856 resultados para Lithium fluoride
Resumo:
This study evaluated the capacity of fluoride acidic dentifrices (pH 4.5) to promote enamel remineralization using a pH cycling model, comparing them with a standard dentifrice (1,100 µgF/g). Enamel blocks had their surface polished and surface hardness determined (SH). Next, they were submitted to subsurface enamel demineralization and to post-demineralization surface hardness analysis. The blocks were divided into 6 experimental groups (n=10): placebo (without F, pH 4.5, negative control), 275, 412, 550, 1,100 µgF/g and a standard dentifrice (positive control). The blocks were submitted to pH cycling for 6 days and treatment with dentifrice slurries twice a day. After pH cycling, surface and cross-sectional hardness were assessed to obtain the percentage of surface hardness recovery (%SHR) and the integrated loss of subsurface hardness (ΔKHN). The results showed that %SHR was similar among acidic dentifrices with 412, 550, 1,100 µgF/g and to the positive control (Tukey's test; p>0.05). For ΔKHN, the acidic dentifrice with 550 µg F/g showed a better performance when compared with the positive control. It can be concluded that acidic dentifrice 550 µgF/g had similar remineralization capacity to that of positive control.
Resumo:
Fluoridation of the public water supplies is recognized as among the top ten public health achievements of the twentieth century. However, the positive aspects of this measure depend on the maintenance of fluoride concentrations within adequate levels. To report the results of seven years of external control of the fluoride (F) concentrations in the public water supply in Bauru, SP, Brazil in an attempt to verify, on the basis of risk/benefit balance, whether the levels are appropriate. From March 2004 to February 2011, 60 samples were collected every month from the 19 supply sectors of the city, totaling 4,641 samples. F concentrations in water samples were determined in duplicate, using an ion-specific electrode (Orion 9609) coupled to a potentiometer after buffering with TISAB II. After the analysis, the samples were classified according to the best risk-benefit adjustment. Means (±standard deviation) of F concentrations ranged between 0.73±0.06 and 0.81±0.10 mg/L for the different sectors during the seven years. The individual values ranged between 0.03 and 2.63 mg/L. The percentages of the samples considered “low risk” for dental fluorosis development and of “maximum benefit” for dental caries prevention (0.55-0.84 mg F/L) in the first, second, third, fourth, fifth, sixth, and seventh years of the study were 82.0, 58.5, 37.4, 61.0, 89.9, 77.3, and 72.4%, respectively, and 69.0% for the entire period. Fluctuations of F levels were found in the public water supply in Bauru during the seven years of evaluation. These results suggest that external monitoring of water fluoridation by an independent assessor should be implemented in cities where there is adjusted fluoridation. This measure should be continued in order to verify that fluoride levels are suitable and, if not, to provide support for the appropriate adjustments
Resumo:
Background & aims: To identify manufactured soy-based products more recommended by pediatricians and nutritionists; to determine fluoride concentrations in these products; to evaluate children concerning fluorosis in primary teeth and its association with the consumption of soy-based products. Methods: Pediatricians and Nutritionists answered a questionnaire about soy-based products they most recommended to children. Fluoride concentrations of the 10 products more cited were analyzed with the ion-specific electrode. Dental fluorosis exams were performed in 315 4e6-year-old children. Dean’s Index was used to assess fluorosis. Among the children examined, 26 had lactose intolerance. Their parents answered a questionnaire about children’s and family’s profile, besides permitting the identification of soy-based products use. Chi-squared and Multivariable Logistic Regression tests were used (p < 0.05). Results: Fluoride content in the analyzed products ranged from 0.03 to 0.50 mg F /mL. Dental fluorosis was detected in 11% of the children, with very mild and mild degrees. Dental fluorosis in primary teeth was associated with lactose intolerance (p < 0.05), but there was no significant association with the use of manufactured soy-based products. Conclusions: Isolated consumption of soy-based products recommended by health professionals to children do not offer risk of dental fluorosis in primary teeth, which had a low prevalence and severity.
