996 resultados para fluxo de ar


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The sampling of volatile organic compounds using solid phase microextraction is reviewed and its principles are described. The development and application of solid phase microextraction in the sampling of VOCs are presented and discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Essential aspects for characterization of a flow-based analytical procedure or system are discussed in order to permit the composition of a checklist that will lead to a protocol for reporting results and systems in flow analysis. Aspects more related to chromatographic procedures are not considered. The intent is to present normalized proposals in the field of flow analysis for practitioners and developers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple flow injection procedure was developed for determining dipyrone (1-phenyl-2,3-dimethyl-4-methylaminomethano-5-pyrazolone sodium, metamizol, analgin) in pharmaceutical formulations. The determination is based on the reduction of Ag+ ions to Ag0 by dipyrone. A colloidal suspension of Ag0 produced was transported by carrier solution (0.01 mol L-1 NaOH) and turbidimetrically detected at 425 nm. The analytical curve for dipyrone was linear in the range from 5.0 x 10-4 to 2.5 x 10-3 mol L-1 with a correlation coefficient of 0.9990. The detection limit was 1.3 x 10-4 mol L-1 (3sigmaB/slope). The relative standard deviation for ten successive measurements was 1.8% and an analytical frequency of 45 h-1 was obtained. The recovery values from three samples ranged from 96.0 to 102%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An indirect flow injection spectrophotometric procedure is proposed for the determination of N-acetyl-L-cysteine in pharmaceutical formulations. In this system, ferroin ([Fe(II)-(fen)2]2+) in excess, with a strong absorption at 500 nm, is oxidized by cerium(IV) yielding cerium(III) and [Fe(III)-(fen)2]3+ (colorless), thus producing a baseline. When N-acetyl-L-cysteine solution is introduced into the flow injection system, it reacts with cerium(IV) increasing the analytical signal in proportion to the drug concentration. Under optimal experimental conditions, the linearity of the analytical curve for N-acetyl-L-cysteine ranged from 6.5x10-6 to 1.3x10-4 mol L-1. The detection limit was 5.0x10-6 mol L-1and recoveries between 98.0 and 106% were obtained. The sampling frequency was 60 determinations per hour and the RSD was smaller than 1.4% for 2.2x10-5 mol L-1 N-acetyl-L-cysteine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Gaseous mercury sampling conditions were optimized and a dynamic flux chamber was used to measure the air/surface exchange of mercury in some areas of the Negro river basin with different vegetal coverings. At the two forest sites (flooding and non-flooding), low mercury fluxes were observed: maximum of 3 pmol m-2 h-1 - day and minimum of -1 pmol m-2 h-1 - night. At the deforested site, the mercury fluxes were higher and always positive: maximum of 26 pmol m-2 h-1 - day and 17 pmol m-2 h-1 - night. Our results showed that deforestation could be responsible for significantly increasing soil Hg emissions, mainly because of the high soil temperatures reached at deforested sites.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Leaves of Lippia alba were submitted to six different drying treatments, using air at ambient temperature and heated up to 80 °C. The essential oil was extracted by steam distillation and analyzed by GC-MS. For the dried leaves, the oil content was reduced by 12 to 17% when compared with the fresh plant (0.66%). The major oil component was citral, representing 76% for the fresh plant, and varying from 82 to 84% for the dried material. These results showed that L. alba can be submitted to a drying process of up to 80 ºC without degradation and/or loss of the major, [LC1] active component.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A flow injection turbidimetric procedure exploiting merging zones is proposed for determining homatropine methylbromide (HMB) in pharmaceutical preparations. The determination is based on the precipitation reaction of homatropine methylbromide with AgNO3 solution to form a precipitate, which was measured at 410 nm. The analytical curve was linear in the HMB concentration range from 8.0x10-4 to 1.7x10-3 mol L-1, with a detection limit of 9.5x10-5 mol L-1. The recoveries ranged from 94.9 to 104 %, the sampling frequency was 75 h-1 and relative standard deviations were smaller than 2.0 % for solutions containing 1.2x10-3 and 1.5x10-3 mol L-1 HMB (n=10). The results obtained for commercial formulations using the FIA procedure were in good agreement with those obtained by using a comparative method (r= 0.9983).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Manipulation of the flux of substrates was utilized to control the amount of 3-hydroxyvalerate and 3-hydroxy-4-pentenoate produced by Burkohlderia sp. The 3HV production rate was directly proportional to the propionic acid uptake rate with the last one completely directed to 3HV biosynthesis. The 3HPE production rate was inversely proportional to the sucrose uptake rate probably due to operation of the glyoxylate cycle.