990 resultados para Mg absorption
Optical parameters and absorption of copper (II)-azo complexes thin films as optical recording media
Resumo:
Smooth thin films of three kinds of azo dyes of 2-(5'-tert-butyl-3'-azoxylisoxazole)-1, 3-diketones and their copper (II)-azo complexes were prepared by the spin-coating method. Absorption spectra of the thin films on a glass substrate in the 300-600 nm wavelength region were measured. Optical constants (complex refractive index N=n+ik) and thickness of the thin films prepared on single-crystal silicon substrate in the 300-600 nm wavelength region were investigated on rotating analyzer-polarizer type of scanning ellipsometer, and dielectric constants epsilon(epsilon=epsilon(1)+i epsilon(2)), absorption coefficients alpha as well as reflectance R of thin films were then calculated. In addition, one of the copper (II)-azo complex thin film prepared on glass substrate with an Ag reflective layer was also studied by atomic force microscopy (AFM) and static optical recording. AFM study shows that the copper (II)-azo complex thin film is very smooth and has a root mean square surface roughness of 1.89 nm. Static optical recording shows that the recording marks on the copper (II)-azo complex thin film are very clear and circular, and the size of the minimal recording marks can reach 200 nm. (c) 2004 Elsevier B.V. All rights reserved.
Resumo:
Three kinds of metal(II) tetraazaporphyrin complexes with blue-violet and red light wavelength absorption were synthesized by refluxing tetraazaporphyrin ligand and different metal(II) ions, respectively. Their structures were confirmed by elemental analysis, LDI-TOF-MS, FT-IR and UV-Vis. The solubility of metal(II) tetraazaporphyrin complexes in organic solvents and absorption properties of their chloroform solution and films on K9 glass in the region 250-800 nm were measured. The influence on the difference of absorption maximum from metal(II) tetraazaporphyrin complexes to tetraazaporphyrin ligand by different metal(II) ions was studied. In addition, the thermal stability of the complexes was also evaluated. (c) 2006 Elsevier Ltd. All rights reserved.
Resumo:
This paper reports on the steady-state fluorescence, three- photon absorption-induced fluorescence emission and subsequently induced optical limiting behaviour of a fluorene derivative with D-pi-D structural motifs. The lifetime of the steady-state fluorescence is 0.903 ns. Large optical limiting behaviour induced by 3PA has also been demonstrated, and the nonlinear absorption coefficient gamma derived from 3PA fitting curves is 5.92 x 10(-20) cm(3)/W-2 and the corresponding molecular 3PA cross-section sigma(3)' is 1.14 x 10(-76) cm(6) s(2).
Resumo:
A associação inversa da ingestão de cálcio dietético com adiposidade corporal e pressão arterial está documentada em estudos epidemiológicos. Achados experimentais sugerem que este fenômeno pode ser mediado por alterações na concentração intracelular de cálcio ([Ca]i). Existem poucos estudos relacionando o cálcio dietético com a [Ca]i. O objetivo do presente estudo foi avaliar a relação da ingestão habitual de cálcio dietético com a [Ca]i, adiposidade corporal, perfil metabólico, biomarcadores inflamatórios, pressão arterial e função endotelial em mulheres. Para tanto, foi desenvolvido estudo transversal, com 76 mulheres na pré-menopausa submetidas à avaliação: dietética (questionário de frequência alimentar validado); da [Ca]i em eritrócitos (espectrometria de absorbância atômica); da gordura corporal (GC) total [índice de massa corporal (IMC) e % GC por bioimpedância elétrica] e central [perímetro da cintura (PC), e razão cintura quadril (RCQ)]; do perfil metabólico (glicose, colesterol e frações, insulina e HOMA-IR); dos biomarcadores inflamatórios [adiponectina e proteína C-reativa (PCR)]; dos biomarcadores da função endotelial [molécula de adesão intracelular-1 (ICAM-1), molécula de adesão celular vascular-1 (VCAM-1) e E-Selectina]; da função endotelial avaliada pelo equipamento Endo-PAT2000; e da pressão arterial. Calcitriol, paratormônio, cálcio sérico e cálcio urinário completaram o metabolismo do cálcio. As participantes foram estratificadas em 2 grupos de acordo com a ingestão habitual de cálcio: Grupo com baixa ingestão de cálcio ou BIC (n=32; ingestão de cálcio <600mg/d) e Grupo com elevada ingestão de cálcio ou AIC (n=44; ingestão de cálcio ≥600mg/d). A média da idade foi semelhante entre os grupos (Grupo BIC: 31,41,4 vs Grupo AIC: 31,41,4anos; p=0,99). Após ajustes para fatores de confundimento (idade, ingestão de energia, bebida alcoólica, proteína, carboidratos e lipídios), o Grupo AIC, em comparação com o BIC, apresentou valores significativamente mais baixos de IMC (25,65,3 vs 26,9 6,0 kg/m; p=0,02), PC (84,413,6 vs 87,815,3cm; p=0,04), % GC (31,15,9 vs 33,35,6 %; p=0,003), pressão arterial diastólica (68,210,8 vs 72,411,2 mm Hg; p=0,04) e pressão arterial média (80,1310,94 vs 83,8611,70 mmHg; p=0,04); e significativamente mais altos de HDL-colesterol (58,612,2 vs 52,912,2 mg/dL; p=0,004) e adiponectina (34572,1 19472,8 vs 31910,319385,1 ng/mL; p=0,05). A [Ca]i e as outras variáveis avaliadas não diferiram entre os grupos, mesmo após ajustes. Neste estudo realizado com mulheres, o maior consumo de cálcio se associou com valores mais baixos de adiposidade corporal total e central, pressão arterial diastólica e média; além de valores mais elevados de HDL-colesterol e adiponectina
Resumo:
When the in-plane bias magnetic field acting on a flat circular magnetic dot is smaller than the saturation field, there are two stable competing magnetization configurations of the dot: the vortex and the quasi-uniform (C-state). We measured microwave absorption properties in an array of non-interacting permalloy dots in the frequency range 1-8 GHz when the in-plane bias magnetic field was varied in the region of the dot magnetization state bi-stability. We found that the microwave absorption properties in the vortex and quasi-uniform stable states are substantially different, so that switching between these states in a fixed bias field can be used for the development of reconfigurable microwave magnetic materials.
Resumo:
Fe3O4 and ZnxFe3-xO4 pure and doped magnetite magnetic nanoparticles (NPs) were prepared in aqueous solution (Series A) or in a water-ethyl alcohol mixture (Series B) by the co-precipitation method. Only one ferromagnetic resonance line was observed in all cases under consideration indicating that the materials are magnetically uniform. The shortfall in the resonance fields from 3.27 kOe (for the frequency of 9.5 GHz) expected for spheres can be understood taking into account the dipolar forces, magnetoelasticity, or magnetocrystalline anisotropy. All samples show non-zero low field absorption. For Series A samples the grain size decreases with an increase of the Zn content. In this case zero field absorption does not correlate with the changes of the grain size. For Series B samples the grain size and zero field absorption behavior correlate with each other. The highest zero-field absorption corresponded to 0.2 zinc concentration in both A and B series. High zero-field absorption of Fe3O4 ferrite magnetic NPs can be interesting for biomedical applications.
Resumo:
Os diamantes são minerais raros e de alto valor econômico. Estes minerais se formam em condições mantélicas, numa profundidade aproximada de 150 a 200 km e ascendem à superfície englobada em magmas alcalinos e carbonatíticos, nos kimberlitos e lamproitos (depósitos primários). No presente trabalho objetivou-se o estudo da geometria do Kimberlito Régis, o qual pertence à província alcalina do Brasil Meridional, localizado no estado de Minas Gerais, na cidade de Carmo do Paranaíba. Para este estudo foi realizada uma inversão gravimétrica 3D e uma modelagem utilizando dados de gravimetria e os resultados dos estudos de magnetometria (Menezes e La Terra, 2011) e CSAMT (La Terra e Menezes, 2012). As anomalias Bouguer e magnética foram então modeladas a partir de um resultado CSAMT, apresentando como resultado um conduto vulcânico com cerca de 2800 metros de profundidade e 200 metros de largura. Já o resultado da inversão mapeou um corpo com forma de cone invertido, apresentando contrastes de densidade negativos. A metodologia de integração de métodos geofísicos mostrou-se eficiente para estudos exploratórios de kimberlitos, apresentando rapidez e baixo custo quando comparados com os métodos tradicionais.