Impact of different fluoride concentrations and pH of dentifrices on tooth erosion/abrasion in vitro
Resumo:
Background: This in vitro study analysed the effect of different fluoride concentrations in acidic or neutral liquid dentifrices in protecting enamel and dentine from erosive and abrasive wear. Methods: Bovine enamel and dentine specimens (n = 132) were randomly allocated to 11 groups (each n = 12): experimental liquid dentifrices with 550 ppm F, 1100 ppm F, 5000 ppm F or 0 ppm F/placebo (each at pH 4.5 and pH 7.0); and commercial dentifrices with 550 ppm F (Colgate Baby, pH 7.0), 1100 ppm F (Crest, pH 7.0) and 5000 ppm F (Duraphat, pH 7.0). The specimens were subjected to erosion for 90 seconds, 4 times/day, over 7 days. Immediately after the first and last erosion, the specimens were brushed for 15 seconds using one of the dentifrices. Tooth wear was measured profilometrically (lm) and analysed by ANOVA (p < 0.05). Results: All fluoridated liquid dentifrices significantly reduced enamel wear compared to the placebo and commercial dentifrices. Only liquid dentifrices with 1100 and 5000 ppm F significantly reduced dentine wear compared to placebo dentifrice. The pH had no effect, but the consistency had a significant impact on the effect of dentifrices. Conclusions: Liquid dentifrices with high F concentration appear to be a good option to prevent tooth wear
Resumo:
Most studies dealing with the caries preventive action of Nd:YAG laser have been done in permanent teeth and studies on primary teeth are still lacking. The aim of this study was to evaluate in vitro the effect of Nd:YAG laser combined or not with fluoride sources on the acid resistance of primary tooth enamel after artificial caries induction by assessing longitudinal microhardness and demineralization depth. Sixty enamel blocks obtained from the buccal/lingual surface of exfoliated human primary molars were coated with nail polish/wax, leaving only a 9 mm² area exposed on the outer enamel surface, and randomly assigned to 6 groups (n=10) according to the type of treatment: C-control (no treatment); APF: 1.23% acidulated phosphate fluoride gel; FV: 5% fluoride varnish; L: Nd:YAG laser 0.5 W/10 Hz in contact mode; APFL: fluoride gel + laser; FVL: fluoride varnish + laser. After treatment, the specimens were subjected to a des-remineralization cycle for induction of artificial caries lesions. Longitudinal microhardness data (%LMC) were analyzed by the Kruskal-Wallis test and demineralization depth data were analyzed by oneway ANOVA and Fisher’s LSD test (á=0.05). APFL and APF groups presented the lowest percentage of microhardness change (p<0.05). Demineralization depth was smaller in all treated groups compared with the untreated control. In conclusion, Nd:YAG laser combined or not with fluoride gel/varnish was not more effective than fluoride alone to prevent enamel demineralization within the experimental period.
Resumo:
The effects of fluoride, which is present in different oral hygiene products, deserve more investigation because little is known about their impact on the surface of titanium, which is largely used in Implantology. This study evaluated the surface of commercially pure titanium (cpTi) after exposure to different concentrations of sodium fluoride (NaF). The hypothesis tested in this study was that different concentrations of NaF applied at different time intervals can affect the titanium surface in different ways. The treatments resulted in the following groups: GA (control): immersion in distilled water; GB: immersion in 0.05% NaF for 3 min daily; GC: immersion in 0.2% NaF for 3 min daily; GD: immersion in 0.05% NaF for 3 min every 2 weeks; and GE: immersion in 0.2% NaF for 3 min every 2 weeks. The experiment lasted 60 days. Roughness was measured initially and every 15 days subsequently up to 60 days. After 60 days, corrosion analysis and anodic polarization were done. The samples were examined by scanning electron microscopy (SEM). The roughness data were analyzed by ANOVA and there was no significant difference among groups and among time intervals. The corrosion data (i corr) were analyzed by the Mann-Whitney test, and significant differences were found between GA and GC, GB and GC, GC and GD, GC and GE. SEM micrographs showed that the titanium surface exposed to NaF presented corrosion that varied with the different concentrations. This study suggests that the use of 0.05% NaF solution on cpTi is safe, whereas the 0.2% NaF solution should be carefully evaluated with regard to its daily use.
