885 resultados para Methods for Multi-criteria Evaluation
Resumo:
This paper focuses on evaluating the usability of an Intelligent Wheelchair (IW) in both real and simulated environments. The wheelchair is controlled at a high-level by a flexible multimodal interface, using voice commands, facial expressions, head movements and joystick as its main inputs. A Quasi-experimental design was applied including a deterministic sample with a questionnaire that enabled to apply the System Usability Scale. The subjects were divided in two independent samples: 46 individuals performing the experiment with an Intelligent Wheelchair in a simulated environment (28 using different commands in a sequential way and 18 with the liberty to choose the command); 12 individuals performing the experiment with a real IW. The main conclusion achieved by this study is that the usability of the Intelligent Wheelchair in a real environment is higher than in the simulated environment. However there were not statistical evidences to affirm that there are differences between the real and simulated wheelchairs in terms of safety and control. Also, most of users considered the multimodal way of driving the wheelchair very practical and satisfactory. Thus, it may be concluded that the multimodal interfaces enables very easy and safe control of the IW both in simulated and real environments.
Resumo:
Radio frequency (RF) energy harvesting is an emerging technology that will enable to drive the next generation of wireless sensor networks (WSNs) without the need of using batteries. In this paper, we present RF energy harvesting circuits specifically developed for GSM bands (900/1800) and a wearable dual-band antenna suitable for possible implementation within clothes for body worn applications. Besides, we address the development and experimental characterization of three different prototypes of a five-stage Dickson voltage multiplier (with match impedance circuit) responsible for harvesting the RF energy. Different printed circuit board (PCB) fabrication techniques to produce the prototypes result in different values of conversion efficiency. Therefore, we conclude that if the PCB fabrication is achieved by means of a rigorous control in the photo-positive method and chemical bath procedure applied to the PCB it allows for attaining better values for the conversion efficiency. All three prototypes (1, 2 and 3) can power supply the IRIS sensor node for RF received powers of -4 dBm, -6 dBm and -5 dBm, and conversion efficiencies of 20, 32 and 26%, respectively. © 2014 IEEE.
Resumo:
OBJECTIVE Develop an index to evaluate the maternal and neonatal hospital care of the Brazilian Unified Health System.METHODS This descriptive cross-sectional study of national scope was based on the structure-process-outcome framework proposed by Donabedian and on comprehensive health care. Data from the Hospital Information System and the National Registry of Health Establishments were used. The maternal and neonatal network of Brazilian Unified Health System consisted of 3,400 hospitals that performed at least 12 deliveries in 2009 or whose number of deliveries represented 10.0% or more of the total admissions in 2009. Relevance and reliability were defined as criteria for the selection of variables. Simple and composite indicators and the index of completeness were constructed and evaluated, and the distribution of maternal and neonatal hospital care was assessed in different regions of the country.RESULTS A total of 40 variables were selected, from which 27 single indicators, five composite indicators, and the index of completeness of care were built. Composite indicators were constructed by grouping simple indicators and included the following variables: hospital size, level of complexity, delivery care practice, recommended hospital practice, and epidemiological practice. The index of completeness of care grouped the five variables and classified them in ascending order, thereby yielding five levels of completeness of maternal and neonatal hospital care: very low, low, intermediate, high, and very high. The hospital network was predominantly of small size and low complexity, with inadequate child delivery care and poor development of recommended and epidemiological practices. The index showed that more than 80.0% hospitals had a low index of completeness of care and that most qualified heath care services were concentrated in the more developed regions of the country.CONCLUSIONS The index of completeness proved to be of great value for monitoring the maternal and neonatal hospital care of Brazilian Unified Health System and indicated that the quality of health care was unsatisfactory. However, its application does not replace specific evaluations.
Resumo:
The characteristics of carbon fibre reinforced laminates had widened their use, from aerospace to domestic appliances. A common characteristic is the need of drilling for assembly purposes. It is known that a drilling process that reduces the drill thrust force can decrease the risk of delamination. In this work, delamination assessment methods based on radiographic data are compared and correlated with mechanical test results (bearing test).
