955 resultados para Turbina idraulica effetto Venturi flusso libero acqua fluente
Resumo:
The nanometric powders have special features that usually result in new properties, originating applications or expanding them in various fields of knowledge. Because having a high area/volume ratio, phenomena such as superficial strength of adsorption becomes greater than the weight of the powder which makes more difficult its handling. The high power of agglomeration of these powders requires study and development of equipments to enable its management into the plasma torch. The objective of this work is to develop a powder feeder which can solve the mainly problems about insertion of powder into the thermal spray developed in the laboratory of plasmas, which are carried out with plasma torch arc not transferred (plasma spray). Therefore, it was made a aluminum s powder feeder and tests were performed to verify their operation and determine its rate of deposition by spraying powders of niobium pentoxide (Nb2O5) and titanium dioxide (TiO2) with particle sizes less than 250 mesh (<0.063 mm). We used masses of 0.5 g - 1.0 g and 1.5 g of each powder in tests lasting 15 seconds - 20 to 25 seconds for each mass. The tests were performed in two ways: at atmospheric pressure using argon gas with a flow of 9 l / min as carrier gas and through a Venturi pipe also using argon gas with a flow of 9 l / min as carrier gas and with a flow of 20 l/min as the feed gas passing through the Venturi pipe. The powder feeder developed in this paper is very easy to be handling and building, resulting in feeding rate of 0.25 cm3/min - 1.37 cm3/min. The TiO2 showed higher feeding rates than the Nb2O5 in all tests, and the best rates were obtained with tests using mass 1.5 g and time of 15 seconds, reaching feeding rate of 1.37 cm3/min. The flow of feed had low interference in feeding rate during the tests
Resumo:
The proposal of this work is to evaluate the influence of the organic matter on the results of the analyses of the metals (Zn, Pb, Al, Cu, Cr, Fe, Cd e Ni) for Atomic Absorption Spectrometry (AAS), so much in the extraction stage as in the reading using for that the chemometrics. They were used for this study sample of bottom sediment collected in river Jundiaí in the vicinity of the city of Macaíba-RN, commercial humus and water of the station of treatment of sewer of UFRN. Through the analyses accomplished by EAA it was verified that the interference of the organic matter happens in the extraction stage and not in the reading. With relationship to the technique of X Ray Fluorescence Spectrometry (XRFS), the present work has as intended to evaluate the viability of this technique for quantitative analysis of trace metals (Cr, Ni, Cu, Zn, Rb, Sr and Pb) in having leached obtained starting from the extraction with acqua regia for an aqueous solution. The used samples constitute the fine fraction (<0.063 mm) of sediments of swamp of the river Jundiaí. The preparation of tablets pressed starting from the dry residue of those leached it allowed your analysis in the solid form. This preliminary study shows that, in the case of the digestion chemistry partially of the fine fractions of bottom sediments used for environmental studies, the technique of applied EFRX to the analysis of dry residues starting from having leached with acqua regia, compared her it analyzes of the leached with ICP-OES, it presents relative mistakes for Cu, Pb, Sr and Zn below 10%
Resumo:
O presente estudo tem como objetivos levantar dados sobre o que os indivíduos portadores de hipertensão arterial pensam sobre a sua doença e verificar a ocorrência do processo de comunicação entre estes e os profissionais que atuam junto aos mesmos. Foram entrevistados 66 clientes, obtendo-se 73 narrativas, constatando-se que a maioria (69 narrativas) dos participantes da pesquisa faz correlação com o conceito de hipertensão arterial, ainda que de maneira pouco elaborada. Apesar de 95% dos clientes fazerem alguma referência à doença, não significa que as orientações recebidas anteriormente foram aprendidas. Espera-se que o enfermeiro por desempenhar um importante papel dentro da equipe multiprofissional, identifique as possíveis barreiras relativas ao processo de comunicação, havendo daí a intervenção junto aos elementos que podem estar dificultando ou impedindo a compreensão necessária para que o cliente assuma seu autocuidado.
