914 resultados para ULTRA-LOW TEMPERATURE


Relevância:

90.00% 90.00%

Publicador:

Resumo:

This thesis presents details of the design and development of novel tools and instruments for scanning tunneling microscopy (STM), and may be considered as a repository for several years' worth of development work. The author presents design goals and implementations for two microscopes. First, a novel Pan-type STM was built that could be operated in an ambient environment as a liquid-phase STM. Unique features of this microscope include a unibody frame, for increased microscope rigidity, a novel slider component with large Z-range, a unique wiring scheme and damping mechanism, and a removable liquid cell. The microscope exhibits a high level of mechanical isolation at the tunnel junction, and operates excellently as an ambient tool. Experiments in liquid are on-going. Simultaneously, the author worked on designs for a novel low temperature, ultra-high vacuum (LT-UHV) instrument, and these are presented as well. A novel stick-slip vertical coarse approach motor was designed and built. To gauge the performance of the motor, an in situ motion sensing apparatus was implemented, which could measure the step size of the motor to high precision. A new driving circuit for stick-slip inertial motors is also presented, that o ffers improved performance over our previous driving circuit, at a fraction of the cost. The circuit was shown to increase step size performance by 25%. Finally, a horizontal sample stage was implemented in this microscope. The build of this UHV instrument is currently being fi nalized. In conjunction with the above design projects, the author was involved in a collaborative project characterizing N-heterocyclic carbene (NHC) self-assembled monolayers (SAMs) on Au(111) films. STM was used to characterize Au substrate quality, for both commercial substrates and those manufactured via a unique atomic layer deposition (ALD) process by collaborators. Ambient and UHV STM was then also used to characterize the NHC/Au(111) films themselves, and several key properties of these films are discussed. During this study, the author discovered an unexpected surface contaminant, and details of this are also presented. Finally, two models are presented for the nature of the NHC-Au(111) surface interaction based on the observed film properties, and some preliminary theoretical work by collaborators is presented.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Résumé : Le transistor monoélectronique (SET) est un dispositif nanoélectronique très attractif à cause de son ultra-basse consommation d’énergie et sa forte densité d’intégration, mais il n’a pas les capacités suffisantes pour pouvoir remplacer complètement la technologie CMOS. Cependant, la combinaison de la technologie SET avec celle du CMOS est une voie intéressante puisqu’elle permet de profiter des forces de chacune, afin d’obtenir des circuits avec des fonctionnalités additionnelles et uniques. Cette thèse porte sur l’intégration 3D monolithique de nanodispositifs dans le back-end-of-line (BEOL) d’une puce CMOS. Cette approche permet d’obtenir des circuits hybrides et de donner une valeur ajoutée aux puces CMOS actuelles sans altérer le procédé de fabrication du niveau des transistors MOS. L’étude se base sur le procédé nanodamascène classique développé à l’UdeS qui a permis la fabrication de dispositifs nanoélectroniques sur un substrat de SiO2. Ce document présente les travaux réalisés sur l’optimisation du procédé de fabrication nanodamascène, afin de le rendre compatible avec le BEOL de circuits CMOS. Des procédés de gravure plasma adaptés à la fabrication de nanostructures métalliques et diélectriques sont ainsi développés. Le nouveau procédé nanodamascène inverse a permis de fabriquer des jonctions MIM et des SET métalliques sur une couche de SiO2. Les caractérisations électriques de MIM et de SET formés avec des jonctions TiN/Al2O3 ont permis de démontrer la présence de pièges dans les jonctions et la fonctionnalité d’un SET à basse température (1,5 K). Le transfert de ce procédé sur CMOS et le procédé d’interconnexions verticales sont aussi développés par la suite. Finalement, un circuit 3D composé d’un nanofil de titane connecté verticalement à un transistor MOS est réalisé et caractérisé avec succès. Les résultats obtenus lors de cette thèse permettent de valider la possibilité de co-intégrer verticalement des dispositifs nanoélectroniques avec une technologie CMOS, en utilisant un procédé de fabrication compatible.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

