915 resultados para Paediatric fractures


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Therapy of metacarpal neck fractures depending on radiographically measured palmar angulation is discussed controversially in the literature. Some authors describe normal hand function of malunited metacarpal neck fractures with a palmar angulation up to 70°; others define 30° as the uppermost limit to maintain normal hand function. However, the methods of measuring palmar angulation are not clearly defined. Here, we present a new method to measure palmar angulation using ultrasound. The aim of this prospective study is to compare the radiographic methods of measuring palmar angulation with the ultrasound method. PATIENTS/MATERIAL AND METHOD: 20 patients with a neck fracture of the metacarpals IV or V were treated either conservatively or operatively. 2 weeks after trauma or operation, an x-ray was performed. 2 examiners measured the palmar angulation on the oblique and lateral projections using 2 different methods (medullary canal and dorsal cortex methods). At the same time, the 2 examiners performed measurements of palmar angulation using ultrasound. The measurements obtained with the different methods as well as by the 2 examiners at 2 different terms were compared. Intra- and interobserver reliability of each method was calculated, and for the ultrasound method a test for accuracy of the measured angles was performed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Apart from one article published by Rabl and Sigrist in 1992 (Rechtsmedizin 2:156-158), there are no further reports on secondary skull fractures in shots from captive bolt guns. Up to now, the pertinent literature places particular emphasis on the absence of indirect lesions away from the impact point, when dealing with the wounding capacity of slaughterer's guns. The recent observation of two suicidal head injuries accompanied by skull fractures far away from the bolt's path gave occasion to experimental studies using simulants (glycerin soap, balls from gelatin) and skull brain models. As far as ballistic soap was concerned, the dimensions of the bolt's channel were assessed by multi-slice computed tomography before cutting the blocks open. The test shots to gelatin balls and to skull-brain models were documented by means of a high-speed motion camera. As expected, the typical temporary cavity effect of bullets fired from conventional guns could not be observed when captive bolt stunners were discharged. Nevertheless, the visualized transfer of kinetic energy justifies the assumption that the secondary fractures seen in thin parts of the skull were caused by a hydraulic burst effect.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE OF REVIEW: Critical incident reporting alone does not necessarily improve patient safety or even patient outcomes. Substantial improvement has been made by focusing on the further two steps of critical incident monitoring, that is, the analysis of critical incidents and implementation of system changes. The system approach to patient safety had an impact on the view about the patient's role in safety. This review aims to analyse recent advances in the technique of reporting, the analysis of reported incidents, and the implementation of actual system improvements. It also explores how families should be approached about safety issues. RECENT FINDINGS: It is essential to make as many critical incidents as possible known to the intensive care team. Several factors have been shown to increase the reporting rate: anonymity, regular feedback about the errors reported, and the existence of a safety climate. Risk scoring of critical incident reports and root cause analysis may help in the analysis of incidents. Research suggests that patients can be successfully involved in safety. SUMMARY: A persisting high number of reported incidents is anticipated and regarded as continuing good safety culture. However, only the implementation of system changes, based on incident reports, and also involving the expertise of patients and their families, has the potential to improve patient outcome. Hard outcome criteria, such as standardized mortality ratio, have not yet been shown to improve as a result of critical incident monitoring.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To clarify the patterns of frontobasal and frontosinal fractures in children and teenagers and to analyze whether the patterns relate to developmental stage of the facial skeleton.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The two major causative factors for mandibular fractures, as stated in the literature, are either interpersonal violence or motor vehicle accidents. The purpose of this study was to describe epidemiological trends of mandibular fractures in Switzerland. A special emphasis was directed towards the potential impact of socio-economic standards on the mechanism and pattern of mandible fractures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Antrochoanal polyps are hyperplasias of the nasal mucosa, which have their origin in the maxillary sinus and extend through the nasal cavity and the choanae into the naso- and oropharynx. In children antrochoanal polyps represent one of the more frequent manifestations of paediatric nasal polyposis. Most studies on antrochoanal polyps in children report only on nasal obstruction, hyponasal speech and snoring, which are also encountered in the most common cause of obstructive sleep apnoea syndrome; i.e. adenoid or tonsillar hyperplasia. Only very few studies report on additional health hazards by antrochoanal polyps ranging from obstructive sleep apnoea syndrome to swallowing disorders and cachexia. We present the case of an 8 year old girl with a bicycle accident caused by excessive daytime sleepiness and obstructive sleep apnoea syndrome due to an extensive antrochoanal polyp. After a transnasal polypectomy and meatotomy type II the obstructive sleep apnoea and day time sleepiness resolved completely. Awareness of this additional health hazard is important and correct evaluation and timely diagnosis of a potential antrochoanal polyp is mandatory because minimally invasive rhinosurgery is highly curative in preventing further impending problems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract Introduction Vertebroplasty (VP) is a cost-efficient alternative to kyphoplasty; however, regarding safety and vertebral body (VB) height restoration, it is considered inferior. We assessed