Resumo:
Pesquisa qualitativa orientada pelos referenciais teórico-metodológicos: Interacionismo Simbólico e Grounded Theory para compreender o processo planejamento-implementação da Sistematização da Assistência de Enfermagem (SAE), segundo dois grupos amostrais: enfermeiros e auxiliares/técnicos de enfermagem de um hospital universitário, e desenvolver uma síntese dos modelos teóricos representativos dessas experiências. A saturação teórica configurou-se mediante a análise da 24ª entrevista não diretiva de 12 enfermeiros e de 12 técnicos de enfermagem, lotados em unidades de internação. da análise emergiram dois modelos teóricos, cuja síntese originou o terceiro, intitulado Entre o êxito e a frustração com a operacionalização da SAE: recursos humanos como componente determinante para a visibilidade do enfermeiro no processo de trabalho. Este modelo desvela o déficit de recursos humanos, impulsionando o enfermeiro a realizar uma SAE ilusória, e perpetuando um processo cíclico de sofrimento, por vivenciar a invisibilidade de sua práxis no processo de trabalho.
Resumo:
O estudo teve como objetivo avaliar a produção científica publicada entre 1991 e 1995, para identificar como o assunto adesão ao tratamento anti-hipertensivo vem sendo abordado. Foram analisados 107 artigos científicos. Os resultados mostraram que a adesão foi abordada da seguinte maneira: 68% relacionaram ao paciente, 63% ao tratamento farmacológico, 62% a aspectos gerais, 39% ao tratamento não farmacológico, 34% a fatores institucionais, e 8% relativos à, doença. A adesão ao tratamento anti-hipertensivo tem sido um desafio no controle da hipertensão arterial e conhecer como este assunto está sendo enfocado na literatura pode contribuir para aumentar adesão ao tratamento na hipertensão arterial.
Resumo:
A gravidade do paciente ou o número de intervenções nem sempre serão proporcionais à carga de trabalho de enfermagem. Este estudo descritivo teve como objetivo demonstrar a trajetória da construção de um aplicativo (software) com o conteúdo do Nursing Activities Score e suas características operacionais. Foi realizado um teste piloto com 12 pacientes seguindo-se a coleta de dados por 90 dias consecutivos em 123 pacientes. Houve compatibilidade na transmissão de dados do Personal Digital Assistent para o computador de mesa, via wireless. A construção do aplicativo resultou em um sistema com coleta e administração de dados e permitiu realizar a interface gráfica. A utilização do aplicativo possibilita o uso de um sistema tecnológico para aplicação diária, com alimentação de um banco de dados sobre as características dos cuidados requeridos. Conhecendo a evolução destas variáveis durante a internação, o enfermeiro poderá planejar, intervir e avaliar a qualidade do cuidado.
Resumo:
Computerized technological resources have become essential in education, particularly for teaching topics that require the performance of specific tasks. These resources can effectively help the execution of such tasks and the teaching-learning process itself. After the development of a Web site on the topic of nursing staff scheduling, this study aimed at comparing the development of students involved in the teaching-learning process of the previously mentioned topic, with and without the use of computer technology. Two random groups of undergraduate nursing students from a public university in São Paulo state, Brazil, were organized: a case group (used the Web site) and a control group (did not use the Web site). Data were collected from 2003 to 2005 after approval by the Research Ethics Committee. Results showed no significant difference in motivation or knowledge acquisition. A similar performance for the two groups was also verified. Other aspects observed were difficulty in doing the nursing staff scheduling exercise and the students' acknowledgment of the topic's importance for their training and professional lives; easy access was considered to be a positive aspect for maintaining the Web site.