In this thesis the low-temperature magnetism of the spin-ice systems Dy2Ti2O7 and Ho2Ti2O7 is investigated. In general, a clear experimental evidence for a sizable magnetic contribution kappa_{mag} to the low-temperature, zero-field heat transport of both spin-ice materials is observed. This kappa_{mag} can be attributed to the magnetic monopole excitations, which are highly mobile in zero field and are suppressed by a rather small external field resulting in a drop of kappa(H). Towards higher magnetic fields, significant field dependencies of the phononic heat conductivities kappa_{ph}(H) of Ho2Ti2O7 and Dy2Ti2O7 are found, which are, however, of opposite signs, as it is also found for the highly dilute reference materials (Ho0.5Y0.5)2Ti2O7 and (Dy0.5Y0.5)2Ti2O7. The dominant effect in the Ho-based materials is the scattering of phonons by spin flips which appears to be significantly stronger than in the Dy-based materials. Here, the thermal conductivity is suppressed due to enhanced lattice distortions observed in the magnetostriction. Furthermore, the thermal conductivity of Dy2Ti2O7 has been investigated concerning strong hysteresis effects and slow-relaxation processes towards equilibrium states in the low-temperature and low-field regime. The thermal conductivity in the hysteretic regions slowly relaxes towards larger values suggesting that there is an additional suppression of the heat transport by disorder in the non-equilibrium states. The equilibration can even be governed by the heat current for particular configurations. A special focus was put on the dilution series Dy2Ti2O7x. From specific heat measurements, it was found that the ultra-slow thermal equilibration in pure spin ice Dy2Ti2O7 is rapidly suppressed upon dilution with non-magnetic yttrium and vanishes completely for x>=0.2 down to the lowest accessible temperatures. In general, the low-temperature entropy of (Dy1-xYx)2Ti2O7, considerably decreases with increasing x, whereas its temperature-dependence drastically increases. Thus, it could be clarified that there is no experimental evidence for a finite zero-temperature entropy in (Dy1-xYx)2Ti2O7 above x>=0.2, in clear contrast to the finite residual entropy S_{P}(x) expected from a generalized Pauling approximation. A similar discrepancy is also present between S_{P}(x) and the low-temperature entropy obtained by Monte Carlo simulations, which reproduce the experimental data from 25 K down to 0.7 K, whereas the data at 0.4 K are overestimated. A straightforward description of the field-dependence kappa(H) of the dilution series with qualitative models justifies the extraction of kappa_{mag}. It was observed that kappa_{mag} systematically scales with the degree of dilution and its low-field decrease is related to the monopole excitation energy. The diffusion coefficient D_{mag} for the monopole excitations was calculated by means of c_{mag} and kappa_{mag}. It exhibits a broad maximum around 1.6 K and is suppressed for T<=0.5 K, indicating a non-degenerate ground state in the long-time limit, and in the high-temperature range for T>=4 K where spin-ice physics is eliminated. A mean-free path of 0.3 mum is obtained for Dy2Ti2O7 at about 1 K within the kinetic gas theory.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

