999 resultados para Radio sources (Astronomy)


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper analyzes the choice between different innovationactivities of a firm. In particular, we study the technologyacquisition decision of the firm, i.e. its technology BUYdecision as part of the firm's innovation strategy. We take a closer look at the different types of external technologyacquisition where we distinguish two broad types of technologybuy decisions. On the one hand, the firm can acquire new technology which is embodied in an asset that is acquired suchas new personnel or (parts of) other firms or equipment. On the other hand, the firm can obtain new technology disembodiedthrough a licensing agreement or by outsourcing the technologydevelopment from an R&D contractor or consulting agency. Through a series of Probit regressions, we discuss variables that might affect external technology acquisition choices of the firm andpay special attention to the firm's abilities to scan the market for technology and to absorb the technology acquired. Furthermore, we analyze the effect of different appropriationregimes on the decision of the firm to source technology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

[ANGLÈS] This project introduces GNSS-SDR, an open source Global Navigation Satellite System software-defined receiver. The lack of reconfigurability of current commercial-of-the-shelf receivers and the advent of new radionavigation signals and systems make software receivers an appealing approach to design new architectures and signal processing algorithms. With the aim of exploring the full potential of this forthcoming scenario with a plurality of new signal structures and frequency bands available for positioning, this paper describes the software architecture design and provides details about its implementation, targeting a multiband, multisystem GNSS receiver. The result is a testbed for GNSS signal processing that allows any kind of customization, including interchangeability of signal sources, signal processing algorithms, interoperability with other systems, output formats, and the offering of interfaces to all the intermediate signals, parameters and variables. The source code release under the GNU General Public License (GPL) secures practical usability, inspection, and continuous improvement by the research community, allowing the discussion based on tangible code and the analysis of results obtained with real signals. The source code is complemented by a development ecosystem, consisting of a website (http://gnss-sdr.org), as well as a revision control system, instructions for users and developers, and communication tools. The project shows in detail the design of the initial blocks of the Signal Processing Plane of the receiver: signal conditioner, the acquisition block and the receiver channel, the project also extends the functionality of the acquisition and tracking modules of the GNSS-SDR receiver to track the new Galileo E1 signals available. Each section provides a theoretical analysis, implementation details of each block and subsequent testing to confirm the calculations with both synthetically generated signals and with real signals from satellites in space.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aims to provide a passive sampling approach which can be routinely used to investigate polychlorinated biphenyl (PCB) sources in rivers. The approach consists of deploying low density polyethylene (LDPE) strips downstream and upstream of potential PCB sources as well as in their water discharges. Concentrations of indicator PCBs (iPCBs) absorbed in samplers (Cs) from upstream and downstream sites are compared with each other to reveal increases of PCB levels. Cs measured in water discharges are used to determine if released amounts of PCBs are compatible with increases revealed in the river. As water velocity can greatly vary along a river stretch and influences the uptake at each site in a different way, differences in velocity have to be taken into account to correctly interpret Cs. LDPE strips were exposed to velocities between 1.6 and 37 cm s−1 using a channel system built in the field. Relationships between velocity and Cs were established for each iPCB to determine the expected change in Cs due to velocity variations. For PCBs 28 and 52, this change does not exceed a factor 2 for velocity variations in the range from 1.6 to 100 cm s−1 (extrapolated data above 37 cm s−1). For PCBs 101, 138, 153 and 180, this change only exceeds a factor 2 in the case of large velocity variations. The approach was applied in the Swiss river Venoge to first conduct a primary investigation of potential PCB sources and then conduct thorough investigations of two suspected sources.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Advanced stage follicular lymphoma is incurable by conventional treatment. Important progress has been observed with the development of new therapies based on monoclonal antibodies and on the use of radioimmunotherapy (RIT) in the treatment of non-Hodgkin lymphomas (NHL). Rituximab in combination with chemotherapy in the upfront setting significantly improved treatment outcome as compared with chemotherapy alone. Different studies also indicate that RIT has an important role in the management of NHL and could be beneficial in combination with chemotherapy. These two new treatment options have clearly distinctive mechanisms of action, rituximab being an exclusively biological treatment and RIT adding targeted systemic radiation therapy. Both RIT and the unlabeled antibody treatments might be further improved by different strategies including repetition of RIT or combination of different antibodies. We present here our experience with RIT using 131I-tositumomab (Bexxar) and discuss different topics regarding RIT, like the use of different antibodies, the best choice of the radioisotope or the place of radio-imaging. From the therapeutic point of view, we argue that the debate should not be as to which one among antibody immunotherapy or RIT should be best added to chemotherapy, but that all three treatments might be optimally combined with the aim to get the highest chance of cure for advanced stage follicular lymphoma.