682 resultados para Toric implantable collamer lens
Resumo:
Patients with an implantable cardioverter defibrillator (ICD) have an ongoing risk of sudden incapacitation that might cause harm to others while driving a car. Driving restrictions vary across different countries in Europe. The most recent recommendations for driving of ICD patients in Europe were published in 1997 and focused mainly on patients implanted for secondary prevention. In recent years there has been a vast increase in the number of patients with an ICD and in the percentage of patients implanted for primary prevention. The EHRA task force on ICD and driving was formed to reassess the risk of driving for ICD patients based on the literature available. The recommendations are summarized in the following table and are further explained in the document. [table: see text] Driving restrictions are perceived as difficult for patients and their families, and have an immediate consequence for their lifestyle. To increase the adherence to the driving restrictions, adequate discharge of education and follow-up of patients and family are pivotal. The task force members hope this document may serve as an instrument for European and national regulatory authorities to formulate uniform driving regulations.
Resumo:
UNLABELLED The automatic implantable defibrillator (AID) is the treatment of choice for primary and secondary prevention of sudden death. At the Instituto Nacional de Cardiología, since October 1996 until January 2002, 25 patients were implanted with 26 AID. There were 23 men (92%) and the mean age of the whole group, was 51.4 years. Twenty-three patients (92%) presented structural heart disease, the most common was ischemic heart disease in 13 patients (52%), with a mean ejection fraction of 37.8%. One patient without structural heart disease had Brugada Syndrome. The most frequent clinical arrhythmia was ventricular tachycardia in 14 patients (56%). The mean follow-up was of 29.3 months during which a total of 30 events of ventricular arrhythmia were treated through AID; six of them were inappropriate due to paroxismal atrial fibrillation; 10 AID patients (34%) have not applied for therapy. Three patients (12%) of the group died due to congestive heart failure refractory to pharmacologic treatment. CONCLUSION The implant of the AID is a safe and effective measure for primary and secondary prevention of sudden death. World-wide experience evidences, that this kind of device has not modified the mortality rate due to heart failure in these patients, but it has diminished sudden arrhythmic death.
Resumo:
PURPOSE To report the incidence of anterior capsule contraction syndrome (ACCS) and to present a novel minimally invasive bimanual technique for anterior segment revision surgery associated with ACCS with anterior flexion of the intraocular lens haptics. METHODS A consecutive cohort of 268 eyes of 161 patients undergoing phacoemulsification and implantation of the same type of hydrophilic acrylic aspheric intraocular lens cohort were analysed and a novel technique of minimally invasive bimanual technique for anterior segment revision surgery is described. RESULTS We identified four eyes (1.5%) of three patients with advanced ACCS. Successful restoration of a clear visual axis with minimal induction of astigmatism and rapid visual rehabilitation was achieved in all four cases. CONCLUSION This technique is a safe and minimally invasive alternative to laser or vitrector-cut capsulotomy to restore a clear visual axis. In cases of advanced ACCS, it offers the option for haptic reposition or amputation.
Resumo:
Introduction: Photography through a microscope is virtually identical to that used with an astronomical telescope. For years, the 35mm camera was the choice for microphotography, but we live in a digital camera age now. We describe a custom homemade adapter that can be fit most of the cameras and microscopes. [See PDF for complete abstract]
Resumo:
In external beam radiation therapy, it is imperative that the prescribed dose is administered to the correct location and in the correct amount. Though several ex vivo methods of quality assurance are currently employed to achieve this goal, verifying that the correct dose is received within the patient in situ is impossible without the capability of measuring dose inside the patient. Recently, a method of measuring dose delivered within the patient has been developed, an implantable MOSFET dosimeter. This dosimeter is implanted within the patient and records the dose received. Since the dosimeter is implanted in the patient, it could serve a dual function as a fiducial marker for image guided radiation therapy (IGRT) treatment if it could be modified to be visible on x-rays. In this study, modifications to the MOSFET dosimeter were made to increase its visibility for IGRT treatment. To test whether the modifications hindered the dosimeter’s ability to accurately measure and transmit dose information, the energy dependence, angular dependence and wireless read range of the modified dosimeter were measured and compared to unmodified dosimeters. It was found that the modified dosimeter performed as well as the unmodified dosimeter while also being suitable for use as a fiducial marker for IGRT treatment.
