932 resultados para happened-before


Relevância:

20.00% 20.00%

Publicador:

Resumo:

STATEMENT OF PROBLEM: Despite careful procedures, master stone dies may be damaged during laboratory procedures. The dentist routinely adjusts castings because the marginal fit of casting is not as accurate as on the dies. PURPOSE: This study evaluated the technique of internal adjustment of castings with use of duplicated stone dies and a disclosing agent to improve marginal fit discrepancy. MATERIAL AND METHODS: Thirty-two nickel-chromium copings were fabricated and simulated standard clinical and laboratory procedures with 2 variables: tooth preparation convergence angles of 6 and 18 degrees, with or without internal relief. Master stone dies and their duplicates were selected for coping construction and internal adjustment, respectively. A specimen positioning device was coupled with a Toolmakers microscope to allow reproducibility of measurements. Each coping was evaluated at 8 locations of its marginal perimeter, before and after internal adjustment. RESULTS: Marginal fit discrepancy of copings were significantly reduced with an internal adjustment technique (mean > 52%) for all experimental groups. Tooth preparations with greater convergence and internally relieved castings recorded a better marginal fit. CONCLUSION: The casting internal adjustment technique with use of duplicated stone dies and a disclosing agent substantially reduced marginal fit discrepancy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The release of fluoride from restorative materials (Vitremer, Ketac-Fil, Fuji II LC and Freedom) was evaluated during two 15-day periods, before and after a topical application of acidulated phosphate fluoride gel (APF). For each material, 6 specimens were made, which were immersed in 2 ml of deionized water. The fluoride concentration dosages in the solutions were read at intervals of 24 hours for 15 days. After this period, the specimens of each material received treatment with APF gel for 4 minutes and the fluoride released was analyzed at 24-hour intervals during the following 15 days. The analysis of variance and the Tukey test (p < 0.05) showed that the total mean fluoride released during the initial 15 days was greater for Vitremer and Ketac-Fil and lower for Fuji II LC and Freedom; and in the final 15 days there was a difference in release readings, with the greatest value for Vitremer, followed by Fuji II LC, Ketac-Fil and Freedom. The comparison of the results between the 1st day and the 16th day (after gel application) showed a greater fluoride release on the 16th day for Vitremer, Fuji II LC and Freedom and was equal for Ketac-Fil. Although all the materials evaluated gained fluoride with the application of APF, the data suggest that the resin-modified ionomers are more efficient in releasing fluoride to the medium than the other materials.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The lake from Porto-Primavera hydroelectric power station inundated an area of 2,200 km2 at the border of São Paulo and Mato-Grosso do Sul States, Brazil. Infestations by ticks were evaluated on 135 marsh deer, Blastocerus dichotomus (Illiger), captured before and after inundation. Ticks were collected for identification, and infestation level of animals was assessed by scoring. Deer were divided into four groups according to capture location and temporal relation to the inundation. Groups 1, 2, and 3 were captured before inundation. Group 4 was captured after inundation. Four tick species were found: Amblyomma cajennense (F.), Amblyomma triste Koch, Anocentor nitens (Neumann), and Boophilus microplus (Canestrini). Groups 1, 2, 3, and 4 had 30, 45, 100, and 96%, respectively, of animals carrying B. microplus ticks. A. triste was observed on 16, 22, 22, and 88% of animals from groups 1,2,3, and 4, respectively. A. nitens and A. cajennense were observed only on group 4, on 32 and 16% of the animals, respectively. Groups 1 and 2 had only 4.8 and 6.1% of animals with high infestation levels, respectively, and no ticks on 46.8% and 45.5% of the animals, respectively. Conversely, groups 3 and 4 lacked noninfested animals and had high infestation levels on 77.8 and 50% of deer, respectively. Marsh area shrinkage was blamed for higher infestation levels on deer from groups 3 and 4. The widespread presence of A. triste on marsh deer, a Neotropical tick species, raises the possibility of a natural host-parasite relationship.