468 resultados para NO stripping


Relevância:

10.00% 10.00%

Publicador:

Resumo:

C2-C8 hydrocarbon concentrations (about 35 compounds identified, including saturated, aromatic, and olefinic compounds) from 27 shipboard-sealed, deep-frozen core samples of DSDP Hole 603B off the east coast of North America were determined by a gas-stripping/thermovaporization method. Total yields representing the hydrocarbons dissolved in the pore water and adsorbed on the mineral surfaces of the sediments vary from 22 to 2400 ng/g of dryweight sediment. Highest yields are measured in the two black shale samples of Core 603B-34 (hydrogen index of 360 and 320 mg/g Corg, respectively). In organic-carbon-normalized units these samples have hydrocarbon contents of 12,700 and 21,500 ng/g Corg, respectively, indicating the immaturity of their kerogens. Unusually high organic-carbonnormalized yields are associated with samples that are extremely lean in organic carbon. It is most likely that they are enriched by small amounts of migrated light hydrocarbons. This applies even to those samples with high organic-carbon contents (1.3-2.2%) of Sections 603B-28-4, 603B-29-1, 603B-49-2, and 603B-49-3, because they have an extremely low hydrocarbon potential (hydrogen index between 40 and 60 mg/g Corg). Nearly all samples were found to be contaminated by varying amounts of acetone that is used routinely in large quantities on board ship during core-cutting procedures. Therefore, 48 samples from the original set of 75 collected had to be excluded from the present study.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A series of core samples taken during Cruise 79 of Glomar Challenger, drilling offshore Morocco (Mazagan Plateau), is analyzed for their low-molecular-weight hydrocarbon contents. Fifty-four samples from DSDP Holes 544A, 545, 547A, and 547B, deep frozen on board immediately after recovery, are studied by a hydrogen-stripping/thermovaporization technique combined with capillary gas chromatography. Thirty-eight compounds in the C2-C8 molecular range, including saturated, olefinic, and aromatic hydrocarbons, are identified. Because of large differences in organic carbon contents, the total C2-C8 hydrocarbon concentrations vary from about 20 to 1500 ng/g dry sediment weight in the whole sample series. Organic-carbon normalized values are about 3.2 x 10**4 ng/g Corg for Lithologic Subunits IIIA and IIIB at Site 545 (Cenomanian to Aptian) and 1.0 x 10**5 ng/g Corg for Unit V at Site 547 (Cenomanian to Albian) reflecting the slightly more advanced maturity stage at the latter site. Values exceeding 10**5 ng/g Corg (Site 545) and 2 x 10**5 ng/g Corg (Site 547) are associated with samples that are very lean in organic carbon and are generally rich in carbonate. These samples are enriched by small amounts of gaseous hydrocarbons. A detailed study of individual hydrocarbon concentrations, plotted against depth, reveal additional indications for migration phenomena. At Site 547, for instance, the most mobile hydrocarbons studied (e.g., ethane) appear to migrate by diffusion or a related process from more than 700 m depth toward the surface.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

C2-C8 hydrocarbons (36 compounds identified) from 56 shipboard sealed, deep-frozen core samples of DSDP Leg 71, Site 511, Falkland Plateau, South Atlantic, were analyzed by a combined hydrogen stripping-thermovaporization method. Concentrations, which represent hydrocarbons dissolved in the pore water and adsorbed to the mineral surfaces of the sediment, vary from 24 ng/g of dry weight sediment in Lithologic Unit 4 to 17,400 ng/g in Lithologic Unit 6 ("black shale" unit). Likewise, the organic carbon normalized C2-C8 hydrocarbon concentrations range from 104 to 3.5 x 105 ng/g Corg. The latter value is more than one order of magnitude lower than expected for petroleum source beds in the main phase of oil generation. The low maturity at 600 meters depth is further supported by light hydrocarbon concentration ratios. The change of the kerogen type from Lithologic Unit 5 (Type III) to 6 (Type II) is evidenced by changes in the C6 and C7 hydrocarbon composition. Redistribution phenomena are observed close to the Tertiary-Cretaceous unconformity and at the contact between the "black shale" unit and the overlying Cretaceous chalks and claystones. Otherwise, the low molecular weight hydrocarbons in Hole 511 are formed in situ and remain at their place of formation. The core samples turned out to be contaminated by large quantities of acetone, which is routinely used as a solvent during sampling procedures onboard Glomar Challenger.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Hydrothermal vent fluids are highly enriched in iron (Fe) compared to ambient seawater, and organic ligands may play a role in facilitating the transport of some hydrothermal Fe into the open ocean. This is important since Fe is a limiting micronutrient for primary production in large parts of the world's surface ocean. We have investigated the concentration and speciation of Fe in several vent fluid and plume samples from the Nifonea vent field, Coriolis Troughs, New Hebrides Island Arc, South Pacific Ocean using competitive ligand exchange-adsorptive cathodic stripping voltammetry (CLE-AdCSV) with salicylaldoxime (SA) as the artificial ligand. Our results for total dissolved Fe (dFe) in the buoyant hydrothermal plume samples showed concentrations up to 3.86 µM dFe with only a small fraction between 1.1 and 11.8% being chemically labile. Iron binding ligand concentrations ([L]) were found in µM level with strong conditional stability constants up to logKFeL,Fe3+ of 22.9. Within the non-buoyant hydrothermal plume above the Nifonea vent field, up to 84.7% of the available Fe is chemically labile and [L] concentrations up to 97 nM were measured. [L] was consistently in excess of Felab, indicating that all available Fe is being complexed, which in combination with high Felab values in the non-buoyant plume, signifies that a high fraction of hydrothermal dFe is potentially being transported away from the plume into the surrounding waters, contributing to the global oceanic Fe budget.

