921 resultados para Systemic antibodies


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Prostate Specific Antigen (PSA) is the biomarker of choice for screening prostate cancer throughout the population, with PSA values above 10 ng/mL pointing out a high probability of associated cancer1. According to the most recent World Health Organization (WHO) data, prostate cancer is the commonest form of cancer in men in Europe2. Early detection of prostate cancer is thus very important and is currently made by screening PSA in men over 45 years old, combined with other alterations in serum and urine parameters. PSA is a glycoprotein with a molecular mass of approximately 32 kDa consisting of one polypeptide chain, which is produced by the secretory epithelium of human prostate. Currently, the standard methods available for PSA screening are immunoassays like Enzyme-Linked Immunoabsorbent Assay (ELISA). These methods are highly sensitive and specific for the detection of PSA, but they require expensive laboratory facilities and high qualify personal resources. Other highly sensitive and specific methods for the detection of PSA have also become available and are in its majority immunobiosensors1,3-5, relying on antibodies. Less expensive methods producing quicker responses are thus needed, which may be achieved by synthesizing artificial antibodies by means of molecular imprinting techniques. These should also be coupled to simple and low cost devices, such as those of the potentiometric kind, one approach that has been proven successful6. Potentiometric sensors offer the advantage of selectivity and portability for use in point-of-care and have been widely recognized as potential analytical tools in this field. The inherent method is simple, precise, accurate and inexpensive regarding reagent consumption and equipment involved. Thus, this work proposes a new plastic antibody for PSA, designed over the surface of graphene layers extracted from graphite. Charged monomers were used to enable an oriented tailoring of the PSA rebinding sites. Uncharged monomers were used as control. These materials were used as ionophores in conventional solid-contact graphite electrodes. The obtained results showed that the imprinted materials displayed a selective response to PSA. The electrodes with charged monomers showed a more stable and sensitive response, with an average slope of -44.2 mV/decade and a detection limit of 5.8X10-11 mol/L (2 ng/mL). The corresponding non-imprinted sensors showed smaller sensitivity, with average slopes of -24.8 mV/decade. The best sensors were successfully applied to the analysis of serum samples, with percentage recoveries of 106.5% and relatives errors of 6.5%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Human chorionic gonadotropin (hCG) is a key diagnostic marker of pregnancy and an important biomarker for cancers in the prostate, ovaries and bladder and therefore of great importance in diagnosis. For this purpose, a new immunosensor of screen-printed electrodes (SPEs) is presented here. The device was fabricated by introducing a polyaniline (PANI) conductive layer, via in situ electropolymerization of aniline, onto a screen-printed graphene support. The PANI-coated graphene acts as the working electrode of a three terminal electrochemical sensor. The working electrode is functionalised with anti-hCG, by means of a simple process that enabled oriented antibody binding to the PANI layer. The antibody was attached to PANI following activation of the –COOH group at the Fc terminal. Functionalisation of the electrode was analysed and optimized using Electrochemical Impedance Spectroscopy (EIS). Chemical modification of the surface was characterised using Fourier transform infrared, and Raman spectroscopy with confocal microscopy. The graphene–SPE–PANI devices displayed linear responses to hCG in EIS assays from 0.001 to 50 ng mL−1 in real urine, with a detection limit of 0.286 pg mL−1. High selectivity was observed with respect to the presence of the constituent components of urine (urea, creatinine, magnesium chloride, calcium chloride, sodium dihydrogen phosphate, ammonium chloride, potassium sulphate and sodium chloride) at their normal levels, with a negligible sensor response to these chemicals. Successful detection of hCG was also achieved in spiked samples of real urine from a pregnant woman. The immunosensor developed is a promising tool for point-of-care detection of hCG, due to its excellent detection capability, simplicity of fabrication, low-cost, high sensitivity and selectivity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Increased levels of plasma oxLDL, which is the oxidized fraction of Low Density Lipoprotein (LDL), are