In modern society, the body health is a very important issue to everyone. With the development of the science and technology, the new and developed body health monitoring device and technology will play the key role in the daily medical activities. This paper focus on making progress in the design of the wearable vital sign system. A vital sign monitoring system has been proposed and designed. The whole detection system is composed of signal collecting subsystem, signal processing subsystem, short-range wireless communication subsystem and user interface subsystem. The signal collecting subsystem is composed of light source and photo diode, after emiting light of two different wavelength, the photo diode collects the light signal reflected by human body tissue. The signal processing subsystem is based on the analog front end AFE4490 and peripheral circuits, the collected analog signal would be filtered and converted into digital signal in this stage. After a series of processing, the signal would be transmitted to the short-range wireless communication subsystem through SPI, this subsystem is mainly based on Bluetooth 4.0 protocol and ultra-low power System on Chip(SoC) nRF51822. Finally, the signal would be transmitted to the user end. After proposing and building the system, this paper focus on the research of the key component in the system, that is, the photo detector. Based on the study of the perovskite materials, a low temperature processed photo detector has been proposed, designed and researched. The device is made up of light absorbing layer, electron transporting and hole blocking layer, hole transporting and electron blocking layer, conductive substrate layer and metal electrode layer. The light absorbing layer is the important part of whole device, and it is fabricated by perovskite materials. After accepting the light, the electron-hole pair would be produced in this layer, and due to the energy level difference, the electron and hole produced would be transmitted to metal electrode and conductive substrate electrode through electron transporting layer and hole transporting layer respectively. In this way the response current would be produced. Based on this structure, the specific fabrication procedure including substrate cleaning; PEDOT:PSS layer preparation; pervoskite layer preparation; PCBM layer preparation; C60, BCP, and Ag electrode layer preparation. After the device fabrication, a series of morphological characterization and performance testing has been done. The testing procedure including film-forming quality inspection, response current and light wavelength analysis, linearity and response time and other optical and electrical properties testing. The testing result shows that the membrane has been fabricated uniformly; the device can produce obvious response current to the incident light with the wavelength from 350nm to 800nm, and the response current could be changed along with the light wavelength. When the light wavelength keeps constant, there exists a good linear relationship between the intensity of the response current and the power of the incident light, based on which the device could be used as the photo detector to collect the light information. During the changing period of the light signal, the response time of the device is several microseconds, which is acceptable working as a photo detector in our system. The testing results show that the device has good electronic and optical properties, and the fabrication procedure is also repeatable, the properties of the devices has good uniformity, which illustrates the fabrication method and procedure could be used to build the photo detector in our wearable system. Based on a series of testing results, the paper has drawn the conclusion that the photo detector fabricated could be integrated on the flexible substrate and is also suitable for the monitoring system proposed, thus made some progress on the research of the wearable monitoring system and device. Finally, some future prospect in system design aspect and device design and fabrication aspect are proposed.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Following work exploring the low temperature electrolysis in alkaline media, using graphite consumable anodes, from which syngas was obtained1, laboratory studies have been conducted in acid media pursuing higher efficiency in the production of hydrogen and synthetic fuels. Experiments were conducted in an own designed undivided planar cell with 25 cm2 geometrical area electrodes using a 0.5 M H2SO4 solution with and without Fe(II) additions. Fe2+ oxidizes to Fe3+ at the anode surface. The redox couple Fe3+/ Fe2+ acts as an oxidation mediator not only oxidizing the bulk and detached graphite but also the surface functional groups. The practical experimental potential for graphite oxidation is within the range for the electroxidation of the Fe redox couple giving as a result a 4-fold increase in the amount of produced CO2 at near room temperature, when using 0.025 M FeSO4.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

