977 resultados para MEAN MAGNETIC-FIELD
Resumo:
We use the Ogg-McCombe Hamiltonian together with the Dresselhaus and Rashba spin-splitting terms to find the g factor of conduction electrons in GaAs-(Ga,Al)As semiconductor quantum wells (QWS) (either symmetric or asymmetric) under a magnetic field applied along the growth direction. The combined effects of non-parabolicity, anisotropy and spin-splitting terms are taken into account. Theoretical results are given as functions of the QW width and compared with available experimental data and previous theoretical works. © 2007 Elsevier B.V. All rights reserved.
Resumo:
Measurements of the coefficient of thermal expansion on the spin-liquid candidate κ-(BEDT-TTF) 2Cu 2(CN) 3 have revealed distinct and strongly anisotropic lattice effects around 6 K - a possible spin liquid instability. In order to study the effects of a magnetic field on the low-temperature spin-liquid state, dilatometric measurements have been conducted both as a function of temperature at B = const. and as a function of field at T = const. While the 6 K anomaly is found to be insensitive to magnetic fields B ≤ 10 T, the maximum field applied, surprisingly strong B -induced effects are observed for magnetic fields applied along the in-plane b-axis. Above a threshold field of 0.5 T < B c ≤ 1 T, a jump-like anomaly is observed in the b-axis lattice parameter. This anomaly, which is located at 8.7 K at B = 1 T, grows in size and shifts to lower temperatures with increasing the magnetic field. Although the anomaly bears resemblance to a first-order phase transition, the lack of hysteresis suggests otherwise. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Resumo:
Purpose. We quantified the main sequence of spontaneous blinks in normal subjects and Graves' disease patients with upper eyelid retraction using a nonlinear and two linear models, and examined the variability of the main sequence estimated with standard linear regression for 10-minute periods of time. Methods. A total of 20 normal subjects and 12 patients had their spontaneous blinking measured with the magnetic search coil technique when watching a video during one hour. The main sequence was estimated with a power-law function, and with standard and trough the origin linear regressions. Repeated measurements ANOVA was used to test the mean sequence stability of 10-minute bins measured with standard linear regression. Results. In 95% of the sample the correlation coefficients of the main sequence ranged from 0.60 to 0.94. Homoscedasticity of the peak velocity was not verified in 20% of the subjects and 25% of the patients. The power-law function provided the best main sequence fitting for subjects and patients. The mean sequence of 10-minute bins measured with standard linear regression did not differ from the one-hour period value. For the entire period of observation and the slope obtained by standard linear regression, the main sequence of the patients was reduced significantly compared to the normal subjects. Conclusions. Standard linear regression is a valid and stable approximation for estimating the main sequence of spontaneous blinking. However, the basic assumptions of the linear regression model should be examined on an individual basis. The maximum velocity of large blinks is slower in Graves' disease patients than in normal subjects. © 2013 The Association for Research in Vision and Ophthalmology, Inc.
Resumo:
A hybrid magnetic instrumentation to detect a magnetic field from a permanent magnet, and to detect magnetic markers and tracers using alternating current biosusceptometry (ACB) is discussed. The instrument was used to in vitro evaluation of the esophageal transit time. The sensitivity between both magnetic methods was compared, showing sensitivity for in vivo applications. © 2013 Springer-Verlag.
Resumo:
Considerando que o número de dados paleomagnéticos para o Paleozóico Superior, principalmente Devoniano da América do Sul, é ainda insuficiente não permitindo que uma Curva de Deriva Polar confiável possa ser construída, foram amostrados 43 níveis estratigráficos da Formação Longá, os quais foram estudados paleomagneticamente com o propósito de contribuir para que uma Curva mais confiável possa ser construída. A amostragem foi feita segundo o método dos blocos ao longo dos perfis Teresina, Barras, Batalha, na rodovia PI-13 e Floriano, Nazaré do Piauí, Oeiras nas rodovias PI-24 e BR-230, no estado do Piauí. Os tratamentos foram iniciados no laboratório de Paleomagnetismo do IAG-USP e complementados no do NCGG-UFPa. Utilizou-se as técnicas de desmagnetização progressiva por campos alternados até 700 e/ou temperaturas até 670-700ºC. A interpretação dos resultados foi feita por meio dos diagramas vetoriais de Zijderveld, pelas curvas J-T/C de variação da intensidade magnética com os campos ou temperaturas, e pelos gráficos de variação na direção do vetor magnetização. Os cálculos de direção média e polos foram feitos segundo a Estatística de Fisher (1953). Foram identificadas 4 direções de magnetização remanente: 1. Uma secundária de origem química (CRM) e polaridade reversa, cujo mineral responsável é a hematita produzida provavelmente por alteração deutérica a partir da magnetita. Esta magnetização (identificada pela letra B) quando datada paleomagneticamente (coordenadas do polo 80ºS, 3°E, A95 = 13.6°) indicou idade correspondente ao intervalo Carbonífero-Permiano. 2. Uma componente isotérmica (IRM) dura de espectro totalmente superposto à magnetização inicial que não foi afetada por nenhum dos tratamentos. Esta magnetização foi denominada D e apresentou direção muito estável em torno do ponto de declinação = 234.23º e inclinação = 41.94º. 3. Um grupo de direções de magnetização de origem viscosa (VRM) moles, identificados pela letra C, cuja direção média é dada por: declinação = 15º e inclinação = -20º. Foram removidas a temperatura entre 300 – 600ºC. 4. Finalmente uma magnetização principal, de polaridade normal, denominada A, provavelmente de origem detrítica (DRM) cujo correspondente polo paleomagnético (de coordenadas: 48ºS, 331.7ºE; A95 = 9.9º) mostrou-se compatível com a idade da Formação (Devoniano Superior). Esta magnetização foi considerada inicial. Os polos paleomagnéticos correspondentes às magnetizações A e B, juntamente com outros da América do Sul, foram rotacionados para a África segundo a configuração pré-deriva de Smith e Hallam (1970) e comparados a polos Africanos e Australianos de mesma idade, mostrando-se coerentes. Suas polaridades também estão em acordo com as escalas magnetoestratigráficas publicadas por Irving e Pullaiah (1976) e Khramov e Rodionov (1981).
