852 resultados para OSTEOPOROTIC HIP FRACTURES


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fractures of the proximal femur are common in the elderly population. Intramedullary nailing has become the standard treatment for intertrochanteric fractures although several extramedullary implants (e.g. dynamic hip screw (DHS), blade plate, locking compression plate (LCP), etc.) exist. However, despite this being a very common operation in traumatology, there are numerous associated complications. We report the rare complication of the migration of the medial lag screw into the pelvis at five and a half weeks postoperatively. The implant was removed and replaced by a total hip arthroplasty with simultaneous grafting of the acetabular defect and strapping of the greater trochanter. The evolution was favourable. We also present a review of the literature and analyze our case.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Osteoporosis is a systemic bone disease that is characterized by a generalized reduction of the bone mass. It is the main cause of fractures in elderly women. Bone densitometry is used in the lumbar spine and hip in order to detect osteoporosis in its early stages. Different studies have observed a correlation between the bone mineral density of the jaw (BMD) and that of the lumbar spine and/or hip. On the other hand, there are studies that evaluate the findings in the orthopantomograms and perapical X-rays, correlating them with the early diagnosis of osteoporosis and highlighting the role of the dentist in the early diagnosis of this disease. Materials and methods: A search was carried out in the Medline-Pubmed database in order to identify those articles that deal with the association between the X-ray findings observed in the orthopantomograms and the diagnosis of the osteoporosis, as well as those that deal with the bone mineral density of the jaw. Results: There were 406 articles, and with the limits established, this number was reduced to 21. Almost all of the articles indicate that when examining oral X-rays, it is possible to detect signs indicative of osteoporosis. Discussion: The radiomorphometric indices use measurements in orthopantomograms and evaluate possible loss of bone mineral density. They can be analyzed alone or along with the visual indices. In the periapical X-rays, the photodensimetric analyses and the trabecular pattern appear to be the most useful. There are seven studies that analyze the densitometry of the jaw, but only three do so independently of the photodensitometric analysis. Conclusions: The combination of mandibular indices, along with surveys on the risk of fracture, can be useful as indicators of early diagnosis of osteoporosis. Visual and morphometric indices appear to be especially important in the orthopantomograms. Photodensitometry indices and the trabecular pattern are used in periapical X-rays. Studies on mandibular dual-energy X-ray absorptiometry are inconclusive

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The eccentric contraction mode was proposed to be the primary stimulus for optimum angle (angle at which peak torque occurs) shift. However, the training range of motion (or muscle excursion range) could be a stimulus as important. The aim of this study was to assess the influence of the training range of motion stimulus on the hamstring optimum length. It was hypothesised that performing a single set of concentric contractions beyond optimal length (seated at 80° of hip flexion) would lead to an immediate shift of the optimum angle to longer muscle length while performing it below (supine at 0° of hip flexion) would not provide any shift. Eleven male participants were assessed on an isokinetic dynamometer. In both positions, the test consisted of 30 consecutive knee flexions at 4.19 rad · s⁻¹. The optimum angle was significantly shifted by ∼15° in the direction of longer muscle length after the contractions at 80° of hip flexion, while a non-significant shift of 3° was found at 0°. The hamstring fatigability was not influenced by the hip position. It was concluded that the training range of motion seems to be a relevant stimulus for shifting the optimum angle to longer muscle length. Moreover, fatigue appears as a mechanism partly responsible for the observed shift.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Current guidelines for the prevention of cardiovascular disease (CVD) recommend diabetes as a CVD risk equivalent. However, reports that have examined the risk of diabetes in comparison to pre-existing CVD are lacking among older women. We aimed to assess whether diabetes was associated with a similar risk of total and cause-specific mortality as a history of CVD in older women. METHODOLOGY/PRINCIPAL FINDINGS: We studied 9218 women aged 68 years or older enrolled in a prospective cohort study (Study of Osteoporotic Fracture) during a mean follow-up period of 11.7 years and compared all-cause, cardiovascular and coronary heart disease mortality among 4 groups: non-diabetic women with and without existing CVD, diabetic women with and without existing CVD. Mean (SD) age of the participants was 75.2 (5.3) years, 3.5% reported diabetes and 6.8% reported existing CVD. During follow-up, 5117 women died with 36% from CVD. The multivariate adjusted risk of cardiovascular mortality was increased among both non-diabetic women with CVD (hazard ratio (HR) 2.32, 95% CI: 1.97-2.74, P<0.001) and diabetic women without CVD (HR 2.06, CI: 1.62-2.64, P<0.001) compared to non-diabetic women without existing CVD. All-cause, cardiovascular and coronary mortality of non-diabetic women with CVD were not significantly different from diabetic women without CVD. CONCLUSIONS/SIGNIFICANCE: Older diabetic women without CVD have a similar risk of cardiovascular mortality compared to non-diabetic women with pre-existing CVD. The equivalence of diabetes and CVD seems to extend to older women, supporting current guidelines for cardiovascular prevention.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Complications related to the neck-stem junction of modular stems used for total hip arthroplasty (THA) are generating increasing concern. A 74-year-old male had increasing pain and a cutaneous reaction around the scar 1 year after THA with a modular neck-stem. Imaging revealed osteolysis of the calcar and a pseudo-tumour adjacent to the neck-stem junction. Serum cobalt levels were elevated. Revision surgery to exchange the stem and liner and to resect the pseudo-tumour was performed. Analysis of the stem by scanning electron microscopy and by energy dispersive X-ray and white light interferometry showed fretting corrosion at the neck-stem junction contrasting with minimal changes at the head-neck junction. Thus, despite dry assembly of the neck and stem on the back table at primary THA, full neck-stem contact was not achieved, and the resulting micromotion at the interface led to fretting corrosion. This case highlights the mechanism of fretting corrosion at the neck-stem interface responsible for adverse local tissue reactions. Clinical and radiological follow-up is mandatory in patients with dual-modular stems.