1000 resultados para Meio TCM
Resumo:
Acidic hydrolysis of samples is frequent in urinary 2,5-hexanodione determination. This hydrolysis should be performed under proper conditions, in order to avoid interference, such as the presence of 2,5-dimethylfurane and 2-acetylfurane. The results of the present work, as well as data from the literature, show that the use of non-polar or slightly polar chromatographic columns of 30 m length is an essential condition for 2,5-HD determination in an acid hydrolysed urine sample. In the same way the pH should be kept between 0.3 and 0.5. The mean concentrations of 2,5-HD in samples submitted to hydrolysis (0.50 ± 0.28 mg/g of creatinine) was about 3 times higher than those found in the samples without acid hydrolysis (0.19 ± 0.3 mg/g of creatinine).
Resumo:
Poly (ethylene) glycol (PEG) and bovine serum albumin (BSA), as additive agents, were used to enhance the activity of immobilized microbial lipase in organic solvent. Controlled pore silica (CPS) was selected as matrix and different immobilization procedures were evaluated: directly lipase binding on CPS and simultaneous addition of lipase and additive agent on the same support. The highest coupling yield (59.6%) was attained when the immobilization procedure was performed at lipase loading of 150 U/g support in the presence of PEG-1.500. This immobilized system was used in esterification reactions under repeated batch cycles and the biocatalyst half-life was found to increase 2.7 times when compared with the control.
Resumo:
The violence derived from crimes involving firearms represents one of the main concerns of society. For this reason modern techniques have emerged in forensic science to identify suspects at crime scenes. This work describes a methodology to identify residues present in the hands of suspect by using a high resolution inductively coupled plasma mass spectrometry and collection procedure based on ethylenediaminetetraacetic acid (EDTA) solution as a complexing agent in moistened swabs. In order to distinguish real gunshot residues from others types of residues present in the hand of suspect, ternary ratio per cent diagrams were developed for antimony (Sb), barium (Ba) and lead (Pb) detected on the hands of volunteers, before and immediately after shooting tests, revealing a remarkable difference in both situations.
Resumo:
In this study, the preparation of the xerogel anilinepropylsilica is reported. The ability of the xerogel for extracting Al(III), Cr(III) and Fe(III) from ethanol was investigated at 25 ºC. The xerogel adsorption capacities were obtained from the adsorption isotherms by using the batch method. Flame atomic absorption spectrometry (FAAS) was used to estimate the concentration of metal ions in solution. The adsorption affinity follows the series Cr(III) > Fe(III) > Al(III) and the maximum adsorption capacities of the metal ions were 0.61, 0.52 and 0.43 mmol g-1, respectively.
Resumo:
The construction and analytical evaluation of a coated graphite Al(III) ion-selective electrode, based on the ionic pair formed between the Al(F)n3-n anion and tricaprylylmethylammonium cation (Aliquat 336S) incorporated on a poly(vinylchloride) (PVC) matrix membrane are described. A thin membrane film of this ionic pair and dibutylphthalate (DBPh) in PVC was deposited directly on a cylindric graphite rod (2 cm length x 0.5 cm diameter) attached to the end of a glass tube using epoxy resin. The membrane solution was prepared by dissolving 40% (m/m) of PVC in 10 mL of tetrahydrofuran following addition of 45% (m/m) of DBPh and 15% (m/m) of the ionic pair. The effect of membrane composition, fluoride concentration, and several concomitants as potential interferences on the electrode response were investigated. The aluminium(III) ion-selective electrode showed a linear response ranging from 1.4 x 10-4 to 1.0 x 10-2 mol L-1, a detection limit of 4.0 x 10-5 mol L-1, aslope of -54.3±0.2mV dec-1 and a lifetime of more than 1 year (over 3000 determinations for each membrane). The slope indicates that the ion-selective electrode responds preferentially to the Al(F)4- species. Application of this electrode for the aluminium(III) determination in stomach anti-acid samples is reported.
Resumo:
Since 1992, the carbon paste electrodes modified with humic acids have been used for studying the behavior of metals in aqueous solutions. Many parameters influence the performance of the electrodes, such as the humic acid ratio, the nature of the humic acid, the accumulation time, the pH, the scan rate, and the preparation of the electrodes itself. There are various methos of preparing the electrodes. The goal of this paper is to review some of them. The advantages of using electrodes modified with humic acids as electrochemical sensors for evaluating metals in aqueous solution are stressed.