Resumo:
This study evaluated the influence of fluoride on cell viability and activity of matrix metalloproteinases (MMP) -2 and -9 secreted by preosteoblasts. Preosteoblasts (MC3T3-E1 murine cell line) were cultured in MEM medium supplement with 10% Fetal Bovine Serum (FBS) and nucleosides/ribonucleosides without ascorbic acid. Adherent cells were treated with different concentrations of F (as sodium fluoride-NaF) in medium (5 x 10-6 M, 10-5 M, 10-4 M and 10-3 M) for 24, 48, 72 and 96 h at 37ºC, 5% CO2. Control cells were cultivated in MEM only. After each period, preosteoblast viability was assessed by MTT assay. MMP-2 and -9 activities were performed by gel zymography. Also, alkaline phosphatase (ALP) activity was quantified by colorimetry in all experimental groups. It was shown that cultured cells with the highest dose of F (10-3 M) for 96 h decreased preosteoblast viability while lower doses of F did not alter it, when compared to untreated cells. No differences were observed in ALP activity among groups. Moreover, compared to control, the treatment of cells with F at low dose slightly increased MMP-2 and -9 activities after 24 h. It was concluded that F modulates preosteoblast viability in a dose-dependent manner and also may regulate extracellular matrix remodeling.
Resumo:
[EN]This paper presents our research about nucleation and its dependency with external conditions, as well as the internal characteristics of the solution itself. Among the research lines of our group, we has been studying the influence of electric fields over two different but related compounds: Lithium-Potassium Sulfate and Lithium-Amonium Sulfate, which both of them show a variation on the nucleation ratio when an electric field is applied during the crystal growth. Moreover, in this paper will be explained a laboratory protocol to teach universitary Science students the nucleation process itself and how it depends on external applied conditions, e.g. electric fields.
Resumo:
The separator membrane in batteries and fuel cells is of crucial importance for the function of these devices. In lithium ion batteries the separator membrane as well as the polymer matrix of the electrodes consists of polymer electrolytes which are lithium ion conductors. To overcome the disadvantage of currently used polymer electrolytes which are highly swollen with liquids and thus mechanically and electrochemically unstable, the goal of this work is a new generation of solid polymer electrolytes with a rigid backbone and a soft side chain structure. Moreover the novel material should be based on cheap substrates and its synthesis should not be complicated aiming at low overall costs. The new materials are based on hydroxypropylcellulose and oligoethyleneoxide derivatives as starting materials. The grafting of the oligoethyleneoxide side chains onto the cellulose was carried out following two synthetic methods. One is based on a bromide derivative and another based on p-toluolsulfonyl as a leaving group. The side chain reagents were prepared form tri(ethylene glycol) monoethyl ether. In order to improve the mechanical properties the materials were crosslinked. Two different conceptions have been engaged based on either urethane chemistry or photosensitive dimethyl-maleinimide derivatives. PEO - graft - cellulose derivatives with a high degree of substitution between 2,9 and 3,0 were blended with lithium trifluoromethane-sulfonate, lithium bis(trifluorosulfone)imide and lithium tetrafluoroborate. The molar ratios were in the range from 0,02 to 0,2 [Li]/[O]. The products have been characterized with nuclear magnetic resonance (NMR), gel permeation chromatography (GPC) and laserlight scattering (LS) with respect to their degree of substitution and molecular weight. The effect of salt concentration on ionic conductivity, thermal behaviour and morphology has been investiga-ted with impedance spectroscopy, differential scanning calorimetry (DSC) and thermal gravimetric analysis (TGA). The crosslinking reactions were controlled with dynamic mechanical analysis (DMS). The degree of substitution of our products is varying between 2,8 and 3,0 as determined by NMR. PEO - graft - cellulose derivatives are highly viscous liquids at room temperature with glass transition temperatures around 215 K. The glass transition temperature for the Lithium salt complexes of PEO - graft - cellulose deri-vatives increase with increasing salt content. The maximum conductivity at room temperature is about 10-4 and at 100°C around 10-3 Scm-1. The presence of lithium salt decreases the thermal stability of the complexes in comparison to pure PEO - graft - cellulose derivatives. Complexes heated over 140 – 150°C completely lose their ionic conductivity. The temperature dependence of the conductivity presented as Arrhenius-type plots for all samples is similar in shape and follows a VTF behaviour. This proofs that the ionic transport is closely related to the segmental motions of the polymer chains. Novel cellulose derivatives with grafted oligoethylen-oxide side chains with well-defined chemical structure and high side chain grafting density have been synthesized. Cellulose was chosen as stiff, rod like macromolecule for the backbone while oligoethylen-oxides are chosen as flexible side chains. A maximum grafting density of 3.0 have been obtained. The best conductivity reaches 10-3 Scm-1 at 100°C for a Li-triflate salt complex with a [Li]/[O] ratio of 0.8. The cross-linked complexes containing the lithium salts form elastomeric films with convenient mechanical stability. Our method of cellulose modification is based on relatively cheap and commercially available substrates and as such appears to be a promising alternative for industrial applications.