Relevância:

10.00% 10.00%

Publicador:

Resumo:


Experimental tests have been completed for high-strength 8.8 bolts for studying their mechanical performance subjected to tensile loading. As observed from these tests, failure of structural bolts has been identified as in one of two ways: threads stripping and necking of the threaded portion of the bolt shank, which is possibly due to the degree of fit between internal and external threads. Following the experimental work, a numerical approach has been developed for demonstration of the tensile performance with proper consideration of tolerance class between bolts and nuts. The degree of fit between internal and external threads has been identified as a critical factor affecting failure mechanisms of high-strength structural bolts in tension, which is caused by the machining process. In addition, different constitutive material laws have been taken into account in the numerical simulation, demonstrating the entire failure mechanism for structural bolts with different tolerance classes in their threads. It is also observed that the bolt capacities are closely associated with their failure mechanisms.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The main objective of this R&D work is to simulate particle beam optics in CV-28 Cyclotron of Instituto de Engenharia Nuclear – IEN/CNEN, as a support for improvements or optimization of this particle accelerator. Besides 2D magnetostatic field computation results, the authors present an alternative method for charged particle trajectories computation in electrostatic or magnetostatic fields. This task is approached by analytical computation of trajectories, by parts, considering constant fields within each finite element. This method has some advantages over numerical integration ones: numerical miscomputation of trajectories is avoided; stability problem is also avoided, for the magnetostatic field case. Some examples are presented, including positive ion extraction from cyclotrons with strip-foil. This latter technique is an interesting alternative for upgrading positive ion cyclotrons, such as CV-28 Cyclotron. The particle trajectory computation method presented in this work is of interest not only for cyclotrons, but for accelerator and related technology, in general.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction. Subfascial Endoscopic Perforator Surgery (SEPS) enables the direct visualization and section of perforating veins. Morbidity and duration of hospitalization are both less than with conventional open surgery (Linton’s or Felder’s techniques). Patients and methods. A total of 322 legs from 285 patients with a mean age of 56 years (range 23-90) were treated at our Department from May 1996 to January 2010. In 309 cases, an endoscope (ETM Endoskopische Technik GmbH, Berlin, Germany) was introduced through a transverse incision approximately 1.5 cm in length and 10 cm from the tibial tuberosity, as with Linton’s technique. A spacemaker balloon dissector for SEPS, involving a second incision 6 cm from the first, was used in only 13 cases. Results. The procedure used in each case was decided on the basis of preoperative evaluation. SEPS and stripping were performed in 238 limbs (73.91%), SEPS and short stripping in 7 limbs (2.17%), SEPS and crossectomy in 51 limbs (15.84%), and SEPS alone in 26 limbs (8.07%). 103 patients presented a total of 158 trophic ulcers; the healing time was between 1 and 3 months, with a healing rate of 82.91% after 1 month and 98.73% after 3 months. Conclusion. Subfascial ligature of perforating veins is superior to sclerotherapy and minimally invasive suprafascial treatment for the treatment of CVI. It is easy to execute, minimally invasive and has few complications.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The present study was aimed at assessing the experience of a single referral center with recurrent varicose veins of the legs (RVL) over the period 1993-2008. Among a total of 846 procedures for Leg Varices (LV), 74 procedures were for RVL (8.7%). The causes of recurrence were classified as classic: insufficient crossectomy (13); incompetent perforating veins (13); reticular phlebectasia (22); small saphenous vein insufficiency (9); accessory saphenous veins (4); and particular: post-hemodynamic treatment (5); incomplete stripping (1); Sapheno-Femoral Junction (SFJ) vascularization (5); post-thermal ablation (2). For the “classic” RVL the treatment consisted essentially of completing the previous treatment, both if the problem was linked to an insufficient earlier treatment and if it was due to a later onset. The most common cause in our series was reticular phlebectasia; when the simple sclerosing injections are not sufficient, this was treated by phlebectomy according to Mueller. The “particular” cases classified as 1, 2 and 4 were also treated by completing the traditional stripping procedure (+ crossectomy if this had not been done previously), considered to be the gold standard. In the presence of a SFJ neo-vascularization, with or without cavernoma, approximately 5 cm of femoral vein were explored, the afferent vessels ligated and, if cavernoma was present, it was removed. Although inguinal neo-angiogenesis is a possible mechanism, some doubt can be raised as to its importance as a primary factor in causing recurrent varicose veins, rather than their being due to a preexisting vein left in situ because it was ignored, regarded as insignificant, or poorly evident. In conclusion, we stress that LV is a progressive disease, so the treatment is unlikely to be confined to a single procedure. It is important to plan adequate monitoring during follow-up, and to be ready to reoperate when new problems present that, if