987 resultados para Valvular prosthesis


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Transcatheter aortic valve therapies are the newest established techniques for the treatment of high risk patients affected by severe symptomatic aortic valve stenosis. The transapical approach requires a left anterolateral mini-thoracotomy, whereas the transfemoral method requires an adequate peripheral vascular access and can be performed fully percutaneously. Alternatively, the trans-subclavian access has been recently proposed as a third promising approach. Depending on the technique, the fine stent-valve positioning can be performed with or without contrast injections. The transapical echo-guided stent-valve implantation without angiography (the Lausanne technique) relies entirely on transoesophageal echocardiogramme imaging for the fine stent-valve positioning and it has been proved that this technique prevents the onset of postoperative contrast-related acute kidney failure. Recent published reports have shown good hospital outcomes and short-term results after transcatheter aortic valve implantation, but there are no proven advantages in using the transfemoral or the transapical technique. In particular, the transapical series have a higher mean logistic Euroscore of 27-35%, a procedural success rate above 95% and a mean 30-day mortality between 7.5 and 17.5%, whereas the transfemoral results show a lower logistic Euroscore of 23-25.5%, a procedural success rate above 90% and a 30-day mortality of 7-10.8%. Nevertheless, further clinical trials and long-term results are mandatory to confirm this positive trend. Future perspectives in transcatheter aortic valve therapies would be the development of intravascular devices for the ablation of the diseased valve leaflets and the launch of new stent-valves with improved haemodynamic, different sizes and smaller delivery systems.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Adequate in-vitro training in valved stents deployment as well as testing of the latter devices requires compliant real-size models of the human aortic root. The casting methods utilized up to now are multi-step, time consuming and complicated. We pursued a goal of building a flexible 3D model in a single-step procedure. We created a precise 3D CAD model of a human aortic root using previously published anatomical and geometrical data and printed it using a novel rapid prototyping system developed by the Fab@Home project. As a material for 3D fabrication we used common house-hold silicone and afterwards dip-coated several models with dispersion silicone one or two times. To assess the production precision we compared the size of the final product with the CAD model. Compliance of the models was measured and compared with native porcine aortic root. Total fabrication time was 3 h and 20 min. Dip-coating one or two times with dispersion silicone if applied took one or two extra days, respectively. The error in dimensions of non-coated aortic root model compared to the CAD design was <3.0% along X, Y-axes and 4.1% along Z-axis. Compliance of a non-coated model as judged by the changes of radius values in the radial direction by 16.39% is significantly different (P<0.001) from native aortic tissue--23.54% at the pressure of 80-100 mmHg. Rapid prototyping of compliant, life-size anatomical models with the Fab@Home 3D printer is feasible--it is very quick compared to previous casting methods.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Transcatheter aortic valve implantation is a feasible therapeutic option for selected patients with severe aortic stenosis and high or prohibitive risk for standard surgery. Lung transplant recipients are often considered high-risk patients for heart surgery because of their specific transplant-associated characteristics and comorbidities. We report a case of successful transfemoral transcatheter aortic valve replacement in a lung transplant recipient with a symptomatic severe aortic stenosis, severe left ventricular dysfunction, and end-stage renal failure 9 years after bilateral lung transplantation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

IMPORTANCE: Owing to a considerable shift toward bioprosthesis implantation rather than mechanical valves, it is expected that patients will increasingly present with degenerated bioprostheses in the next few years. Transcatheter aortic valve-in-valve implantation is a less invasive approach for patients with structural valve deterioration; however, a comprehensive evaluation of survival after the procedure has not yet been performed. OBJECTIVE: To determine the survival of patients after transcatheter valve-in-valve implantation inside failed surgical bioprosthetic valves. DESIGN, SETTING, AND PARTICIPANTS: Correlates for survival were evaluated using a multinational valve-in-valve registry that included 459 patients with degenerated bioprosthetic valves undergoing valve-in-valve implantation between 2007 and May 2013 in 55 centers (mean age, 77.6 [SD, 9.8] years; 56% men; median Society of Thoracic Surgeons mortality prediction score, 9.8% [interquartile range, 7.7%-16%]). Surgical valves were classified as small (≤21 mm; 29.7%), intermediate (>21 and <25 mm; 39.3%), and large (≥25 mm; 31%). Implanted devices included both balloon- and