985 resultados para carotid atherosclerosis


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES To assess the literature on carotid calcifications defined from panoramic radiographs (PMX) and concurrent diagnosis of stroke and periodontitis. MATERIALS AND METHODS A literature search screening for publications using search terms such as PMX and carotid calcification, stroke and periodontitis was performed in November 2012. RESULTS A total of 189 articles were retrieved, among which 30 were included in the review. The sensitivity for PMX findings of carotid calcifications (CC) compared to a diagnosis by Doppler sonography varied between 31.1-100%. The specificity for PMX findings of carotid calcifications compared to a diagnosis by Doppler sonography varied between 21.4-87.5%. Individuals with CC findings from PMX have more periodontitis and risk for stroke. CONCLUSIONS There is a shortage of well-designed studies in older dentate individuals assessing the associations between periodontitis and radiographic evidence of CC and in relation to stroke or other cardiovascular diseases. STATEMENT OF CLINICAL RELEVANCE: Carotid calcifications are prevalent in patients with periodontitis and such individuals may have an increased risk for stroke. The absence of signs of carotid calcification on panoramic radiographs is indicative of no calcification of carotid arteries.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report on the molecular characterization of a microdeletion of approximately 2.5 Mb at 2p11.2 in a female baby with left congenital aural atresia, microtia, and ipsilateral internal carotid artery agenesis. The deletion was characterized by fluorescence in situ hybridization, array comparative genomic hybridization, and whole genome re-sequencing. Among the genes present in the deleted region, we focused our attention on the FOXI3 gene. Foxi3 is a member of the Foxi class of Forkhead transcription factors. In mouse, chicken and zebrafish Foxi3 homologues are expressed in the ectoderm and endoderm giving rise to elements of the jaw as well as external, middle and inner ear. Homozygous Foxi3-/- mice have recently been generated and show a complete absence of the inner, middle, and external ears as well as severe defects in the jaw and palate. Recently, a 7-bp duplication within exon 1 of FOXI3 that produces a frameshift and a premature stop codon was found in hairless dogs. Mild malformations of the outer auditory canal (closed ear canal) and ear lobe have also been noted in a fraction of FOXI3 heterozygote Peruvian hairless dogs. Based on the phenotypes of Foxi3 mutant animals, we propose that FOXI3 may be responsible for the phenotypic features of our patient. Further characterization of the genomic region and the analysis of similar patients may help to demonstrate this point. © 2015 Wiley Periodicals, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Barostim neo ™ system is a novel implantable device that activates the carotid baroreflex. It decreases the sympathetic activity and inhibits the renin system, which results in reduced blood pressure and heart rate. In patients with resistant hypertension, electrically activation of the baroreflex leads to an average decrease in systolic blood pressure of 38, 36, 40 and 53 mmHg at 1, 2, 3 and 4 years, respectively. Additionally, cardiac remodelling with reduced left ventricular mass and posterior wall thickness has been observed in long-term studies. In a limited number of patients with heart failure, baroreflex activation therapy leads to a decrease in muscle sympathetic nerve activity and to improved quality of life and functional capacities. The implantation procedure is safe and associated with risks comparable with those of other active implantable devices. Barostim neo is currently available in several European countries.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE To compare postoperative morphological and rheological conditions after eversion carotid endarterectomy versus conventional carotid endarterectomy using computational fluid dynamics. BASIC METHODS Hemodynamic metrics (velocity, wall shear stress, time-averaged wall shear stress and temporal gradient wall shear stress) in the carotid arteries were simulated in one patient after conventional carotid endarterectomy and one patient after eversion carotid endarterectomy by computational fluid dynamics analysis based on patient specific data. PRINCIPAL FINDINGS Systolic peak of the eversion carotid endarterectomy model showed a gradually decreased pressure along the stream path, the conventional carotid endarterectomy model revealed high pressure (about 180 Pa) at the carotid bulb. Regions of low wall shear stress in the conventional carotid endarterectomy model were much larger than that in the eversion carotid endarterectomy model and with lower time-averaged wall shear stress values (conventional carotid endarterectomy: 0.03-5.46 Pa vs. eversion carotid endarterectomy: 0.12-5.22 Pa). CONCLUSIONS Computational fluid dynamics after conventional carotid endarterectomy and eversion carotid endarterectomy disclosed differences