left, could lead the patient to doubt the validity and efficacy of the original treatment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Os sedimentos podem atuar tanto como acumuladores quanto como fontes de poluentes. Em função das atividades portuárias locais estarem em ritmo de crescimento pela ampliação do porto de Rio Grande (RS), estudos que mostrem a situação do local investigado são importantes a fim de prever o aporte do ferro nesse ambiente. Neste trabalho, a especiação química do ferro e a determinação da concentração do metal total e dissolvido em amostras de águas intersticiais no sedimento do Saco do Mendanha (RS) foram avaliadas, utilizando a Voltametria Adsortiva de Redissolução Catódica com o ligante 2,3-Dihidroxinaftaleno. O objetivo principal desse trabalho foi validar a metodologia analítica para realizar a especiação química do ferro em águas intersticiais, o que englobou a faixa linear de trabalho, limites de detecção e de quantificação, a exatidão e precisão. O Limite de Detecção encontrado foi de 0,11 nmol L-1 . Foram determinadas as concentrações de ferro total, dissolvido e lábil em três frações distintas: na interface água/sedimento, entre 0 e -5 cm; e entre -15 e -20 cm de profundidade na coluna sedimentar. Nas amostras analisadas, a concentração de ferro lábil encontrada foi entre 4,64 – 135,37 µmol L-1 ; a concentração do metal dissolvido foi de 6,25 – 322,70 µmol L-1 e de ferro total entre 83,36 – 390,30 µmol L-1 . A concentração do metal lábil em comparação com a fração dissolvida e total indica a presença de complexos estáveis entre o metal e a matéria orgânica natural presente na água intersticial, tornando dessa forma, o metal menos biodisponível para a biota local. Durante os meses de amostragem do sedimento, foi observada variação da concentração do metal, onde no mês de abril ocorreu o maior aporte do metal da coluna d’água para o sedimento. Essa transferência do metal para o sedimento pode estar relacionada pela forte mudança na salinidade no local de amostragem, passando de 16 no mês de fevereiro para 33 no mês de abril e para próximo de zero nos meses de agosto e novembro de 2009.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: In contrast to other countries, surgery still represents the common invasive treatment for varicose veins in Germany. However, radiofrequency ablation, e.g. ClosureFast, becomes more and more popular in other countries due to potential better results and reduced side effects. This treatment option may cause less follow-up costs and is a more convenient procedure for patients, which could justify an introduction in the statutory benefits catalogue. Therefore, we aim at calculating the budget impact of a general reimbursement of ClosureFast in Germany. Methods: To assess the budget impact of including ClosureFast in the German statutory benefits catalogue, we developed a multi-cohort Markov model and compared the costs of a “World with ClosureFast” with a “World without ClosureFast” over a time horizon of five years. To address the uncertainty of input parameters, we conducted three different types of sensitivity analysis (one-way, scenario, probabilistic). Results: In the Base Case scenario, the introduction of the ClosureFast system for the treatment of varicose veins saves costs of about 19.1 Mio. € over a time horizon of five years in Germany. However, the results scatter in the sensitivity analyses due to limited evidence of some key input parameters. Conclusions: Results of the budget impact analysis indicate that a general reimbursement of ClosureFast has the potential to be cost-saving in the German Statutory Health Insurance.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A presença de metais traço no ambiente está associada às fontes naturais e antropogênicas. O aumento das concentrações desses elementos pode resultar em um desequilíbrio do ecossistema tornando-se um risco potencial para o meio. O metal cromo tem seus efeitos relacionados com sua concentração e com o estado de oxidação em que se apresenta, já que seu estado trivalente é considerando essencial, enquanto que seu estado hexavalente é considerado extremamente tóxico. O objetivo deste trabalho é realizar a especiação química do cromo após ter sido realizada a revalidação analítica, englobando faixa linear de trabalho, limites de detecção e quantificação, exatidão e precisão. Este estudo é essencial tanto pela questão ambiental quanto sanitária, já que a especiação foi realizada em cinco pontos do Estuário da Lagoa dos Patos - dois na Zona Portuária e três no Saco da Mangueira, entre os meses de março e setembro de 2008 e também na Estação de Tratamento de Água que ocorreram entre os meses de janeiro e setembro de 2008. Foram realizadas determinações das frações de Cr (III) ativo, Cr (VI) e Cr (III) não ativo, por Voltametria de Redissolução Catódica. A Fração de Cromo Total foi determinada por Espectrometria de Absorção Atômica. Também foram realizadas in situ determinações dos seguintes parâmetros físicoquímicos: salinidade, pH, Eh, oxigênio dissolvido e temperatura; além dos nutrientes nitrogenados. As determinações não identificaram o metal no estado de oxidação mais tóxico (cromo hexavalente), também não foi identificada a fração de Cr (III) ativo. O metal foi identificado na forma de Cr (III) não-ativo, ou seja, na forma trivalente e complexada por ligantes naturais estáveis. As concentrações de cromo total estiveram sempre abaixo do limite estabelecido pelos órgãos reguladores competentes. Portanto, mesmo com as atividades industriais e portuárias existentes na região, não foram identificadas concentrações ou espécies de cromo que caracterizam um ambiente impactado.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

