957 resultados para Linearity


Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study provides a versatile validated method to determine the total vitamin C content, as the sum of the contents of L-ascorbic acid (L-AA) and dehydroascorbic acid (DHAA), in several fruits and vegetables and its degradability with storage time. Seven horticultural crops from two different origins were analyzed using an ultrahigh-performance liquid chromatographic–photodiode array (UHPLC-PDA) system, equipped with a new trifunctional high strength silica (100% silica particle) analytical column (100 mm×2.1 mm, 1.7 μm particle size) using 0.1% (v/v) formic acid as mobile phase, in isocratic mode. This new stationary phase, specially designed for polar compounds, overcomes the problems normally encountered in HPLC and is suitable for the analysis of large batches of samples without L-AA degradation. In addition, it proves to be an excellent alternative to conventional C18 columns for the determination of L-AA in fruits and vegetables. The method was fully validated in terms of linearity, detection (LOD) and quantification (LOQ) limits, accuracy, and inter/intraday precision. Validation experiments revealed very good recovery rate of 96.6±4.4% for L-AA and 103.1±4.8 % for total vitamin C, good linearity with r2-values >0.999 within the established concentration range, excellent repeatability (0.5%), and reproducibility (1.6%) values. The LOD of the method was 22 ng/mL whereas the LOQ was 67 ng/mL. It was possible to demonstrate that L-AA and DHAA concentrations in the different horticulture products varied oppositely with time of storage not always affecting the total amount of vitamin C during shelf-life. Locally produced fruits have higher concentrations of vitamin C, compared with imported ones, but vegetables showed the opposite trend. Moreover, this UHPLC-PDA methodology proves to be an improved, simple, and fast approach for determining the total content of vitamin C in various food commodities, with high sensitivity, selectivity, and resolving power within 3 min of run analysis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This manuscript describes the development and validation of an ultra-fast, efficient, and high throughput analytical method based on ultra-high performance liquid chromatography (UHPLC) equipped with a photodiode array (PDA) detection system, for the simultaneous analysis of fifteen bioactive metabolites: gallic acid, protocatechuic acid, (−)-catechin, gentisic acid, (−)-epicatechin, syringic acid, p-coumaric acid, ferulic acid, m-coumaric acid, rutin, trans-resveratrol, myricetin, quercetin, cinnamic acid and kaempferol, in wines. A 50-mm column packed with 1.7-μm particles operating at elevated pressure (UHPLC strategy) was selected to attain ultra-fast analysis and highly efficient separations. In order to reduce the complexity of wine extract and improve the recovery efficiency, a reverse-phase solid-phase extraction (SPE) procedure using as sorbent a new macroporous copolymer made from a balanced ratio of two monomers, the lipophilic divinylbenzene and the hydrophilic N-vinylpyrrolidone (Oasis™ HLB), was performed prior to UHPLC–PDA analysis. The calibration curves of bioactive metabolites showed good linearity within the established range. Limits of detection (LOD) and quantification (LOQ) ranged from 0.006 μg mL−1 to 0.58 μg mL−1, and from 0.019 μg mL−1 to 1.94 μg mL−1, for gallic and gentisic acids, respectively. The average recoveries ± SD for the three levels of concentration tested (n = 9) in red and white wines were, respectively, 89 ± 3% and 90 ± 2%. The repeatability expressed as relative standard deviation (RSD) was below 10% for all the metabolites assayed. The validated method was then applied to red and white wines from different geographical origins (Azores, Canary and Madeira Islands). The most abundant component in the analysed red wines was (−)-epicatechin followed by (−)-catechin and rutin, whereas in white wines syringic and p-coumaric acids were found the major phenolic metabolites. The method was completely validated, providing a sensitive analysis for bioactive phenolic metabolites detection and showing satisfactory data for all the parameters tested. Moreover, was revealed as an ultra-fast approach allowing the separation of the fifteen bioactive metabolites investigated with high resolution power within 5 min.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A stir bar sorptive extraction with liquid desorption followed by large volume injection coupled to gas chromatography–quadrupole mass spectrometry (SBSE-LD/LVI-GC–qMS) was evaluated for the simultaneous determination of higher alcohol acetates (HAA), isoamyl esters (IsoE) and ethyl esters (EE) of fatty acids. The method performance was assessed and compared with other solventless technique, the solid-phase microextraction (SPME) in headspace mode (HS). For both techniques, influential experimental parameters were optimised to provide sensitive and robust methods. The SBSE-LD/LVI methodology was previously optimised in terms of extraction time, influence of ethanol in the matrix, liquid desorption (LD) conditions and instrumental settings. Higher extraction efficiency was obtained using 60 min of extraction time, 10% ethanol content, n-pentane as desorption solvent, 15 min for the back-extraction period, 10 mL min−1 for the solvent vent flow rate and 10 °C for the inlet temperature. For HS-SPME, the fibre coated with 50/30 μm divinylbenzene/carboxen/polydimethylsiloxane (DVB/CAR/PDMS) afforded highest extraction efficiency, providing the best sensitivity for the target volatiles, particularly when the samples were extracted at 25 °C for 60 min under continuous stirring in the presence of sodium chloride (10% (w/v)). Both methodologies showed good linearity over the concentration range tested, with correlation coefficients higher than 0.984 for HS-SPME and 0.982 for SBES-LD approach, for all analytes. A good reproducibility was attained and low detection limits were achieved using both SBSE-LD (0.03–28.96 μg L−1) and HS-SPME (0.02–20.29 μg L−1) methodologies. The quantification limits for SBSE-LD approach ranging from 0.11 to 96.56 μg L−and from 0.06 to 67.63 μg L−1 for HS-SPME. Using the HS-SPME approach an average recovery of about 70% was obtained whilst by using SBSE-LD obtained average recovery were close to 80%. The analytical and procedural advantages and disadvantages of these two methods have been compared. Both analytical methods were used to determine the HAA, IsoE and EE fatty acids content in “Terras Madeirenses” table wines. A total of 16 esters were identified and quantified from the wine extracts by HS-SPME whereas by SBSE-LD technique were found 25 esters which include 2 higher alcohol acetates, 4 isoamyl esters and 19 ethyl esters of fatty acids. Generally SBSE-LD provided higher sensitivity with decreased analysis time.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Stir bar sorptive extraction and liquid desorption followed by large volume injection coupled to gas chromatography–quadrupole mass spectrometry (SBSE–LD/LVI-GC–qMS) had been applied for the determination of volatiles in wines. The methodology was optimised in terms of extraction time and influence of ethanol in the matrix; LD conditions, and instrumental settings. The optimisation was carried out by using 10 standards representative of the main chemical families of wine, i.e. guaiazulene, E,E-farnesol, β-ionone, geranylacetone, ethyl decanoate, β-citronellol, 2-phenylethanol, linalool, hexyl acetate and hexanol. The methodology shows good linearity over the concentration range tested, with correlation coefficients higher than 0.9821, a good reproducibility was attained (8.9–17.8%), and low detection limits were achieved for nine volatile compounds (0.05–9.09 μg L−1), with the exception of 2-phenylethanol due to low recovery by SBSE. The analytical ability of the SBSE–LD/LVI-GC–qMS methodology was tested in real matrices, such as sparkling and table wines using analytical curves prepared by using the 10 standards where each one was applied to quantify the structurally related compounds. This methodology allowed, in a single run, the quantification of 67 wine volatiles at levels lower than their respective olfactory thresholds. The proposed methodology demonstrated to be easy to work-up, reliable, sensitive and with low sample requirement to monitor the volatile fraction of wine.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A RP-HPLC method with photodiode array detection (DAD) was developed to separate, identify and quantify simultaneously the most representative phenolic compounds present in Madeira and Canary Islands wines. The optimized chromatographic method was carefully validated in terms of linearity, precision, accuracy and sensitivity. A high repeatability and a good stability of phenolics retention times (a3%) were obtained, as well as relative peak area. Also high recoveries were achieved, over 80.3%. Polyphenols calibration curves showed a good linearity (r2 A0.994) within test ranges. Detection limits ranged between 0.03 and 11.5 lg/mL for the different polyphenols. A good repeatability was obtained, with intra-day variations less than 7.9%. The described method was successfully applied to quantify several polyphenols in 26 samples of different kinds of wine (red, ros and white wines) from Madeira and Canary Islands. Gallic acid was by far the most predominant acid. It represents more than 65% of all phenolics, followed by p-coumaric and caffeic acids. The major flavonoid found in Madeira wines was trans-resveratrol. In some wines, (–)-epicatechin was also found in highest amount. Canary wines were shown to be rich in gallic, caffeic and p-coumaric acids and quercetin.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A large number of evidences correlate elevated levels of homocysteine (Hcys) with a higher cardiovascular diseases (CVDs) risk, especially, atherosclerosis. Similarly, abnormal low levels of the vitamins B6, B9 and B12 are associated to an instability in the methionine cycle with an over production of Hcys. Thus, biomedical sciences are looking forward for a cheaper, faster, precise and accurate analytical methodology to quantify these compounds in a suitable format for the clinical environment. Therefore the objective of this study was the development of a simple, inexpensive and appropriate methodology to use at the clinical level. To achieve this goal, a procedure integrating a digitally controlled (eVol®) microextraction by packed sorbent (MEPS) and an ultra performance liquid chromatography (UPLC) coupled to a photodiode array detector (PDA) was developed to identify and quantify Hcys vitamins B6, B9 and B12. Although different conditions were assayed, we were not able to combine Hcys with the vitamins in the same analytical procedure, and so we proceeded to the optimization of two methods differing only in the composition of the gradient of the mobile phase and the injected