978 resultados para Storage stability


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In-network storage of data in wireless sensor networks contributes to reduce the communications inside the network and to favor data aggregation. In this paper, we consider the use of n out of m codes and data dispersal in combination to in-network storage. In particular, we provide an abstract model of in-network storage to show how n out of m codes can be used, and we discuss how this can be achieved in five cases of study. We also define a model aimed at evaluating the probability of correct data encoding and decoding, we exploit this model and simulations to show how, in the cases of study, the parameters of the n out of m codes and the network should be configured in order to achieve correct data coding and decoding with high probability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Demo in Workshop on ns-3 (WNS3 2015). 13 to 14, May, 2015. Castelldefels, Spain.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Container Loading Problem (CLP) literature has traditionally evaluated the dynamic stability of cargo by applying two metrics to box arrangements: the mean number of boxes supporting the items excluding those placed directly on the floor (M1) and the percentage of boxes with insufficient lateral support (M2). However, these metrics, that aim to be proxies for cargo stability during transportation, fail to translate real-world cargo conditions of dynamic stability. In this paper two new performance indicators are proposed to evaluate the dynamic stability of cargo arrangements: the number of fallen boxes (NFB) and the number of boxes within the Damage Boundary Curve fragility test (NB_DBC). Using 1500 solutions for well-known problem instances found in the literature, these new performance indicators are evaluated using a physics simulation tool (StableCargo), replacing the real-world transportation by a truck with a simulation of the dynamic behaviour of container loading arrangements. Two new dynamic stability metrics that can be integrated within any container loading algorithm are also proposed. The metrics are analytical models of the proposed stability performance indicators, computed by multiple linear regression. Pearson’s r correlation coefficient was used as an evaluation parameter for the performance of the models. The extensive computational results show that the proposed metrics are better proxies for dynamic stability in the CLP than the previous widely used metrics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Context: Inclusion of antioxidants in topical formulations can contribute to minimize oxidative stress in the skin, which has been associated with photoaging, several dermatosis and cancer. Objective: A Castanea sativa leaf extract with established antioxidant activity was incorporated into a semisolid surfactant-free formulation. The objective of this study was to perform a comprehensive characterization of this formulation. Materials and methods: Physical, microbiological and functional stability were evaluated during 6 months storage at 20 °C and 40 °C. Microstructure elucidation (cryo-SEM), in vitro release and in vivo moisturizing effect (Corneometer® CM 825) were also assessed. Results and discussion: Minor changes were observed in the textural and rheological properties of the formulation when stored at 20 °C for 6 months and the antioxidant activity of the plant extract remained constant throughout the storage period. Microbiological quality was confirmed at the end of the study. Under accelerated conditions, higher modifications of the evaluated parameters were observed. Cryo-SEM analysis revealed the presence of oil droplets dispersed into a gelified external phase. The release rate of the antioxidant compounds (610 ± 70 µgh−0.5) followed Higuchi model. A significant in vivo moisturizing effect was demonstrated, that lasted at least 4 h after product’s application. Conclusion: The physical, functional and microbiological stability of the antioxidant formulation was established. Specific storage conditions should be recommended considering the influence of temperature on the stability. A skin hydration effect and good skin tolerance were also found which suggests that this preparation can be useful in the prevention or treatment of oxidative stress-mediated dysfunctions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The integration of wind power in eletricity generation brings new challenges to unit commitment due to the random nature of wind speed. For this particular optimisation problem, wind uncertainty has been handled in practice by means of conservative stochastic scenario-based optimisation models, or through additional operating reserve settings. However, generation companies may have different attitudes towards operating costs, load curtailment, or waste of wind energy, when considering the risk caused by wind power variability. Therefore, alternative and possibly more adequate approaches should be explored. This work is divided in two main parts. Firstly we survey the main formulations presented in the literature for the integration of wind power in the unit commitment problem (UCP) and present an alternative model for the wind-thermal unit commitment. We make use of the utility theory concepts to develop a multi-criteria stochastic model. The objectives considered are the minimisation of costs, load curtailment and waste of wind energy. Those are represented by individual utility functions and aggregated in a single additive utility function. This last function is adequately linearised leading to a mixed-integer linear program (MILP) model that can be tackled by general-purpose solvers in order to find the most preferred solution. In the second part we discuss the integration of pumped-storage hydro (PSH) units in the UCP with large wind penetration. Those units can provide extra flexibility by using wind energy to pump and store water in the form of potential energy that can be generated after during peak load periods. PSH units are added to the first model, yielding a MILP model with wind-hydro-thermal coordination. Results showed that the proposed methodology is able to reflect the risk profiles of decision makers for both models. By including PSH units, the results are significantly improved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Doutor em Engenharia Química e Bioquímica

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertation to obtain a Master Degree in Biotechnology

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertation presented to obtain the PhD degree in Biochemistry

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper reports on the findings of a survey on OCI storage in people in Bahia, Brasil. In this survey 11 samples of adipose tissue were taken from people who underwent splenectomy for hepato splenic schistosomiasis. In these patients, total DDT averaged 10.66 ppm as compared to 4,83 ppm of total DDT found in presumably healthy people. The difference was statistically significant. It is considered that the increased DDT storage in patients with hepatosplenic schistosomiass may be the result of a reduced metabolzation of p,p'-DDT and reduced excretion of its metabolites. Another possíbility is the increased exposure to organochlorine nsectedes by hepatosplenc patients who frequently come from irrigation zones, where these compounds are more used in intensive cultivatíon.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertation to obtain the Doctoral degree in Physics Engineering

Relevância:

20.00% 20.00%

Publicador:

Resumo:

21st Annual Conference of the International Group for Lean Construction – IGLC 21 – Fortaleza, Brazil

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A Work Project, presented as part of the requirements for the Award of a Masters Degree in Management from the NOVA – School of Business and Economics

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertation presented to Faculdade de Ciências e Tecnologia, Universidade Nova de Lisboa for obtaining the master degree in Membrane Engineering

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Four years after the first visit seventeen public health units were visited again and evaluated as to standards of storage recommended by the Brazilian Immunization Programme. In 100% of the units, refrigerators and proper inside location of vaccines in the refrigerator were adequatety or regularfy maintained and checked, respectively. However, when control of temperature was checked, onfy 64.7% presented adequate storage conditions. In 94.1 % of the units, health workers complained of lack of immediate technical support in emergency situations. In 55.2 % the titers vaccine samples of were under the minimal recommended potency. It is necessary that the factors concerning the cold chain be continualfy evaluated so that the quality of the vaccines that will be used is not affected.