There is increasing interest in evaluating the environmental effects on crop architectural traits and yield improvement. However, crop models describing the dynamic changes in canopy structure with environmental conditions and the complex interactions between canopy structure, light interception, and dry mass production are only gradually emerging. Using tomato (Solanum lycopersicum L.) as a model crop, a dynamic functional-structural plant model (FSPM) was constructed, parameterized, and evaluated to analyse the effects of temperature on architectural traits, which strongly influence canopy light interception and shoot dry mass. The FSPM predicted the organ growth, organ size, and shoot dry mass over time with high accuracy (>85%). Analyses of this FSPM showed that, in comparison with the reference canopy, shoot dry mass may be affected by leaf angle by as much as 20%, leaf curvature by up to 7%, the leaf length: width ratio by up to 5%, internode length by up to 9%, and curvature ratios and leaf arrangement by up to 6%. Tomato canopies at low temperature had higher canopy density and were more clumped due to higher leaf area and shorter internodes. Interestingly, dry mass production and light interception of the clumped canopy were more sensitive to changes in architectural traits. The complex interactions between architectural traits, canopy light interception, dry mass production, and environmental conditions can be studied by the dynamic FSPM, which may serve as a tool for designing a canopy structure which is 'ideal' in a given environment.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Solid oxide fuel cell (SOFC) is an electrochemical device that converts chemical energy into electric power with high efficiency. Traditional SOFC has its disadvantages, such as redox cycling instability and carbon deposition while using hydrocarbon fuels. It is because traditional SOFC uses Ni-cermet as anode. In order to solve these problems, ceramic anode is a good candidate to replace Ni. However, the conductivity of most ceramic anode materials are much lower than Ni metal, and it introduces high ohmic resistance. How to increase the conductivity is a hot topic in this research field. Based on our proposed mechanism, several types of ceramic materials have been developed. Vanadium doped perovskite, Sr1-x/2VxTi1-xO3 (SVT) and Sr0.2Na0.8Nb1-xVxO3 (SNNV), achieved the conductivity as high as 300 S*cm-1 in hydrogen, without any high temperature reduction. GDC electrolyte supported cell was fabricated with Sr0.2Na0.8Nb0.9V0.1O3 and the performance was measured in hydrogen and methane respectively. Due to vanadium’s intrinsic problems, the anode supported cell is not easy. Fe doped double perovskite Sr2CoMoO6 (SFCM) was also developed. By carefully doping Fe, the conductivity was improved over one magnitude, without any vigorous reducing conditions. SFCM anode supported cell was successfully fabricated with GDC as the electrolyte. By impregnating Ni-GDC nano particles into the anode, the cell can be operated at lower temperatures while having higher performance than the traditional Ni-cermet cells. Meanwhile, this SFCM anode supported SOFC has long term stability in the reformate containing methane. During the anode development, cathode improvement caused by a thin Co-GDC layer was observed. By adding this Co-GDC layer between the electrolyte and the cathode, the interfacial resistance decreases due to fast oxygen ion transport. This mechanism was confirmed via isotope exchange. This Co-GDC layer works with multiple kinds of cathodes and the modified cell’s performance is 3 times as the traditional Ni-GDC cell. With this new method, lowering the SOFC operation temperature is feasible.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Systematic low-temperature measurements of the thermal conductivity, specific heat, dielectric constant, and temperature-dependent ultrasound velocity have been made on a single piece of vitreous silica. These measurements were repeated after fast neutron irradiation of the material. It was found that the irradiation produced changes of the same relative magnitude in the low-temperature excess specific heat C , the thermal conductivity K, ex and the anomalous temperature dependence of the ultrasound velocity Deltav/v. A corresponding change in the temperature dependent dielectric constant was not observed. It is therefore likely that K and Deltav/v are determined by the same localized excitations responsible for C , but the temperature dependence of the dielectric constant may have a different, though possibly related, origin. Furthermore, a consistent account for the measured C , K, ex and Deltav/v of unirradiated silica is given by the tunneling-state model with a single, energy-dependent density of states. Changes in these three properties due to irradiation can be explained by altering only the density of tunneling states incorporated in the model.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

O desenvolvimento de métodos adequados que permitam o monitoramento de resíduos e contaminantes em alimentos é de suma importância pois é a única forma de garantir a segurança dos alimentos evitando danos à saúde do consumidor. Para isso, fazse necessário que estes métodos sejam rápidos, fáceis e de baixo custo, capazes de detectar a presença de resíduos em concentrações baixas e em diferentes matrizes. Este trabalho consistiu no desenvolvimento de método para determinação de 5 sedativos e 14 β-bloqueadores em amostras de rim suíno e posterior análise por Cromatografia Líquida Acoplada à Espectrometria de Massas em Série (LC-MS/MS). O procedimento de extração que melhor se adequou para análise destes compostos consistiu na pesagem de 2 g de amostra e adição de 10 mL de acetonitrila seguida de homogeneização com auxílio de Ultra-Turrax e mesa agitadora. Após extração, as amostras foram submetidas a duas técnicas de clean-up, sendo elas, congelamento do extrato à baixa temperatura e extração em fase sólida dispersiva (d-SPE) utilizando como sorvente Celite® 545. Uma etapa de concentração foi realizada com auxílio de concentrador de amostras sob fluxo de N2 e temperatura controlada. As amostras secas foram retomadas com metanol e analisadas utilizando sistema LC-MS/MS com Ionização por Eletrospray (ESI), operando no modo MRM positivo, coluna Poroshell 120 EC-C18 (3,0 x 50 mm, 2,7 μm) para separação dos analitos, e gradiente de fase móvel composta por (A) solução aquosa acidificada com 0,1% de ácido fórmico (v/v) e (B) metanol 0,1% ácido fórmico (v/v). Os parâmetros de validação avaliados foram linearidade, seletividade, efeito matriz, precisão, veracidade, recuperação, limite de decisão, capacidade de detecção, incerteza da medição, robustez, limite de detecção e de quantificação. Além disso foram observados os critérios de desempenho aplicáveis à detecção por espectrometria de massas e estabilidade dos compostos. A recuperação foi avaliada em 10 μg kg-1 e a veracidade em 5, 10 e 15 μg kg-1 apresentando resultados satisfatórios entre 70 - 85% e 90 - 101%, respectivamente. O limite de quantificação determinado foi de 2,5 μg kg-1 , exceto para carazolol que foi de 1,25 μg kg- 1 . O estudo de linearidade foi realizado entre 0 e 20 μg kg-1 apresentando coeficientes de determinação superiores a 0,98. Estes procedimentos foram realizados através de análise de matriz branca fortificada. Além disso, o presente método foi utilizado para analisar carazolol, azaperone e azaperol em amostras de ensaio colaborativo de rim suíno, apresentando resultados muito próximos aos reais. Portanto, é possível concluir que o método desenvolvido é adequado para análise de sedativos e β-bloqueadores através de extração dos compostos e limpeza do extrato eficientes utilizando procedimentos rápidos, fáceis e de baixo custo, garantindo resultados seguros e confiáveis.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

