995 resultados para guess wave function harmonic oscillator


Relevância:

30.00% 30.00%

Publicador:

Resumo:

We study experimentally the dynamic properties of a fully integrated high power master-oscillator power-amplifier emitting at 1.5 μm under continuous wave and gain-switching conditions. High peak power (2.7 W) optical pulses with short duration (~ 110 ps) have been generated by gain switching the master-oscillator. We show the existence of working points at very close driving conditions with stable or unstable regimes caused by the compound cavity effects. The optical and radio-frequency spectra of stable and unstable operating points are analyzed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The optical and radio-frequency spectra of a monolithic master-oscillator power-amplifier emitting at 1.5 ?m have been analyzed in a wide range of steady-state injection conditions. The analysis of the spectral maps reveals that, under low injection current of the master oscillator, the device operates in two essentially different operation modes depending on the current injected into the amplifier section. The regular operation mode with predominance of the master oscillator alternates with lasing of the compound cavity modes allowed by the residual reflectance of the amplifier front facet. The quasi-periodic occurrence of these two regimes as a function of the amplifier current has been consistently interpreted in terms of a thermally tuned competition between the modes of the master oscillator and the compound cavity modes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The effect of cup anemometer shape parameters, such as the cups’ shape, their size, and their center rotation radius, was experimentally analyzed.This analysis was based on both the calibration constants of the transfer function and the most important harmonic termof the rotor’smovement,which due to the cup anemometer design is the third one.This harmonic analysis represents a new approach to study cup anemometer performances. The results clearly showed a good correlation between the average rotational speed of the anemometer’s rotor and the mentioned third harmonic term of its movement.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A case study of vocal fold paralysis treatment is described with the help of the voice quality analysis application BioMet®Phon. The case corresponds to a description of a 40 - year old female patient who was diagnosed of vocal fold paralysis following a cardio - pulmonar intervention which required intubation for 8 days and posterior tracheotomy for 15 days. The patient presented breathy and asthenic phon ation, and dysphagia. Six main examinations were conducted during a full year period that the treatment lasted consisting in periodic reviews including video - endostroboscopy, voice analysis and breathing function monitoring. The phoniatrician treatment inc luded 20 sessions of vocal rehabilitation, followed by an intracordal infiltration with Radiesse 8 months after the rehabilitation treatment started followed by 6 sessions of rehabilitation more. The videondoscopy and the voicing quality analysis refer a s ubstantial improvement in the vocal function with recovery in all the measures estimated (jitter, shimmer, mucosal wave contents, glottal closure, harmonic contents and biomechanical function analysis). The paper refers the procedure followed and the results obtained by comparing the longitudinal progression of the treatment, illustrating the utility of voice quality analysis tools in speech therapy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The calibration results of one anemometer equipped with several rotors, varying their size, were analyzed. In each case, the 30-pulses pert turn output signal of the anemometer was studied using Fourier series decomposition and correlated with the anemometer factor (i.e., the anemometer transfer function). Also, a 3-cup analytical model was correlated to the data resulting from the wind tunnel measurements. Results indicate good correlation between the post-processed output signal and the working condition of the cup anemometer. This correlation was also reflected in the results from the proposed analytical model. With the present work the possibility of remotely checking cup anemometer status, indicating the presence of anomalies and, therefore, a decrease on the wind sensor reliability is revealed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The transient response of a system of independent electrodes buried in a semi-infinite conducting medium is studied. Using a simple and versatile numerical scheme written by the authors and based on the Electric Field Integral Equation (EFIE), the effect caused by harmonic signals ranging on frequency from Hz to hundred of MHz, and also by lightning type driving signal striking at a remote point far from the conductors, is extensively studied. The value of the scalar potential appearing on the electrodes as a function of the frequency of the applied signal is one of the variables investigated. Other features such as the input impedance at the injection point of the signal and the Ground Potential Rise (GPR) over the electrode system are also discussed