Resumo:
Pós-graduação em Ciências Farmacêuticas - FCFAR
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The main idea of this work is to understand and analyze the dynamical aspects of the motion of a particle moving in the annular billiard, which corresponds to two circles of radius R and r (r
Resumo:
Nanotherapy applied to cancer treatment is constantly evolving, and new approaches to current techniques, such as magnetohyperthermia, are being implemented to solve and minimize the limitations of conventional therapeutic strategies. The purpose of this study was to investigate the action of polyphosphate-coated maghemite nanoparticles (MNPs) on oral squamous cell carcinoma. Human oral cancer cells (UM-SCC14A) were incubated with MNPs at various concentrations and subjected to cell proliferation tests (MTT), apoptosis assays and transmission electron image analysis. Viability and apoptotic events were time and dose dependent. These in vitro tests showed that at the intermediate concentration tested there is no significant toxicity, as confirmed by transmission electron microscopy. For this reason this MNPs concentration was chosen for the subsequent in vivo tests. Oral tumor induction was performed by applying the carcinogen DMBA to Syrian hamsters. Animals were then treated by magnetohyperthermia using MNPs. No signs of general clinical symptoms of toxicity or abnormal behavioral reactions were observed. However, animals treated with MNPs and exposed to the alternating magnetic field in the hyperthermia procedure exhibited a significant and time dependent cancer regression, as confirmed by histopathological analyses and immunohistochemistry. Actually, in quantitative terms of the magnetotherapy efficacy involving these polyphosphate-coated MNPs, 100% recovery (12/12) was observed in the oral cancer tumor bearing Syrian hamsters seven days after the treatment with the magnetohyperthermia procedure. Data supports the suggestion that the MNPs-mediated hyperthermia represents a promising strategy for the treatment of oral cancer.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The Carr-Purcell-Meiboom-Gill (CPMG) pulse sequence has been used in many applications of magnetic resonance imaging (MRI) and low-resolution NMR (LRNMR) spectroscopy. Recently. CPMG was used in online LRNMR measurements that use long RF pulse trains, causing an increase in probe temperature and, therefore, tuning and matching maladjustments. To minimize this problem, the use of a low-power CPMG sequence based on low refocusing pulse flip angles (LRFA) was studied experimentally and theoretically. This approach has been used in several MRI protocols to reduce incident RF power and meet the specific absorption rate. The results for CPMG with LRFA of 3 pi/4 (CPMG(135)), pi/2 (CPMG(90)) and pi/4 (CPMG(45)) were compared with conventional CPMG with refocusing pi pulses. For a homogeneous field, with linewidth equal to Delta nu = 15 Hz, the refocusing flip angles can be as low as pi/4 to obtain the transverse relaxation time (T(2)) value with errors below 5%. For a less homogeneous magnetic field. Delta nu = 100 Hz, the choice of the LRFA has to take into account the reduction in the intensity of the CPMG signal and the increase in the time constant of the CPMG decay that also becomes dependent on longitudinal relaxation time (T(1)). We have compared the T(2) values measured by conventional CPMG and CPMG(90) for 30 oilseed species, and a good correlation coefficient, r = 0.98, was obtained. Therefore, for oilseeds, the T(2) measurements performed with pi/2 refocusing pulses (CPMG(90)), with the same pulse width of conventional CPMG, use only 25% of the RF power. This reduces the heating problem in the probe and reduces the power deposition in the samples. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
Amazonian gold mining activity results in human exposure to mercury vapor. We evaluated the visual system of two Amazonian gold miners (29 and 37 years old) by recording the transient pattern electroretinogram (tPERG) and transient pattern visual evoked potential (tPVEP). We compared these results with those obtained from a regional group of control subjects. For both tPERG and tPVEP, checkerboards with 0.5 or 2 cycles per degree (cpd) of spatial frequency were presented in a 16 degrees squared area, 100% Michelson contrast, 50cd/m(2) mean luminance, and 1 Hz square-wave pattern-reversal presentation. Two averaged waveforms (n = 240 sweeps, Is each) were monocularly obtained for each subject in each condition. Both eyes were monocularly tested only in gold miners. Normative data were calculated using a final pooled waveforin with 480 sweeps. The first gold miner, LCS, had normal tPERG responses. The second one, RNP, showed low tPERG (P50 component) amplitudes at 0.5cpd for both eyes, outside the normative data, and absence of response at 2 cpd for his right eye. Delayed tPVEP responses (P 100 component) were found at 2 cpd for LCS but the implicit times were inside the normative data. Subject RNP also showed delayed tPVEP responses (all components), but only the implicit time obtained with his right eye was outside the normative data at 2cpd. We conclude that mercury exposure levels found in the Amazon gold miners is high enough to damage the visual system and can be assessed by non-invasive electrophysiological techniques. (C) 2007 Elsevier Inc. All rights reserved.