968 resultados para Reflect Array


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Previous claims that auditory stream segregation occurs in cochlear implant listeners are based on limited evidence. In experiment 1, eight listeners heard tones presented in a 30-s repeating ABA-sequence, with frequencies matching the centre frequencies of the implant's 22 electrodes. Tone A always stimulated electrode 11 (centre of the array); tone B stimulated one of the others. Tone repetition times (TRTs) from 50 to 200 ms were used. Listeners reported when they heard one or two streams. The proportion of time that each sequence was reported as segregated was consistently greater with increased electrode separation. However, TRT had no significant effect, and the perceptual reversals typical of normal-hearing listeners rarely occurred. The results may reflect channel discrimination rather than stream segregation. In experiment 2, six listeners performed a pitch-ranking task using tone pairs (reference = electrode 11). Listeners reported which tone was higher in pitch (or brighter in timbre) and their confidence in the pitch judgement. Similarities were observed in the individual pattern of results for reported segregation and pitch discrimination. Many implant listeners may show little or no sign of automatic stream segregation owing to the reduced perceptual space within which sounds can differ from one another. © 2006 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The authors have demonstrated an optical fibre grating based delay line which produces time delays in increments as small as 31 ps. The device could provide a true time delay component for a phased array antenna

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to test the hypothesis that differences in density of senile plaques (SP) and neurofibrillary tangles (NFT) in the cuneal and lingual gyri of area V1 of the visual cortex could explain the predominantly inferior visual field defects seen in patients with Alzheimer's disease (AD). The density of SP and NFT was measured in the cuneal and lingual gyri of 18 AD patients. In 7/18 (39%) patients, the density of SP and/or NFT was significantly greater in the cuneal compared with the lingual gyri. In 3/18 (17%) patients, densities were greater in the lingual than the cuneal gyri and in 8/18 (44%) patients there were no significant differences among gyri. The data suggest that pathological differences between cuneal and lingual gyri could contribute to the reported visual field defects in some AD patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sensory cells usually transmit information to afferent neurons via chemical synapses, in which the level of noise is dependent on an applied stimulus. Taking into account such dependence, we model a sensory system as an array of LIF neurons with a common signal. We show that information transmission is enhanced by a nonzero level of noise. Moreover, we demonstrate a phenomenon similar to suprathreshold stochastic resonance with additive noise. We remark that many properties of information transmission found for the LIF neurons was predicted by us before with simple binary units [Phys. Rev. E 75, 021121 (2007)]. This confirmation of our predictions allows us to point out identical roots of the phenomena found in the simple threshold systems and more complex LIF neurons.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The channelled spectrum of an optical beam generated by a laser diode operated below threshold after traversing microscope glass plates is spectrally analysed using a grating and a CCD linear array. The experiment has the following goals: to display the resulting channelled spectrum, to familiarize students with an important topic in metrology and to illustrate some interesting topics from spectroscopy using a CCD array as a spectrometer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel form of low coherence interferometric sensor is described. The channelled spectrum produced by illuminating a sensing interferometer with a broadband source is analysed directly using a CCD array. The system currently provides unambiguous measurement over a range of 1.5 mm with an accuracy of better than 6 µm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The fabrication of in-fibre Bragg gratings, and the application of arrays of such gratings as strain sensors and as true time delay elements for the control of phased array antennas is reported. Chirped period Bragg gratings were produced using the fibre deformation fabrication technique, with chirps of between 2.9nm and 17.3nm achieved. Arrays of 5mm and 2mm long uniform period Bragg gratings were fabricated using the inscription method, for use as true time delay elements,dissimilar wavefronts and their spectral characteristics recorded. The uniform period grating arrays were used to create minimum time delays of 9.09ps, 19.02ps and 31ps; making them suitable for controlling phased array antennas operating at RF frequencies of up to 3GHz, with 10° phase resolution. Four 4mm long chirped gratings were produced using the dissimilar wavefronts fabrication method, having chirps of 7nm, 12nm, 20nm and 30nm, and were used to create time delays of between 0.3ps and 59ps. Hence they are suitable for controlling phased array antennas at RF frequencies of up to 48GHz. The application of in fibre Bragg gratings as strain sensors within smart structure materials was investigated, with their sensitivity to applied strain and compression measured for both embedded and surface mounted uniform period and fibre Fabry-Perot filter gratings. A fibre Bragg grating sensor demultiplexing scheme based on a liquid crystal filled Fabry-Perot etalon tuneable transmission filter was proposed, successfully constructed and fully characterised. Three characteristics of the LCFP etalon were found to pose operational limitations to its application in a Bragg grating sensor system; most significantly, the resonance peak wavelength was highly (-2,77nm/°C) temperature dependent. Several methods for minimising this temperature sensitivity were investigated, but enjoyed only limited success. It was therefore concluded that this type (E7 filled) of LCFP etalon is unsuitable for use as a Bragg grating sensor demultiplexing element.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The slow down in the drug discovery pipeline is, in part, owing to a lack of structural and functional information available for new drug targets. Membrane proteins, the targets of well over 50% of marketed pharmaceuticals, present a particular challenge. As they are not naturally abundant, they must be produced recombinantly for the structural biology that is a prerequisite to structure-based drug design. Unfortunately, however, obtaining high yields of functional, recombinant membrane proteins remains a major bottleneck in contemporary bioscience. While repeated rounds of trial-and-error optimization have not (and cannot) reveal mechanistic details of the biology of recombinant protein production, examination of the host response has provided new insights. To this end, we published an early transcriptome analysis that identified genes implicated in high-yielding yeast cell factories, which has enabled the engineering of improved production strains. These advances offer hope that the bottleneck of membrane protein production can be relieved rationally.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fibre Bragg Grating (FBG) array sensors have been successfully embedded in aluminium alloy matrix by ultrasonic consolidation (UC) technique. The temperature and loading responses of the embedded FBG arrays have been systematically characterised. The embedded grating sensors exhibit an average temperature sensitivity of ~36pm/°C, which is three times higher than that of normal FBGs, and a loading responsivity of ~0.1nm/kg within the dynamic range from 0kg to 3kg. This initial experiment clearly demonstrates that FBG array sensors can be embedded in metal matrix together with other passive and active fibres to fabricate smart materials to monitor the operation and health of engineering structures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A practical implementation of coherent wavelength division multiplexing (CoWDM) is demonstrated for the first time using injection-locked lasers and a DPSK modulator array. For a 31.99 Gbit/s system (three subcarriers at 10.664 Gbit/s) the null-to-null spectral bandwidth was only 42.656 GHz and the average receiver sensitivity measured was -33.5 dBm when all subcarrier phases were optimised.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Optical fibre strain sensors using Fibre Bragg Gratings (FBGs) are poised to play a major role in structural health monitoring in a variety of application from aerospace to civil engineering. At the heart of technology is the optoelectronic instrumentation required to convert optical signals into measurands. Users are demanding compact, lightweight, rugged and low cost solutions. This paper describes development of a new device based on a blazed FBG and CCD array that can potentially meet the above demands. We have shown that this very low cost technique may be used to interrogate a WDM array of sensor gratings with highly accurate and highly repeatable results unaffected by the polarisation state of the radiation. In this paper, we present results showing that sensors may be interrogated with an RMS error of 1.7pm, drift below 0.12pm and dynamic range of up to 65nm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

