963 resultados para Thickness of the mucosa


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: The authors present the unique clinical features of cavitary uveal melanoma. Design: Retrospective chart review. Participants: Eight patients with cavitary uveal melanoma. Main Outcome Measures: The clinical, ultrasonographic, and histopathologic features of eight patients with cavitary melanoma of the ciliary body were studied. Results: In all eyes there was a brown ciliary body mass that blocked transmission of light on trans-scleral transillumination. Ocular ultrasonography revealed a large, single hollow cavity (unilocular 'pseudocyst') in five cases and multiple hollow cavities (multilocular 'pseudocyst') in three cases. The cavity occupied a mean of 55% of the entire mass thickness (range, 31%-79%). In five cases, a basal uveal mass was noted on ultrasonography. Four patients underwent tumor resection; one had enucleation, and three had 1251 radioactive plaque treatment. In the five cases confirmed histopathologically, the cavitation was empty, contained erythrocytes, serous fluid, and/or pigment-laden macrophages. In no case was the cavity lined by necrotic tumor, endothelial cells, or epithelial cells. Conclusion: Ciliary body melanoma can develop an intralesional cavity resembling an intraocular cyst. The presence of a solid mass at the base and a thick wall surrounding the cavity can assist in the differentiation of cavitary melanoma from benign cyst.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Evidence of 11-year Schwabe solar sunspot cycles, El Niño-Southern Oscillation (ENSO) and the Pacific Decadal Oscillation (PDO) were detected in an annual record of diatomaceous laminated sediments from anoxic Effingham Inlet, Vancouver Island, British Columbia. Radiometric dating and counting of annual varves dates the sediments from AD 1947-1993. Intact sediment slabs were X-rayed for sediment structure (lamina thickness and composition based on gray-scale), and subsamples were examined for diatom abundances and for grain size. Wavelet analysis reveals the presence of ~2-3, ~4.5, ~7 and ~9-12-year cycles in the diatom record and an w11e13 year record in the sedimentary varve thickness record. These cycle lengths suggest that both ENSO and the sunspot cycle had an influence on primary productivity and sedimentation patterns. Sediment grain size could not be correlated to the sunspot cycle although a peak in the grain size data centered around the mid-1970s may be related to the 1976-1977 Pacific climate shift, which occurred when the PDO index shifted from negative (cool conditions) to positive (warm conditions). Additional evidence of the PDO regime shift is found in wavelet and cross-wavelet results for Skeletonema costatum, a weakly silicified variant of S. costatum, annual precipitation and April to June precipitation. Higher spring (April/May) values of the North Pacific High pressure index during sunspot minima suggest that during this time, increased cloud cover and concomitant suppression of the Aleutian Low (AL) pressure system led to strengthened coastal upwelling and enhanced diatom production earlier in the year. These results suggest that the 11-year solar cycle, amplified by cloud cover and upwelling changes, as well as ENSO, exert significant influence on marine primary productivity in the northeast Pacific. The expression of these cyclic phenomena in the sedimentary record were in turn modulated by the phase of PDO, as indicated by the change in period of ENSO and suppression of the solar signal in the record after the 1976-1977 regime shift. © 2013 Elsevier Ltd and INQUA. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: Acquired pit-like changes of the optic nerve head (APON) are characteristic of glaucomatous damage and may be a sign of a localized susceptibility of the optic nerve. Thus, it is possible that biomechanical properties of the ocular tissues may play a pressure-independent role in the pathogenesis of glaucoma. Corneal hysteresis (CH) appears to provide information of the biomechanical properties of the ocular hull tissues. The purpose of this study was to compare CH of patients with primary open angle glaucoma (POAG) with and without APON. Methods: A prospective case control study was done. POAG patients with and without APON were measured using the Ocular Response Analyzer by masked investigators. Patients in both groups were matched for sex, age, corneal thickness, and type of glaucoma according to maximal IOP (NTG or POAG). Statistical analysis was done using ANOVA. Results: Corneal hysteresis of 16 glaucomatous eyes with APON and 32 controls (glaucoma without APON) was measured. The mean (±SD) CH in the APON group was 8.89 (±1.53) and 10.2 (±1.05) in the control group. The difference is statistically significant (p = 0.005). Conclusions: Corneal hysteresis in POAG patients with APON was significantly lower than in patients that did not have such structural changes of the optic disc. These findings may reflect pressure-independent mechanisms involved in the pathogenesis of such glaucomatous optic nerve changes. © Springer-Verlag 2007.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: A detailed investigation of the gross and microscopic anatomy of ligamentum flavum. Methods: Material included 14 lumbar vertebral columns obtained from the Anatomy Department, King Faisal University, Dammam during the period between January 2005 and January 2006. Height, width, and thickness of ligamenta flava were measured. A microscopic study was also performed. Computed tomography scan was carried out on the lumbar vertebrae of 30 patients for measuring the ligamentum flavum. Results: The anatomical results showed that the right and left ligamenta flava join in the midline forming an acute angle with a ventral opening. The ligamentum flavum is rectangular and has 4 borders and 2 surfaces. It is attached inferiorly to the superior edge and the postero-superior surface of the lamina below. It is attached superiorly to the inferior edge and the antero-inferior surface of the lamina above. Its height ranges from 14-22 mm. The width of its lower part ranges from 11-23 mm, and the thickness ranges from 3.5-6 mm. The histological results revealed that it is comprised chiefly of elastic fibres and some collagen fibres. Conclusion: The information reported in this study is of clinical value in the practice of lumbar epidural anesthesia or analgesia. Epidural puncture will be best performed through the lower and medial portion of the ligamentum flavum slightly lateral to the midline.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Light emitted from metal/oxide/metal tunnel junctions can originate from the slow-mode surface plasmon polariton supported in the oxide interface region. The effective radiative decay of this mode is constrained by competition with heavy intrinsic damping and by the need to scatter from very small scale surface roughness; the latter requirement arises from the mode's low phase velocity and the usual momentum conservation condition in the scattering process. Computational analysis of conventional devices shows that the desirable goals of decreased intrinsic damping and increased phase velocity are influenced, in order of priority, by the thickness and dielectric function of the oxide layer, the type of metal chosen for each conducting electrode, and temperature. Realizable devices supporting an optimized slow-mode plasmon polariton are suggested. Essentially these consist of thin metal electrodes separated by a dielectric layer which acts as a very thin (a few nm) electron tunneling barrier but a relatively thick (several 10's of nm) optically lossless region. (C) 1995 American Institute of Physics.