in hemodynamic patterns. Larger studies are necessary to assess whether these differences are consistent and might explain different rates of restenosis in both techniques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE The aim of this study was to compare the diagnostic accuracy of 3D time-of-flight (TOF-MRA) and contrast-enhanced (CE-MRA) magnetic resonance angiography at 3 T for detection and quantification of proximal high-grade stenosis using multidetector computed tomography angiography (MDCTA) as reference standard. METHODS The institutional ethics committee approved this prospective study. A total of 41 patients suspected of having internal carotid artery (ICA) stenosis underwent both MDCTA and MRA. CE-MRA and TOF-MRA were performed using a 3.0-T imager with a dedicated eight-element cervical coil. ICA stenoses were measured according to the North American Symptomatic Carotid Endarterectomy Trial criteria and categorized as 0-25 % (minimal), 25-50 % (mild), 50-69 % (moderate), 70-99 % (high grade), and 100 % (occlusion). Sensitivity and specificity for the detection of high-grade ICA stenoses (70-99 %) and ICA occlusions were determined. In addition, intermodality agreement was assessed with κ-statistics for detection of high-grade ICA stenoses (70-99 %) and ICA occlusions. RESULTS A total of 80 carotid arteries of 41 patients were reviewed. Two previously stented ICAs were excluded from analysis. On MDCTA, 7 ICAs were occluded, 12 ICAs presented with and 63 without a high-grade ICA stenosis (70-99 %). For detecting 70-99 % stenosis, both 3D TOF-MRA and CE-MRA were 91.7 % sensitive and 98.5 % specific, respectively. Both MRA techniques were highly sensitive (100 %), and specific (CE-MRA, 100 %; TOF-MRA, 98.7 %) for the detection of ICA occlusion. However, TOF-MRA misclassified one high-grade stenosis as occlusion. Intermodality agreement for detection of 70-99 % ICA stenoses was excellent between TOF-MRA and CE-MRA [κ = 0.902, 95 % confidence interval (CI) = 0.769-1.000], TOF-MRA and MDCTA (κ = 0.902, 95 % CI = 0.769-1.000), and CE-MRA and MDCTA (κ = 0.902, 95 % CI = 0.769-1.000). CONCLUSION Both 3D TOF-MRA and CE-MRA at 3 T are reliable tools for detecting high-grade proximal ICA stenoses (70-99 %). 3D TOF-MRA might misclassify pseudo-occlusions as complete occlusions. If there are no contraindications for CE-MRA, CE-MRA is recommended as primary MR imaging modality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Biomarkers are a promising tool for the management of patients with atherosclerosis, but their variation is largely unknown. We assessed within-subject and between-subject biological variation of biomarkers in peripheral artery disease (PAD) patients and healthy controls, and defined which biomarkers have a favorable variation profile for future studies. METHODS Prospective, parallel-group cohort study, including 62 patients with stable PAD (79% men, 65±7years) and 18 healthy control subjects (44% men, 57±7years). Blood samples were taken at baseline, and after 3-, 6-, and 12-months. We calculated within-subject (CVI) and between-subject (CVG) coefficients of variation and intra-class correlation coefficient (ICC). RESULTS Mean levels of D-dimer, hs-CRP, IL-6, IL-8, MMP-9, MMP-3, S100A8/A9, PAI-1, sICAM-1, and sP-selectin levels were higher in PAD patients than in healthy controls (P≤.05 for all). CVI and CVG of the different biomarkers varied considerably in both groups. An ICC≥0.5 (indicating moderate-to-good reliability) was found for hs-CRP, D-Dimer, E-selectin, IL-10, MCP-1, MMP-3, oxLDL, sICAM-1 and sP-selectin in both groups, for sVCAM in healthy controls and for MMP-9, PAI-1 and sCD40L in PAD patients. CONCLUSIONS Single biomarker measurements are of limited utility due to large within-subject variation, both in PAD patients and healthy subjects. D-dimer, hs-CRP, MMP-9, MMP-3, PAI-1, sP-selectin and sICAM-1 are biomarkers with both higher mean levels in PAD patients and a favorable variation profile making them most suitable for future studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE Currently one of the most widely used models for the development of endovascular techniques and coiling devices for treatment of aneurysm is the elastase-induced aneurysm model in the rabbit carotid artery. Microsurgical techniques for creating an aneurysm with a venous pouch have also been established, although both techniques usually result in aneurysms less than 1 cm in diameter. We investigated whether an increase in blood flow toward the neck would produce larger aneurysms in a microsurgical venous pouch model. MATERIALS AND METHODS Microsurgical operations were performed on 11 New Zealand white rabbits. Both carotid arteries and the right jugular vein were dissected, and the right carotid artery was temporarily clipped followed by an arteriotomy. The left carotid artery was also clipped proximally, ligated distally, and sutured onto the proximal half of the arteriotomy in the right carotid artery. The venous graft was sutured onto the distal half of the arteriotomy. Digital subtraction angiography was also performed. RESULTS