International audience

Relevância:

90.00% 90.00%

Publicador:

Resumo:

X-Ray Powder Diffraction (XRPD) laboratory is a facility placed at Servicios Centrales de apoyo a la Investigación (SCAI) at University of Malaga (UMA) http://www.scai.uma.es/. This facility has three XRPD diffractometers and a diffractometer to measure high-resolution thin-films. X´Pert PRO MPD from PANalytical. This is a bragg-brentano (theta/2theta) with reflection geometry diffractometer which allows to obtain high resolution XRPD data with strictly monochromatic CuKα1 radiation (λ=1.54059Å) [Ge(111) primary monochromator] and an automatic sample charger. Moreover, it has parallel monochromatic CuKα1 radiation (λ=1.54059Å) with an hybrid Ge(220) monochromator for capillary and multiproposal (bulk samples up to 1 Kg) sample holders. The HTK1200N chamber from Anton Paar allows collecting high resolution high temperature patterns. EMPYREAN from PANalytical. This diffractometer works in reflection and transmission geometries with theta/theta goniometer, using CuKα1,2 radiation (λ=1.5418Å), a focusing X-ray mirror and a ultra-fast PIXCEL 3D detector with 1D and 2D collection data modes (microstructural and preferred orientation analysis). Moreover, the TTK450N chamber allows low temperature and up to 450ºC studies. A D8 ADVANCE (BRUKER) was installed in April 2014. It is the first diffractometer in Europe equipped with a Johansson Ge(111) primary monochromator, which gives a strictly monochromatic Mo radiation (λ=0.7093 Å) [1]. It works in transmission mode (with a sample charger) with this high resolution configuration. XRPD data suitable for PDF (Pair Distribution Function) analysis can be collected with a capillary sample holder, due to the high energy and high resolution capabilities of this diffractometer. Moreover, it has a humidity chamber MHC-trans from Anton Paar working on transmission mode with MoKα1 (measurements can be collected at 5 to 95% of relative humidity (from 20 to 80 ºC) and up to 150ºC [2]). Furthermore, this diffractometer also has a reaction chamber XRK900 from Anton Paar (which uses CuKα1,2 radiation in reflection mode), which allows data collection from room temperature to 900ºC with up to 10 bar of different gases. Finally, a D8 DISVOVER A25 from BRUKER was installed on December 2014. It has a five axis Euler cradler and optics devices suitable for high resolution thin film data collection collected in in-plane and out-of-plane modes. To sum up, high-resolution thin films, microstructural, rocking-curve, Small Angle X-ray Scattering (SAXS), Grazing incident SAXS (GISAXS), Ultra Grazing incident diffraction (Ultra-GID) and microdiffraction measurements can be performed with the appropriated optics and sample holders. [1] L. León-Reina, M. García-Maté, G. Álvarez-Pinazo, I. Santacruz, O. Vallcorba, A.G. De la Torre, M.A.G. Aranda “Accuracy in Rietveld quantitative phase analysis: a comparative study of strictly monochromatic Mo and Cu radiations” J. Appl. Crystallogr. 2016, 49, 722-735. [2] J. Aríñez-Soriano, J. Albalad, C. Vila-Parrondo, J. Pérez-Carvajal, S. Rodríguez-Hermida, A. Cabeza, F. Busqué, J. Juanhuix, I. Imaz, Daniel Maspoch “Single-crystal and humidity-controlled powder diffraction study of the breathing effect in a metal-organic framework upon water adsorption/desorption” Chem. Commun., 2016, DOI: 10.1039/C6CC02908F.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Hypersonic aerospace vehicles are severely limited by the lack of adequate high temperature materials that can withstand the harsh hypersonic environment. Tantalum carbide (TaC), with a melting point of 3880°C, is an ultrahigh temperature ceramic (UHTC) with potential applications such as scramjet engines, leading edges, and zero erosion nozzles. However, consolidation of TaC to a dense structure and its low fracture toughness are major challenges that make it currently unviable for hypersonic applications. In this study, Graphene NanoPlatelets (GNP) reinforced TaC composites are synthesized by spark plasma sintering (SPS) at extreme conditions of 1850˚C and 80-100 MPa. The addition of GNP improves densification and enhances fracture toughness of TaC by up to ~100% through mechanisms such as GNP bending, sliding, pull-out, grain wrapping, crack bridging, and crack deflection. Also, TaC-GNP composites display improved oxidation behavior over TaC when exposed to a high temperature plasma flow exceeding 2500 ˚C.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Lactococcus garvieae is an important fish and an opportunistic human pathogen. The genomic sequences of several L. garvieae strains have been recently published, opening the possibility of global studies on the biology of this pathogen. In this study, a whole genome DNA microarray of two strains of L. garvieae was designed and validated. This DNA microarray was used to investigate the effects of growth temperature (18°C and 37°C) on the transcriptome of two clinical strains of L. garvieae that were isolated from fish (Lg8831) and from a human case of septicemia (Lg21881). The transcriptome profiles evidenced a strain-specific response to temperature, which was more evident at 18°C. Among the most significant findings, Lg8831 was found to up-regulate at 18°C several genes encoding different cold-shock and cold-induced proteins involved in an efficient adaptive response of this strain to low-temperature conditions. Another relevant result was the description, for the first time, of respiratory metabolism in L. garvieae, whose gene expression regulation was temperature-dependent in Lg21881. This study provides new insights about how environmental factors such as temperature can affect L. garvieae gene expression. These data could improve our understanding of the regulatory networks and adaptive biology of this important pathogen.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

