921 resultados para Readings and recitations.


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Nutrient leaching studies are expensive and require expertise in water collection and analyses. Less expensive or easier methods that estimate leaching losses would be desirable. The objective of this study was to determine if anion-exchange membranes (AEMs) and reflectance meters could predict nitrate (NO3-N) leaching losses from a cool-season lawn turf. A two-year field study used an established 90% Kentucky bluegrass (Poa pratensis L.)-10% creeping red fescue (Festuca rubra L.) turf that received 0 to 98 kg N ha-1 month-1, from May through November. Soil monolith lysimeters collected leachate that was analyzed for NO3-N concentration. Soil NO3-N was estimated with AEMs. Spectral reflectance measurements of the turf were obtained with chlorophyll and chroma meters. No significant (p > 0.05) increase in percolate flow-weighted NO3-N concentration (FWC) or mass loss occurred when AEM desorbed soil NO3-N was below 0.84 µg cm-2 d-1. A linear increase in FWC and mass loss (p < 0.0001) occurred, however, when AEM soil NO3-N was above this value. The maximum contaminant level (MCL) for drinking water (10 mg L-1 NO3-N) was reached with an AEM soil NO3-N value of 1.6 µg cm-2 d-1. Maximum meter readings were obtained when AEM soil NO3 N reached or exceeded 2.3 µg cm-2 d-1. As chlorophyll index and hue angle (greenness) increased, there was an increased probability of exceeding the NO3-N MCL. These data suggest that AEMs and reflectance meters can serve as tools to predict NO3-N leaching losses from cool-season lawn turf, and to provide objective guides for N fertilization.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background. Ambulatory blood pressure (ABP) measurement is a means of monitoring cardiac function in a noninvasive way, but little is known about ABP in heart failure (HF) patients. Blood pressure (BP) declines during sleep as protection from consistent BP load, a phenomenon termed "dipping." The aims of this study were (1) to compare BP dipping and physical activity between two groups of HF patients with different functional statuses and (2) to determine whether the strength of the association between ambulatory BP and PA is different between these two different functional statuses of HF. ^ Methods. This observational study used repeated measures of ABP and PA over a 24-hour period to investigate the profiles of BP and PA in community-based individuals with HF. ABP was measured every 30 minutes by using a SpaceLabs 90207, and a Basic Motionlogger actigraph was used to measure PA minute by minute. Fifty-six participants completed both BP and physical activity for a 24-hour monitoring period. Functional status was based on New York Heart Association (NYHA) ratings. There were 27 patients with no limitation of PA (NYHA class I HF) and 29 with some limitation of PA but no discomfort at rest (NYHA class II or III HF). The sample consisted of 26 men and 30 women, aged 45 to 91 years (66.96 ± 12.35). ^ Results. Patients with NYHA class I HF had significantly greater dipping percent than those with NYHA class II/III HF after controlling their left ventricular ejection fraction (LVEF). In a mixed model analysis (PROC MIXED, SAS Institute, v 9.1), PA was significantly related to ambulatory systolic and diastolic BP and mean arterial pressure. The strength of the association between PA and ABP readings was not significantly different for the two groups of patients. ^ Conclusions. These preliminary findings demonstrate differences between NYHA class I and class II/III of HF in BP dipping status and ABP but not PA. Longitudinal research is recommended to improve understanding of the influence of disease progression on changes in 24-hour physical activity and BP profiles of this patient population. ^ Key Words. Ambulatory Blood Pressure; Blood Pressure Dipping; Heart Failure; Physical Activity. ^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Context. Despite the rapid growth of disease management programs, there are still questions about their efficacy and effectiveness for improving patient outcomes and their ability to reduce costs associated with chronic disease. ^ Objective. To determine the effectiveness of disease management programs on improving the results of HbA1c tests, lipid profiles and systolic blood pressure (SBP) readings among diabetics. These three quantitative measures are widely accepted methods of determining the quality of a patient's diabetes management and the potential for future complications. ^ Data Sources. MEDLINE and CINAHL were searched from 1950 to June 2008 using MeSH terms designed to capture all relevant studies. Scopus pearling and hand searching were also done. Only English language articles were selected. ^ Study Selection. Titles and abstracts for the 2347 articles were screened against predetermined inclusion and exclusion criteria, yielding 217 articles for full screening. After full article screening, 29 studies were selected for inclusion in the review. ^ Data Extraction. From the selected studies, data extraction included sample size, mean change over baseline, and standard deviation for each control and experimental arm. ^ Results. The pooled results show a mean HbA1c reduction of 0.64%, 95% CI (-0.83 to -0.44), mean SBP reduction of 7.39 mmHg (95% CI to -11.58 to -3.2), mean total cholesterol reduction of 5.74 mg/dL (95% CI, -10.01 to -1.43), and mean LDL cholesterol reduction of 3.74 mg/dL (95% CI, -8.34 to 