associated with atherosclerosis, an inflammatory disease, and the subsequent development of severe cardiovascular diseases that are today a major cause of death in modern countries. It is therefore important to find a reliable and fast assay to determine oxLDL in serum. A new immunosensor employing three monoclonal antibodies (mAbs) against oxLDL is proposed in this work as a quick and effective way to monitor oxLDL. The oxLDL was first employed to produce anti-oxLDL monoclonal antibodies by hybridoma cells that were previously obtained. The immunosensor was set-up by selfassembling cysteamine (Cyst) on a gold (Au) layer (4 mm diameter) of a disposable screen-printed electrode. Three mAbs were allowed to react with N-hydroxysuccinimide (NHS) and ethyl(dimethylaminopropyl)carbodiimide (EDAC), and subsequently incubated in the Au/Cys. Albumin from bovine serum (BSA) was immobilized further to ensure that other molecules apart from oxLDL could not bind to the electrode surface. All steps were followed by various characterization techniques such as electrochemical impedance spectroscopy (EIS) and square wave voltammetry (SWV). The analytical operation of the immunosensor was obtained by incubating the sensing layer of the device in oxLDL for 15 minutes, prior to EIS and SWV. This was done by using standard oxLDL solutions prepared in foetal calf serum, in order to simulate patient's plasma with circulating oxLDL. A sensitive response was observed from 0.5 to 18.0 mg mL 1 . The device was successfully applied to determine the oxLDL fraction in real serum, without prior dilution or necessary chemical treatment. The use of multiple monoclonal antibodies on a biosensing platform seemed to be a successful approach to produce a specific response towards a complex multi-analyte target, correlating well with the level of oxLDL within atherosclerosis disease, in a simple, fast and cheap way.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A gold screen printed electrode (Au-SPE) was modified by merging Molecular Imprinting and Self-Assembly Monolayer techniques for fast screening cardiac biomarkers in point-of-care (POC). For this purpose, Myoglobin (Myo) was selected as target analyte and its plastic antibody imprinted over a glutaraldehyde (Glu)/cysteamine (Cys) layer on the gold-surface. The imprinting effect was produced by growing a reticulated polymer of acrylamide (AAM) and N,N′-methylenebisacrylamide (NNMBA) around the Myo template, covalently attached to the biosensing surface. Electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) studies were carried out in all chemical modification steps to confirm the surface changes in the Au-SPE. The analytical features of the resulting biosensor were studied by different electrochemical techniques, including EIS, square wave voltammetry (SWV) and potentiometry. The limits of detection ranged from 0.13 to 8 μg/mL. Only potentiometry assays showed limits of detection including the cut-off Myo levels. Quantitative information was also produced for Myo concentrations ≥0.2 μg/mL. The linear response of the biosensing device showed an anionic slope of ~70 mV per decade molar concentration up to 0.3 μg/mL. The interference of coexisting species was tested and good selectivity was observed. The biosensor was successfully applied to biological fluids.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Using low cost portable devices that enable a single analytical step for screening environmental contaminants is today a demanding issue. This concept is here tried out by recycling screen-printed electrodes that were to be disposed of and by choosing as sensory element a low cost material offering specific response for an environmental contaminant. Microcystins (MCs) were used as target analyte, for being dangerous toxins produced by cyanobacteria released into water bodies. The sensory element was a plastic antibody designed by surface imprinting with carefully selected monomers to ensure a specific response. These were designed on the wall of carbon nanotubes, taking advantage of their exceptional electrical properties. The stereochemical ability of the sensory material to detect MCs was checked by preparing blank materials where the imprinting stage was made without the template molecule. The novel sensory material for MCs was introduced in a polymeric matrix and evaluated against potentiometric measurements. Nernstian response was observed from 7.24 × 10−10 to 1.28 × 10−9 M in buffer solution (10 mM HEPES, 150 mM NaCl, pH 6.6), with average slopes of −62 mVdecade−1 and detection capabilities below 1 nM. The blank materials were unable to provide a linear response against log(concentration), showing only a slight potential change