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Epitaxial BaTiO3 films and epitaxial BaTiO3/SrTiO3 multilayers were grown by pulsed laser deposition on vicinal surfaces of (001)-oriented Nb-doped SrTiO3 (SrTiO3:Nb) single-crystal substrates. Atomic force microscopy was used to investigate the surface topography of the deposited films. The morphology of the films, of the BaTiO3/SrTiO3 interfaces, and of the column boundaries was investigated by cross-sectional high-resolution transmission electron microscopy. Measurements of the dielectric properties were performed by comparing BaTiO3 films and BaTiO3/SrTiO3 multilayers of different numbers of individual layers, but equal overall thickness. The dielectric loss saturates for a thickness above 300 nm and linearly decreases with decreasing film thickness below a thickness of 75 nm. At the same thickness of 75 nm, the thickness dependence of the dielectric constant also exhibits a change in the linear slope both for BaTiO3 films and BaTiO3/SrTiO3 multilayers. This behaviour is explained by the change observed in the grain morphology at a thickness of 75 nm. For the thickness dependence of the dielectric constant, two phenomenological models are considered, viz. a 'series-capacitor' model and a 'dead-layer' model.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents the numerical simulation of the ultimate behaviour of 85 one-way and two-way spanning laterally restrained concrete slabs of variable thickness, span, reinforcement ratio, strength and boundary conditions reported in literature by different authors. The developed numerical model was described and all the assumptions were illustrated. ABAQUS, a Finite Element Analysis suite of software, was employed. Non-linear implicit static general analysis method offered by ABAQUS was used. Other analysis methods were also discussed in general in terms of application such as Explicit Dynamic Analysis and Riks method. The aim is to demonstrate the ability and efficacy of FEA to simulate the ultimate load behaviour of slabs considering different material properties and boundary conditions. The authors intended to present a numerical model that provides consistent predictions of the ultimate behaviour of laterally restrained slabs that could be used as an alternative for expensive real life testing as well as for the design and assessment of new and existing structures respectively. The enhanced strength of laterally-restrained slabs compared with conventional design methods predictions is believed to be due to compressive membrane action (CMA). CMA is an inherent phenomenon of laterally restrained concrete beams/slabs. The numerical predictions obtained from the developed model were in good correlation with the experimental results and with those obtained from the CMA method developed at the Queen’s University Belfast, UK.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The interaction between the face coat material of a mould and the titanium alloy will cause oxygen penetration during the casting and solidification process, resulting in the formation of an α-case interaction layer at the metal surface that influences the mechanical properties of the cast components. In this study, the influence of α-case thickness and loading positions in a Ti–6Al–4V (Ti64) alloy on metal hardness, impact properties and bending strength was investigated. The results showed that the metal surface α-case consisted of many coarse α laths which has a higher hardness than metal matrix. The mechanical properties of the alloy are influenced by the α-case. The alloy bending strength was observed to have changed linearly with the thickness of sample.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the southwestern part of the Aiguilles Rouges massif (pre-Alpine basement of the Helvetic realm, western Alps), a metavolcanic sequence, newly defined as the ``Greenstone Unit'',is exposed in two NS trending belts of several 100 metres in thickness. It consists of epidote amphibolites, partly epidote and/or calcic amphibole-bearing greenschists, and small amounts of alkali feldspar-bearing greenschists, which underwent low- to medium-grade metamorphism during Visean oblique collision. Metamorphic calcic amphiboles and epidotes show strong chemical zoning, whereas metamorphic plagioclase is exclusively albitic in composition (An 1-3). The SiO2 content of the subalkaline tholeiitic to calc-alkaline suite ranges continuously from 44 wt% to 73 wt%,but andesitic rocks predominate. The majority of samples have chemical compositions close to recent subduction-related lavas; some are even restricted to recent oceanic arcs (extremely low Ta and Nb contents, high La/Nb and Th/Ta ratios). But several basaltic to basalto-andesitic samples resemble continental tholeiites (low Th/Ta, La/Nb ratio). As it is very probable that both lava types are to some extent contemporaneous, it is proposed that the Greenstone Unit represents a former oceanic volcanic are which temporarily underwent extension during which emplacement of continental tholeiite-like rocks occurred. The cause of the extension remains ambiguous. Considering palaeotectonic significance and age of other metavolcanic units in the Aiguilles Rouges massif, the Greenstone Unit most likely formed in the Early Palaeozoic.