898 resultados para chamber measurements
Resumo:
A Czerny Mount double monochromator is used to measure Raman scattered radiation near 90" from a crystalline, Silicon sample. Incident light is provided by a mixed gas Kr-Ar laser, operating at 5145 A. The double monochromator is calibrated to true wavelength by comparison of Kr and Ar emission Une positions (A) to grating position (A) display [1]. The relationship was found to be hnear and can be described by, y = 1.219873a; - 1209.32, (1) where y is true wavelength (A) and xis grating position display (A). The Raman emission spectra are collected via C"*""*" encoded software, which displays a mV signal from a Photodetector and allows stepping control of the gratings via an A/D interface. [2] The software collection parameters, detector temperature and optics are optimised to yield the best quality spectra. The inclusion of a cryostat allows for temperatmre dependent capabihty ranging from 4 K to w 350 K. Silicon Stokes temperatm-e dependent Raman spectra, generally show agreement with Uterature results [3] in their frequency haxdening, FWHM reduction and intensity increase as temperature is reduced. Tests reveal that a re-alignment of the double monochromator is necessary before spectral resolution can approach literature standard. This has not yet been carried out due to time constraints.
Resumo:
A system comprised of a Martin-Puplett type polarizing interferometer and a Helium-3 cryostat was developed to study the transmission of materials in the very-far-infrared region of the spectrum. This region is of significant interest due to the low-energy excitations which many materials exhibit. The experimental transmission spectrum contains information concerning the optical properties of the material. The set-up of this system is described in detail along with the adaptations and improvements which have been made to the system to ensure the best results. Transmission experiments carried out with this new set-up for two different varieties of materials: superconducting thin films of lead and biological proteins, are discussed. Several thin films of lead deposited on fused silica quartz substrates were studied. From the ratio of the transmission in the superconducting state to that in the normal state the superconducting energy gap was determined to be approximately 25 cm-1 which corresponds to 2~/kBTc rv 5 in agreement with literature data. Furthermore, in agreement with theoretical predictions, the maximum in the transmission ratio was observed to increase as the film thickness was increased. These results provide verification of the system's ability to accurately measure the optical properties of thin low-Tc superconducting films. Transmission measurements were carried out on double deionized water, and a variety of different concentrations by weight of the globular protein, Bovine Serum Albumin, in the sol, gel and crystalline forms. The results of the water study agree well with literature values and thus further illustrate the reproducibility of the system. The results of the protein experiments, although preliminary, indicate that as the concentration increases the samples become more transparent. Some weak structure in the frequency dependent absorption coefficient, which is more prominent in crystalline samples, may be due to low frequency vibrations of the protein molecules.
Resumo:
Several recent studies have described the period of impaired alertness and performance known as sleep inertia that occurs upon awakening from a full night of sleep. They report that sleep inertia dissipates in a saturating exponential manner, the exact time course being task dependent, but generally persisting for one to two hours. A number of factors, including sleep architecture, sleep depth and circadian variables are also thought to affect the duration and intensity. The present study sought to replicate their findings for subjective alertness and reaction time and also to examine electrophysiological changes through the use of event-related potentials (ERPs). Secondly, several sleep parameters were examined for potential effects on the initial intensity of sleep inertia. Ten participants spent two consecutive nights and subsequent mornings in the sleep lab. Sleep architecture was recorded for a fiiU nocturnal episode of sleep based on participants' habitual sleep patterns. Subjective alertness and performance was measured for a 90-minute period after awakening. Alertness was measured every five minutes using the Stanford Sleepiness Scale (SSS) and a visual analogue scale (VAS) of sleepiness. An auditory tone also served as the target stimulus for an oddball task designed to examine the NlOO and P300 components ofthe ERP waveform. The five-minute oddball task was presented at 15-minute intervals over the initial 90-minutes after awakening to obtain six measures of average RT and amplitude and latency for NlOO and P300. Standard polysomnographic recording were used to obtain digital EEG and describe the night of sleep. Power spectral analyses (FFT) were used to calculate slow wave activity (SWA) as a measure of sleep depth for the whole night, 90-minutes before awakening and five minutes before awakening.