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes the ultramorphology and histology of the venom reservoir in 14-day old workers of Apis mellifera, immediately before and after the application of electrical shocks with the object of causing venom elimination and reservoir collapse. The external epithelial surface of the reservoir was differentiated according to its morphological aspects into posterior, median, and proximal or duct regions at the ventral surface and into anterior and posterior regions at the dorsal surface. While the epithelium of the proximal region forms a ventral infolding, a dorsal salience is formed at this region. These structures and the epithelial regions persist both in full and empty reservoirs. The reservoir appeared full and distended before the electrical shocks were applied and became empty and withered afterwards due to the elimination of the secretion, without any reductions in length. Nevertheless, some secretion was kept inside the lumen, thus suggesting a possible role for the reservoir in the modification of the secretion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ipê amarelo Tabebuia chrysotricha (Mart. Ex DC.) Standl. is a native forest species that presents heavy and durable wood: it is common to be used for urban arborization. The species is latte secondary and heliophyta. Occurs from Espirito Santo State until Santa Catarina in the Pluvial Atlantic Forest (Mata Atlântica). The seedling production is hard because their seeds have short longevity after dispersion, and so due to the difficulty to harvest winged seeds that are quickly dispersed by the wind. The present study was carried out to evaluate the physiological maturity of Ipê Amarelo seeds, to establish the best moment to harvest them. The study was to accompany the maturation of 100 fruits in just beginning development, from eleven different trees. Morphological characteristic measures were made weekly, with fruits still on trees, starting from the second week development when fruits presented the following averages: 6.3 cm length, 0.71 cm thickness, and 0.82 cm width. From the sixth week of fruit development we harvest them to proceed the germination test, water content rate, and electric conductivity test. The germination has begun by the seventh week development with 28% of germinated seedlings. The highest germination rate happened by the eighth week development, with 74.5% of germinated seedlings and on the ninth week the rate decrease to 65.5%, when the seeds were already in dispersion. Through the electric conductivity test the highest value obtained was 378.06 μS.g -1.cm -1 on the seventh week development and the lowest one was 183.28 μpS.g -1.cm -1 on eighth week. These results support those obtained in the germination test, because as higher is the electric conductivity of seeds, as higher is their deterioration level. Finally, the study allows concluding that the physiological maturation of ipê amarelo seeds has occurred before dispersion close to the eighth week development when fruits presented the following averages: 22.2 cm length, 1.37 cm width, and 1.05 cm thickness; water content rate was 61.8% and electric conductivity was 183.28 μS.g -1.cm -1. In that moment, the fruits presented greened brown coloration and started to show fissures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: This study assessed the shear bond strength of 4 hard chairside reline resins (Kooliner, Tokuso Rebase Fast, Duraliner II, Ufi Gel Hard) to a rapid polymerizing denture base resin (QC-20) processed using 2 polymerization cycles (A or B), before and after thermal cycling. Materials and Methods: Cylinders (3.5 mm x 5.0 mm) of the reline resins were bonded to cylinders of QC-20 polymerized using cycle A (boiling water-20 minutes) or B (boiling water; remove heat-20 minutes; boiling water-20 minutes). For each reline resin/polymerization cycle combination, 10 specimens (groups CAt e CBt) were thermally cycled (5 and 55°C; dwell time 30 seconds; 2,000 cycles); the other 10 were tested without thermal cycling (groups CAwt ad CBwt). Shear bond tests (0.5 mm/min) were performed on the specimens and the failure mode was assessed. Data were analyzed by 3-way ANOVA and Newman-Keuls post-hoc test (α=.05). Results: QC-20 resin demonstrated the lowest bond strengths among the reline materials (P<.05) and mainly failed cohesively. Overall, the bond strength of the hard chairside reline resins were similar (10.09±1.40 to 15.17±1.73 MPa) and most of the failures were adhesive/cohesive (mixed mode). However, Ufi Gel Hard bonded to QC-20 polymerized using cycle A and not thermally cycled showed the highest bond strength (P<.001). When Tokuso Rebase Fast and Duraliner II were bonded to QC-20 resin polymerized using cycle A, the bond strength was increased (P=.043) after thermal cycling. Conclusions: QC-20 displayed the lowest bond strength values in all groups. In general, the bond strengths of the hard chairside reline resins were comparable and not affected by polymerization cycle of QC-20 resin and thermal cycling.