Resumo:
Sanitation has evolved from a purely technical discipline to one that includes social, environmental, economic and, increasingly, gender considerations. However, blurry notions of gender are frequently offered in the sanitation literature. Although it has been recognized that gender-responsive sanitation does not mean ‘toilets for women’, substantial alternatives are rarely debated. We structure our review of sanitation in developing countries along three lines: we start by fine-tuning the concept of gender both from the academic and the practitioner's perspective, analyse relevant developments in gender-specific policies and programming, and finally review the most appropriate toilet room and menstrual hygiene technologies. We argue that strategies to make technologies gender-responsive need to be based upon a thorough analysis of the social arrangements of the intimate, and how these are negotiated and institutionalized in a specific context. A lack of robust gender-segregated data on sanitation policies and technologies, along with reductionist framings of gender are to blame for limited progress in verifying the need for, and impact of, gender-responsive sanitation. Technology and policy development and implementation would benefit from gender-considerate interpretations of shame, dignity, safety and status. Further progress could be achieved by improving the translation process between different academic framings of the sanitation crisis. Keywords: appropriate technology; development; gender; menstrual hygiene management (MHM); sanitation
Resumo:
Starting from the early descriptions of Kraepelin and Bleuler, the construct of schizotypy was developed from observations of aberrations in nonpsychotic family members of schizophrenia patients. In contemporary diagnostic manuals, the positive symptoms of schizotypal personality disorder were included in the ultra high-risk (UHR) criteria 20 years ago, and nowadays are broadly employed in clinical early detection of psychosis. The schizotypy construct, now dissociated from strict familial risk, also informed research on the liability to develop any psychotic disorder, and in particular schizophrenia-spectrum disorders, even outside clinical settings. Against the historical background of schizotypy it is surprising that evidence from longitudinal studies linking schizotypy, UHR, and conversion to psychosis has only recently emerged; and it still remains unclear how schizotypy may be positioned in high-risk research. Following a comprehensive literature search, we review 18 prospective studies on 15 samples examining the evidence for a link between trait schizotypy and conversion to psychosis in 4 different types of samples: general population, clinical risk samples according to UHR and/or basic symptom criteria, genetic (familial) risk, and clinical samples at-risk for a nonpsychotic schizophrenia-spectrum diagnosis. These prospective studies underline the value of schizotypy in high-risk research, but also point to the lack of evidence needed to better define the position of the construct of schizotypy within a developmental psychopathology perspective of emerging psychosis and schizophrenia-spectrum disorders
Resumo:
We regularize compact and non-compact Abelian Chern–Simons–Maxwell theories on a spatial lattice using the Hamiltonian formulation. We consider a doubled theory with gauge fields living on a lattice and its dual lattice. The Hilbert space of the theory is a product of local Hilbert spaces, each associated with a link and the corresponding dual link. The two electric field operators associated with the link-pair do not commute. In the non-compact case with gauge group R, each local Hilbert space is analogous to the one of a charged “particle” moving in the link-pair group space R2 in a constant “magnetic” background field. In the compact case, the link-pair group space is a torus U(1)2 threaded by k units of quantized “magnetic” flux, with k being the level of the Chern–Simons theory. The holonomies of the torus U(1)2 give rise to two self-adjoint extension parameters, which form two non-dynamical background lattice gauge fields that explicitly break the manifest gauge symmetry from U(1) to Z(k). The local Hilbert space of a link-pair then decomposes into representations of a magnetic translation group. In the pure Chern–Simons limit of a large “photon” mass, this results in a Z(k)-symmetric variant of Kitaev’s toric code, self-adjointly extended by the two non-dynamical background lattice gauge fields. Electric charges on the original lattice and on the dual lattice obey mutually anyonic statistics with the statistics angle . Non-Abelian U(k) Berry gauge fields that arise from the self-adjoint extension parameters may be interesting in the context of quantum information processing.
Resumo:
BACKGROUND We observed a case of conductor externalization in a Biotronik Linox lead. OBJECTIVE To investigate lead performance of the Linox and identical Sorin Vigila lead and prevalence of conductor externalization. METHODS We compared lead performance of all Linox and Vigila leads implanted at our center (BL group; n=93) with all Boston Scientific Endotak Reliance leads (ER group; n=190) and Medtronic Sprint Quattro leads (SQ group; n=202) implanted during the same period. We screened all BL group patients for conductor externalization. RESULTS We identified 8 cases of lead failures in the BL group (index case of conductor externalization; 6 cases of non-physiological high rate sensing; one case of high voltage conductor fracture). Prospective, fluoroscopic screening of 98% of all active BL group cases revealed one additional case of conductor externalization. Median follow-up was 41, 27 and 29 months for the BL group, ER group and SQ group, respectively, lead survival 94.9%, 99.2% and 100% at 3 years, and 88%, 97.5% and 100% at 5 years (p=0.038 for BL group vs. ER group, and p=0.007 for BL group vs. SQ group by the log-rank test). Younger age at implant was an independent predictor for lead failure in the BL group (adjusted HR 0.85 [95% confidence interval 0.77-0.94]; p=0.001). CONCLUSION At our center, survival of the Linox lead is 88% at five years and significantly worse than its comparators. Conductor externalization is present in a minority of failed Linox leads. Younger age at implant is an independent predictor of Linox lead failure.