Resumo:
The major focus of this dissertation was to explain terroir effects that impact wine varietal character and to elucidate potential determinants of terroir by testing vine water status (VWS) as the major factor of the terroir effect. It was hypothesized that consistent water status zones could be identified within vineyard sites, and, that differences in vine performance, fruit composition and wine sensory attributes could be related to VWS. To test this hypothesis, ten commercial Riesling vineyards representative of each Vintners Quality Alliance sub-appellation were selected. Vineyards were delineated using global positioning systems and 75 to 80 sentinel vines per vineyard were geo-referenced for data collection. During the 2005 to 2007 growing seasons, VWS measurements [midday leaf water potential ('l')] were collected from a subset of these sentinel vines. Data were collected on soil texture and composition, soil moisture, vine performance (yield components, vine size) and fruit composition. These variables were mapped using global information system (GIS) software and relationships between them were elucidated. Vines were categorized into "low" and "high" water status regions within each vineyard block and replicate wines were made from each. Many geospatial patterns and relationships were spatially and temporally stable within vineyards. Leaf'l' was temporally stable within vineyards despite different weather conditions during each growing season. Generally, spatial relationships between 'l', soil moisture, vine size, berry weight and yield were stable from year to year. Leaf", impacted fruit composition in several vineyards. Through sorting tasks and multidimensional scaling, wines of similar VWS had similar sensory properties. Descriptive analysis further indicated that VWS impacted wine sensory profiles, with similar attributes being different for wines from different water status zones. Vineyard designation had an effect on wine profiles, with certain sensory and chemical attributes being associated from different subappellations. However, wines were generally grouped in terms of their regional designation ('Lakeshore', 'Bench', 'Plains') within the Niagara Peninsula. Through multivariate analyses, specific sensory attributes, viticulture and chemical variables were associated with wines of different VWS. Vine water status was a major contributor to the terroir effect, as it had a major impact on vine size, berry weight and wine sensory characteristics.
Resumo:
The interior layered deposit (ILD) in Ganges Chasma, Valles Marineris, is a 4.25 km high mound that extends approximately 110 km from west to east. The deposition, deformation, and erosion history of the Ganges ILD records aids in identifying the processes that formed and shaped the Chasma. To interpret structural and geomorphic processes acting on the ILD, multiple layer attitudes and layer thickness transects were conducted on the Ganges ILD. Mineralogical data was analyzed to determine correlations between materials and landforms. Layer thickness measurements indicate that the majority of layers are between 0.5 m and 4 m throughout the ILD. Three major benches dominate the Ganges ILD. Layer thicknesses increase at the ILD benches, suggesting that the benches are formed from the gradual thickening of layers. This indicates that the benches are depositional features draping over basement topography. Layer attitudes indicate overall shallow dips generally confined to a North-South direction that locally appear to follow bench topography. Layering is disrupted on a scale of 40 m to 150 m in 12 separate locations throughout the ILD. In all locations, underlying layering is disturbed by overlying folded layers in a trough-like geometry. These features are interpreted to have formed as submarine channels in a lacustrine setting, subsequently infilled by sediments. Subsequently, the channels were eroded to the present topography, resulting in the thin, curved layering observed. Data cannot conclusively support one ILD formation hypothesis, but does indicate that the Ganges ILD postdates Chasma formation. The presence of water altered minerals, consistently thin layering, and layer orientations provide strong evidence that the ILD formed in a lacustrine setting.
Resumo:
The book is hardcover and inscribed with an illegible signature, dated 1880 and below that is the signature Margaret J. Woodruff. The preface of the book begins, "The present work is designed to fulfil an important purpose in Education - that of bringing clearly into view the leading facts which are supposed to be gained through a long course of instruction. Without proposing to supersede the elementary books usually employed, it offers a certain test of what is presumed to have been previously learned. With such a work in their hands, Schoolmasters, Tutors, Governesses, or Parents, may at once satisfy themselves as to the degree of knowledge on a variety of subjects attained by the young person under their charge, and for whose intellectual culture they feel a special interest." The full text is available in the Brock University Special Collections and Archives.
Resumo:
The St. Catharines and District Chamber of Commerce merged with the Thorold Chamber of Commerce in 2006. In 2012, they joined a region wide Chamber, becoming part of the Greater Niagara Chamber of Commerce. The Chamber is a "is a non-partisan, non-sectarian association of businesses, groups and individuals who support business growth and effective government fostering a sustainable and vibrant Niagara."
Resumo:
Engineer estimate (5 ½ pages, handwritten) in the marsh lands drainage presented to the Chamber and Councilors of the County of Welland in council assembled. This report is signed by S.D. Woodruff, June 20, 1857.
Resumo:
Map of measurements of lot no.186, Dec. 19, 1855.
Resumo:
Map of measurements of lots no.185 and 186 by George Strohan, Dec. 29, 1855.