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Interest in mixed-valent perovskite manganese oxides of La\-xAxMnO^ (v4-divalent alkaline earth Ca, Sr or Ba), whose unusual properties were discovered nearly a half century ago, has recently been revived. The discovery of the colossal magnetoresistance and pressure effects introduced new questions concerning the complex interplay between lattice structure, magnetism and transport in doped perovskite manganites. In this study, we report our experimental investigations of pressure and magnetic field dependencies of La-i/sCai/sMnOs (LCMO) epitaxial films with various thickness on SrTiO$ substrate. An analysis of film thickness dependency of the resistivity of LCMO epitaxial films under pressure and magnetic field has been performed by taking into account substrate contributions. This verifies the correlation of lattice distortion with magnetic and transport properties. Strong dependencies of Mn — O — Mn bond bending and Mn — O bond stretching with pressure as well as Mn spin alignment with magnetic field, and the lattice distortion induced by the substrate are discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Since the first offshore Lake Erie well was drilled in 1941, the Grimsby and Thorold formations of the Cataract Group have been economically important to the oil and gas industry of Ontario. The Cataract Group provides a significant amount of Ontario's gas production primarily from wells located on Lake Erie. The Grimsby - Thorold formations are the result of nearshore estuarine processes influenced by tides on a prograding shelf and are composed of subtidal channel complexes, discrete tidal channels, mud flats and non-marine deposits. Deposition was related to a regressive - transgressive cycle associated with eustatic sea level changes caused by the melting and resurgence of continental glaciation centred in Africa in the Late Ordovician/Early Silurian. Grimsby deposition began during a regression with the deposition of subtidal channel complexes incised into the marine deposits of the Cabot Head Formation. The presence of mud drapes and mud couplets suggest that these deposits were influenced by tides. These deposits dominate the lower half of the Grimsby. Deposition continued with a change from these subtidal channel complexes to laterally migrating, discrete, shallow tidal channels and mud flats. These were in turn overlain by the non-marine deposits of the Thorold Formation. Grimsby - Thorold deposition ended with a major transgression replacing siliciclastic deposition with primarily carbonate deposition. Sediment was sourced from the east and southeast and associated with a continuation of the Taconic Orogeny into the Early Silurian. The fluvial head of the estuary prograded from a shoreline that was located in western New York and western Pennsylvania running NNE-SSW and then turning NW-SE and paralleling the present day Lake Erie shoreline. iii The facies attributed to the Grimsby - Thorold formations can be ascribed to the three zones within the tripartite zonation suggested by Dalrymple et ale (1992) for estuaries, that is, a marine-dominated facies, a mixed energy facies, and a facies that is dominated by fluvial processes. Also, sediments within the Grimsby - Thorold are commonly fining upwards sequences which are common in estuarine settings whereas deltaic deposits are normally composed of coarsening upwards sequences in a vertical wedge shape with coarser material near the head. The only coarsening observed was in the Thorold Formation and attributed to non-marine deposition by palynological evidence. The presence of a lag deposit at the base of the sediments of the Grimsby Thorold formations suggests that they were incised into the Cabot Head Formation. Further, the thickness of Early Silurian sediments located between the top of the Queenston Formation, where Early Silurian sedimentation began, to the top of the Reynales - Irondequoit formation are constant whether the Grimsby - Thorold formations are present or not. Also, cross-sections using a sand body located in the Cabot Head Formation for correlation further imply that the Grimsby Formation has been incised into the previous deposits of the Cabot Head.