Angiography showed patent anastomosed vessels and aneurysms in the seven surviving rabbits. Mean aneurysm measurements among surviving rabbits with patent vessels were: 13.9 mm length, 9.3 mm width, and neck diameter 4.7 mm. The resulting mean aspect ratio was 3.35 and the mean bottleneck ratio was 3.05. CONCLUSION A large venous graft and increased blood flow toward the base of the aneurysm seem to be key factors in the creation of large venous pouch aneurysms. These large aneurysms allow testing of endovascular devices designed for large and giant aneurysms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND We prospectively investigated temporal and spatial evolution of intramural hematomas in patients with acute spontaneous internal carotid artery dissection using repeated magnetic resonance imaging over six-months. AIM The aim of the present study was to assess dynamic changes of intramural hematoma in patients with acute spontaneous internal carotid artery dissection at multiple follow-up time-points with T1w, PD/T2w, and magnetic resonance angiography. METHODS We performed serial multiparametric magnetic resonance imaging in 10 patients with spontaneous internal carotid artery dissection on admission, at days 1, 3, 7-14 and at months 1·5, 3, and 6. We calculated the volume and extension of the hyperintense intramural hematoma using T1w and PD/T2w fat suppressed sequences and assessed the degree of stenosis due to the hematoma using magnetic resonance angiography. RESULTS Mean interval from symptom onset to first magnetic resonance imaging was two-days (SD 2·7). Two patients presented with ischemic stroke, three with transient ischemic attacks, and five with pain and local symptoms only. Nine patients had a transient increase of the intramural hematoma volume, mainly up to day 10 after symptom onset. Fifty percent had a transient increase in the degree of the internal carotid artery stenosis on MRA, one resulting in a temporary occlusion. Lesions older than one-week were predominantly characterized by a shift from iso- to hyperintese signal on T2w images. At three-month follow-up, intramural hematoma was no longer detectable in 80% of patients and had completely resolved in all patients after six-months. CONCLUSIONS Spatial and temporal dynamics of intramural hematomas after spontaneous internal carotid artery dissection showed an early volume increase with concomitant progression of the internal carotid artery stenosis in 5 of 10 patients. Although spontaneous internal carotid artery dissection overall carries a good prognosis with spontaneous hematoma resorption in all our patients, early follow-up imaging may be considered, especially in case of new clinical symptoms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Treatment of carotid artery stenosis decreases the long-term risk of stroke and may enhance cerebral blood flow. It is therefore expected to have the potential to prevent cognitive decline or even improve cognition over the long-term. However, intervention itself can cause peri-interventional cerebral infarcts, possibly resulting in a decline of cognitive performance, at least for a short time. We investigated the long-term effects of three treatment methods on cognition and the emotional state one year after intervention. In this prospective observational cohort study, 58 patients with extracranial carotid artery stenosis (≥70%) underwent magnetic resonance imaging and assessment of cognition, mood and motor speed before carotid endarterectomy (n = 20), carotid stenting (n = 10) or best medical treatment (n = 28) (i.e., time-point 1 [TP1]), and at one-year follow-up (TP2). Gain scores, reflecting cognitive change after treatment, were built according to performance as (TP2 -TP1)/TP1. Independent of the treatment type, significant improvement in frontal lobe functions, visual memory and motor speed was found. Performance level, motor speed and mood at TP1 were negatively correlated with gain scores, with greater improvement in patients with low performance before treatment. Active therapy, whether conservative or interventional, produces significant improvement of frontal lobe functions and memory in patients with carotid artery disease, independent of treatment type. This effect was particularly pronounced in patients with low cognitive performance prior to treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Gebiet: Chirurgie Abstract: Introduction: Carotid endarterectomy (CEA) and coronary artery bypass grafting (CABG) could be approached in a combined or a staged fashion. Some crucial studies have shown no significant difference in peri-operative stroke and death rate in combined versus staged CEA/CABG. At present conventional extracorporeal circulation (CECC) is regarded as the gold standard for performing on-pump coronary artery bypass grafting. On contrary, the use of minimized extracorporeal circulation (MECC) for CABG diminishes hemodilution, blood-air contact, foreign surface contact and inflammatory response. At the same time, general anaesthesia (GA) is a potential risk factor for higher perioperative stroke rate