the safety and efficacy of VP in alleviating pain, improving quality of life (QoL) and restoring alignment. Methods In a prospective monocenter case series from May 2007 until July 2008, there were 1,408 vertebroplasties performed during 319 interventions in 306 patients with traumatic, lytic and osteoporotic fractures. The 249 interventions in 233 patients performed because of osteoporotic vertebral fractures were analyzed regarding demographics, treatment and radiographic details, pain alleviation (VAS), QoL improvement (NASS and EQ-5D), complications and predictors for new fractures requiring a reoperation. Results The osteoporotic patient sample consisted of 76.7% (179) females with a median age of 80 years. A total of 54 males had a median age of 77 years. On average, there were 1.8 VBs fractured and 5 VBs treated. The preoperative pain was assessed by the visual analog scale (VAS) and decreased from 54.9 to 40.4 pts after 2 months and 31.2 pts after 6 months. Accordingly, the QoL on the EQ-5D measure (−0.6 to 1) improved from 0.35 pts before surgery to 0.56 pts after 2 and to 0.68 pts after 6 months. The preoperative Beck Index (anterior height/posterior height) improved from a mean of 0.64 preoperative to 0.76 postoperative, remained stable at 2 months and slightly deteriorated to 0.72 at 6 months postoperatively. There were cement leakages in 26% of the fractured VBs and in 1.4% of the prophylactically cemented VBs; there were symptoms in 4.3%, and most of them were temporary hypotension and one pulmonary cement embolism that remained asymptomatic. The univariate regression model revealed a tendency for a reduced risk for new or refractures on radiographs (OR = 2.61, 95% CI 0.92–7.38, p = 0.12) and reoperations (OR = 2.9, 95% CI 0.94–8.949, p = 0.1) when prophylactic augmentation was performed. The final multivariate regression model revealed male patients to have an about three times higher refracture risk (radiographic) (OR = 2.78, p = 0.02) at 6 months after surgery. Patients with a lumbar index fracture had an about three to five times higher refracture/reoperation risk than patients with a thoracic (OR = 0.33/0.35, p = 0.009/0.01) or thoracolumbar (OR = 0.32/0.22, p = 0.099/0.01) index fracture. Conclusion If routinely used, VP is a safe and efficacious treatment option for osteoporotic vertebral fractures with regard to pain relief and improvement of the QoL. Even segmental realignment can be partially achieved with proper patient positioning. Certain patient or fracture characteristics increase the risk for early radiographic refractures or new fractures, or a reoperation; a consequent prophylactic augmentation showed protective tendencies, but the study was underpowered for a final conclusion.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ventricular assist devices (VADs) and total artificial hearts have been in development for the last 50 years. Since their inception, simulators of the circulation with different degrees of complexity have been produced to test these devices in vitro. Currently, a new path has been taken with the extensive efforts to develop paediatric VADs, which require totally different design constraints. This paper presents the manufacturing details of an economical simulator of the systemic paediatric circulation. This simulator allows the insertion of a paediatric VAD, includes a pumping ventricle, and is adjustable within the paediatric range. Rather than focusing on complexity and physiological simulation, this simulator is designed to be simple and practical for rapid device testing. The simulator was instrumented with medical sensors and data were acquired under different conditions with and without the new PediaFlowTM paediatric VAD. The VAD was run at different impeller speeds while simulator settings such as vascular resistance and stroke volume were varied. The hydraulic performance of the VAD under pulsatile conditions could be characterized and the magnetic suspension could be tested via manipulations such as cannula clamping. This compact mock loop has proven to be valuable throughout the PediaFlow development process and has the advantage that it is uncomplicated and can be manufactured cheaply. It can be produced by several research groups and the results of different VADs can then be compared easily.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To clarify the occurrence, causes, severity, and predictors of concomitant injuries in pediatric patients with facial fractures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pulmonary fat embolism (PFE) is frequently encountered in blunt trauma. The clinical manifestation ranges from no impairment in light cases to death due to right-sided heart failure or hypoxaemia in severe cases. Occasionally, pulmonary fat embolism can give rise to a fat embolism syndrome (FES), which is marked by multiorgan failure, respiratory disorders, petechiae and often death. It is well known that fractures of long bones can lead to PFE. Several authors have argued that PFE can arise due to mere soft tissue injury in the absence of fractures, a claim other authors disagree upon. In this study, we retrospectively examined 50 victims of blunt trauma with regard to grade and extent of fractures and crushing of subcutaneous fatty tissue and presence and severity of PFE. Our results indicate that PFE can arise due to mere crushing of subcutaneous fat and that the fracture grade correlated well with PFE severity (p = 0.011). The correlation between PFE and the fracture severity (body regions affected by fractures and fracture grade) showed a lesser significant correlation (p = 0.170). The survival time (p = 0.567), the amount of body regions affected by fat crushing (p = 0.336) and the fat crush grade (p = 0.485) did not correlate with the PFE grade, nor did the amount of body regions affected by fractures. These results may have clinical implications for the assessment of a possible FES development, as, if the risk of a PFE is known, preventive steps can be taken.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In Switzerland, the number, incidence, and cost of acute hospitalizations for major osteoporotic fractures (MOF) and major cardiovascular events (MCE) increased in both women and men between 2000 and 2008, although the mean length of stay (LOS) was significantly reduced. Similar trend patterns were observed for hip fractures and strokes (decrease) and nonhip fractures and acute myocardial infarctions (increase).