989 resultados para SCREENING ACCURACY


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Erythrovirus B19 infection is usually benign but may have serious consequences in patients with hemolytic anemia (transient aplastic crisis), immunodeficiency (in whom persistent infection can lead to chronic bone marrow failure with anemia), or who are in the first or second trimester of gestation (spontaneous abortion, hydrops fetalis, and fetal death). Being non-enveloped, B19 resists most inactivation methods and can be transmitted by transfusion. B19 is difficult to cultivate and native virus is usually obtained from viremic blood. As specific antibodies may be absent, and there is no reliable immunological method for antigen detection, hybridization or polymerase chain reaction are needed for detecting viremia. A rapid method, gel hemagglutination (Diamed ID-Parvovirus B19 Antigen Test), can disclose highly viremic donations, whose elimination lessens the viral burden in pooled blood products and may even render them non-infectious. In order to obtain native antigen and to determine the frequency of viremic donors, we applied this test to blood donors in a period of high viral activity in our community. Positive or indeterminate results were re-tested by dot-blot hybridization. We tested 472 donors in 1998 and 831 ones in 1999. One viremic donor was found in 1999. We suggest that in periods of high community viral activity the gel hemagglutination test may be useful in avoiding highly viremic blood being added to plasma pools or directly transfused to patients under risk.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This flyer has been produced to help maximise awareness of the abdominal aortic aneurysm (AAA) screening programme in Northern Ireland. It provides important information on AAAs, the danger they pose to the health of men aged 65 and over, and the screening process. The flyers will be distributed to eligible men through the following channels, among others: public events, eg talks with men's groups, Farm Families Health Checks programme;health information stands in shopping centres, supermarkets etc;GP practices;pharmacies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background:Congenital hypogonadotropic hypogonadism (HH), a rare disorder characterized by absent, partial, or delayed puberty, can be caused by the lack or deficient number of hypothalamic gonadotropin-releasing hormone (GnRH) neurons. SEMA3A was recently implicated in the etiology of the disorder, and Sema7A-deficient mice have a reduced number of GnRH neurons in their brains.Methods:SEMA3A and SEMA7A were screened by Sanger sequencing in altogether 50 Finnish HH patients (34 with Kallmann syndrome (KS; HH with hyposmia/anosmia) and 16 with normosmic HH (nHH)). In 20 patients, mutation(s) had already been found in genes known to be implicated in congenital HH.Results:Three heterozygous variants (c.458A>G (p.Asn153Ser), c.1253A>G (p.Asn418Ser), and c.1303G>A (p.Val435Ile)) were found in SEMA3A in three KS patients, two of which also had a mutation in FGFR1. Two rare heterozygous variants (c.442C>T (p.Arg148Trp) and c.1421G>A (p.Arg474Gln)) in SEMA7A were found in one male nHH patient with a previously identified KISS1R nonsense variant and one male KS patient with a previously identified mutation in KAL1, respectively.Conclusion:Our results suggest that heterozygous missense variants in SEMA3A and SEMA7A may modify the phenotype of KS but most likely are not alone sufficient to cause the disorder.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To assess the change in non-compliant items in prescription orders following the implementation of a computerized physician order entry (CPOE) system named PreDiMed. SETTING: The department of internal medicine (39 and 38 beds) in two regional hospitals in Canton Vaud, Switzerland. METHOD: The prescription lines in 100 pre- and 100 post-implementation patients' files were classified according to three modes of administration (medicines for oral or other non-parenteral uses; medicines administered parenterally or via nasogastric tube; pro re nata (PRN), as needed) and analyzed for a number of relevant variables