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Integrated master-oscillator power amplifiers driven under steady-state injection conditions are known to show a complex dynamics resulting in a variety of emission regimes. We present experimental results on the emission characteristics of a 1.5 µm distributed feedback tapered master-oscillator power-amplifier in a wide range of steady-state injection conditions, showing different dynamic behaviors. The study combines the optical and radio-frequency spectra recorded under different levels of injected current into the master oscillator and the power amplifier sections. Under low injection current of the master oscillator the correlation between the optical and radio-frequency spectral maps allows to identify operation regimes in which the device emission arises from either the master oscillator mode or from the compound cavity modes allowed by the residual reflectance of the amplifier front facet. The quasi-periodic occurrence of these emission regimes as a function of the amplifier current is interpreted in terms of a thermally tuned competition between the modes of the master oscillator and the compound cavity modes. Under high injection current of the masteroscillator, two different regimes alternate quasi-periodically as a function of the injected current in the power amplifier: a stable regime with a single mode emission at the master oscillator frequency, and an unstable and complex self-pulsating regime showing strong peaks in the radio-frequency spectra as well as multiple frequencies in the optical spectra.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The sequence of events that leads to tumor vessel regression and the functional characteristics of these vessels during hormone–ablation therapy are not known. This is because of the lack of an appropriate animal model and monitoring technology. By using in vivo microscopy and in situ molecular analysis of the androgen-dependent Shionogi carcinoma grown in severe combined immunodeficient mice, we show that castration of these mice leads to tumor regression and a concomitant decrease in vascular endothelial growth factor (VEGF) expression. Androgen withdrawal is known to induce apoptosis in Shionogi tumor cells. Surprisingly, tumor endothelial cells begin to undergo apoptosis before neoplastic cells, and rarefaction of tumor vessels precedes the decrease in tumor size. The regressing vessels begin to exhibit normal phenotype, i.e., lower diameter, tortuosity, vascular permeability, and leukocyte adhesion. Two weeks after castration, a second wave of angiogenesis and tumor growth begins with a concomitant increase in VEGF expression. Because human tumors often relapse following hormone–ablation therapy, our data suggest that these patients may benefit from combined anti-VEGF therapy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose. Mice rendered hypoglycemic by a null mutation in the glucagon receptor gene Gcgr display late-onset retinal degeneration and loss of retinal sensitivity. Acute hyperglycemia induced by dextrose ingestion does not restore their retinal function, which is consistent with irreversible loss of vision. The goal of this study was to establish whether long-term administration of high dietary glucose rescues retinal function and circuit connectivity in aged Gcgr−/− mice. Methods. Gcgr−/− mice were administered a carbohydrate-rich diet starting at 12 months of age. After 1 month of treatment, retinal function and structure were evaluated using electroretinographic (ERG) recordings and immunohistochemistry. Results. Treatment with a carbohydrate-rich diet raised blood glucose levels and improved retinal function in Gcgr−/− mice. Blood glucose increased from moderate hypoglycemia to euglycemic levels, whereas ERG b-wave sensitivity improved approximately 10-fold. Because the b-wave reflects the electrical activity of second-order cells, we examined for changes in rod-to-bipolar cell synapses. Gcgr−/− retinas have 20% fewer synaptic pairings than Gcgr+/− retinas. Remarkably, most of the lost synapses were located farthest from the bipolar cell body, near the distal boundary of the outer plexiform layer (OPL), suggesting that apical synapses are most vulnerable to chronic hypoglycemia. Although treatment with the carbohydrate-rich diet restored retinal function, it did not restore these synaptic contacts. Conclusions. Prolonged exposure to diet-induced euglycemia improves retinal function but does not reestablish synaptic contacts lost by chronic hypoglycemia. These results suggest that retinal neurons have a homeostatic mechanism that integrates energetic status over prolonged periods of time and allows them to recover functionality despite synaptic loss.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

"November 1974."

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Thesis (Ph.D.)--University of Washington, 2016-06