self-expandable valves. MAIN OUTCOMES AND MEASURES: Survival, stroke, and New York Heart Association functional class. RESULTS: Modes of bioprosthesis failure were stenosis (n = 181 [39.4%]), regurgitation (n = 139 [30.3%]), and combined (n = 139 [30.3%]). The stenosis group had a higher percentage of small valves (37% vs 20.9% and 26.6% in the regurgitation and combined groups, respectively; P = .005). Within 1 month following valve-in-valve implantation, 35 (7.6%) patients died, 8 (1.7%) had major stroke, and 313 (92.6%) of surviving patients had good functional status (New York Heart Association class I/II). The overall 1-year Kaplan-Meier survival rate was 83.2% (95% CI, 80.8%-84.7%; 62 death events; 228 survivors). Patients in the stenosis group had worse 1-year survival (76.6%; 95% CI, 68.9%-83.1%; 34 deaths; 86 survivors) in comparison with the regurgitation group (91.2%; 95% CI, 85.7%-96.7%; 10 deaths; 76 survivors) and the combined group (83.9%; 95% CI, 76.8%-91%; 18 deaths; 66 survivors) (P = .01). Similarly, patients with small valves had worse 1-year survival (74.8% [95% CI, 66.2%-83.4%]; 27 deaths; 57 survivors) vs with intermediate-sized valves (81.8%; 95% CI, 75.3%-88.3%; 26 deaths; 92 survivors) and with large valves (93.3%; 95% CI, 85.7%-96.7%; 7 deaths; 73 survivors) (P = .001). Factors associated with mortality within 1 year included having small surgical bioprosthesis (≤21 mm; hazard ratio, 2.04; 95% CI, 1.14-3.67; P = .02) and baseline stenosis (vs regurgitation; hazard ratio, 3.07; 95% CI, 1.33-7.08; P = .008). CONCLUSIONS AND RELEVANCE: In this registry of patients who underwent transcatheter valve-in-valve implantation for degenerated bioprosthetic aortic valves, overall 1-year survival was 83.2%. Survival was lower among patients with small bioprostheses and those with predominant surgical valve stenosis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We prospectively evaluated the results of our custom cementless femoral stems to ascertain whether this technology produced reasonable clinical function, complication rates, and loosening rates at midterm. Fifty-seven consecutive patients had surgery in 62 hips for primary osteoarthritis at a mean age of 57 years using a three-dimensional computed custom cementless stem. Patients were reviewed at a mean followup of 94.9 months. At review, the mean Harris hip score was 98.8 points (range, 84-100) compared with 61.1 (range, 28-78) points preoperatively. No patient complained of thigh pain. No migration or subsidence was observed. All stems were considered stable according to the radiographic criteria defined by Engh et al. There were no dislocations, no infections, and no reoperations. Our results are comparable with published results from clinical and radiologic points of view. Two problems remain unsolved: the price of a custom stem is twice as expensive as a standard stem; and we need longer term results before definitely recommending this technology as a reasonable alternative to current arthroplasties in younger patients. The data support the continued exploration of this technology with controlled clinical followup. LEVEL OF EVIDENCE: Therapeutic study, Level II-1 (prospective cohort study). See the Guidelines to Authors for a complete description of levels of evidence.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: The posterior inclination of the tibial component is an important factor that can affect the success of total knee arthroplasty. It can reduce the posterior impingement and thus increase the range of flexion, but it may also induce instability in flexion, anterior impingement between the polyethylene of postero-stabilizing knee prosthesis, and anterior conflict with the cortical bone and the stem. Although the problem is identified, there is still a debate on the ideal inclination angle and the surgical technique to avoid an excessive posterior inclination. The aim of this study was to predict the effect of a posterior inclination of the tibial component on the contact pattern on the tibial insert, using a numerical musculoskeletal model of the knee joint. Methods: A 3D finite element model of the knee joint was developed to simulate an active and loaded squat movement after total knee arthroplasty. Flexion was actively controlled by the quadriceps muscle and muscle activations were estimated from EMG data and were synchronized by a feedback algorithm. Two inclinations of the tibial tray were considered: a posterior inclination of 0° or 10°. During the entire range of flexion, the following quantities were calculated: the tibiofemoral and patello-femoral contact force, and the contact pattern on polyethylene insert. The antero-posterior displacement of the contact pattern was also measured. Abaqus 6.7 was used for all analyses. Results: The tibio-femoral and patello-femoral contact forces increased during flexion and reached respectively 4 and 7 BW (bodyweight) at 90° of flexion. They were slightly affected by the inclination of the tibial tray. Without posterior inclination, the contact pattern on the tibial insert remained centered. The contact pressure was lower than 5 MPa below 60° of flexion, but exceeded 20 MPa at 90° of flexion. The posterior inclination displaced the contact point posteriorly by 2 to 4 mm. Conclusion: The inclination of the tibial tray displaced the contactpattern towards the posterior border of the tibial insert. However, even for 10° of inclination, the contact center remained far from the posterior border (12 mm). There was no instability predicted for this movement.