Resumo:
Trata-se de um estudo que teve como objetivo, identificar como é oferecido o ensino do processo de enfermagem nas Escolas de Graduação em Enfermagem do Estado de São Paulo. A população foi composta de 247 docentes. Na metodologia de estudo foi elaborado um questionário, que foi enviado aos 899 docentes das 32 instituições públicas e privadas de Graduação em Enfermagem do Estado de São Paulo. Os resultados permitiram constatar que os fatores que dificultam o ensino do processo de enfermagem foram numericamente maiores que os que facilitam. Entretanto, o ensino do processo de enfermagem, apesar das dificuldades apresentadas, tem sido oferecido pelos docentes das escolas públicas e privadas do Estado de São Paulo.
Resumo:
Purpose This in vitro study compared the dimensional accuracy of two impression techniques Duralay splinted impression copings (D) and metal splinted impression copings (M) for implant supported pros theses Materials and Methods A master cast with four parallel implant abutment analogs and a passive framework were fabricated Vinyl polysiloxane impression material was used for all impressions with a metal stock tray Two groups (D and M) were tested (n = 5) The measurement method employed was just one titanium screw tightened to the framework Each group s measurements were analyzed using software that received the images of a video camera coupled to a stereomicroscope at X100 magnification The results were analyzed statistically (t test) Results The mean values of abutment/framework interface gaps were master cast = 32 mu m (SD 2), group D = 165 mu m (SD 60), and group M = 69 mu m (SD 36) There was a statistically significant difference between the D and M groups (P <= 001) Conclusion Under the limitations of this study, it could be suggested that a more accurate working cast can be fabricated using metal splinted impression copings INT J ORAL MAXILLOFAC IMPLANTS 2010 25 1153-1158
Resumo:
Purpose: This in vitro study compared the dimensional accuracy of a stone index and of two impression techniques (squared impression copings and modified squared impression copings) for implant-supported prostheses. Materials and Methods: A master cast with four parallel implant-abutment analogs and a passive framework were fabricated. Vinyl polysiloxane impression material was used for all impressions with a metal stock tray. Three groups of impressions were tested (n = 5): index (1), squared (S), and modified squared (MS). The measurement method employed was just one titanium screw tightened to the framework. The measurements (60 gap values) were analyzed using software that received the images from a video camera coupled to a stereomicroscope at x 100 magnification. The results were evaluated statistically (analysis of variance, Holm-Sidak method, alpha = .05). Results: The mean abutment/framework interface gaps were: master cast = 31.63 mu m; group I = 45.25 mu m; group S = 96.14 mu m; group MS = 51.20 mu m. No significant difference was detected among the index and modified squared techniques (P = .05). Conclusion: Under the limitations of this study, the techniques modified squared and index generated more accurate casts than the squared technique. INT J ORAL MAXILLOFAC IMPLANTS 2010;25:715-721
Resumo:
Purpose: To investigate, in vitro, the dimensional accuracy of two impression techniques (squared impression copings and squared impression copings sandblasted and coated with impression adhesive) made of vinyl polysiloxane and polyether impression materials. Materials and Methods: A master cast (control group) with four parallel implant abutment analogs, a passive framework, and a custom aluminum tray was fabricated. Four groups (n = 5 each group) were tested: squared Impregum (SI), squared Express (SE), sandblasted adhesive squared Impregum (ASI), and sandblasted adhesive squared Express (ASE). The measurement method employed was just one titanium screw tightened to the framework. A stereomicroscope was used to evaluate the fit of the framework by measuring the size of the gap between the abutment and the framework. The results were analyzed statistically. Results: The mean values for the abutment/framework interface gaps were: master cast, 31.63 mu m (SD 2.16); SI, 38.03 mu m (SD 9.29); ASI, 46.80 mu m (SD 8.47); SE, 151.21 mu m (SD 22.79); and ASE, 136.59 mu m (SD 29.80). No significant difference was detected between the SI or ASI techniques and the master cast. No significant difference was detected between the SE and ASE techniques. Conclusion: Within the limitations of this study, it can be concluded that Impregum Soft medium consistency was the best impression material and the impression technique did not influence the accuracy of the stone casts. INT J ORAL MAXILLOFAC IMPLANTS 2010;25:771-776