Resumo:
Lack of linearity and sensitivity, oxygen dependence, biofouling and tissue inflammation hinder the development of implantable biosensors for continuous monitoring of glucose. Herein, we report the development of stacked outer membranes based on LBL/PVA hydrogels that improve sensor sensitivity, linearity, oxygen independence and counter biofouling and inflammation. While the inner LBL membrane affords tunable diffusivity, the outer PVA is capable of releasing anti-inflammatory drugs/tissue response modifying agents to counter acute and chronic inflammation, and to induce neo-angiogenesis at the implant site. Sensors were fabricated by immobilizing GOx enzyme on top of 50 μm platinum wires, followed by deposition of stacked LBL/PVA hydrogel membranes. The response of the sensors at 0.7V to various glucose concentrations was studied. Michelis-Menten analysis was performed to quantify sensor performance in terms of linearity and oxygen dependence. The interplay between sensor performance and inward glucose diffusivity was elucidated using (i) various LBL membranes and (ii) various freeze-thaw (FT) cycles of PVA. Incorporation of LBL/PVA stacked membranes resulted in an 8 fold increase in sensor linearity and a 9 fold decrease in oxygen dependence compared to controls. The enhancement in the sensor performance is attributed to (i) the oxygen storing capability of PVA hydrogel due to the formation of hydrophobic domains during its freezing/ thawing employed for its physical crosslinking and (ii) regulation of glucose flux by the inner LBL membrane. Such membranes offer significant advantages over presently available outer membranes in lieu of (i) their ability to control inflammation, (ii) their modulus that closely matches that of subcutaneous human tissue, (iii) non-necessity of reactive chemical crosslinking agents, (iv) tunable sensitivity and (v) supplemental storage of oxygen.
Resumo:
Background. The number of infections of cardiac implantable electronic devices (CIED) continues to escalate out of proportion to the increase rate of device implantation. Staphylococcal organisms account for 70% to 90% of all CIED infections. However, little is known about non-staphylococcal infections, which have been described only in case reports, small case series or combined in larger studies with staphylococcal CIED infections, thereby diluting their individual impact. ^ Methods. A retrospective review of hospital records of patients admitted with a CIED-related infections were identified within four academic hospitals in Houston, Texas between 2002 and 2009. ^ Results. Of the 504 identified patients with CIED-related infection, 80 (16%) had a non-staphylococcal infection and were the focus of this study. Although the demographics and comorbities of subjects were comparable to other reports, our study illustrates many key points: (a) the microbiologic diversity of non-staphylococcal infections was rather extensive, as it included other Gram-positive bacteria like streptococci and enterococci, a variety of Gram-negative bacteria, atypical bacteria including Nocardia and Mycobacteria, and fungi like Candida and Aspergillus; (b) the duration of CIED insertion prior to non-staphylococcal infection was relatively prolong (mean, 109 ± 27 weeks), of these 44% had their device previously manipulated within a mean of 29.5 ± 6 weeks; (c) non-staphylococcal organisms appear to be less virulent, cause prolonged clinical symptoms prior to admission (mean, 48 ± 12.8 days), and are associated with a lower mortality (4%) than staphylococcal organisms; (d) thirteen patients (16%) presented with CIED-related endocarditis; (e) although not described in prior reports, we identified 3 definite and 2 suspected cases of secondary Gram-negative bacteremia seeding of the CIED; and (f) inappropriate antimicrobial coverage was provided in approximately 50% of patients with non-staphylococcal infections for a mean period of 2.1 days. ^ Conclusions. Non-staphylococcal CIED-related infections are prevalent and diverse with a relatively low virulence and mortality rate. Since non-staphylococcal organisms are capable of secondarily seeding the CIED, a high suspicion for CIED-related infection is warranted in patients with bloodstream infection. Additionally, in patients with suspected CIED infection, adequate Gram positive and -negative antibacterial coverage should be administered until microbiologic data become available.^
Resumo:
Making healthcare comprehensive and more efficient remains a complex challenge. Health Information Technology (HIT) is recognized as an important component of this transformation but few studies describe HIT adoption and it's effect on the bedside experience by physicians, staff and patients. This study applied descriptive statistics and correlation analysis to data from the Patient-Centered Medical Home National Demonstration Project (NDP) of the American Academy of Family Physicians. Thirty-six clinics were followed for 26 months by clinician/staff questionnaires and patient surveys. This study characterizes those clinics as well as staff and patient perspectives on HIT usefulness, the doctor-patient relationship, electronic medical record (EMR) implementation, and computer connections in the practice throughout the study. The Global Practice Experience factor, a composite score related to key components of primary care, was then correlated to clinician and patient perspectives. This study found wide adoption of HIT among NDP practices. Patient perspectives on HIT helpfulness on the doctor-patient showed a suggestive trend that approached statistical significance (p = 0.172). Clinicians and staff noted successful integration of EMR into clinic workflow and their perception of helpfulness to the doctor-patient relationship show a suggestive increase also approaching statistical significance (p=0.06). GPE was correlated with clinician/staff assessment of a helpful doctor-patient relationship midway through the study (R 0.460, p = 0.021) with the remaining time points nearing statistical significance. GPE was also correlated to both patient perspectives of EMR helpfulness in the doctor-patient relationship (R 0.601, p = 0.001) and computer connections (R 0.618, p = 0.0001) at the start of the study. ^