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aims Alpha-lipoic acid (ALA) is a thiol compound with antioxidant properties used in the treatment of diabetic polyneuropathy. ALA may also improve arterial function, but there have been scant human trials examining this notion. This project aimed to investigate the effects of oral and intra-arterial ALA on changes in systemic and regional haemodynamics, respectively. Methods In study 1, 16 healthy older men aged 58 +/- 7 years (mean +/- SD) received 600 mg of ALA or placebo, on two occasions 1 week apart, in a randomized cross-over design. Repeated measures of peripheral and central haemodynamics were then obtained for 90 min. Central blood pressure and indices of arterial stiffness [augmentation index (AIx) and estimated aortic pulse wave velocity] were recorded non-invasively using pulse wave analysis. Blood samples obtained pre- and post-treatments were analysed for erythrocyte antioxidant enzyme activity, plasma nitrite and malondialdehyde. In study 2 the effects of incremental cumulative doses (0.5, 1.0, 1.5 and 2.0 mg ml(-1) min(-1)) of intra-arterial ALA on forearm blood flow (FBF) were assessed in eight healthy subjects (aged 31 +/- 5 years) by conventional venous occlusion plethysmography. Results There were no significant changes on any of the central or peripheral haemodynamic measures after either oral or direct arterial administration of ALA. Plasma ALA was detected after oral supplementation (95% confidence intervals 463, 761 ng ml(-1)), but did not alter cellular or plasma measures of oxidative stress. Conclusions Neither oral nor intra-arterial ALA had any effect on regional and systemic haemodynamics or measures of oxidative stress in healthy men.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Brachial artery reactivity (BAR), carotid intima-media thickness (IMT), and applanation tonometry for evaluation of total arterial compliance may provide information about preclinical vascular disease. We sought to determine whether these tests could be used to identify patients with coronary artery disease (CAD) without being influenced by their ability to identify those at risk ford CAD developing. Methods: We studied 100 patients and compared 3 groups: 35 patients with known CAD; 34 patients with symptoms and risk factors but no CAD identified by stress echocardiography (risk group); and 31 control subjects. BAR and IMT were measured using standard methods, and total arterial compliance was calculated by the pulse-pressure method from simultaneous radial applanation tonometry and pulsed wave Doppler of the left ventricular outflow. Ischemia was identified as a new or worsening wall-motion abnormality induced by stress. Results: In a comparison between the control subjects and patients either at risk for developing CAD or with CAD, the predictors of risk for CAD were: age (P = .01); smoking history (P = .002); hypercholesterolemia (P = .002); and hypertension (P = .004) (model R = 0.82; P = .0001). The independent predictors of CAD were: IMT (P = .001); BAR (P = .04); sex (P = .005); and hypertension (P = .005) (model R = 0.80; P = .0001). Conclusion: IMT, BAR, and traditional cardiovascular risk factors appear to identify patients at risk for CAD developing. However, only IMT was significantly different between patients at risk for developing CAD and those with overt CAD.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We analyze the critical quantum fluctuations in a coherently driven planar optical parametric oscillator. We show that the presence of transverse modes combined with quantum fluctuations changes the behavior of the quantum image critical point. This zero-temperature nonequilibrium quantum system has the same universality class as a finite-temperature magnetic Lifshitz transition.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Spastic (spa), spasmodic (spd), and oscillator (ot) mice have naturally occurring glycine receptor ( GlyR) mutations, which manifest as motor deficits and an exaggerated startle response. Using whole-cell recording in hypoglossal motoneurons, we compared the physiological mechanisms by which each mutation alters GlyR function. Mean glycinergic miniature IPSC ( mIPSC) amplitude and frequency were dramatically reduced (> 50%) compared with controls for each mutant. mIPSC decay times were unchanged in spa/spa (4.5 +/- 0.3 vs 4.7 +/- 0.2 ms), reduced in spd/spd (2.7 +/- 0.2 vs 4.7 +/- 0.2 ms), and increased in ot/ot (12.3 +/- 1.2 vs 4.8 +/- 0.2 ms). Thus, in spastic, GlyRs are functionally normal but reduced in number, whereas in spasmodic, GlyR kinetics is faster. The oscillator mutation results in complete absence of alpha 1-containing GlyRs; however, some non-alpha 1-containing GlyRs persist at synapses. Fluctuation analysis of membrane current, induced by glycine application to outside-out patches, showed that mean single-channel conductance was increased in spa/spa (64.2 +/- 4.9 vs 36.1 +/- 1.4 pS), but unchanged in spd/spd (32.4 +/- 2.1 vs 35.3 +/- 2.1 pS). GlyR-mediated whole-cell currents in spa/spa exhibited increased picrotoxin sensitivity (27 vs 71% block for 100 mu M), indicating alpha 1 homomeric GlyR expression. The picrotoxin sensitivity of evoked glycinergic IPSCs and conductance of synaptic GlyRs, as determined by nonstationary variance analysis, were identical for spa/spa and controls. Together, these findings show the three mutations disrupt GlyR-mediated inhibition via different physiological mechanisms, and the spastic mutation results in compensatory alpha 1 homomeric GlyRs at extrasynaptic loci.