872 resultados para integration of care


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Two major difficulties arise when taking blood samples in children: the challenge of venous access and the comparatively large amount of blood required.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

After decades of development in programming languages and programming environments, Smalltalk is still one of few environments that provide advanced features and is still widely used in the industry. However, as Java became prevalent, the ability to call Java code from Smalltalk and vice versa becomes important. Traditional approaches to integrate the Java and Smalltalk languages are through low-level communication between separate Java and Smalltalk virtual machines. We are not aware of any attempt to execute and integrate the Java language directly in the Smalltalk environment. A direct integration allows for very tight and almost seamless integration of the languages and their objects within a single environment. Yet integration and language interoperability impose challenging issues related to method naming conventions, method overloading, exception handling and thread-locking mechanisms. In this paper we describe ways to overcome these challenges and to integrate Java into the Smalltalk environment. Using techniques described in this paper, the programmer can call Java code from Smalltalk using standard Smalltalk idioms while the semantics of each language remains preserved. We present STX:LIBJAVA - an implementation of Java virtual machine within Smalltalk/X - as a validation of our approach

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Integration of indigenous knowledge and ethnoscientific approaches into contemporary frameworks for conservation and sustainable management of natural resources will become increasingly important in policies on an international and national level. We set the scene on how this can be done by exploring the key conditions and dimensions of a dialogue between ‘ontologies’ and the roles, which ethnosciences could play in this process. First, the roles which ethnosciences in the context of sustainable development were analysed, placing emphasis on the implications arising when western sciences aspire to relate to indigenous forms of knowledge. Secondly, the contributions of ethnosciences to such an ‘inter-ontological dialogue’ were explored, based on an ethnoecological study of the encounter of sciences and indigenous knowledge in the Andes of Bolivia, and reviewed experiences from mangrove systems in Kenya, India and Sri Lanka, and from case-studies in other ecosystems world-wide.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: This project is part of an evaluation of complementary and alternative medicine (CAM) aimed at providing a scientific basis for the Swiss Government to include 5 CAM methods in basic health coverage: anthroposophic medicine, homeopathy, neural therapy, phytotherapy and Traditional Chinese Medicine (TCM). OBJECTIVES: The objective was to explore the philosophy of care (convictions and values, priorities in medical activity, motivation for CAM, criteria for the practice of CAM, limits of the used methods) of conventional and CAM general practitioners (GPs) and to determine differences between both groups. MATERIALS AND METHODS: This study was a cross-sectional survey of a representative sample of 623 GPs who provide complementary or conventional primary care. A mailed questionnaire with open-ended questions focusing on the philosophy of care was used for data collection. An appropriate methodology using a combination of quantitative and qualitative approaches was developed. RESULTS: Significant differences between both groups include philosophy of care (holistic versus positivistic approaches), motivation for CAM (intrinsic versus extrinsic) and priorities in medical activity. Both groups seem to be aware of limitations of the therapeutic methods used. The study reveals that conventional physicians are also using complementary medicine. DISCUSSION: Our study provides a wealth of data documenting several aspects of physicians' philosophy of care as well as differences and similarities between conventional and complementary care. Implications of the study with regard to quality of care as well as ethical and health policy issues should be investigated further.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Point-of-care testing (POCT) remains under scrutiny by healthcare professionals because of its ill-tried, young history. POCT methods are being developed by a few major equipment companies based on rapid progress in informatics and nanotechnology. Issues as POCT quality control, comparability with standard laboratory procedures, standardisation, traceability and round robin testing are being left to hospitals. As a result, the clinical and operational benefits of POCT were first evident for patients on the operating table. For the management of cardiovascular surgery patients, POCT technology is an indispensable aid. Improvement of the technology has meant that clinical laboratory pathologists now recognise the need for POCT beyond their high-throughput areas.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: The Roche CARDIAC proBNP point-of-care (POC) test is the first test intended for the quantitative determination of N-terminal pro-brain natriuretic peptide (NT-proBNP) in whole blood as an aid in the diagnosis of suspected congestive heart failure, in the monitoring of patients with compensated left-ventricular dysfunction and in the risk stratification of patients with acute coronary syndromes. METHODS: A multicentre evaluation was carried out to assess the analytical performance of the POC NT-proBNP test at seven different sites. RESULTS: The majority of all coefficients of variation (CVs) obtained for within-series imprecision using native blood samples was below 10% for both 52 samples measured ten times and for 674 samples measured in duplicate. Using quality control material, the majority of CV values for day-to-day imprecision were below 14% for the low control level and below 13% for the high control level. In method comparisons for four lots of the POC NT-proBNP test with the laboratory reference method (Elecsys proBNP), the slope ranged from 0.93 to 1.10 and the intercept ranged from 1.8 to 6.9. The bias found between venous and arterial blood with the POC NT-proBNP method was < or =5%. All four lots of the POC NT-proBNP test investigated showed excellent agreement, with mean differences of between -5% and +4%. No significant interference was observed with lipaemic blood (triglyceride concentrations up to 6.3 mmol/L), icteric blood (bilirubin concentrations up to 582 micromol/L), haemolytic blood (haemoglobin concentrations up to 62 mg/L), biotin (up to 10 mg/L), rheumatoid factor (up to 42 IU/mL), or with 50 out of 52 standard or cardiological drugs in therapeutic concentrations. With bisoprolol and BNP, somewhat higher bias in the low NT-proBNP concentration range (<175 ng/L) was found. Haematocrit values between 28% and 58% had no influence on the test result. Interference may be caused by human anti-mouse antibodies (HAMA) types 1 and 2. No significant influence on the results with POC NT-proBNP was found using volumes of 140-165 muL. High NT-proBNP concentrations above the measuring range of the POC NT-proBNP test did not lead to false low results due to a potential high-dose hook effect. CONCLUSIONS: The POC NT-proBNP test showed good analytical performance and excellent agreement with the laboratory method. The POC NT-proBNP assay is therefore suitable in the POC setting.