towards more positive potentials with increasing concentrations (while that ofthe plastic antibodies moved to more negative values), with a maximum rate of +33 mVdecade−1. The sensors presented good selectivity towards sulphate, iron and ammonium ions, and also chloroform and tetrachloroethylene (TCE) and fast response (<20 s). This concept was successfully tested on the analysis of spiked environmental water samples. The sensors were further applied onto recycled chips, comprehending one site for the reference electrode and two sites for different selective membranes, in a biparametric approach for “in situ” analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel artificial antibody for troponin T (TnT) was synthesized by molecular imprint (MI) on the surface of multiwalled carbon nanotubes (MWCNT). This was done by attaching TnT to the MWCNT surface, and filling the vacant spaces by polymerizing under mild conditions acrylamide (monomer) in N,N′-methylenebisacrylamide (cross-linker) and ammonium persulphate (initiator). After removing the template, the obtained biomaterial was able to rebind TnT and discriminate it among other interfering species. Stereochemical recognition of TnT was confirmed by the non-rebinding ability displayed by non-imprinted (NI) materials, obtained by imprinting without a template. SEM and FTIR analysis confirmed the surface modification of the MWCNT. The ability of this biomaterial to rebind TnT was confirmed by including it as electroactive compound in a PVC/plasticizer mixture coating a wire of silver, gold or titanium. Anionic slopes of 50 mV decade−1 were obtained for the gold wire coated with MI-based membranes dipped in HEPES buffer of pH 7. The limit of detection was 0.16 μg mL−1. Neither the NI-MWCNT nor the MWCNT showed the ability to recognize the template. Good selectivity was observed against creatinine, sucrose, fructose, myoglobin, sodium glutamate, thiamine and urea. The sensor was tested successfully on serum samples. It is expected that this work opens new horizons on the design of new artificial antibodies for complex protein structures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Monitoring organic environmental contaminants is of crucial importance to ensure public health. This requires simple, portable and robust devices to carry out on-site analysis. For this purpose, a low-temperature co-fired ceramics (LTCC) microfluidic potentiometric device (LTCC/μPOT) was developed for the first time for an organic compound: sulfamethoxazole (SMX). Sensory materials relied on newly designed plastic antibodies. Sol–gel, self-assembling monolayer and molecular-imprinting techniques were merged for this purpose. Silica beads were amine-modified and linked to SMX via glutaraldehyde modification. Condensation polymerization was conducted around SMX to fill the vacant spaces. SMX was removed after, leaving behind imprinted sites of complementary shape. The obtained particles were used as ionophores in plasticized PVC membranes. The most suitable membrane composition was selected in steady-state assays. Its suitability to flow analysis was verified in flow-injection studies with regular tubular electrodes. The LTCC/μPOT device integrated a bidimensional mixer, an embedded reference electrode based on Ag/AgCl and an Ag-based contact screen-printed under a micromachined cavity of 600 μm depth. The sensing membranes were deposited over this contact and acted as indicating electrodes. Under optimum conditions, the SMX sensor displayed slopes of about −58.7 mV/decade in a range from 12.7 to 250 μg/mL, providing a detection limit of 3.85 μg/mL and a sampling throughput of 36 samples/h with a reagent consumption of 3.3 mL per sample. The system was adjusted later to multiple analyte detection by including a second potentiometric cell on the LTCC/μPOT device. No additional reference electrode was required. This concept was applied to Trimethoprim (TMP), always administered concomitantly with sulphonamide drugs, and tested in fish-farming waters. The biparametric microanalyzer displayed Nernstian behaviour, with average slopes −54.7 (SMX) and +57.8 (TMP) mV/decade. To demonstrate the microanalyzer capabilities for real applications, it was successfully applied to single and simultaneous determination of SMX and TMP in aquaculture waters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A 5-year-old female developed, after a 7-month period of fever, anorexia, weight loss, and a transitory cutaneous erythematous eruption, a severe acute transverse myelopathy, with a partial recovery of motor and sensory function. She had positive antinuclear and antidouble-stranded DNA antibodies but no antiphospholipid antibodies. Six months later she had massive proteinuria and restarted treatment with steroids and cyclophosphamide. Our patient is one of the youngest reported with lupus myelopathy. We discuss the clinical presentation, the magnetic resonance imaging findings, and other relevant laboratory studies of this rare but serious complication of systemic lupus erythematosus.