Resumo:
The worldwide demand for a clean and low-fuel-consuming transport promotes the development of safe, high energy and power electrochemical storage and conversion systems. Lithium-ion batteries (LIBs) are considered today the best technology for this application as demonstrated by the recent interest of automotive industry in hybrid (HEV) and electric vehicles (EV) based on LIBs. This thesis work, starting from the synthesis and characterization of electrode materials and the use of non-conventional electrolytes, demonstrates that LIBs with novel and safe electrolytes and electrode materials meet the targets of specific energy and power established by U.S.A. Department of Energy (DOE) for automotive application in HEV and EV. In chapter 2 is reported the origin of all chemicals used, the description of the instruments used for synthesis and chemical-physical characterizations, the electrodes preparation, the batteries configuration and the electrochemical characterization procedure of electrodes and batteries. Since the electrolyte is the main critical point of a battery, in particular in large- format modules, in chapter 3 we focused on the characterization of innovative and safe electrolytes based on ionic liquids (characterized by high boiling/decomposition points, thermal and electrochemical stability and appreciable conductivity) and mixtures of ionic liquid with conventional electrolyte. In chapter 4 is discussed the microwave accelerated sol–gel synthesis of the carbon- coated lithium iron phosphate (LiFePO 4 -C), an excellent cathode material for LIBs thanks to its intrinsic safety and tolerance to abusive conditions, which showed excellent electrochemical performance in terms of specific capacity and stability. In chapter 5 are presented the chemical-physical and electrochemical characterizations of graphite and titanium-based anode materials in different electrolytes. We also characterized a new anodic material, amorphous SnCo alloy, synthetized with a nanowire morphology that showed to strongly enhance the electrochemical stability of the material during galvanostatic full charge/discharge cycling. Finally, in chapter 6, are reported different types of batteries, assembled using the LiFePO 4 -C cathode material, different anode materials and electrolytes, characterized by deep galvanostatic charge/discharge cycles at different C-rates and by test procedures of the DOE protocol for evaluating pulse power capability and available energy. First, we tested a battery with the innovative cathode material LiFePO 4 -C and conventional graphite anode and carbonate-based electrolyte (EC DMC LiPF 6 1M) that demonstrated to surpass easily the target for power-assist HEV application. Given that the big concern of conventional lithium-ion batteries is the flammability of highly volatile organic carbonate- based electrolytes, we made safe batteries with electrolytes based on ionic liquid (IL). In order to use graphite anode in IL electrolyte we added to the IL 10% w/w of vinylene carbonate (VC) that produces a stable SEI (solid electrolyte interphase) and prevents the graphite exfoliation phenomenon. Then we assembled batteries with LiFePO 4 -C cathode, graphite anode and PYR 14 TFSI 0.4m LiTFSI with 10% w/w of VC that overcame the DOE targets for HEV application and were stable for over 275 cycles. We also assembled and characterized ―high safety‖ batteries with electrolytes based on pure IL, PYR 14 TFSI with 0.4m LiTFSI as lithium salt, and on mixture of this IL and standard electrolyte (PYR 14 TFSI 50% w/w and EC DMC LiPF 6 50% w/w), using titanium-based anodes (TiO 2 and Li 4 Ti 5 O 12 ) that are commonly considered safer than graphite in abusive conditions. The batteries bearing the pure ionic liquid did not satisfy the targets for HEV application, but the batteries with Li 4 Ti 5 O 12 anode and 50-50 mixture electrolyte were able to surpass the targets. We also assembled and characterized a lithium battery (with lithium metal anode) with a polymeric electrolyte based on poly-ethilenoxide (PEO 20 – LiCF 3 SO 3 +10%ZrO 2 ), which satisfied the targets for EV application and showed a very impressive cycling stability. In conclusion, we developed three lithium-ion batteries of different chemistries that demonstrated to be suitable for application in power-assist hybrid vehicles: graphite/EC DMC LiPF 6 /LiFePO 4 -C, graphite/PYR 14 TFSI 0.4m LiTFSI with 10% VC/LiFePO 4 -C and Li 4 T i5 O 12 /PYR 14 TFSI 50%-EC DMC LiPF 6 50%/LiFePO 4 -C. We also demonstrated that an all solid-state polymer lithium battery as Li/PEO 20 –LiCF 3 SO 3 +10%ZrO 2 /LiFePO 4 -C is suitable for application on electric vehicles. Furthermore we developed a promising anodic material alternative to the graphite, based on SnCo amorphous alloy.
