900 resultados para boron hydroxide


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Eighty root canals of the premolars of 4 dogs, with vital pulp, were instrumented and filled during the same session with the Sealapex, CRCS, Sealer 26, and Apexit sealers, the animals were sacrificed 180 days after root canal filling and their maxillae and mandibles were removed and fixed in 10% formalin, After routine histologic processing, the sections were stained with hematoxylin-eosin and Mallory trichrome, Histopathologic analysis showed that Sealapex was the sealer that best permitted the deposition of mineralized tissue at the apical level and was the only sealer that provided complete sealing (37.5% of cases), With the use of Sealapex, no inflammatory infiltrate occurred and there was no reabsorption of mineralized tissues, In contrast, partial sealing and a moderate inflammatory infiltrate occurred with the use of CRCS, When Apexit and Sealer 26 were used the absence of sealing was frequent and active reabsorption of mineralized tissues occurred in most cases, the inflammatory infiltrate predominating with the use of Apexit was of the severe type, whereas with the use of Sealer 26 the inflammatory infiltrate was mild or absent.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this work was to evaluate the biological compatibility of the Sealapex, Apexit, Sealer 26 and Ketac Endo endodontic cements. Polyethylene tubes containing these cements were implanted in the subcutaneous tissue of 40 (forty) rats. The animals were sacrificed after 14 and 90 days. A descriptive analysis of the reactions found in the connective tissue by contact with the cements was performed. The magnitude of inflammatory infiltrate, the presence and predominance of cell types and their distribution as to the filling material and reparative phenomena, such as fibroblastic and angioblastic proliferation and formation of fibrous capsules, were subjectively measured. After 90 days, all cements presented statistically significant reduction of the inflammatory reaction, presence of a fibrous tissue capsule in contact with the opening of the tubes containing the filling materials, and reduction of fibroblastic proliferation. Angioblastic proliferation decreased only for the Sealer 26 and Ketac Endo groups. All cements tested were either partially or totally phagocyted, and the mildest inflammatory response was found for the Sealer 26 group at both evaluation periods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In some parts of the world, revascularization may not be the most feasible treatment option for necrotic immature teeth. Therefore, apexification remains the most widely utilized treatment option for these cases. This study aimed to evaluate the fracture resistance of weakened bovine tooth roots treated with various irrigant solutions as well as long-term application of calcium hydroxide intracanal medication (ICM). One hundred seventy bovine teeth were randomly divided into three experimental groups (n = 50) and two control groups (n = 10). Group SS was irrigated with physiologic solution; group CHX was treated with 2% chlorhexidine gel and group NaOCl was irrigated with 1% sodium hypochlorite. After instrumentation, root canals were dressed with calcium hydroxide and evaluated at different periods (15, 60, 90, 180, and 360 days). The specimens were loaded at a 45° angle to measure fracture resistance through the use of an EMIC test machine. A decrease in fracture resistance was observed during the time of ICM dressing. The highest values of fracture resistance were observed in group SS with 15 days of ICM, not differing from the control group. Irrigation with NaOCl associated with ICM for 15 days presented the lowest fracture resistance; however, a statistically significant difference was not observed when compared with SS and CHX in the same time period. In longer periods of exposure to ICM (180 and 360 days), root canals irrigated with NaOCl and CHX showed significantly lower fracture resistance than SS (P < 0.05). Apexification with periodic changes of calcium hydroxide medicament leads to weakness of the teeth independent of the irrigation solution used.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To determine the presence of p-monochlorophenol in the calcium hydroxide (Calen) + p-monochlorophenol combination after its use as intracanal dressing, periapical lesions were induced in 60 root canals of upper and lower premolars of four dogs, After biomechanical preparation, the root canals received the intracanal medication, which was removed from the apical third after 2, 4, 7, and 14 days for chemical analysis by spectrophotometry, the results showed a p-monochlorophenol loss of approximately 50.0% in the dressing after 48 h, with no further significant loss after longer periods of times, p-Monochlorophenol was still present in the medication after 14 days.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Calcium hydroxide has been used as pulp-capping agent and canal dressing due to its antimicrobial and anti-inflammatory properties besides its ability to induce formation of mineralized tissues. The aim of this study was to evaluate the susceptibility to calcium hydroxide of 146 bacterial strains isolated from endodontic infections. MIC was determined by using an agar dilution method, while contact bactericide activity was performed through in broth. All the isolates were sensitive to calcium hydroxide in concentrations that varied from 0.5mg/ml to 128 mg/ml, and the genera Enterococcus, Pseudomonas, Staphylococcus and Actinomyces were the most resistant. Gramnegative anaerobes proved to be the most sensitive isolates. All the isolates were inhibited after 60 minutes of contact with the alkali in concentration of 100mg/ml

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Using inert gas condensation techniques the properties of sputtered neodymium-iron-born clusters were investigated. A D.C. magnetron sputtering source created vaporous Nd-Fe-B which was then condensed into clusters and deposited onto silicon substrates. A composite target of Nd-Fe-B discs on an iron plate and a composite target of Nd-(Fe-Co)-B were utilized to create clusters. The clusters were coated with a carbon layer through R.F. sputtering to prevent oxidation. Samples were investigated in the TEM and showed a size distribution with an average particle diameter of 8.11 nm. The clusters, upon deposition, were amorphous as indicated by diffuse diffraction patterns obtained through SAD. The EDS showed compositionally a direct correlation in the ratio of rare-earth to transition metals between the target and deposited samples. The magnetic properties of the as-deposited clusters showed superparamagnetic properties at high temperatures and ferromagnetic properties at low temperatures; these properties are indicative of rare-earth transition metal amorphous clusters. Annealing of samples showed an initial increase in the coercivity. Samples were annealed in an inert gas atmosphere at 600o C for increasing amounts of time. The samples showed an initial increase in coercivity, but showed no additional increases with additional annealing time. SAD of annealed cluster samples showed the presence of Nd2Fe17 and a bcc-Nd phase. The bcc-Nd is the result of oxidation at high temperatures created during annealing and surface interface energy. The magnetic properties of the annealed samples showed weak coercivity and a saturation magnetization equivalent to that of Nd2Fe17. The annealed clusters showed a slight increase in coercivity at low temperatures. These results indicate a loss of boron during the sputtering process.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Variable angle of incidence spectroscopic ellipsometry was used to determine the optical constants near the band edge of boron carbide (B5C) thin films deposited on glass and n-type Si(111) via plasma-enhanced chemical-vapor deposition. The index of refraction n, the extinction coefficient k, and the absorption coefficient are reported in the photon energy spectrum between 1.24 and 4 eV. Ellipsometry analysis of B5C films on silicon indicates a graded material, while the optical constants of B5C on glass are homogeneous. Line shape analyses of absorption data for the films on glass indicate an indirect transition at approximately 0.75 eV and a direct transition at about 1.5 eV. ©1996 American Institute of Physics.