constitutive of medical prescriptions. MAIN OUTCOME MEASURE: The monitored variables depended on the pharmaceutical category and included mainly name of medicine, pharmaceutical form, posology and route of administration, diluting solution, flow rate and identification of prescriber. RESULTS: In 2,099 prescription lines, the total number of non-compliant items was 2,265 before CPOE implementation, or 1.079 non-compliant items per line. Two-thirds of these were due to missing information, and the remaining third to incomplete information. In 2,074 prescription lines post-CPOE implementation, the number of non-compliant items had decreased to 221, or 0.107 non-compliant item per line, a dramatic 10-fold decrease (chi(2) = 4615; P < 10(-6)). Limitations of the computerized system were the risk for erroneous items in some non-prefilled fields and ambiguity due to a field with doses shown on commercial products. CONCLUSION: The deployment of PreDiMed in two departments of internal medicine has led to a major improvement in formal aspects of physicians' prescriptions. Some limitations of the first version of PreDiMed were unveiled and are being corrected.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Colorectal cancer is among the three most common and lethal neoplasms in Switzerland (about 4,000 new cases and 1,600 deaths per year, respectively). Several screening modalities are available. The effectiveness of colorectal cancer screening on mortality is established. The implementation of a successful screening intervention shall follow specified phases and conditions, and abide with global principles: pooling and coordinating efforts from all partners, setting goals and priorities, and identifying action plans. A feasibility (pilot) study is needed to verify requirements for quality, effectiveness, efficiency and innocuousness. Endeavours towards implementing a pilot programme for colorectal cancer screening in the Vaud canton (Switzerland) are presented and discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Screening tests for subclinical cardiovascular disease, such as markers of atherosclerosis, are increasingly used in clinical prevention to identify individuals at high cardiovascular risk. Being aware of these test results might also enhance patient motivation to change unhealthy behaviors but the effectiveness of such a screening strategy has been poorly studied. METHODS: The CAROtid plaque Screening trial on Smoking cessation (CAROSS) is a randomized controlled trial in 530 regular smokers aged 40-70 years to test the hypothesis that carotid plaque screening will influence smokers' behavior with an increased rate of smoking cessation (primary outcome) and an improved control of other cardiovascular risk factors (secondary outcomes) after 1-year follow-up. All smokers will receive a brief advice for smoking cessation,and will subsequently be randomly assigned to either the intervention group (with plaques screening) or the control group (without plaque screening). Carotid ultrasound will be conducted with a standard protocol. Smokers with at least one carotid plaque will receive pictures of their own plaques with a structured explanation on the general significance of plaques. To ensure equal contact conditions, smokers not undergoing ultrasound and those without plaque will receive a relevant explanation on the risks associated with tobacco smoking. Study outcomes will be compared between smokers randomized to plaque screening and smokers not submitted to plaque screening. SUMMARY: This will be the first trial to assess the impact of carotid plaque screening on 1-year smoking cessation rates and levels of control of other cardiovascular risk factors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Digital Holographic Microscopy (DHM), is a new imaging technique allowing to provide quantitative phase images with a high accuracy and stability making possible to explore a large variety of relevant processes, occurring on the p.s to day time scale, in the fields including material research as well as cell biology. As a non invasive and real time imaging technique, DHM is particularly well suited for high throughput screening