451 p.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

2-Aminothiazole covalently attached to a silica gel surface was prepared in order to obtain an adsorbent for Hg(II) ions having the following characteristics: good sorption capacity, chemical stability under conditions of use, and, especially, high selectivity. The accumulation voltammetry of mercury(II) was investigated at a carbon paste electrode chemically modified with silica gel functionalized with 2-aminothiazole (SIAMT-CPE). The repetitive cyclic voltammogram of mercury(II) solution in the potential range -0.2 to + 0.6 V versus Ag/AgCl (0.02 mol L-1 KNO3; V = 20 mV s(-1)) show two peaks one at about 0.1 V and other at 0.205 V. The anodic wave peak at 0.205 V is well defined and does not change during the cycles and it was therefore further investigated for analytical purposes using differential pulse anodic stripping voltammetry in differents supporting electrolytes. The mercury response was evaluated with respect to pH, electrode composition, preconcentration time, mercury concentration, cleaning solution, possible interferences and other variables. The precision for six determinations (n = 6) of 0.02 and 0.20 mg L-1 Hg(II) was 4.1 and 3.5% (relative standard deviation), respectively. The detection limit was estimated as 0.10 mu g L-1 mercury(II) by means of 3:1 current-to-noise ratio in connection with the optimization of the various parameters involved and using the highest-possible analyser sensitivity. (c) 2006 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Partial funding for open access provided by the UMD Libraries' Open Access Publishing Fund.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Nacomposites of polymers and lamellar clayminerals, has generated high scientific and technological interest, for having mechanical properties and gas barriers differentiated of polymers and conventional composites. In this work, it was developed nanocomposites by single screw extruder and injection, utilizing commercial raw material, with the goal to investigate the quality of new developed materials. It was evaluated the influence of the content and the kind of clay in the structure and in the nanocomposites properties. It was used regular and elastomeric poly (methyl methacrylate) (Acrigel LEP 100 and Acrigel ECP800) and six montmorillonites (Cloisite 10A, 11B, 15A, 20A, 25A e 30B) at the concentration of 1% e 3% in weight. The nanocomposites were characterized by X-ray diffraction (XRD), thermal gravimetric analysis (TGA), transmission electron microscopy (TEM), colorimetric, optical transparency, flexural and tensile tests, Rockwell hardness and esclerometry. It was founded that is possible to obtain intercalated and exfoliated nanocomposites PMMA/MMT, and the top results was obtained in the materials with 1%in clay weight organophilizated with 2M2HT (Cloisite 15A and 20A) presented intercalate and hybrid morphology (exfoliated and flocullated). The ones that was produced with organophilizated clay with 2MHTL8 (Cloisite 30B) had excellent visual quality, but the majority presented hybrid morphology. In the materials processed with organophilizated clay with MT2ETOH (Cloisite 30B), there were color change and loss of transparency. It occurs improvement in a few mechanical properties, mainly in the materials produced with PMMA elastomeric (Acrigel ECP800), being more significant, the increase in the resistance to stripping in those nanocomposites