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The adsorption of Cu(II) ions from aqueous solution by chitosan using a column in a closed hydrodynamic flow system is described. The adsorption capacities as a function of contact time of copper(II) ions and chitosan were determined by varying the ionic strength, temperature and the flow of the metal solution. The Langmuir model reproduced the adsorption isothermal data better than the Freundlich model. The experimental kinetic data correlate properly with the second-order kinetic reaction for the whole set of experimental adsorption conditions. The rate constants exercise great influence on the time taken for equilibrium to be established by complexation or electrostatic interaction between the amino groups of chitosan and the metal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work presents a new approach to control the flow rate in hydrodynamic flow experiments. The combination of air pressure generated by an aquarium air pump and the pressure generated by a water column were used for this purpose. This device supports a stable flow rate without pulsation for a long period of time. Furthermore, the flow rate can be easily controlled at various values in one or more streams. The performance of this approach was investigated using Fe(CN)6(4-) solutions in flowing systems using amperometric and voltammetric detection in wall-jet configuration. The results showed that the performance of the proposed device was better than a commercial peristaltic pump. It suggests that this approach can be used successfully in flow analysis systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An air quality evaluation of indoor environments with focus on lower carbonyls was carried out in 50 public places using TO-11A methodology. Formaldehyde levels (ranging from 12.5 to 1034 mg m-3) were above the threshold limit in 49 of 50 analyzed samples while acetaldehyde (ranging from 5.2 to 840 mg m-3) and acetone (ranging from 5.5 to 4839 mg m-3) were respectively bellow the limits of OSHA and NIOSH in all samples. However all samples were bellow the threshold limits suggested by the Brazilian legislation - NR-15. A correlation study between the carbonyls and temperature and humidity was also done.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple and low-cost flow cell with 30 cm optical path for spectrophotometric measurements is described. It presents desirable characteristics such as low attenuation of the radiation beam and internal volume (75 µL) comparable to that of a 1-cm conventional cell (80 µL). Despite the increase in optical path, the effect on sample dispersion was also similar to that attained in the commercial cell. The performance of the cell was assessed by the determination of phosphate based on the molybdenum blue method, yielding a linear response range between 0.05 and 0.8 mg L-1 phosphorus (r=0.999). The increase in sensitivity (30.4-fold) in comparison with that obtained with a conventional 1-cm flow cell agreed with that estimated by the Lambert-Beer law.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In Surface water concentrations of N2O were measured at 37 stations in Guanabara Bay and fluxes estimated across the air-sea interface. Concentrations averaged 8.2 ± 2.2 nmol L-1 and 90% of the stations showed supersaturation averaging 33%. N2O fluxes were estimated using a two-film model which is given by the product of the concentration difference across the film and the gas transfer coefficient (k w). Two parametrizations of k w were used which provided average fluxes of 0.3 and 3.0 µg N m-2 h-1. Flux measurements using floating chambers (not reported here) seem to agree with the upper limit of these estimates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The first computational implementation that automates the procedures involved in the calculation of infrared intensities using the charge-charge flux-dipole flux model is presented. The atomic charges and dipoles from the Quantum Theory of Atoms in Molecules (QTAIM) model was programmed for Morphy98, Gaussian98 and Gaussian03 programs outputs, but for the ChelpG parameters only the Gaussian programs are supported. Results of illustrative but new calculations for the water, ammonia and methane molecules at the MP2/6-311++G(3d,3p) theoretical level, using the ChelpG and QTAIM/Morphy charges and dipoles are presented. These results showed excellent agreement with analytical results obtained directly at the MP2/6-311++G(3d,3p) level of theory.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Foliar analysis of biochemical parameters were carried out in order to investigate the influence of air pollutants on two tropical tree species (Licania tomentosa (Benth.) and Bauhinia forfícata (Link.)). Special attention was given to tropospheric ozone due to the fact that concentration levels in the region were found to be up to 140 µg m-3 for a 4 h average time, which is well above the value that can cause injuries to orchides and tobacco (59 µg m-3). Other pollutants such as nitrogen and sulphur oxides were measured and their ambient concentrations were also associated to biochemical alterations in the investigated species.