0.87). Results for HbA1c, SBP and total cholesterol were statistically significant, while the results for LDL cholesterol were not. ^ Conclusions. The findings suggest that disease management programs utilizing five hallmarks of care can be effective at improving intermediate outcomes among diabetics. However, given the significant heterogeneity present, there may be fundamental differences with respect to study-specific interventions and populations that render them inappropriate for meta-analysis. ^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Physical activity is a key component of life-style modification process which helps to reduce the risk of developing chronic diseases. It is important to have accurate estimates of physical activity to identify sedentary populations where interventions might be helpful. The International Physical Activity Questionnaire (IPAQ) short version has been used to estimate physical activity in diverse populations. However, there is little literature depicting the use of the IPAQ short version in Mexican America population. This study addressed the predictive validity and test-retest reliability of the IPAQ short version in Mexican American adults. The analysis was performed on 97 participants enrolled in the Cameron County Hispanic Cohort. Individuals selected in this study were 18 years of age or older. The predictive validity was evaluated by studying the relationship between physical activity and biomarkers known to be correlated with physical activity, namely, TNF-α, Adiponectin, and HDL. Multiple linear regression analysis was performed to delineate predictive validity. To assess test-retest reliability, two IPAQ-short last seven days questionnaires were interviewer administered to the participants on the same day, approximately two hours apart. Test-Retest reliability of IPAQ was estimated by performing intraclass correlations between the readings at two different time periods. The study showed that the IPAQ – short version used in the above study had acceptable test-retest reliability in the Mexican American population. This study showed that the IPAQ – short version did not have acceptable predictive validity when looking at physical activity and TNF-α, Adiponectin, and HDL in this sample.^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Underwater spectral reflectance was measured for selected biotic and abiotic coral reef features of Glovers Reef, Belize from March 6 - 10, 2005. Spectral reflectance's of 63 different benthic types were obtained in-situ. An Ocean Optics USB2000 spectrometer was deployed in an custom made underwater housing with a 0.5 m fiber-optic probe mounted next to an artificial light source. Spectral readings were collected with the probe (bear fibre) about 5 cm from the target to ensure that the target would fill the field of view of the fiber optic (FOV diameter ~4.4 cm), as well as to reduce the attenuating effect of the intermediate water (Roelfsema et al., 2006). Spectral readings included for one target included: 1 reading of the covered spectral fibre to correct for instrument noise, 1 reading of spectralon panel mounted on divers wrist to measure incident ambient light, and 8 readings of the target. Spectral reflectance was calculated for each target by first subtracting the instrument noise reading from each other reading. The corrected target readings were then divided by the corrected spectralon reading resulting in spectral reflectance of each target reading. An average target spectral reflectance was calculated by averaging the eight individual spectral reflectance's of the target. If an individual target spectral reflectance was visual considered an outlier, it was not included in the average spectral reflectance calculation. See Roelfsema at al. (2006) for additional info on the methodology of underwater spectra collection.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Sonne transit cruise SO226-3 DipFIP took place from March 4th (Wellington, New Zealand) to March 28th (Kaohsiung, Taiwan) in 2013. CTD data for 16 stations along the cruise track were recorded using the onboard a SEABIRD SBE 9 plus CTD down to depth of 800m. Obtained hydrographic data were binned to 1 m intervals with the available SBE software. Obvious outliers in the readings of the oxygen sensor close to the sea surface have been manually removed. Fluorospectrometer (bbe Moldaenke) pigment data measured for 24 depth intervals are available for 10 stations. Measurements were conducted in the shipboard laboratory on water samples from the CTD rosette. Data are averages of a least 30 readings per sample.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Underwater spectral reflectance was measured for selected biotic and abiotic coral reef features of Heron Reef from June 25-30, 2006. Spectral reflectance's of 105 different benthic types were obtained in-situ. An Ocean Optics USB2000 spectrometer was deployed in an custom made underwater housing with a 0.5 m fiber-optic probe mounted next to an artificial light source. Spectral readings were collected with the probe(bear fibre) about 5 cm from the target to ensure that the target would fill the field of view of the fiber optic (FOV diameter ~4.4 cm), as well as to reduce the attenuating effect of the intermediate water (Roelfsema et al., 2006). Spectral readings included for one target included: 1 reading of the covered spectral fibre to correct for instrument noise, 1 reading of spectralon panel mounted on divers wrist to measure incident ambient light, and 8 readings of the target. Spectral reflectance was calculated for each target by first subtracting the instrument noise reading from each other reading. The corrected target readings were then divided by the corrected spectralon reading resulting in spectral reflectance of each target reading. An average target spectral reflectance was calculated by averaging the eight individual spectral reflectance's of the target. If an individual target spectral reflectance was visual considered an outlier, it was not included in the average spectral reflectance calculation. See Roelfsema at al. (2006) for additional info on the methodology of underwater spectra collection.