Resumo:
Purpose: This in vitro study evaluated the dimensional accuracy of two impression techniques (tapered and splinted) with two stock trays (plastic and metal) for implant-supported prostheses. Materials and Methods: A master cast with four parallel abutment analogs and a passive framework were fabricated. Polyvinyl siloxane impression material was used for all impressions with two metal stock trays and two plastic stock trays (closed and open trays). Four groups (tapered plastic, splinted plastic, tapered metal, and splinted metal) and a control group (master cast) were tested (n = 5 for each group). After the framework was seated on each of the casts, one abutment screw was tightened, and the marginal gap between the abutment and framework on the other side was measured with a stereomicroscope. The measurements were analyzed with the Kruskal-Wallis one-way analysis of variance on ranks test followed by the Dunn method. Results: The mean values (+/- standard deviations) for the abutment/framework interface gaps were: master cast, 32 +/- 2 mu m; tapered metal, 44 +/- 10 mu m; splinted metal, 69 +/- 28 mu m; tapered plastic, 164 +/- 58 mu m; splinted plastic, 128 +/- 47 mu m. No significant difference was detected between the master cast, tapered metal, and splinted metal groups or between the tapered and splinted plastic groups. Conclusions: In this study, the rigidity of the metal stock tray ensured better results than the plastic stock tray for implant impressions with a high-viscosity impression material (putty). Statistically similar results were obtained using tapered impression copings and splinted squared impression copings. The tapered impression copings technique and splinted squared impression copings technique with a metal stock tray produced precise casts with no statistically significant difference in interface gaps compared to the master cast. INT J ORAL MAXILLOFAC IMPLANTS 2012;27:544-550.
Resumo:
Purpose: The purpose of this in vitro study was to compare the dimensional accuracy of a stone index and of 3 impression techniques (tapered impression copings, squared impression copings, and squared impression copings splinted with acrylic resin) associated with 3 pouring techniques (conventional, pouring using latex tubes fitted onto analogs, and pouring after joining the analogs with acrylic resin) for implant-supported prostheses. Materials and Methods: A mandibular brass cast with 4 stainless steel implant-abutment analogs, a framework, and 2 aluminum custom trays were fabricated. Polyether impression material was used for all impressions. Ten groups were formed (a control group and 9 test groups formed by combining each pouring technique and impression technique). Five casts were made per group for a total of 50 casts and 200 gap values (1 gap value for each implant-abutment analog). Results: The mean gap value with the index technique was 27.07 mu m. With the conventional pouring technique, the mean gap values were 116.97 mu m for the tapered group, 5784 mu m for the squared group, and 73.17 mu m for the squared splinted group. With pouring using latex tubes, the mean gap values were 65.69 mu m for the tapered group, 38.03 mu m for the squared group, and 82.47 mu m for the squared splinted group. With pouring after joining the analogs with acrylic resin, the mean gap values were 141.12 jum for the tapered group, 74.19 mu m for the squared group, and 104.67 mu m for the squared splinted group. No significant difference was detected among Index, squarellatex techniques, and master cast (P > .05). Conclusions: The most accurate impression technique utilized squared copings. The most accurate pouring technique for making the impression with tapered or squared copings utilized latex tubes. The pouring did not influence the accuracy of the stone casts when using splinted squared impression copings. Either the index technique or the use of squared coping combined with the latex-tube pouring technique are preferred methods for making implant-supported fixed restorations with dimensional accuracy.