Relevância:

20.00% 20.00%

Publicador:

Resumo:

For doping control, analyses of samples are generally achieved in two steps: a rapid screening and, in the case of a positive result, a confirmatory analysis. A two-step methodology based on ultra-high-pressure liquid chromatography coupled to a quadrupole time-of-flight mass spectrometry (UHPLC-QTOF-MS) was developed to screen and confirm 103 doping agents from various classes (e.g., beta-blockers, stimulants, diuretics, and narcotics). The screening method was presented in a previous article as part I (i.e., Fast analysis of doping agents in urine by ultra-high-pressure liquid chromatography-quadrupole time-of-flight mass spectrometry. Part I: screening analysis). For the confirmatory method, basic, neutral and acidic compounds were extracted by a dedicated solid-phase extraction (SPE) in a 96-well plate format and detected by MS in the tandem mode to obtain precursor and characteristic product ions. The mass accuracy and the elemental composition of precursor and product ions were used for compound identification. After validation including matrix effect determination, the method was considered reliable to confirm suspect results without ambiguity according to the positivity criteria established by the World Anti-Doping Agency (WADA). Moreover, an isocratic method was developed to separate ephedrine from its isomer pseudoephedrine and cathine from phenylpropanolamine in a single run, what allowed their direct quantification in urine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dementia and its most common cause, Alzheimer’s disease, affect memory and occur predominantly in the elderly. Dementia has become increasingly prevalent in the world as health has improved and life expectancy has increased. However, the fields of clinical care have not responded adequately to develop diagnostic tools and treatments for this rapidly increasing group of conditions. While scientists search for cures for the numerous causes of dementia, improvement of diagnostic measures are needed now and should begin with screening elderly populations for memory difficulties and other cognitive problems. This review examines the history of cognitive screening tests, the numerous excellent tests that are currently available and ready for use, and directions and methods that will lead to progressively better evaluations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study was conducted to compare among the most recent generation of five screening tests licensed in Argentina, in order to evaluate which of the tests has the best sensitivity for detection of antibodies against hepatitis C virus (HCV). The tests analyzed were: Detect-HCV™ (3.0) Biochem ImmunoSystems, Canada; Hepatitis C EIA Wiener Lab., Argentina; Equipar HCV Ab, Italy; Murex HCV 4.0, UK and Serodia-HCV particles agglutination test, Japan. The results obtained showed high discrepancy between the different kits used and show that some of the tests assessed have a low sensitivity for anti-HCV detection in both chronic infections and early seroconversion, and indicate that among the commercially available kits in Argentina, Murex HCV 4.0 (UK) and Serodia-HCV particles agglutination test (Japan) have the best sensitivity for HCV screening. Although the sensitivity of the assays is the first parameter to be considered for blood screening, more studies should be carried out to assess the specificity of such assays.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To increase blood safety Brazil introduced screening for anti-HBc among blood donors in 1993. There was a decrease in the hepatitis B virus (HBV) transmission, but this measure identified a great number of HBsAg-negative, anti-HBc-positive donors. Surveillance policy determines that contacts of HBV carriers should be screened to HBV markers, but there is no recommendation about how to guide contacts of HBsAg-negative, anti-HBc-positive donors. Aiming to evaluate whether the contacts of this group are at greater risk for HBV infection, a cross-sectional study was performed to compare prevalence of HBV infection between contacts of HBsAg-positive blood donors (group I) and contacts of HBsAg-negative, anti-HBc-positive donors (group II). Contacts were submitted to a questionnaire and blood tests for HBV markers. In group I (n = 143), 53 (37.1%) were anti-HBc-positive and 11 (7.7%) were HBsAg-positive. In group II (n = 111), there were 9 and 0.9%, respectively. HBV exposure was associated with group I, sexual activity, blood transfusion, being one of the donor's parents, and living for more than ten years with the donor. Regarding the families as sample units, it was more common to find at least one member with HBV markers (p < 0.05) among the families of group I compared to group II. Contacts of HBsAg-negative, anti-HBc-positive individuals presented a much lower risk of having already been exposed to HBV and there is no need to screen them for HBV in low to moderate prevalence populations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Erythrovirus B19 infects erythrocytic progenitors, transiently interrupting erythropoiesis. In AIDS patients it causes chronic anemia amenable to treatment. We looked for evidences of B19 infection in stored bone marrow material from patients with acquired immunodeficiency syndrome. Histological sections were made from stored paraffin blocks from 33 autopsies (39 blocks) and 35 biopsies (45 blocks, 30 patients) performed from 1988 to 2002. They were examined after hematoxylin-eosin (HE) staining, immunohistochemical (IHC), and in situ hybridization. HE revealed intra-nuclear inclusion bodies ("lantern cells") suggesting B19 infection in 19 sections corresponding to 19 of 63 patients examined with this test. Seven of 78 sections subjected to immunohistochemistry were positive, corresponding to 7 of 58 patients examined with this test. Fourteen sections corresponding to 13 of the 20 HE and/or IHC positive patients were subjected to in situ hybridization, with six positives results. Among the 13 patients subjected to the three techniques, only one gave unequivocal positive results in all and was considered a true positive. The frequency of B19 infection (1/63 patients) in the material examined can be deemed low.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Public Health Agency's bowel cancer screening programme awareness campaign launch took place on Friday 3 February 2012 at PHA, Ormeau Avenue, Belfast.�The public information campaign includes television, radio, press, outdoor advertising on buses and washroom advertisements. It runs from �6 February- 31 March, 2012.Attached below are the�public information leaflets and posters as part of the campaign.