after isolated CEA, not only for the ipsilateral but also for the contralateral side especially in case of contralateral high-grade stenosis or occlusion. The aim of the study was to analyze if synchronous CEA/CABG using MECC (CEA/CABG group) allows reducing the perioperative stroke risk to the level of isolated CEA performed under GA (CEA-GA group). – Methods: A retrospective analysis of all patients who underwent CEA at our institution between January 2005 and December 2012 was performed. We compared outcomes between all patients undergoing CEA/CABG to all isolated CEA-GA during the same time period. The CEA/CABG group was additionally compared to a reference group consisting of patients undergoing isolated CEA in local anaesthesia. Primary outcome was in-hospital stroke. – Results: A total of 367 CEAs were performed, from which 46 patients were excluded having either off-pump CABG or other cardiac surgery procedures than CABG combined with CEA. Out of 321 patients, 74 were in the CEA/CABG and 64 in the CEA-GA group. There was a significantly higher rate of symptomatic stenoses among patients in the CEA-GA group (p<0.002). Three (4.1%) strokes in the CEA/CABG group were registered, two ipsilateral (2.7%) and one contralateral (1.4%) to the operated side. In the CEA-GA group 2 ipsilateral strokes (3.1%) occurred. No difference was noticed between the groups (p=1.000). One patient with stroke in each group had a symptomatic stenosis preoperatively. – Conclusions: Outcome with regard to mortality and neurologic injury is very good in both -patients undergoing CEA alone as well as patients undergoing synchronous CEA and CABG using the MECC system. Although the CEA/CABG group showed slightly increased risk of stroke, it can be considered as combined treatment in particular clinical situations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

While coronary atherosclerosis is a leading cause of mortality, evaluation of coronary lesions was previously limited to either indirect angiographic assessment of the lumen silhouette or post mortem investigations. Intracoronary (IC) imaging modalities have been developed that allow for visualization and characterization of coronary atheroma in living patients. Used alone or in combination, these modalities have enhanced our understanding of pathobiological mechanisms of atherosclerosis, identified factors responsible for disease progression, and documented the ability of various medications to reverse the processes of plaque growth and destabilization. These methodologies have established a link between in vivo plaque characteristics and subsequent coronary events, thereby improving individual risk stratification, paving the way for risk-tailored systemic therapies and raising the option for pre-emptive interventions. Moreover, IC imaging is increasingly used during coronary interventions to support therapeutic decision-making in angiographically inconclusive disease, guide and optimize procedural results in selected lesion and patient subsets, and unravel mechanisms underlying stent failure. This review aims to summarize current evidence regarding the role of IC imaging for diagnosis and risk stratification of coronary atherosclerosis, and to describe its clinical role for guiding percutaneous coronary interventions. Future perspectives for in-depth plaque characterization using novel techniques and multimodality imaging approaches are also discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coronary atherosclerosis has been considered a chronic disease characterized by ongoing progression in response to systemic risk factors and local pro-atherogenic stimuli. As our understanding of the pathobiological mechanisms implicated in atherogenesis and plaque progression is evolving, effective treatment strategies have been developed that led to substantial reduction of the clinical manifestations and acute complications of coronary atherosclerotic disease. More recently, intracoronary imaging modalities have enabled detailed in vivo quantification and characterization of coronary atherosclerotic plaque, serial evaluation of atherosclerotic changes over time, and assessment of vascular responses to effective anti-atherosclerotic medications. The use of intracoronary imaging modalities has demonstrated that intensive lipid lowering can halt plaque progression and may even result in regression of coronary atheroma when the highest doses of the most potent statins are used. While current evidence indicates the feasibility of atheroma regression and of reversal of presumed high-risk plaque characteristics in response to intensive anti-atherosclerotic therapies, these changes of plaque size and composition are modest and their clinical implications remain largely elusive. Growing interest has focused on achieving more pronounced regression of coronary plaque using novel anti-atherosclerotic medications, and more importantly on elucidating ways toward clinical translation of favorable changes of plaque anatomy into more favorable clinical outcomes for our patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE The aim