Resumo:
The structural integrity of multi-component structures is usually determined by the strength and durability of their unions. Adhesive bonding is often chosen over welding, riveting and bolting, due to the reduction of stress concentrations, reduced weight penalty and easy manufacturing, amongst other issues. In the past decades, the Finite Element Method (FEM) has been used for the simulation and strength prediction of bonded structures, by strength of materials or fracture mechanics-based criteria. Cohesive-zone models (CZMs) have already proved to be an effective tool in modelling damage growth, surpassing a few limitations of the aforementioned techniques. Despite this fact, they still suffer from the restriction of damage growth only at predefined growth paths. The eXtended Finite Element Method (XFEM) is a recent improvement of the FEM, developed to allow the growth of discontinuities within bulk solids along an arbitrary path, by enriching degrees of freedom with special displacement functions, thus overcoming the main restriction of CZMs. These two techniques were tested to simulate adhesively bonded single- and double-lap joints. The comparative evaluation of the two methods showed their capabilities and/or limitations for this specific purpose.
Resumo:
ABSTRACT OBJECTIVE To develop an assessment tool to evaluate the efficiency of federal university general hospitals. METHODS Data envelopment analysis, a linear programming technique, creates a best practice frontier by comparing observed production given the amount of resources used. The model is output-oriented and considers variable returns to scale. Network data envelopment analysis considers link variables belonging to more than one dimension (in the model, medical residents, adjusted admissions, and research projects). Dynamic network data envelopment analysis uses carry-over variables (in the model, financing budget) to analyze frontier shift in subsequent years. Data were gathered from the information system of the Brazilian Ministry of Education (MEC), 2010-2013. RESULTS The mean scores for health care, teaching and research over the period were 58.0%, 86.0%, and 61.0%, respectively. In 2012, the best performance year, for all units to reach the frontier it would be necessary to have a mean increase of 65.0% in outpatient visits; 34.0% in admissions; 12.0% in undergraduate students; 13.0% in multi-professional residents; 48.0% in graduate students; 7.0% in research projects; besides a decrease of 9.0% in medical residents. In the same year, an increase of 0.9% in financing budget would be necessary to improve the care output frontier. In the dynamic evaluation, there was progress in teaching efficiency, oscillation in medical care and no variation in research. CONCLUSIONS The proposed model generates public health planning and programming parameters by estimating efficiency scores and making projections to reach the best practice frontier.
Resumo:
Trabalho apresentado no âmbito do Mestrado em Engenharia Informática, como requisito parcial para obtenção do grau de Mestre em Engenharia Informática
Resumo:
From each of a group of 217 adult males selected through enzyme-immunoassay or skin-test (Group A), six stool samples were examined by both the Lutz/Hoffman, Pons & Janer (Lutz/HPJ) and Kato/Katz methods. In addition, one oogram of the rectal mucosa was performed. By these methods, schistosomiasis was detected in 44.7%, 47.5% and 40.1% of the individuals respectively. To evaluate the methods in the assessment of cure, the last 40 patients from group A, treated with a single oral dose of oxamniquine at 15 mg/kg were followed up for six months (Group B). The criteria for parasitological cure included three stool examinations by Kato/Katz and Lutz/HPJ methods, one, three and six months post-treatment and a rectal biopsy between the fourth and sixth months post-treatment. The examinations were negative in 87.5%, 90% and 95% of the patients, respectively. The efficacy of oxamniquine was 82.5% when the three methods were considered together and there was no statistically significant difference between the sensitivity of the individual methods.
Resumo:
In Brazil, more than 500,000 new cases of malaria were notified in 1992. Plasmodium falciparum and P.vivax are the responsible species for 99.3% of the cases. For adequate treatment, precoce diagnosis is necessary. In this work, we present the results of the traditional Plasmodia detection method, thick blood film (TBF), and the results of alternative methods: Immunofluorescence assay (IFA) with polyclonal antibody and Quantitative Buffy Coat method (QBC)® in a well defined population groups. The analysis were done in relation to the presence or absence of malaria clinical symptoms. Also different classes of immunoglobulins anti-P.falciparum were quantified for the global analysis of the results, mainly in the discrepant results. We concluded that alternative methods are more sensitive than TBF and that the association of epidemiological, clinical and laboratory findings is necessary to define the presence of malaria.
Resumo:
Demand response has gain increasing importance in the context of competitive electricity markets environment. The use of demand resources is also advantageous in the context of smart grid operation. In addition to the need of new business models for integrating demand response, adequate methods are necessary for an accurate determination of the consumers’ performance evaluation after the participation in a demand response event. The present paper makes a comparison between some of the existing baseline methods related to the consumers’ performance evaluation, comparing the results obtained with these methods and also with a method proposed by the authors of the paper. A case study demonstrates the application of the referred methods to real consumption data belonging to a consumer connected to a distribution network.