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Erectile dysfunction (ED) is a prevalent complication of diabetes, and oxidative stress is an important feature of diabetic ED. Oxidative stress-induced damage plays a pivotal role in the development of tissue alterations. However, the deleterious effects of oxidative stress in the corpus cavernosum with the progression of diabetes remain unclear. The aim of this study was to evaluate systemic and penile oxidative stress status in the early and late stages of diabetes. Methods Male Wistar streptozotocin-diabetic rats (and age-matched controls) were examined 2 (early) and 8 weeks (late) after the induction of diabetes. Systemic oxidative stress was evaluated by urinary H2O2 and the ratio of circulating reduced/oxidized glutathione (GSH/GSSG). Penile oxidative status was assessed by H2O2 production and 3-nitrotyrosine (3-NT) formation. Cavernosal endothelial nitric oxide synthase (eNOS) was analyzed by quantitative immunohistochemistry. Dual immunofluorescence was also performed for 3-NT and α-smooth muscle actin (α-SMA) and eNOS–α-SMA. Results There was a significant increase in urinary H2O2 levels in both diabetic groups. The plasma GSH/GSSG ratio was significantly augmented in late diabetes. In cavernosal tissue, H2O2 production was significantly increased in late diabetes. Reactivity for 3-NT was located predominantly in cavernosal smooth muscle (SM) and was significantly reduced in late diabetes. Quantitative immunohistochemistry revealed a significant decrease in eNOS levels in cavernosal SM and endothelium in late diabetes. Conclusions The findings indicate that the noxious effects of oxidative stress are more prominent in late diabetes. Increased penile protein oxidative modifications and decreased eNOS expression may be responsible for structural and/or functional deregulation, contributing to the progression of diabetes-associated ED.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This retrospective study was designed to evaluate the outcome of pregnancies in women diagnosed with systemic lupus erythematosus (SLE) followed in a tertiary fetal–maternal center. Data were collected from clinical charts between January 1993 and December 2007, with a total of 136 pregnancies (107 patients). Mean maternal age was 29 years, with the vast majority of patients being Caucasian. Most patients were in remission 6 months prior to pregnancy (93%) and the most frequently affected organs were the skin and joints. Renal lupus accounted for 14% of all cases. Twenty-nine percent of patients were positive for at least one antiphospholid antibody (aPL) and nearly 50% had positive SSa/SSb antibodies. All patients with positive aPL received low-dosage aspirin and low molecular- weight heparin (LMWH). There were no pregnancy complications in more than 50% of cases and hypertensive disease and intrauterine growth restriction were the most common adverse events. There were 125 live births, one neonatal death, eight miscarriages, and three medical terminations of pregnancy. Preterm delivery occurred in 25% of pregnancies. Our results are probably the conjoined result of a multidisciplinary approach together with a systematic management of SLE pregnancies, with most patients keeping their prior SLE medication combined with low-dosage aspirin and LMWH in the presence of aPL.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introdução e Objectivo: A presença de anticorpos antifosfolípidos (AAF) está associada a perdas embrionárias e fetais e a outras complicações obstétricas como pré-eclâmpsia, restrição de crescimento intra-uterino e parto pré-termo. Os doentes com lúpus eritematoso sistémico (LES) com frequência possuem AAF e síndroma antifosfolípidica (SAAF) secundária. O objectivo deste estudo é avaliar comparativamente o prognóstico da gravidez em mulheres com LES na presença e na ausência de AAF. Material e Métodos:Avaliação retrospectiva de 136 gestações em mulheres com diagnóstico prévio de LES cujo seguimento foi realizado na nossa instituição entre 1993 e 2007. As grávidas com e sem AAF foram consideradas separadamente. Dados relativos a idade materna, história obstétrica passada, actividade do LES no início da gravidez, existência de nefropatia, evolução da gravidez actual, idade gestacional no parto, tipo de parto, peso do recém-nascido e a existência de complicações hipertensivas na