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The vascular adventitia is recognized as a dynamic mediator of vascular structure and function, yet its role in aging is not understood. The purpose of this thesis was to examine the age-related changes of the vascular adventitia and determine the underlying mediators responsible. Male Sprague-Dawley rats were aged to 15, 30, 50 and 80 weeks before being anesthetised and euthanized by exsanguination. Thoracic aortas, mesenteric and pudental arteries were isolated, formalin fixed, and embedded in paraffin then sectioned at 5μm. Vessels were examined by microscopy and protein expression was determined by indirect immunofluorescence. The thickness of the adventitia increased dramatically with age. Immunofluorescence revealed a robust expression of endothelin system proteins in the adventitia. Additionally, extracellular matrix proteins collagen and fibronectin, and the proliferation marker Ki67 showed strong adventitial origin. The changes observed in the vascular adventitia with aging clearly demonstrate an important role in the process of vascular aging.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The vascular adventitia is recognized as a dynamic mediator of vascular structure and function, yet its role in aging is not understood. The purpose of this thesis was to examine the age-related changes of the vascular adventitia and determine the underlying mediators responsible. Male Sprague-Dawley rats were aged to 15,30,50 and 80 weeks before being anesthetised and euthanized by exsanguination. Thoracic aortas, mesenteric and pudental arteries were isolated, formalin fixed, and embedded in paraffin then sectioned at 51lm. Vessels were examined by microscopy and protein expression was determined by indirect immunofluorescence. The thickness of the adventitia increased dramatically with age. Immunofluorescence revealed a robust expression of endothelin system proteins in the adventitia. Additionally, extracellular matrix proteins collagen and fibronectin, and the proliferation marker Ki67 showed strong adventitial origin. The changes observed in the vascular adventitia with aging clearly demonstrate an important role in the process of vascular aging.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

L’augmentation de la population âgée dans la société indique que les systèmes de soins de la santé font face à de nouveaux défis. Les hauts niveaux d’incapacité qui en résultent peuvent être réduits par les nouvelles technologies, la promotion de la santé ainsi que des stratégies de prévention. Les écrits scientifiques récents soulignent la supériorité des prothèses dentaires implanto-portées par rapport aux prothèses conventionnelles en termes de satisfaction et de qualité de la vie des patients. Cependant, il n'est toujours pas clair si ces avantages ont des effets positifs à long terme sur la santé orale et générale ainsi que sur la qualité de vie des populations âgées. Objectifs, Hypothèses : Notre but était de mesurer l’impact des prothèses mandibulaires retenues par 2 implants sur la qualité de vie associée à la santé bucco-dentaire et générale ainsi que sur la santé orale et la qualité du sommeil des aînés édentés. Nous avons évalué les hypothèses nulles suivantes : il n'y a aucune différence entre les individus portants des prothèses mandibulaires retenues par 2 implants (IODs) et ceux qui portent des prothèses conventionnelles (CDs), par rapport à la qualité de vie reliée à la santé bucco-dentaire et générale, la santé orale et la qualité du sommeil, un an après avoir reçu leurs nouvelles prothèses. Méthodes : Dans cette étude randomisée contrôlée, 