Resumo:
Durant la dernière décennie, les développements technologiques en radiothérapie ont transformé considérablement les techniques de traitement. Les nouveaux faisceaux non standard améliorent la conformité de la dose aux volumes cibles, mais également complexifient les procédures dosimétriques. Puisque des études récentes ont démontré l’invalidité de ces protocoles actuels avec les faisceaux non standard, un nouveau protocole applicable à la dosimétrie de référence de ces faisceaux est en préparation par l’IAEA-AAPM. Le but premier de cette étude est de caractériser les facteurs responsables des corrections non unitaires en dosimétrie des faisceaux non standard, et ainsi fournir des solutions conceptuelles afin de minimiser l’ordre de grandeur des corrections proposées dans le nouveau formalisme de l’IAEA-AAPM. Le deuxième but de l’étude est de construire des méthodes servant à estimer les incertitudes d’une manière exacte en dosimétrie non standard, et d’évaluer les niveaux d’incertitudes réalistes pouvant être obtenus dans des situations cliniques. Les résultats de l’étude démontrent que de rapporter la dose au volume sensible de la chambre remplie d’eau réduit la correction d’environ la moitié sous de hauts gradients de dose. Une relation théorique entre le facteur de correction de champs non standard idéaux et le facteur de gradient du champ de référence est obtenue. En dosimétrie par film radiochromique, des niveaux d’incertitude de l’ordre de 0.3% sont obtenus par l’application d’une procédure stricte, ce qui démontre un intérêt potentiel pour les mesures de faisceaux non standard. Les résultats suggèrent également que les incertitudes expérimentales des faisceaux non standard doivent être considérées sérieusement, que ce soit durant les procédures quotidiennes de vérification ou durant les procédures de calibration. De plus, ces incertitudes pourraient être un facteur limitatif dans la nouvelle génération de protocoles.
Resumo:
Thèse numérisée par la Division de la gestion de documents et des archives de l'Université de Montréal.
Resumo:
Study Design. Reliability study. Objectives. To assess between-acquisition reliability of new multilevel trunk cross sections measurements, in order to define what is a real change when comparing 2 trunk surface acquisitions of a same patient, before and after surgery or throughout the clinical monitoring. Summary of Background Data. Several cross-sectional surface measurements have been proposed in the literature for noninvasive assessment of trunk deformity in patients with adolescent idiopathic scoliosis (AIS). However, only the maximum values along the trunk are evaluated and used for monitoring progression and assessing treatment outcome. Methods. Back surface rotation (BSR), trunk rotation (TR), and coronal and sagittal trunk deviation are computed on 300 cross sections of the trunk. Each set of 300 measures is represented as a single functional data, using a set of basis functions. To evaluate between-acquisition variability at all trunk levels, a test-retest reliability study is conducted on 35 patients with AIS. A functional correlation analysis is also carried out to evaluate any redundancy between the measurements. Results. Each set of 300 measures was successfully described using only 10 basis functions. The test-retest reliability of the functional measurements is good to very good all over the trunk, except above the shoulders level. The typical errors of measurement are between 1.20° and 2.2° for the rotational measures and between 2 and 6 mm for deviation measures. There is a very strong correlation between BSR and TR all over the trunk, a moderate correlation between coronal trunk deviation and both BSR and TR, and no correlation between sagittal trunk deviation and any other measurement. Conclusion. This novel representation of trunk surface measurements allows for a global assessment of trunk surface deformity. Multilevel trunk measurements provide a broader perspective of the trunk deformity and allow a reliable multilevel monitoring during clinical follow-up of patients with AIS and a reliable assessment of the esthetic outcome after surgery.
Resumo:
Study Design Retrospective study of surgical outcome. Objectives To evaluate quantitatively the changes in trunk surface deformities after scoliosis spinal surgery in Lenke 1A adolescent idiopathic scoliosis (AIS) patients and to compare it with changes in spinal measurements. Summary of Background Data Most studies documenting scoliosis surgical outcome used either radiographs to evaluate changes in the spinal curve or questionnaires to assess patients health-related quality of life. Because improving trunk appearance is a major reason for patients and their parents to seek treatment, this study focuses on postoperative changes in trunk surface deformities. Recently, a novel approach to quantify trunk deformities in a reliable, automatic, and noninvasive way has been proposed. Methods Forty-nine adolescents with Lenke 1A idiopathic scoliosis treated surgically were included. The back surface rotation and trunk lateral shift were computed on trunk surface acquisitions before and at least 6 months after surgery. We analyzed the effect of age, height, weight, curve severity, and flexibility before surgery, length of follow-up, and the surgical technique. For 25 patients with available three-dimensional (3D) spinal reconstructions, we compared changes in trunk deformities with changes in two-dimensional (2D) and 3D spinal measurements. Results The mean correction rates for the back surface rotation and the trunk lateral shift are 18% and 50%, respectively. Only the surgical technique had a significant effect on the correction rate of the back surface rotation. Direct vertebral derotation and reduction by spine translation provide a better correction of the rib hump (22% and 31% respectively) than the classic rod rotation technique (8%). The reductions of the lumbar Cobb angle and the apical vertebrae transverse rotation explain, respectively, up to 17% and 16% the reduction of the back surface rotation. Conclusions Current surgical techniques perform well in realigning the trunk; however, the correction of the deformity in the transverse plane proves to be more challenging. More analysis on the positive effect of vertebral derotation on the rib hump correction is needed. Level of evidence III.
Resumo:
The design, erection and evalution procedures for it microwave anechuic chamber competed at Cochin University for antenna studies are presented the chamber has an average reflectivity level of - 32 dB on at X-band frequencies, and it i, comparable to international standards.