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: This study compared the microtensile bond strength of resin-based cement (Panavia F) to silica-coated, silanized, glass-infiltrated high-alumina zirconia (In-Ceram Zirconia) ceramic in dry conditions and after various aging regimens. Materials and Methods: The specimens were placed in 1 of 4 groups: group 1: dry conditions (immediate testing without aging); group 2: water storage at 37°C for 150 days; group 3: 150 days of water storage followed by thermocycling (× 12,000, 5°C to 55°C); group 4: water storage for 300 days; group 5: water storage for 300 days followed by thermocycling. Results: Group 1 showed a significantly higher microtensile bond strength value (26.2 ± 1 MPa) than the other aging regimens (6.5 ± 1, 6.2 ± 2, 4.5 ± 1, 4.3 ± 1 MPa for groups 2, 3, 4, and 5, respectively) (P < .01). Conclusion: Satisfactory results were seen in dry conditions, but water storage and thermocycling resulted in significantly weaker bonds between the resin cement and the zirconia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed to evaluate the durability of adhesion between acrylic teeth and denture base acrylic resin. The base surfaces of 24 acrylic teeth were flatted and submitted to 4 surface treatment methods: SM1 (control): No SM; SM2: application of a methyl methacrylate-based bonding agent (Vitacol); SM3: air abrasion with 30-μm silicone oxide plus silane; SM4: SM3 plus SM2. A heat-polymerized acrylic resin was applied to the teeth. Thereafter, bar specimens were produced for the microtensile test at dry and thermocyled conditions (60 days water storage followed by 12,000 cycles). The results showed that bond strength was significantly affected by the SM (P < .0001) (SM4 = SM2 > SM3 > SM1) and storage regimens (P < .0001) (dry > thermocycled). The methyl methacrylate-based adhesive showed the highest bond strength.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to assess the electrical activity of the masseter and anterior temporal muscles in patients with severe bone resorption, with complete dentures worn for over ten years, and five months after having new dentures put in place. The RDC questionnaire was applied to twelve asymptomatic patients, before and five months after new dentures were put in place. The electrical activity recordings were made in the mandibular position at rest, and during maximum tooth clenching. The electrical activity of the masseter and anterior temporal muscles in the position at rest presented no statistically significant difference after five months of wearing the new complete dentures. Electrical activity during tooth clenching exhibited a statistically significant reduction only in the right temporal muscle. A period longer than five months of wearing the new complete dentures is required for adaptation and the acquisition of functional capacity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The retention phase is initiated after orthodontic treatment completion to prevent orthodontic relapse. There are several techniques, direct and indirect, available for placing bonded lingual retainers, but none of them is considered as a standard clinical protocol. The best choice should be the association of simplicity and efficiency. This article presents a practical method sequence for fixation of the lingual retainer before direct bonding. © 2009 Elsevier Ltd and the Japanese Orthodontic Society.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fragile X syndrome is a cytogenetic abnormality related to chromosomal X. This syndrome is frequently associated to intellectual disability, psychological problems, as well as heart, skeletal and join alterations. Intraoral anomalies include malloclusion, ogival palate, cleft palate, presence of mesiodens, dental hypomineralization and abrasion of the occlusal surfaces and incisai edges. The study of characteristics of this syndrome is important for the dentist in order to guide dental treatment and prevention. The aim of this study is to present a myofunctional therapy protocol, evaluated by surface electromyography. A case of a 21 year-old young man who attended the Training Program in Dentistry for Persons with Disabilities, School of Dentistry of São José dos Campos/UNESP is reported. He underwent myofunctional therapy before dental treatment and the masticatory muscles were evaluated by surface electromyography. The exercises of myofunctional therapy consisted of active and passive simple movements of opening and closing the mouth, tongue protrusion and retrusion, digital manipulation and also by using an electric massager on intraoral and perioral region of the masseter, buccinator and orbicularis oris. Action potentials of the masticatory muscles decreased in almost all the muscles and values for the bite force and mandibular opening capacity increased. This study showed that brief and immediate myofunctional therapy optimized clinical practice with positive repercussion on dental care.