gravidez foram analisados. Resultados: 28% (38) das grávidas com LES apresentavam AAF. Deste grupo, 28,9% tinham história de perdas fetais do segundo e/ou terceiro trimestre, em oposição a 6,12% nas doentes sem AAF(p<0,05). A avaliação da actual gravidez demonstrou uma taxa de insucesso na gravidez significativamente mais elevada na população com AAF(8,1% versus 2,1%, p<0,05). Não se verificaram diferenças significativas no peso médio do recém-nascido e na taxa de restrição intra-uterina em função da presença de AAF. A idade gestacional media no parto foi de 36,9 semanas em ambos os grupos com uma taxa idêntica de parto pré-termo. O parto ocorreu por cesariana em 47% das doentes com AAF e em 44,1% das doentes sem AAF. Conclusões:Os antecedentes obstétricos de perda fetal do 2º e 3º trimestre e a probabilidade de aborto espontâneo são mais frequentes em grávidas com LES e AAF. Nos restantes parâmetros analisados não se verificaram diferenças significativas em função da presença de AAF.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This is a case report of a 43-year-old Caucasian male with end-stage renal disease being treated with hemodialysis and infective endocarditis in the aortic and tricuspid valves. The clinical presentation was dominated by neurologic impairment with cerebral embolism and hemorrhagic components. A thoracoabdominal computerized tomography scan revealed septic pulmonary embolus. The patient underwent empirical antibiotherapy with ceftriaxone, gentamicin and vancomycin, and the therapy was changed to flucloxacilin and gentamicin after the isolation of S. aureus in blood cultures. The multidisciplinary team determined that the patient should undergo valve replacement after the stabilization of the intracranial hemorrhage; however, on the 8th day of hospitalization, the patient entered cardiac arrest due to a massive septic pulmonary embolism and died. Despite the risk of aggravation of the hemorrhagic cerebral lesion, early surgical intervention should be considered in high-risk patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Marginal Expected Shortfall (MES) is an approach used to measure the systemic risk financial institutions face. It estimates how significantly systemic events (poor market performance, out of 1.6 times Standard Deviation borders) are expected to affect market capitalization of a particular firm. The concept was developed in the late 2000s and is widely used for cross-country comparisons of financial firms. For the purposes of generalization of this technique it is often used with market data containing non-domestic currencies for some financial firms. That may lead to results having currency noise in them as it is shown for 77 UK financial firms in our analysis between 2001 and 2014.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Heme, i.e. iron (Fe) protoporphyrin IX, functions as a prosthetic group in a variety of hemoproteins that participate in vital biologic functions essential to sustain life. Heme is a highly reactive molecule, participating in redox reactions, and presumably for this reason it must be sequestered within the heme pockets of hemoproteins, controlling its reactivity. However, under biological stress conditions, hemoproteins can release their prosthetic groups, generating “free heme”, which binds loosely to proteins or to other molecules and presumably acquires unfettered redox activity. Moreover, a growing body of evidence supports the notion that “free heme” can act in a vasoactive, pro-inflammatory and cytotoxic manner when released from a subset of these hemoproteins, such as extracellular hemoglobin, generated during hemolytic conditions. (...)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Business ethicists often assume that unethical behavior arises when individuals deviate from the norms and responsibilities that are institutionalized to frame economic activities. People's greed motivates them to violate the rules of the game. In Kohlberg's terms, it is assumed that such actors make decisions in a preconventional way and act opportunistically. In this article, we propose an alternative interpretation of deviant behavior, arguing that such behavior does not result from a lack of conventional moral guidance but rather from the fact that characteristics attributed to preconventional morality by Kohlberg - the purely incentive and punishment driven opportunistic morality - have become the conventionalized morality. The prevailing norms that economic actors have internalized as their yardstick are those of the preconventional Homo economicus. Not the deviation from, but the compliance with the rules of the game explains many forms of harmful and illegal decisions made in corporations.