When NaCl precipitates out of a saturated solution, it forms anhydrous crystals of halite at temperatures above +0.11?C, but at temperatures below this threshold it instead precipitates as the dihydrate ‘‘hydrohalite,’’ NaCl * 2H2O. When sea ice is cooled, hydrohalite begins to precipitate within brine inclusions at about -23C. In this work, hydrohalite crystals are examined in laboratory experiments: their formation, their shape, and their response to warming and desiccation. Sublimation of a sea ice surface at low temperature leaves a lag deposit of hydrohalite, which has the character of a fine powder. The precipitation of hydrohalite in brine inclusions raises the albedo of sea ice, and the subsequent formation of a surface accumulation further raises the albedo. Although these processes have limited climatic importance on the modern Earth, they would have been important in determining the surface types present in regions of net sublimation on the tropical ocean in the cold phase of a Snowball Earth event. However, brine inclusions in sea ice migrate downward to warmer ice, so whether salt can accumulate on the surface depends on the relative rates of sublimation and migration. The migration rates are measured in a laboratory experiment at temperatures from -2C to -32C; the migration appears to be too slow to prevent formation of a salt crust on Snowball Earth.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This short paper presents a numerical method for spatial and temporal downscaling of solar global radiation and mean air temperature data from global weather forecast models and its validation. The final objective is to develop a prediction algorithm to be integrated in energy management models and forecast of energy harvesting in solar thermal systems of medium/low temperature. Initially, hourly prediction and measurement data of solar global radiation and mean air temperature were obtained, being then numerically downscaled to half-hourly prediction values for the location where measurements were taken. The differences between predictions and measurements were analyzed for more than one year of data of mean air temperature and solar global radiation on clear sky days, resulting in relative daily deviations of around -0.9±3.8% and 0.02±3.92%, respectively.