255 aînés ont reçu au hasard IODs ou les CDs, les deux types de prothèses étant opposés à des prothèses maxillaires conventionnelles. La qualité de la vie reliée à la santé bucco-dentaire (OHRQoL) et la santé générale subjective ont été mesurées avec les questionnaires Oral Health Impact Profile (OHIP-20) et Short Form-36 (SF-36) en condition pré-traitement et après un an. La qualité du sommeil et la somnolence diurne ont été mesurées à l’aide du questionnaire Qualité de Sommeil de Pittsburg et de l'Échelle de Somnolence Epworth. La santé orale a été évaluée par un examen clinique. Les variables indépendantes étaient le sens de cohérence et le type de prosthèse, ainsi que des variables socio-démographiques. En utilisant des analyses statistiques bi et multi-factorielles, des comparaisons à l’intérieur d’un même groupe et entre deux groupes ont été effectuées. Résultats : Les différences pré et post traitement pour les cotes OHIP étaient significativement plus grandes pour le groupe IOD que le groupe CD (p<0.05). Le type de traitement et la cote pré-traitement étaient des facteurs significatifs à OHRQoL (p < 0.0001). Dans le groupe CD, il y avait une diminution significative par rapport aux cotes de «Physical Component Scores (PCS)», le fonctionnement physique, le rôle physique et la douleur physique entre les données pré-traitement et un an après le traitement, ce qui indique une diminution au niveau de la santé générale subjective. Dans le groupe IOD, une diminution statistiquement non significative a été remarquée par rapport à toutes les cotes des sous-échelles de SF-36, sauf pour la douleur physique. Le modèle final de régression a démontré qu’après ajustement pour les variables âge, sexe, statut marital et type de traitement, la cote totale finale d’OHIP et les données de bases de PCS prédisaient la cote finale de PCS (p < 0.0001). Aucune corrélation significative entre sens de cohérence et OHRQoL n'a été détectée (r =-0.1; p > 0.05). Les aînés porteurs des prothèses conventionnelles avaient presque 5 fois plus de chance d’avoir une stomatite prothétique que ceux portant des prothèses mandibulaires hybrides retenues par 2 implants (p < 0.0001). Les aînés ayant subjectivement une mauvaise santé générale avaient une qualité de sommeil moins bonne que ceux avec une meilleure santé générale subjective (p < 0.05). Les personnes qui avaient une OHRQoL moins bonne étaient presque 4 fois plus somnolentes pendant le jour que celles avec une meilleure OHRQoL (p=0.003, χ2; OR =3.8 CI 1.5 to 9.8). L'analyse de régression a montré que la santé générale subjective et OHRQoL prévoient la qualité du sommeil (p=0.022 et p=0.001, respectivement) et la somnolence diurne (p=0.017 et p=0.005, respectivement). Conclusions: Les résultats de cette étude suggèrent que, chez les aînés édentés, des prothèses mandibulaires hybrides retenues par deux implants amènent une amélioration significative de la qualité de vie reliée à la santé bucco-dentaire et maintiennent la sensation d’une meilleure santé physique. Des prothèses hybrides implanto-portées peuvent contribuer à la santé orale en réduisant les traumatismes infligés à la muqueuse orale et en contrôlant la stomatite prothétique. Les aînés édentés dont le niveau de qualité de vie reliée à la santé bucco-dentaire est bas, peuvent aussi avoir des troubles de qualité du sommeil.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Justification: Le glaucome entraîne une perte progressive de la vision causée par la détérioration du nerf optique. Le glaucome est répandu dans le monde et cause la cécité dans environ sept millions de personnes. Le glaucome touche plus de 400 000 Canadiens et sa prévalence augmente avec le vieillissement de la population.1,2 Il s'agit d'une maladie chronique surnoise dont les symptômes se manifestent uniquement lors des stades avancés et qui peuvent mener à la cécité. Présentement, le seul moyen possible d’arrêter la progression du glaucome au stade initial est de diminuer la pression intra-oculaire (PIO). Les analogues de prostaglandines (APG) topiques sont fréquemment utilisées comme traitement de première ligne. Cependant, la recherche démontre que cette classe de médicaments