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the emergency situation, preoperative patient work-up for cardio-vascular surgery is quite different from the elective setting. We have analyzed a consecutive series of 5576 cases out of which 823 underwent emergency procedures (14.8%). The most frequent problems requiring emergent intervention were peripheral vascular (186 cases; 22.6% of the emergent procedure), followed by coronary artery disease (156 cases; 19.0%), thoracic aortic aneurysms (86 cases; 10.4%), abdominal aortic aneurysms (54 cases; 6.6%), congenital heart disease (36 cases: 4.4%), heart and heart lung transplantation (31 cases; 3.8%), problems with cardiac rythm (25 cases: 3.0%), and others (267 cases: 32.4%). Classification by proportion of urgent procedures with reference to elective operations shows a different picture. As a matter of fact transplantations were always emergency procedures (100%), whereas repair of aortic dissections type A and B was an emergency procedure in 81.5%. Emergency thoracic and abdominal aortic aneurysm repair accounted for 30% and 20% respectively and the corresponding proportion for peripheral vascular surgery is 19%. However, emergency surgery for acute coronary ischemia, valvular and congenital heart disease accounted for somewhat less than 10% for each group of these pathologies. Systematic pre-operative diagnostic work-up is a recognized tool for procedure related risk assessment and superior management of diseases. However, hemodynamic instability and other time related events correlated with negative outcome, are the main driving forces for accelerated diagnostic pathways

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Bioprosthetic aortic valve replacement is the treatment of choice for patients over 65 years of age suffering from aortic valve disease, and for younger patients with contraindications to long-lasting anticoagulation. Despite several technical improvements to reduce the risk of structural valve degeneration (SVD), the risk of SVD still exists, in particular for hemodialysis patients and patients under 60 years of age at surgery. Redo open heart surgery is the treatment of choice in case of valve degeneration, but caries a higher surgical risk when elderly patients with comorbidities are concerned. In the last 5 years, transcatheter aortic "valve-in-valve" procedures represent a valid alternative to standard redo surgery in selected patients. Valve-in-valve procedures represent a less invasive approach in high-risk patients and the published results are very encouraging. Technical success rates of 100% have been reported, as have the absence of paravalvular leaks, acceptable trans-valvular gradients (depending on the size of the original bioprosthesis), and low complication rates. The current article focuses on choosing the correct transcutaneous valve to match the patient's existing bioprosthesis for valve-in-valve procedures.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES Little is known about the stent deformability required for optimal stented heart valve bioprosthesis design. Therefore, two bioprosthetic valves with known good long-term clinical results were tested. The strain in the radial direction of the stent posts of these valves was compared with contemporary bioprosthetic valves and a native porcine aortic root. METHODS Medtronic Intact and Carpentier-Edwards Standard (CES), and four contemporary bioprostheses, including one self-expanding prosthesis, were tested with three sonomicrometry probes per valve fixed at commissure attachment points. The mean values from 2400 data points from three measurements of the interprobe distances were used to calculate the radius of the circle circumscribed around the three probes. Changes in the radius of the aortic root at pressures 70-90 and 120-140 mmHg (pressure during diastole and systole) and that of the stent posts at 70-90 and 0-10 mmHg (transvalvular pressure gradient during diastole and systole) were compared. RESULTS An increase in radius by 7.3 ± 2.6, 8.7 ± 0.0 and 3.9 ± 0.0% for the porcine aortic root, CES and Intact valves, respectively, was observed during transition from diastolic to systolic pressure and less for contemporary bioprostheses-mean 2.5 ± 0.9%, lowest 1.2 ± 0.0. CONCLUSIONS The results indicate that the radial deformability of bioprosthetic valve stent posts can be as low as 1.2% for xenoaortic and 3.0% for xenopericardial prostheses with no compromise of valve durability. Although these results suggest that valve stent post-deformability might not be of critical importance, a concrete answer to the question of the significance of stent deformability for valve durability can be obtained only by acquiring long-term follow-up results for valve prostheses with rigid stents.