"Reflection, if managed in an ordered way, can provide great opportunities for learning, understanding and clarifying thought, both in one's personal life and in learning and professional development." Moon, J (1999). Aston Business School's (ABS) 12cmonth professional placement programme has a number of espoused learning objectives, including helping students: 1. To benefit from the integration of university study and work experience in ways which facilitate critical reflection on each ofthese aspects. 2. To build a personal awareness of their own interests, competencies, values and potential. These objectives focus students' development to self-reflect critically, to make sense of their experiences/learning whilst undertaking their placements. Students complete a placement year Reflective Learning Journal, supported by the workplace supervisor, through regular meetings where objectives are agreed and reviewed. As well as reflection providing opportunities for students to make sense of their learning, it is also challenging! ABS is undertaking a pilot in 2008/9 to encourage students to engage with reflective practice, but employer feedback indicates an ability to think and analyse is often missing from the skill sets of graduates. Business students are using the PebblePad e-portfolio system as a tool to record their learning, reflect on their experiences in the workplace and to create their journals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim was to define post-caesarean dyspareunia as a sexual and pelvic-perineal symptom. Post-caesarean (80 elective, 104 emergency) and 100 vaginally delivered primiparae had domiciliary interviews at 10 months postpartum. A total of 50 (28% and 27%) post-caesarean and 46 (46%) vaginally delivered, reported dyspareunia. Severely impaired general sexual health occurred in 82 (24% elective, 25% emergency, 35% vaginally delivered) as category 3 (dyspareunia with sexual symptoms) and 27 (10% elective, 7% emergency, 12% vaginally delivered) as category 4 (reduced frequency <6). The risk of dyspareunia (RR 1.14, CI 0.73, 1.77) or impaired general sexual health (RR 0.93, CI 0.32, 2.74) was similar among those with or without perineal trauma. Both caesarean and perineal scars were associated with sexual malfunction. Primiparae with new incontinence had a lower risk of dyspareunia than impaired general sexual health. Awareness of the associations of post-caesarean dyspareunia and impaired general sexual health with incontinence would facilitate appropriate obstetric decision-making. Further research is indicated. © 2011 Informa UK, Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel form of low coherence interferometric sensor is described. The channelled spectrum produced by illuminating a sensing interferometer with a broadband source is analysed directly using a CCD array. The system currently provides unambiguous measurement over a range of 1.5 mm with an accuracy of better than 6 µm.