peut changer certaines propriétés de la cornée, et possiblement influencer la mesure de la PIO.3 Objectif: À déterminer si l'utilisation d'APG affecte les propriétés biomécaniques de la cornée. La conclusion sera basée sur l'analyse intégrée des résultats obtenus de l'analyseur Reichert oculaire Réponse (ORA), la tonométrie par applanation de Goldmann (TAG) et la pachymétrie ultrasonographique. Le deuxième objectif potentiel de cette étude est de déterminer la corrélation, le cas échéant, entre les propriétés biomécaniques de la cornée, l'épaisseur de la cornée centrale (ECC) et la PIO chez les patients subissant un traitement d’APG topique. L'hypothèse principale de cette étude est que l’APG influence les propriétés de la cornée telles que l'épaisseur centrale, l'élasticité et la résistance. Patients et méthodes : Soixante-dix yeux de 35 patients, âgés de 50-85 ans, atteints de glaucome à angle ouvert (GAO) et traités avec APG topique ont été examinés. Seulement les sujets avec une réfraction manifeste entre -6,00 D et +4,25 D ont été inclus. Les critères d'exclusion sont: patients avec n'importe quelle autre maladie de la cornée de l’œil, telles que la dystrophie endothéliale de Fuch’s et kératocône, ou tout antécédent de traumatisme ou d'une chirurgie de la cornée, ainsi que le port de lentilles de contact. Nous avons demandé aux patients atteints du glaucome qui ont des paramètres stables et qui utilisent l’APG dans les deux yeux de cesser l’APG dans l'œil moins affecté par la PIO, et de continuer l’utilisation d’APG dans l'œil contralatéral. Le meilleur œil est défini comme celui avec moins de dommage sur le champ visuel (CV) (déviation moyenne (DM), le moins négatif) ou une PIO maximale historique plus basse si la DM est égale ou encore celui avec plus de dommage sur la tomographie par cohérence optique (TCO, Cirrus, CA) ou la tomographie confocale par balayage laser (HRT, Heidelberg, Allemagne). Toutes les mesures ont été prises avant la cessation d’APG et répétées 6 semaines après l’arrêt. Les patients ont ensuite recommencé l’utilisation d’APG et toutes les mesures ont été répétées encore une fois après une période supplémentaire de 6 semaines. Après commencer ou de changer le traitement du glaucome, le patient doit être vu environ 4-6 semaines plus tard pour évaluer l'efficacité de la goutte.4 Pour cette raison, on été décidé d'utiliser 6 semaines d'intervalle. Toutes les mesures ont été effectuées à l’institut du glaucome de Montréal par le même technicien, avec le même équipement et à la même heure de la journée. L'œil contralatéral a servi comme œil contrôle pour les analyses statistiques. La tonométrie par applanation de Goldmann a été utilisée pour mesurer la PIO, la pachymétrie ultrasonographique pour mesurer l'ECC, et l’ORA pour mesurer les propriétés biomécaniques de la cornée, incluant l'hystérèse cornéenne (HC). L’hypothèse de l'absence d'effet de l'arrêt de l’APG sur les propriétés biomécaniques a été examiné par un modèle linéaire à effets mixtes en utilisant le logiciel statistique R. Les effets aléatoires ont été définies à deux niveaux: le patient (niveau 1) et l'œil de chaque patient (niveau 2). Les effets aléatoires ont été ajoutés au modèle pour tenir compte de la variance intra-individuelle. L’âge a également été inclus dans le modèle comme variable. Les contrastes entre les yeux et les temps ont été estimés en utilisant les valeurs p ajustées pour contrôler les taux d'erreur internes de la famille en utilisant multcomp paquet dans R. Résultats: Une augmentation statistiquement significative due l 'HC a été trouvée entre les visites 1 (sur APG) et 2 (aucun APG) dans les yeux de l'étude, avec une moyenne (±erreur standard) des valeurs de 8,98 ± 0,29 mmHg et 10,35 ± 0,29 mmHg, respectivement, correspondant à une augmentation moyenne de 1,37 ± 0,18 mmHg (p <0,001). Une réduction significative de 1,25 ± 0,18 mmHg (p <0,001) a été observée entre les visites 2 et 3, avec une valeur moyenne HC finale de 9,09 ± 0,29 mmHg. En outre, une différence statistiquement significative entre l’oeil d’étude et le contrôle n'a été observée que lors de la visite 2 (1,01 ± 0,23 mmHg, p <0,001) et non lors des visites 1 et 3. Une