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Sør Rondane Mountains (SRM) in eastern Dronning Maud Land (DML) are located in an area, where two apparent Pan-African (650-520 Ma) orogenic mobile belts appear to intersect, the East African-Antarctic Orogen and the Kuunga Orogen. Hence, a better understanding of the tectonic structure of the Sør Rondane region is an important key for unravelling the complex geodynamic evolution of the eastern DML and adjacent regions of East Antarctica during the Late Neoproterozoic/Early Palaeozoic amalgamation of Gondwana. The SRM were recently (2011-2012) aerogeophysically investigated with a 5 km flight line spacing, covering a total area of ~140,000 km². The aeromagnetic data are correlated with ground-based magnetic susceptibility measurements and geological field data and allow to project tectonic terranes and individual structures into ice-covered areas. Magnetic anomalies and basement foliation trends are collinear in areas dominated by simple shear deformation, whereas an area of large-scale refolding correlates with a subdued small-scale broken magnetic anomaly pattern. The latter area can be regarded as a distinct tectonic domain, the central Sør Rondane corridor. It magnetically separates the SRM into an eastern, a central, and a western portion. This subdivision is presumably related to late Pan-African extensional tectonics and suggests that such a tectonic regime may play a larger role than previously assumed. Voluminous late Pan-African granitoids, which are mainly undeformed, correlate with positive magnetic anomalies between +30 and +80 nT, while a strong magnetic high (+680 nT) near the granitic intrusion at Dufekfjellet is caused by a highly magnetised enigmatic body. The recently discovered prominent magnetic anomaly province of southeastern DML continues into the southern part of the Sør Rondane region, where only a few outcrops are exposed. Findings at these westernmost nunataks of the SRM indicate that the subdued magnetic anomaly pattern of this southeastern DML province is most likely caused by the predominance of metasedimentary rocks of yet unknown age.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The "SESAME_IT4_ZooAbundance_0-50-100m_SZN" dataset contains data of mesozooplankton species composition and abundance (ind./m**3) from samples collected in the Western Mediterranean in the early spring of 2008 (20 March-5 April) during the SESAME-WP2 cruise IT4. Samples were collected by vertical tows with a closing WP2 net (56 cm diameter, 200 µm mesh size) in the following depth layers: 100-200 m, 50-100 m, 0-50 m. Sampling was always performed in light hours. A flowmeter was applied to the mouth of the net, however, due to its malfunctioning, the volume of filtered seawater was calculated by multiplying the the area by the height of the sampled layer from winch readings. After collection, each sample was split in two halves (1/2) after careful mixing with graduated beakers. Half sample was immediately fixed and preserved in a formaldehyde-seawater solution (4% final concentration) for species composition and abundance. The other half sample was kept fresh for biomass measurements (data already submitted to SESAME database in different files). Here, only the zooplankton abundance of samples in the upper layers 0-50 m and 50-100 m are presented. The abundance data of the samples in the layer 50-100 m will be submitted later in a separate file. The volume of filtered seawater was estimated by multiplying the the area by the height of the sampled layer from winch readings. Identification and counts of specimens were performed on aliquots (1/20-1/5) of the fixed sample or on the total sample (half of the original sample) by using a graduate large-bore pipette. Copepods were identified to the species level and separated into females, males and juveniles (copepodites). All other taxa were identified at the species level when possible, or at higher taxonomic levels. Taxonomic identification was done according to the most relevant and updated taxonomic literature. Total mesozooplankton abundance was computed as sum of all specific abundances determined as explained above.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Oxygen penetration depth and temperature at the rim of the clam colony was measured with a small deep-sea microprofiler module (Treude et al., 2009), carrying 3 oxygen Clark-type microelectrodes (Revsbech et al., 1980) and one temperature sensor (Pt100, UST Umweltsensorentechnik GmbH, Germany). High-resolution microprofiles across the sediment-water interface were measured with a vertical resolution of 100 µm on a total length of 15 cm. Oxygen electrodes had a linear response to the oxygen concentration in seawater and were calibrated in situ using constant readings in the bottom water (oxygen concentration determined by Winkler titration) and the anoxic parts of the sediment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Snow height was measured by the Snow Depth Buoy 2014S13, an autonomous platform, drifting on Arctic sea ice, deployed during the CryoVEx2014 field campaign. The resulting time series describes the evolution of snow height as a function of place and time between 2014-03-30 and 2014-07-20 in sample intervals of 1 hour. The Snow Depth Buoy consists of four independent sonar measurements representing the area (approx. 