatment was very efficient in removing these organics.
Resumo:
The restricted availability of water sources suitable for consumption and high costs for obtaining potable water has caused an increase of the conscience concerning the use. Thus, there is a high demand for "environmentally safe methods" which are according to the principles of Green Chemistry. Moreover, these methods should be able to provide reliable results for the analysis of water quality for various pollutants, such as phenol. In this work, greener alternatives for sample preparation for phenol determination in aqueous matrices are presented, which include: liquid phase microextraction, solid phase microextraction, flow analysis, cloud point extraction and aqueous two-phase systems.
Resumo:
An analytical procedure to quantify 3-benzophenone, octylmethoxycinnamate and octylsalicylate was validated and employed to assess these ultraviolet filters in sunscreen formulations and from skin penetration studies. The effect of the vehicle on the skin retention of these filters was investigated. HPLC and extraction procedure were found to be reliable when obtaining data for the sunscreen formulations and for evaluation skin penetration. The results demonstrated that a cream gel generated higher epidermal concentrations of these filters than a lotion or cream-based formulation. Additionally, when comparing the skin retentions of each filter using the same formulation, 3-benzophenone showed the highest skin retention.
Resumo:
A simple ion pair-dispersive liquid-liquid microextraction method was proposed for preconcentration trace amounts of rhodium. An ion association complex of RhCl4- and tetradecyldimetylbenzylamonium was extracted into cholorobenzene. The volume and the type of extractive and dispersive solvents, the extraction time and the pH of the aqueous solutions were optimized. The calibration curve was linear in the range of 0.6-500 ng mL-1 of rhodium. The limit of detection was 0.10 ng mL-1 in initial solution and preconcentration factor was 40. The proposed method was successfully applied to the extraction and determination of rhodium in road dust and water samples.
Resumo:
The determination of pesticide residues in water samples by Liquid Chromatography require sample preparation for extraction and enrichment of the analytes with the minimization of interferences to achieve adequate detection limits. The Solid Phase Extraction (SPE), Solid Phase Microextraction (SPME), Stir Bar Sorptive Extraction (SBSE) and Dispersive Liquid-Liquid Microextraction (DLLME) techniques have been widely used for extraction of pesticides in water. In this review, the principles of these sample preparation techniques associated with the analysis by Liquid Chromatography with Diode Array Detection (LC-DAD) or Mass Spectrometry (LC-MS) are described and an overview of several applications were presented and discussed.
Resumo:
In the proposed method, carbon tetrachloride and ethanol were used as extraction and dispersive solvents. Several factors that may be affected on the extraction process, such as extraction solvent, disperser solvent, the volume of extraction and disperser solvent, pH of the aqueous solution and extraction time were optimized. Under the optimal conditions, linearity was maintained between 1.0 ng mL-1 to 1.5 mg mL-1 for zinc and 1.0 ng mL-1 to 0.4 mg mL-1 for cadmium. The proposed method has been applied for determination of trace amount of zinc and cadmium in standard and water samples with satisfactory results.
Resumo:
A dispersive liquid-liquid microextraction based on solidification of floating organic drop for simultaneous extraction of trace amounts of nickel, cobalt and copper followed by their determination with electrothermal atomic absorption spectrometry was developed. 300 µL of acetone and 1-undecanol was injected into an aqueous sample containing diethyldithiocarbamate complexes of metal ions. For a sample volume of 10 mL, enrichment factors of 277, 270 and 300 and detection limits of 1.2, 1.1 and 1 ng L-1 for nickel, cobalt and copper were obtained, respectively. The method was applied to the extraction and determination of these metals in different water samples.
Resumo:
Analytical methods were developed and validated to determine residues of veterinary drugs in buffalo milk and meat, using the QuEChERS method and gas chromatography-mass spectrometry. Both milk and meat, at 2 g of sample, 4 mL of acetonitrile, 0.8 g of MgSO4 and 0.2 g of NaCl, were used in the liquid-liquid partition, whereas 50 mg of C18, 50 mg of PSA and 150 mg of MgSO4 were employed in the dispersive solid-phase extraction (d-SPE). The methods showed sensitivity, precision and accuracy. The quantitation limits were in agreement with the maximum residue limit established by the Codex Alimentarius, FAO and WHO.
Resumo:
This is an overview of LC-MS techniques applied for macrolide determination in food, including sample preparation and method validation, as well as the policies adopted by international agencies regarding their presence in food. Techniques for the analysis of macrolides in food normally include solid phase or liquid-liquid extraction followed by HPLC. UHPLC presents advantages in running time, detectability and solvent consumption. Triple-quadrupoles are the most common analyzers in instruments used for the determination of contaminants in food, but time-of-flight and ion-trap spectrometers have been successfully applied for analyses focusing on the investigation of structural formula or the presence of degradation products.
Resumo:
We developed a simple, rapid, and solventless method for analyzing trihalomethanes in beer samples using headspace solid-phase microextraction. The effects of varying experimental parameters, such as extraction temperature and time, addition of sodium chloride, and agitation speed, on extraction yield were studied using a univariate experimental design. Limits of detection between 0.22 and 0.46 µg L- 1 and wide linear ranges were achieved for trihalomethanes. We measured the trihalomethane recoveries and precision (as the standard deviation of repeat measurements) and demonstrated the applicability of the proposed method by analyzing 32 beer samples.
Resumo:
In this paper, we describe the synthesis of an ion imprinted polymer (IIP) by homogeneous polymerization and its use in solid-phase to extract and preconcentrate zinc ions. Under optimal conditions (pH 5.0, preconcentration flow rate of 12.0 mL min-1, and eluted with 1.0 mol L-1 HNO3) this procedure allows the determination of zinc with an enrichment factor of 10.2, and with limits of detection and quantification of 1.5 and 5.0 µg L-1, respectively. The accuracy of our results was confirmed by analysis of tap water and certified reference materials: NIST 1570a (Spinach leaves) and NIST 1515 (Apple leaves).
Resumo:
A method was developed for the analysis of 31 pharmaceutical compounds in Lisbon's drinking water system, using solid-phase extraction (SPE) and ultra-performance liquid chromatography coupled to tandem mass spectrometry (UPLC-MS/MS). The method was validated through estimation of the linearity range, method detection and quantification limits, matrix effects, precision and accuracy. The method detection and quantification limit ranges were 0.009-10 and 0.03-33 ng/L, respectively. Analytes were quantified in water samples collected from the EPAL (Empresa Portuguesa das Águas Livres S.A.) supply system. Carbamazepine, atenolol, sulfadiazine, sulfamethazine, sulfapyridine, sulfamethoxazole, acetaminophen, caffeine and erythromycin were quantified in the analysed samples.