augmentation statistiquement significative du facteur de résistance conréen (FRC) a été trouvée entre les visites 1 et 2 dans les yeux de l'étude, avec des valeurs moyennes de 10,23 ± 0,34 mmHg et 11,71 ± 0,34 mmHg, respectivement. Le FRC a ensuite été réduit de 1,90 ± 0,21 mmHg (p <0,001) entre les visites 2 et 3, avec une valeur moyenne FRC finale de 9,81 ± 0,34 mmHg. Une différence statistiquement significative entre l’oeil d’étude et le contrôle n'a été observée que lors de la visite 2 (1,46 ± 0,23 mmHg, p <0,001). Une augmentation statistiquement significative de l'ECC a été trouvée entre les visites 1 et 2 dans les yeux de l'étude, avec des valeurs moyennes de 541,83 ± 7,27 µm et 551,91 ± 7,27 µm, respectivement, ce qui correspond à une augmentation moyenne de 10,09 ± 0,94 µm (p <0,001). L'ECC a ensuite diminué de 9,40 ± 0,94 µm (p <0,001) entre les visites 2 et 3, avec une valeur moyenne finale de 542,51 ± 7,27 µm. Une différence entre l’étude et le contrôle des yeux n'a été enregistré que lors de la visite 2 (11,26 ± 1,79 µm, p <0,001). De même, on a observé une augmentation significative de la PIO entre les visites 1 et 2 dans les yeux de l'étude, avec des valeurs moyennes de 15,37 ± 0,54 mmHg et 18,37 ± 0,54 mmHg, respectivement, ce qui correspond à une augmentation moyenne de 3,0 ± 0,49 mmHg (p <0,001). Une réduction significative de 2,83 ± 0,49 mmHg (p <0,001) a été observée entre les visites 2 et 3, avec une valeur moyenne de la PIO finale de 15,54 ± 0,54 mmHg. L’oeil de contrôle et d’étude ne différaient que lors de la visite 2 (1,91 ± 0,49 mmHg, p <0,001), ce qui confirme l'efficacité du traitement de l’APG. Lors de la visite 1, le biais de la PIO (PIOcc - PIO Goldmann) était similaire dans les deux groupes avec des valeurs moyennes de 4,1 ± 0,54 mmHg dans les yeux de contrôles et de 4,8 ± 0,54 mmHg dans les yeux d’études. Lors de la visite 2, après un lavage de 6 semaines d’APG, le biais de la PIO dans l'œil testé a été réduit à 1,6 ± 0,54 mmHg (p <0,001), ce qui signifie que la sous-estimation de la PIO par TAG était significativement moins dans la visite 2 que de la visite 1. La différence en biais PIO moyenne entre l'étude et le contrôle des yeux lors de la visite 2, en revanche, n'a pas atteint la signification statistique (p = 0,124). On a observé une augmentation peu significative de 1,53 ± 0,60 mmHg (p = 0,055) entre les visites 2 et 3 dans les yeux de l'étude, avec une valeur de polarisation finale de la PIO moyenne de 3,10 ± 0,54 mmHg dans les yeux d'études et de 2,8 ± 0,54 mmHg dans les yeux de contrôles. Nous avons ensuite cherché à déterminer si une faible HC a été associée à un stade de glaucome plus avancé chez nos patients atteints du glaucome à angle ouvert traités avec l’APG. Lorsque l'on considère tous les yeux sur l’APG au moment de la première visite, aucune association n'a été trouvée entre les dommages sur le CV et l'HC. Cependant, si l'on considère seulement les yeux avec un glaucome plus avancé, une corrélation positive significative a été observée entre la DM et l'HC (B = 0,65, p = 0,003). Une HC inférieure a été associé à une valeur de DM de champ visuelle plus négative et donc plus de dommages liés au glaucome. Conclusions : Les prostaglandines topiques affectent les propriétés biomécaniques de la cornée. Ils réduisent l'hystérèse cornéenne, le facteur de résistance cornéen et l'épaisseur centrale de la cornée. On doit tenir compte de ces changements lors de l'évaluation des effets d’APG sur la PIO. Plus de recherche devrait être menées pour confirmer nos résultats. De plus, d’autres études pourraient être réalisées en utilisant des médicaments qui diminuent la PIO sans influencer les propriétés biomécaniques de la cornée ou à l'aide de tonomètre dynamique de Pascal ou similaire qui ne dépend pas des propriétés biomécaniques de la cornée. En ce qui concerne l'interaction entre les dommages de glaucome et l'hystérésis de la cornée, nous pouvons conclure qu' une HC inférieure a été associé à une valeur de DM de CV plus négative. Mots Clés glaucome - analogues de prostaglandines - hystérèse cornéenne – l’épaisseur de la cornée centrale - la pression intraoculaire - propriétés biomécaniques de la cornée.