of this study was to elucidate the relationship between the echogenicity of carotid artery plaques and the following risk factors: circulating oxLDL, hsCRP, the metabolic syndrome (MetS), and several of the traditional cardiovascular (CV) risk factors. MATERIAL AND METHODS A cross-sectional population-based study of 513 sixty-one-year-old men. The levels of circulating oxLDL were determined in plasma samples by sandwich ELISA utilizing a specific murine monoclonal antibody (mAb-4E6). High-sensitivity CRP was measured in plasma by ELISA. Plaque occurrence, size and echogenicity were evaluated from B-mode ultrasound registrations in the carotid arteries. Plaque echogenicity was assessed based on a four-graded classification scale. RESULTS A higher frequency of echolucent carotid plaques was observed with increasing levels of oxLDL and systolic blood pressure (p = 0.008 and p = 0.041, respectively). Subjects with the MetS had a significantly higher frequency of echogenic plaques than subjects without the MetS (p = 0.009). In a multiple logistic regression analysis, oxLDL turned out to be independently associated with echolucent carotid plaques. CONCLUSIONS The occurrence of echolucent carotid plaques was associated with oxLDL and systolic blood pressure, and oxLDL was associated with echolucent carotid plaques independently of systolic blood pressure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES A dissociation between behavioural (in-control) and physiological parameters (indicating loss-of-control) is associated with cardiovascular risk in defensive coping (DefS) Africans. We evaluated relationships between DefS, sub-clinical atherosclerosis, low-grade inflammation and hypercoagulation in a bi-ethnic sex cohort. METHODS Black (Africans) and white Africans (Caucasians) (n = 375; aged 44.6 ± 9.7 years) were included. Ambulatory BP, vascular structure (left carotid cross-sectional wall area (L-CSWA) and plaque counts), and markers of coagulation and inflammation were quantified. Ethnicity/coping style interaction was revealed only in DefS participants. RESULTS A hypertensive state, less plaque, low-grade inflammation, and hypercoagulation were more prevalent in DefS Africans (27-84%) than DefS Caucasians (18-41%). Regression analyses demonstrated associations between L-CSWA and 24 hour systolic BP (R(2) = 0.38; β = 0.78; p < 0.05) in DefS African men but not in DefS African women or Caucasians. No associations between L-CSWA and coagulation markers were evident. CONCLUSION Novel findings revealed hypercoagulation, low-grade inflammation and hyperkinetic BP (physiological loss-of-control responses) in DefS African men. Coupled to a self-reported in-control DefS behavioural profile, this reflects dissociation between behaviour and physiology. It may explain changes in vascular structure, increasing cerebrovascular disease risk in a state of hyper-vigilant coping.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Carotid atherosclerotic disease is highly related to cerebrovascular events. Carotid endarterectomy is the common operation method to treat this disease. In this study, hemodynamics analyses are performed on the carotid arteries in three patients, whose right carotid artery had been treated by carotid endarterectomy and the left carotid artery remained untreated. Flow and loading conditions are compared between these treated and untreated carotid arteries and evaluation of the operative results is discussed. Patient-specific models are reconstructed from MDCT data. Intraoperative ultrasound flow measurements are performed on the treated carotid arteries and the obtained data are used as the boundary conditions of the models and the validations of the computational results. Finite volume method is employed to solve the transport equations and the flow and loading conditions of the models are reported. The results indicate that: (i) in two of the three patients, the internal-to-external flow rate ratio in the untreated carotid artery is larger than that in the treated one, and the average overall flow split ratio by summing up the data of both the left and right carotid arteries is about 2.15; (ii) in the carotid bulb, high wall shear stress occurs at the bifurcation near the external carotid artery in all of the cases without hard plaques; (iii) the operated arteries present low time-averaged wall shear stress at the carotid bulb, especially for the treated arteries with patch technique, indicating the possibility of the recurrence of stenosis; (iv) high temporal gradient of wall shear stress (>35 Pa/s) is shown in the narrowing regions along the vessels; and (v) in the carotid arteries without serious stenosis, the maximum velocity magnitude during mid-diastole is 32~37% of that at systolic peak, however, in the carotid artery with 50% stenosis by hard plaques, this value is nearly doubled (64%). The computational work quantifies flow and loading distributions in the treated and untreated carotid arteries of the same patient, contributing to evaluation of the operative results and indicating the recurrent sites of potential atheromatous plaques.