Resumo:
Nuclear charge radii of short-lived isotopes can be probed in a nuclear-model independent way via isotope shift measurements. For this purpose a novel technique was developed at GSI, Darmstadt. It combines two-photon laser spectroscopy in the 2s-3s electronic transition of lithium, resonance ionization, and detection via quadrupole mass spectrometry. In this way an accuracy of 5e-5 which is necessary for the extraction of nuclear charge radii, and an overall detection efficiency of 1e-4 is reached. This allowed an isotope shift measurement of Li-11 for the first time at the TRIUMF facility in Vancouver. Additionally, uncertainties in the isotope shift for all other lithium isotopes were reduced by about a factor of four compared to previous measurements at GSI. Results were combined with recent theoretical mass shift calculations in three-electron systems and root-mean-square nuclear charge radii of all lithium isotopes, particulary of the two-neutron halo nucleus Li-11, were determined. Obtained charge radii decrease continuously from Li-6 to Li-9, while a strong increase between Li-9 and Li-11 is observed. This is compared to predictions of various nuclear models and it is found that a multicluster model gives the best overall agreement. Within this model, the increase in charge radius between Li-9 and Li-11is to a large extend caused by intrinsic excitation of the Li-9-like core while the neutron-halo correlation contributes only to a small extend.
Resumo:
The subject of the presented thesis is the accurate measurement of time dilation, aiming at a quantitative test of special relativity. By means of laser spectroscopy, the relativistic Doppler shifts of a clock transition in the metastable triplet spectrum of ^7Li^+ are simultaneously measured with and against the direction of motion of the ions. By employing saturation or optical double resonance spectroscopy, the Doppler broadening as caused by the ions' velocity distribution is eliminated. From these shifts both time dilation as well as the ion velocity can be extracted with high accuracy allowing for a test of the predictions of special relativity. A diode laser and a frequency-doubled titanium sapphire laser were set up for antiparallel and parallel excitation of the ions, respectively. To achieve a robust control of the laser frequencies required for the beam times, a redundant system of frequency standards consisting of a rubidium spectrometer, an iodine spectrometer, and a frequency comb was developed. At the experimental section of the ESR, an automated laser beam guiding system for exact control of polarisation, beam profile, and overlap with the ion beam, as well as a fluorescence detection system were built up. During the first experiments, the production, acceleration and lifetime of the metastable ions at the GSI heavy ion facility were investigated for the first time. The characterisation of the ion beam allowed for the first time to measure its velocity directly via the Doppler effect, which resulted in a new improved calibration of the electron cooler. In the following step the first sub-Doppler spectroscopy signals from an ion beam at 33.8 %c could be recorded. The unprecedented accuracy in such experiments allowed to derive a new upper bound for possible higher-order deviations from special relativity. Moreover future measurements with the experimental setup developed in this thesis have the potential to improve the sensitivity to low-order deviations by at least one order of magnitude compared to previous experiments; and will thus lead to a further contribution to the test of the standard model.