Resumo:
Electric power networks, namely distribution networks, have been suffering several changes during the last years due to changes in the power systems operation, towards the implementation of smart grids. Several approaches to the operation of the resources have been introduced, as the case of demand response, making use of the new capabilities of the smart grids. In the initial levels of the smart grids implementation reduced amounts of data are generated, namely consumption data. The methodology proposed in the present paper makes use of demand response consumers’ performance evaluation methods to determine the expected consumption for a given consumer. Then, potential commercial losses are identified using monthly historic consumption data. Real consumption data is used in the case study to demonstrate the application of the proposed method.
Resumo:
To compare two yeast identification methods, i. e, the manual and the VITEK mechanical methods, 62 clinical samples from hemocultures and animal sources were analyzed. After identification as Candida yeasts by the VITEK method, the strains were recharacterized using manual assimilation methods and sugar fermentation tests. Our findings reveal 58% concurrent identification between the two methods for animal strains, and 51% for human hemoculture strains.
Resumo:
Asymptomatic Plasmodium infection is a new challenge for public health in the American region. The polymerase chain reaction (PCR) is the best method for diagnosing subpatent parasitemias. In endemic areas, blood collection is hampered by geographical distances and deficient transport and storage conditions of the samples. Because DNA extraction from blood collected on filter paper is an efficient method for molecular studies in high parasitemic individuals, we investigated whether the technique could be an alternative for Plasmodium diagnosis among asymptomatic and pauciparasitemic subjects. In this report we compared three different methods (Chelex®-saponin, methanol and TRIS-EDTA) of DNA extraction from blood collected on filter paper from asymptomatic Plasmodium-infected individuals. Polymerase chain reaction assays for detection of Plasmodium species showed the best results when the Chelex®-saponin method was used. Even though the sensitivity of detection was approximately 66% and 31% for P. falciparum and P. vivax, respectively, this method did not show the effectiveness in DNA extraction required for molecular diagnosis of Plasmodium. The development of better methods for extracting DNA from blood collected on filter paper is important for the diagnosis of subpatent malarial infections in remote areas and would contribute to establishing the epidemiology of this form of infection.
Resumo:
Currently there are several methods to extract bacterial DNA based on different principles. However, the amount and the quality of the DNA obtained by each one of those methods is highly variable and microorganism dependent, as illustrated by coagulase-negative staphylococci (CoNS) which have a thick cell wall that is difficult to lyse. This study was designed to compare the quality and the amount of CoNS DNA, extracted by four different techniques: two in-house protocols and two commercial kits. DNA amount and quality determination was performed through spectrophotometry. The extracted DNA was also analyzed using agarose gel electrophoresis and by PCR. 267 isolates of CoNS were used in this study. The column method and thermal lyses showed better results with regard to DNA quality (mean ratio of A260/280 = 1.95) and average concentration of DNA (), respectively. All four methods tested provided appropriate DNA for PCR amplification, but with different yields. DNA quality is important since it allows the application of a large number of molecular biology techniques, and also it's storage for a longer period of time. In this sense the extraction method based on an extraction column presented the best results for CoNS.
Resumo:
INTRODUCTION: Methicillin-Resistant Staphylococcus aureus (MRSA) presenting reduced susceptibility to vancomycin has been associated to therapeutic failure. Some methods used by clinical laboratories may not be sufficiently accurate to detect this phenotype, compromising results and the outcome of the patient. OBJECTIVES: To evaluate the performance of methods in the detection of vancomycin MIC values among clinical isolates of MRSA. MATERIAL AND METHODS: The Vancomycin Minimal Inhibitory Concentration was determined for 75 MRSA isolates from inpatients of Mãe de Deus Hospital, Porto Alegre, Brazil. The broth microdilution (BM) was used as the gold-standard technique, as well as the following methods: E-test® strips (BioMérieux), M.I.C.E® strips (Oxoid), PROBAC® commercial panel and the automated system MicroScan® (Siemens). Besides, the agar screening test was carried out with 3 µg/mL of vancomycin. RESULTS: All isolates presented MIC ≤ 2 µg/mL for BM. E-test® had higher concordance (40%) in terms of global agreement with the gold standard, and there was not statistical difference among E-test® and broth microdilution results. PROBAC® panels presented MICs, in general, lower than the gold-standard panels (58.66% major errors), while M.I.C.E.® MICs were higher (67.99% minor errors). CONCLUSIONS: For the population of MRSA in question, E-test® presented the best performance, although with a heterogeneous accuracy, depending on MIC values.