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: Assess the occurrence of secondary brow ptosis after upper lid blepharoplasty. Methods: Forty-five individuals (n90 brows) submitted to upper lid blepharoplasty, were assessed by means of a comparative analysis using pre- and post-operatively digital photographs, in the primary position of the eye. The images were processed using ImageJ software, transferred to a computer, to an electronic Microsoft Excel 2002® worksheet. Angular measurements were used, taking the lateral canthal angle of the brow, the most medial point of the brow, the medial canthal angle and the lateral canthal angle of the lid as anatomical reference points. When the outer angles were reduced or the inner angles increased after surgery this was considered a brow ptosis. Individuals who had undergone lid surgery associated with the eyebrow, previous eyebrow surgery and those with eyelid ptosis were excluded. The difference between the pre-operative and post-operative measurements were analyzed statistically using the Student's t-test for paired samples and the angular variation was compared with their corresponding contralateral sample using Wilcoxon's non-parametric test. Results: The measurements obtained after the blepharoplasty show significant variations from those before the surgery, indicating that the correction of redundant tissues in the brow accentuates the tendency of the eyebrow to move down. The alterations are more important in the lateral portion of the eyebrow and they occur bilaterally. Conclusion: The assessment of angular measurements obtained pre- and post-operatively showed that there are secondary changes in the position of the eyebrow as a result of upper eyelid blepharoplasty. © 2012 Informa Healthcare USA, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The aim of this study was to evaluate the impact of treatment with new complete dentures on oral health-related quality of life and satisfaction of edentulous patients attending the Prosthodontic Department in a Dental School in Brazil. Methods: A total of 70 edentulous subjects (37-86 years) treated by undergradute students at the Araçatuba Dental School, University of State of São Paulo, were accessed. A specific questionnaire for edentulous patients (EDENT) based on the Oral Health Impact Profile (OHIP-EDENT) was applied to collect information on patient oral health-related quality of life. Questions related to the personal satisfaction of the edentulous patients with their complete dentures were also included. The patients were accessed before the treatment, and 3 months after receiving the new dentures. Results: After rehabilitation with new complete dentures, all domains of OHIP-EDENT showed significant improvements. There was also a significant improvement in patient satisfaction after placement of new complete dentures. Furthermore, it was possible to observe association between upper denture satisfaction and age. Conclusion: Conventional complete dentures may have a positive impact on oral health-related quality of life and satisfaction of edentulous patients. © 2012 Japan Prosthodontic Society.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although the safety of living kidney donation has been well established, prospective studies examining the physical and psychosocial aspects of the donor's quality of life are still scarce. Thus, the purpose of this prospective work was to assess the quality of life of 50 consecutive donors before and after kidney transplantation. All donors were asked to respond to both a donor questionnaire and the short-form 36-item health survey (SF-36). Interviews were individually conducted before, three months after, and over one yr after transplantation. Donation was considered a positive experience by all patients and had no impact on any physical or psychosocial aspect of the donor's life. Improved self-esteem and better quality of life after donation were reported in 52% of the cases. All donors would donate again and encouraged donation. SF-36 data indicated improvement in post-donation mental and physical scores among living donors closely related to recipient. Overall, most donors had a positive experience, felt no changes in quality of life, experienced enhanced self-esteem, would donate again, and recommended donation. © 2012 John Wiley & Sons A/S.