10 m**2) around the buoy. The buoy was installed on multi year ice. In addition to snow height, geographic position (GPS), barometric pressure, air temperature, and ice surface temperature were measured. Negative values of snow height occur if surface ablation continues into the sea ice. Thus, these measurements describe the position of the sea ice surface relative to the original snow-ice interface. Differences between single sensors indicate small-scale variability of the snow pack around the buoy. The data set has been processed, including the removal of obvious inconsistencies (missing values). Records without any snow height may still be used for sea ice drift analyses. Note: This data set contains only relative changes in snow height, because no initial readings of absolute snow height are available.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Snow height was measured by the Snow Depth Buoy 2013S1, an autonomous platform, installed close to Neumayer III Base, Antarctic during Antarctic Fast Ice Network 2013 (AFIN 2013). The resulting time series describes the evolution of snow height as a function of place and time between 2013-02-11 and 2013-04-29 in sample intervals of 1 hour. The Snow Depth Buoy consists of four independent sonar measurements representing the area (approx. 10 m**2) around the buoy. The buoy was installed on the ice shelf. In addition to snow height, geographic position (GPS), barometric pressure, air temperature, and ice surface temperature were measured. Negative values of snow height occur if surface ablation continues into the sea ice. Thus, these measurements describe the position of the sea ice surface relative to the original snow-ice interface. Differences between single sensors indicate small-scale variability of the snow pack around the buoy. The data set has been processed, including the removal of obvious inconsistencies (missing values). Records without any snow height may still be used for sea ice drift analyses. Note: This data set contains only relative changes in snow height, because no initial readings of absolute snow height are available.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Snow height was measured by the Snow Depth Buoy 2013S4, an autonomous platform, installed on land-fast sea ice off Barrow, Alaska during SIZONet 2013. The resulting time series describes the evolution of snow height as a function of place and time between 2013-04-09 and 2013-06-28 in sample intervals of 1 hour. The Snow Depth Buoy consists of four independent sonar measurements representing the area (approx. 10 m**2) around the buoy. The buoy was installed on land-fast sea ice. In addition to snow height, geographic position (GPS), barometric pressure, air temperature, and ice surface temperature were measured. Negative values of snow height occur if surface ablation continues into the sea ice. Thus, these measurements describe the position of the sea ice surface relative to the original snow-ice interface. Differences between single sensors indicate small-scale variability of the snow pack around the buoy. The data set has been processed, including the removal of obvious inconsistencies (missing values). Records without any snow height may still be used for sea ice drift analyses. Note: This data set contains only relative changes in snow height, because no initial readings of absolute snow height are available.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The dataset is composed of 61 samples from 15 stations. The phytoplankton samples were collected by 5l Niskin bottles attached to the CTD system. The sampling depths were selected according to the CTD profile and the in situ fluorometer readings: surface, temperature, salinity and fluorescence gradients and 1 m above the bottom. At some stations phytoplankton net samples (20 µm mesh-size) were collected to assist species biodiversity examination. The samples (1l sea water) were preserved in 4% buffered to pH 8-8.2 with disodiumtetraborate formaldehyde solution and stored in plastic containers. On board at each station few live samples were qualitatively examined under microscope for preliminary analysis of taxonomic composition and dominant species. Taxon-specific phytoplankton abundance were concentrated down to 50 cm**3 by slow decantation after storage for 20 days in a cool and dark place. The species identification was done under light microscope OLIMPUS-BS41 connected to a video-interactive image analysis system at magnification of the ocular 10X and objective - 40X. A Sedgwick-Rafter camera (1ml) was used for counting. 400 specimen were counted for each sample, while rare and large species were checked in the whole sample (Manual of phytoplankton, 2005). Species identification was mainly after Carmelo T. (1997) and Fukuyo, Y. (2000). The cell biovolume of the taxon-specific phytoplankton biomass was determined based on morpho-metric measurement of phytoplankton units and the corresponding geometric shapes as described in detail in (Edier, 1979).