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Individual monitoring regulations in Switzerland are based on the ICRP60 recommendations. The annual limit of 20 mSv for the effective dose applies to the sum of external and internal radiation. External radiation is monitored monthly or quarterly with TLD, DIS or CR-39 dosemeters by 10 approved external dosimetry services and reported as H(p)(10) and H(p)(0.07). Internal monitoring is done in two steps. At the workplace, simple screening measurements are done frequently in order to recognise a possible incorporation. If a nuclide dependent activity threshold is exceeded then one of the seven approved dosimetry services for internal radiation does an incorporation measurement to assess the committed effective dose E(50). The dosimetry services report all the measured or assessed dose values to the employer and to the National Dose Registry. The employer records the annually accumulated dose values into the individual dose certificate of the occupationally exposed person, both the external dose H(p)(10) and the internal dose E(50) as well as the total effective dose E = H(p)(10)+E(50). Based on the national dose registry an annual report on the dosimetry in Switzerland is published which contains the statistics for the total effective dose, as well as separate statistics for external and internal exposure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the past, several modifications of specific surface properties such as topography, structure, chemistry, surface charge, and wettability have been investigated to predictably improve the osseointegration of titanium implants. The aim of the present review was to evaluate, based on the currently available evidence, the impact of hydrophilic surface modifications of titanium for dental implants. A surface treatment was performed to produce hydroxylated/hydrated titanium surfaces with identical microstructure to either acid-etched, or sand-blasted, large grit and acid-etched substrates, but with hydrophilic character. Preliminary in vitro studies have indicated that the specific properties noted for hydrophilic titanium surfaces have a significant influence on cell differentiation and growth factor production. Animal experiments have pointed out that hydrophilic surfaces improve early stages of soft tissue and hard tissue integration of either nonsubmerged or submerged titanium implants. This data was also corroborated by the results from preliminary clinical studies. In conclusion, the present review has pointed to a potential of hydrophilic surface modifications to support tissue integration of titanium dental implants.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Molecules are the smallest possible elements for electronic devices, with active elements for such devices typically a few Angstroms in footprint area. Owing to the possibility of producing ultrahigh density devices, tremendous effort has been invested in producing electronic junctions by using various types of molecules. The major issues for molecular electronics include (1) developing an effective scheme to connect molecules with the present micro- and nano-technology, (2) increasing the lifetime and stabilities of the devices, and (3) increasing their performance in comparison to the state-of-the-art devices. In this work, we attempt to use carbon nanotubes (CNTs) as the interconnecting nanoelectrodes between molecules and microelectrodes. The ultimate goal is to use two individual CNTs to sandwich molecules in a cross-bar configuration while having these CNTs connected with microelectrodes such that the junction displays the electronic character of the molecule chosen. We have successfully developed an effective scheme to connect molecules with CNTs, which is scalable to arrays of molecular electronic devices. To realize this far reaching goal, the following technical topics have been investigated. 1. Synthesis of multi-walled carbon nanotubes (MWCNTs) by thermal chemical vapor deposition (T-CVD) and plasma-enhanced chemical vapor deposition (PECVD) techniques (Chapter 3). We have evaluated the potential use of tubular and bamboo-like MWCNTs grown by T-CVD and PE-CVD in terms of their structural properties. 2. Horizontal dispersion of MWCNTs with and without surfactants, and the integration of MWCNTs to microelectrodes using deposition by dielectrophoresis (DEP) (Chapter 4). We have systematically studied the use of surfactant molecules to disperse and horizontally align MWCNTs on substrates. In addition, DEP is shown to produce impurityfree placement of MWCNTs, forming connections between microelectrodes. We demonstrate the deposition density is tunable by both AC field strength and AC field frequency. 3. Etching of MWCNTs for the impurity-free nanoelectrodes (Chapter 5). We show that the residual Ni catalyst on MWCNTs can be removed by acid etching; the tip removal and collapsing of tubes into pyramids enhances the stability of field emission from the tube arrays. The acid-etching process can be used to functionalize the MWCNTs, which was used to make our initial CNT-nanoelectrode glucose sensors. Finally, lessons learned trying to perform spectroscopic analysis of the functionalized MWCNTs were vital for designing our final devices. 4. Molecular junction design and electrochemical synthesis of biphenyl molecules on carbon microelectrodes for all-carbon molecular devices (Chapter 6). Utilizing the experience gained on the work done so far, our final device design is described. We demonstrate the capability of preparing patterned glassy carbon films to serve as the bottom electrode in the new geometry. However, the molecular switching behavior of biphenyl was not observed by scanning tunneling microscopy (STM), mercury drop or fabricated glassy carbon/biphenyl/MWCNT junctions. Either the density of these molecules is not optimum for effective integration of devices using MWCNTs as the nanoelectrodes, or an electroactive contaminant was reduced instead of the ionic biphenyl species. 5. Self-assembly of octadecanethiol (ODT) molecules on gold microelectrodes for functional molecular devices (Chapter 7). We have realized an effective scheme to produce Au/ODT/MWCNT junctions by spanning MWCNTs across ODT-functionalized microelectrodes. A percentage of the resulting junctions retain the expected character of an ODT monolayer. While the process is not yet optimized, our successful junctions show that molecular electronic devices can be fabricated using simple processes such as photolithography, self-assembled monolayers and dielectrophoresis.