Resumo:
Die vorliegende Dissertation befasst sich mit der Synthese, physikochemischen und polymerspezifischen Charakterisierung und insbesondere der impedanzspektroskopischen Untersuchung von sowohl neuartigen, solvensfreien lithiumionen- als auch protonenleitfähigen Polymermaterialien für potentielle Anwendungen in sekundären Lithiumionenbatterien bzw. in Hochtemperatur-Protonenaustauschmembran-Brennstoffzellen (engl.: proton exchange membrane fuel cell, auch: polymer electrolyte membrane fuel cell, PEMFC). Beiden Typen von ionenleitfähigen Membranen liegt das gängige Prinzip der chemischen Anbindung einer für den Ionentransport verantwortlichen Seitengruppe an eine geeignete Polymerhauptkette zugrunde („Entkopplung“; auch Immobilisierung), welcher hinsichtlich Glasübergangstemperatur (Tg), elektrochemischer und thermischer Stabilität (Td) eine dynamisch entkoppelte, aber nicht minder bedeutsame Rolle zukommt. Die Transportaktivierung erfolgt in beiden Fällen thermisch. Im Falle der Protonenleiter liegt die zusätzliche Intention darin, eine Alternative aufzuzeigen, in der die Polymerhauptkette gekoppelt direkt am Protonentransportmechanismus beteiligt ist, d.h., dass der translatorisch diffusive Ionentransport entlang der Hauptkette stattfindet und nicht zwischen benachbarten Seitenketten. Ein Hauptaugenmerk der Untersuchungen liegt sowohl bei den lithiumionen- als auch den protonenleitfähigen Polymermembranen auf temperaturabhängigen dynamischen Prozessen der jeweiligen Ionenspezies in der polymeren Matrix, was die Ionenleitfähigkeit selbst, Relaxationsphänomene, die translatorische Ionendiffusion und im Falle der Protonenleiter etwaige mesomere Grenzstrukturübergänge umfasst. Lithiumionenleiter: Poly(meth)acrylate mit (2-Oxo-1,3-dioxolan)resten (Cyclocarbonat-) in der Seitenkette unterschiedlicher Spacerlänge wurden synthetisiert und charakterisiert. Die Leitfähigkeit s(,T) erreicht bei Poly(2-oxo-[1,3]dioxolan-4-yl)methylacrylat (PDOA): Lithium-bis-trifluormethansulfonimid (LiTFSI) (10:3) ca. 10^-3,5 S cm^-1 bei 150 °C. Weichmachen (Dotieren) mit äquimolaren Mengen an Propylencarbonat (PC) bewirkt in allen Fällen einen enormen Anstieg der Leitfähigkeit. Die höchsten Leitfähigkeiten von Mischungen dieser Polymere mit LiTFSI (und LiBOB) werden nicht beim System mit der niedrigsten Tg gefunden. Auch dient Tg nicht als Referenztemperatur (Tref) nach Williams-Landel-Ferry (WLF), so dass eine WLF-Anpassung der Leitfähigkeitsdaten nur über einen modifizierten WLF-Algorithmus gelingt. Die ermittelten Tref liegen deutlich unterhalb von Tg bei Temperaturen, die charakteristisch für die Seitenkettenrelaxation sind („Einfrieren“). Dies legt nahe, dass der Relaxation der Seitenketten eine entscheidende Rolle im Li^+-Leitfähigkeitsmechanismus zukommt. Die Li^+-Überführungszahlen tLi^+ in diesen Systemen schwanken zwischen 0,13 (40 °C) und 0,55 (160 °C). Protonenleiter: Polymere mit Barbitursäure- bzw. Hypoxanthinresten in der Seitenkette und Polyalkylenbiguanide unterschiedlicher Spacerlänge wurden synthetisiert und charakterisiert. Die Leitfähigkeit s(,T) erreicht bei Poly(2,4,6(1H,3H,5H)-trioxopyrimidin-5-yl)methacrylat (PTPMA) maximal ca. 10^-4,4 S cm^-1 bei 140 °C. Höhere Leitfähigkeiten sind nur durch Mischen mit aprotischen Lösungsmitteln erreichbar. Die höchste Leitfähigkeit wird im Falle der Polyalkylenbiguanide bei Polyethylenbiguanid (PEB) erzielt. Sie erreicht 10^-2,4 S cm^-1 bei 190 °C. Die Aktivierungsenergien EA der Polyalkylenbiguanide liegen (jeweils unterhalb von Tg) zwischen ca. 3 – 6 kJ mol^-1. In allen beobachteten Fällen dient Tg als Tref, so dass eine konventionelle WLF-Behandlung möglich ist und davon auszugehen ist, dass die Leitfähigkeit mit dem freien Volumen Vf korreliert.