Resumo:
TEMA: o padrão de fala fluente atribuído aos indivíduos com a síndrome de Williams-Beuren sustenta-se pela efetividade da alça fonológica. Alguns estudos citaram a ocorrência de disfluências decorrentes de prejuízos léxico-semânticos, entretanto, a quebra de fluência não foi bem especificada quanto ao tipo e freqüência de ocorrência. OBJETIVO: obter o perfil da fluência da fala de indivíduos com a SWB e comparar com um grupo controle pareado por gênero e idade mental semelhante. MÉTODO: foram avaliados 12 sujeitos com síndrome de Williams-Beuren a com idade cronológica entre 6,6 a 23,6 e idade mental de 4,8 a 14,3 anos que foram comparados a outros 12 sujeitos de idade mental semelhante com ausência de dificuldades de linguagem/aprendizagem. Para avaliação da fluência foi utilizado o Teste de Linguagem Infantil - ABFW, na área de fluência, que possibilitou classificar, quantificar e comparar os dois grupos quanto às tipologias e freqüência de rupturas e velocidade de fala. RESULTADOS: o grupo com a síndrome de Williams-Beuren (SWB) apresentou maior porcentagem de descontinuidade de fala e freqüência aumentada para disfluências comuns do tipo hesitação e repetição de palavras quando comparados aos indivíduos com idade mental semelhante e com desenvolvimento típico de fala e linguagem. CONCLUSÃO: O perfil da fluência da fala apresentado pelos indivíduos com a SWB neste estudo mostrou a presença de disfluências que podem ser decorrentes de prejuízo no processamento léxico-semântico e sintático da informação verbal; ressaltando-se, pois a necessidade de investigações mais sistemáticas sobre este tema.
Resumo:
CMS is a general purpose experiment, designed to study the physics of pp collisions at 14 TeV at the Large Hadron Collider ( LHC). It currently involves more than 2000 physicists from more than 150 institutes and 37 countries. The LHC will provide extraordinary opportunities for particle physics based on its unprecedented collision energy and luminosity when it begins operation in 2007. The principal aim of this report is to present the strategy of CMS to explore the rich physics programme offered by the LHC. This volume demonstrates the physics capability of the CMS experiment. The prime goals of CMS are to explore physics at the TeV scale and to study the mechanism of electroweak symmetry breaking - through the discovery of the Higgs particle or otherwise. To carry out this task, CMS must be prepared to search for new particles, such as the Higgs boson or supersymmetric partners of the Standard Model particles, from the start- up of the LHC since new physics at the TeV scale may manifest itself with modest data samples of the order of a few fb(-1) or less. The analysis tools that have been developed are applied to study in great detail and with all the methodology of performing an analysis on CMS data specific benchmark processes upon which to gauge the performance of CMS. These processes cover several Higgs boson decay channels, the production and decay of new particles such as Z' and supersymmetric particles, B-s production and processes in heavy ion collisions. The simulation of these benchmark processes includes subtle effects such as possible detector miscalibration and misalignment. Besides these benchmark processes, the physics reach of CMS is studied for a large number of signatures arising in the Standard Model and also in theories beyond the Standard Model for integrated luminosities ranging from 1 fb(-1) to 30 fb(-1). The Standard Model processes include QCD, B-physics, diffraction, detailed studies of the top quark properties, and electroweak physics topics such as the W and Z(0) boson properties. The production and decay of the Higgs particle is studied for many observable decays, and the precision with which the Higgs boson properties can be derived is determined. About ten different supersymmetry benchmark points are analysed using full simulation. The CMS discovery reach is evaluated in the SUSY parameter space covering a large variety of decay signatures. Furthermore, the discovery reach for a plethora of alternative models for new physics is explored, notably extra dimensions, new vector boson high mass states, little Higgs models, technicolour and others. Methods to discriminate between models have been investigated. This report is organized as follows. Chapter 1, the Introduction, describes the context of this document. Chapters 2-6 describe examples of full analyses, with photons, electrons, muons, jets, missing E-T, B-mesons and tau's, and for quarkonia in heavy ion collisions. Chapters 7-15 describe the physics reach for Standard Model processes, Higgs discovery and searches for new physics beyond the Standard Model.