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Avec 95% de bons résultats à 10 ans, on peut considérer aujourd'hui que l'arthroplastie totale du genou est un traitement fiable des gonarthroses chez des patients âgés à demande fonctionnelle raisonnable. Les quatre complications potentielles principales après la mise en place d'une prothèse totale du genou sont le descellement aseptique, l'infection, le manque de flexion et les douleurs persistantes. En cas de problème avec une prothèse totale du genou, il faut toujours exclure la présence d'une infection avant d'envisager une autre raison. Les innovations actuelles en arthroplastie du genou doivent viser à améliorer les résultats chez les patients jeunes et actifs i.e. tant au niveau de la conception des nouveaux implants, voire des matériaux plus résistants, que des techniques chirurgicales elles-mêmes. Total knee arthroplasty: current advances and results With a 95% success rate at 10 years, total knee arthroplasty can be regarded today as a reliable way of treating knee osteoarthritis in elderly patients with reasonable functional demands. The four main potential complications after placing of a total knee prosthesis are aseptic loosening, infection, lack of flexion and persistent pain. If a problem arises with a total knee prosthesis, infection must always be ruled out before considering other causes. Current innovations in knee arthroplasty should be aimed at improving results in young and active patients, i.e. in regard to both the design of new implants, or tougher materials, and to the surgical techniques themselves.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: Endovascular treatment of wide-neck bifurcation aneurysms often results in incomplete occlusion or aneurysm recurrence. The goals of this study were to compare results of coil embolization with or without the assistance of self-expandable stents and to examine how stents may influence neointima formation. MATERIALS AND METHODS: Wide-neck bifurcation aneurysms were constructed in 24 animals and, after 4-6 weeks, were randomly allocated to 1 of 5 groups: 1) coil embolization using the assistance of 1 braided stent (n = 5); 2) coil embolization using the assistance of 2 braided stents in a Y configuration (n = 5); 3) coil embolization without stent assistance (n = 6); 4) Y-stenting alone (n = 4); and 5) untreated controls (n = 4). Angiographic results were compared at baseline and at 12 weeks, by using an ordinal scale. Neointima formation at the neck at 12 weeks was compared among groups by using a semiquantitative grading scale. Bench studies were performed to assess stent porosities. RESULTS: Initial angiographic results were improved with single stent-assisted coiling compared with simple coiling (P = .013). Angiographic results at 12 weeks were improved with any stent assistance (P = .014). Neointimal closure of the aneurysm neck was similar with or without stent assistance (P = .908), with neointima covering coil loops but rarely stent struts. Y-stent placement alone had no therapeutic effect. Bench studies showed that porosities can be decreased with stent compaction, but a relatively stable porous transition zone was a limiting factor. CONCLUSIONS: Stent-assisted coiling may improve results of embolization by allowing more complete initial coiling, but these high-porosity stents did not provide a scaffold for more complete neointimal closure of aneurysms.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

L'évaluation des résultats des arthroplasties totales du genou demande une évaluation du geste thérapeutique ou clinique, mais doit également tenir compte de l'impact de ce geste sur l'état de santé global du patient (somatique, psychologique, social) et intégrer son degré de satisfaction. La complexité croissante des instruments de mesure du suivi a de quoi décourager le chirurgien praticien déjà surchargé par son activité clinique quotidienne. L'apparition des scores, des études prospectives et des analyses statistiques, telles les courbes de survie, ont certainement permis une appréciation plus objective de nos résultats, tout en accroissant nos connaissances et en améliorant notre pratique quotidienne. La question aujourd'hui n'est plus de savoir si un suivi clinique de nos patients est utile, mais plutôt de choisir les bons instruments et de définir les buts de l'analyse tout en cherchant comment implanter cette démarche de manière réaliste dans nos pratiques. Les scores classiques, aussi imparfaits soient-ils, restent pour l'instant utiles. Largement diffusés à travers le monde, appliqués de manière prospective, ces outils de suivi orientés vers la clinique et la radiologie sont le fondement du suivi prospectif des implants. Au quotidien, ils permettent un suivi en temps réel des implants d'un service ou d'une institution. Cependant, leur faiblesse intrinsèque résidant dans l'inaptitude à saisir le point de vue du patient, il semble inéluctable d'y adjoindre des instruments psychométriques. Dans l'avenir, la recherche devrait se concentrer vers le développement d'outils adaptés, capables de cerner avec une plus grande précision l'attente des patients et de technologies accessibles à chaque praticien pour mesurer objectivement les capacités fonctionnelles de leurs patients avec plus d'acuité. Le développement de systèmes permettant une évaluation objective de la fonction quotidienne du patient revêt un intérêt tout particulier. Parallèlement, un effort doit être fait au niveau des sociétés spécialisées nationales et internationales pour harmoniser leurs protocoles de suivi.