Resumo:
Passive films formed in bicarbonate solutions on carbon steel, chromium steel and high speed steel have been characterized by XPS. The passive films formed on chromium and high speed steels showed superior protective properties than those formed on carbon steel. It was confirmed by XPS that the steel composition influences the passive film composition. Chromium oxide and hydroxide, as well as molybdenum and tungsten oxides and hydroxides are present in the passive film of chromium steel and high speed steel, respectively, besides iron oxide and hydroxide. The more complex composition of the oxide film on high speed steel explains its electrochemical behaviour and highest corrosion resistance.
Resumo:
The tanning process in the leather industry generates very high quantities of chromium-containing solid waste ("wet blue" leather). Environmental concerns and escalating landfill-costs are becoming increasingly serious problems for the leather industry and an alternative disposal is needed. In this work, we are presenting a novel application for this solid waste, which is the removal of organic contaminants from aqueous-solution. The adsorption isotherm of "wet blue" leather waste from the AUREA tanning company in Erechim-RS (Brazil) showed that this material presents high adsorption capacities of the reactive textile dyes.
Resumo:
This paper describes the separation of CO2 from a gas mixture containing 25% CO2, 4% O2 and 71% N2 using the pressure swing adsorption (PSA) technique. The adsorbent selected was the zeolite 13X due to its great adsorption capacity for CO2 and selectivity towards the other components of the gas mixture. The experimental technique was designed to identify the most important variables for the process and to optimize it. It is shown that the PSA technique can be used to separate CO2 from O2 and N2 to obtain an effluent containing 2% CO2 with 99% separation efficiency.
Resumo:
The construction and analytical evaluation of a coated graphite-epoxy electrode sensitive to the zinc-1,10-phenantroline complex based on the [Zn(fen)3][tetrakis(4-chlorophenyl)borate]2 incorporated into a poly(vinylchloride) (PVC) matrix are described. A thin membrane film of this ion-pair, dibutylphthalate (DBPh) and PVC were deposited directly onto an electrically conductive graphite-epoxy support located inside a Perspex® tube. The best PVC polymeric membrane contains 65% (m/m) DBPh, 30% (m/m) PVC and 5% (m/m) of the ion-pair. This electrode shows a response of 19.5 mV dec-1 over the zinc(II) concentration range of 1.0 x 10-5 to 1.0 x 10-3 mol L-1 in 1,10-phenantroline medium, at pH 6.0. The response time was less than 20 seconds and the lifetime of this electrode was more than four months (over 1200 determinations by each polymeric membrane). It was successfully used as an indicator electrode in the potentiometric precipitation titration of zinc(II) ions.
Resumo:
UV-Vis and fluorescence spectroscopic studies of the native and reconstituted d monomers of Glossoscolex paulistus were performed in acid medium. The coexistence of distinct species shows the complexity of the equilibria. Besides the hexacoordinate low spin hemichrome, with bands at 535 and 565 nm, a pentacoordinate high spin hemichrome is identified by the blue-shifted low intensity Soret band (371 nm) and the LMCT band (643 nm). The pentacoordinate hemichrome must be related to the partial unfolding of the polypeptide.
Resumo:
Adsorptive stripping voltammetry carried out in a homogeneous ternary solvent composed of N,N-dimethylformamide, water and ethanol, with alpha-benzoinoxime (alphaBO) as the complexing agent for Mo(VI) and a 0.5 mol L-1 acetic acid - sodium acetate buffer as supporting electrolyte was successfully used for the determination of molybdenum in polyvitamin-polymineral tablets. Tablet samples were analyzed and the results were compared with those obtained both by graphite furnace atomic absorption and by recovery tests, with good correlations, indicating that this may be considered as an alternative procedure for routine determination of Mo(VI) in pharmaceutical samples.
Resumo:
Inductively Coupled Plasma Optical Emission Spectrometry was used to determine Ca, Mg, Mn, Fe, Zn and Cu in samples of processed and natural coconut water. The sample preparation consisted in a filtration step followed by a dilution. The analysis was made employing optimized instrumental parameters and the results were evaluated using methods of Pattern Recognition. The data showed common concentration values for the analytes present in processed and natural samples. Principal Component Analysis (PCA) and Hierarchical Cluster Analysis (HCA) indicated that the samples of different kinds were statistically different when the concentrations of all the analytes were considered simultaneously.
Resumo:
UV-Vis and fluorescence spectroscopic studies of native and reconstituted d monomers from Glossoscolex paulistus were performed in alkaline pH. In addition to the presence of aquomet and hemichrome hexacoordinated species, a pentacoordinated species occurs. This latter species, which presents an imidazolate group of axial histidine as fifth ligand, is identified by the blue-shifted low-intensity Soret band and LMCT band. The pentacoordinated species must occur due to partial polypeptide unfolding.