volume. It was found that MEPS did not bring any benefit to the quantification of the Hcys in the plasma. Therefore, we developed and validate an alternative method that uses the direct injection of treated plasma (reduced and precipitated). This same method was evaluated in terms of selectivity, linearity, limit of detection (LOD), limit of quantification (LOQ), matrix effect and precision (intra-and inter-day) and applied to the determination of Hcys in a group composed by patients presenting augmented CVD risk. Good results in terms of selectivity and linearity (R2> 0.9968) were obtained, being the values of LOD and LOQ 0.007 and 0.21 mol / L, respectively. The intra-day precision (1.23-3.32%), inter-day precision (5.43-6.99%) and the recovery rate (82.5 to 93.1%) of this method were satisfactory. The matrix effect (>120%) was, however, higher than we were waiting for. Using this methodology it was possible to determine the amount of Hcys in real plasma samples from individuals presenting augmented CVD risk. Regarding the methodology developed for vitamins, despite the optimization of the extraction technique and the chromatographic conditions, it was found that the levels usually present in plasma are far below the sensitivity we obtained. Therefore, further optimizations of the methodology developed are needed. As conclusion, part of the objectives of this study was achieved with the development of a quick, simple and cheaper method for the quantification of Hcys.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Nowadays, the search for new technologies that are able to follow the upcoming challenges in oil industry is a constant. Always trying properties improvements of the used materials, looking for the best performance and greater life time. Besides the search for technologies that show an improvement of performance, the search for materials environmentally correct along the whole production process. In Oil well cementing, this search for new technologies passes through the development of slurry systems that support these requests and that are also environmentally friendly. In this context, the use of geopolymer slurries is a great alternative route to cementing oil wells. Besides having good properties, comparable to Portland cement slurries, this alternative material releases much less CO2 gas in the production of their root materials when compared the production of Portland cement, which releases tons of CO2. In order to improve the properties of geopolymer slurries has been added Calcium Oxide, as observed in other studies that slurries where the Calcium is present the values of compressive strength is greater. The addition has been realized based in the CaO/SiO2 molar ratio of 0.05, 0.10 and 0.15. Have been performed compressive strength tests, thickening time, rheology and fliud loss control test of the slurries, following NBR 9831, as well as the physical chemical characterization of XRD, SEM and TG. Has been observed in most of the tests the slurries follow a tendency until the ratio of 0.10, which inverses in the ratio 0.15. This behavior can be explained by two phenomena that occur simultaneously, the first one is the break of the polymer chains and a consequent increase in molucules mobility, which prevails until the ratio of 0.1, and the second is possible approach of the chains due to the capacity of the calcium ions stabilize the charges of two different aluminum. There is only one linearity in the mechanical behavior that can be attributed to the appereance of the C-S-H phase. Based on this, it is concluded that the phenomenon of breaking the polymer chains predominates until the ratio of 0.1, causing an increase of the filtrate volume, lower rheological parameters and increasing thickening time. From the ratio of 0.15 the approach of the chains predominates, and the behavior is reversed

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: The aim of the study was to investigate physical characteristics and to examine association between somatotype and performance in collegiate runners of 100 m and 400 m. Methods: The sample, male runners (n=39) competing at the regional level in the state of Rio Grande do Norte, Brazil, had height, body mass, skinfolds, limb circumference and skeletal breadths measured. Then, the somatotype was calculated by Health-Carter method. Races (100 m and 400 m) were held to assess athletic performance. Descriptive statistics were calculated for the total sample, as well as for the 100 m and 400 m groups, and established four subgroups, named quartiles. For analysis between groups of runners (100 m x 400 m) was used Student's t test for independent samples. To examine the relationship between the race times and anthropometric variables, was used the Pearson correlation test. The somatotype dispersion distance and somatotype spatial distance were calculated among subgroups. One-way analysis of variance, the Wilcoxon test followed of Tukey post test, and correlation analysis were used with a significance level of p<0.05. Results: Somatotype with mesomorphy and ectomorphy dominance was exhibited by 100 m and 400 m athletes. Endomorphy was low in both groups, especially in 400m runners, who had more elongated body types than 100 m runners. When separately compared by athletic performance quartile, 100 m sprinters of better qualifications (G100-G1) had somatotype with dominant mesomorphy, whereas 400 m runners had somatotype with dominant ectomorphy. A significant correlation (r = -0.55, p=0.008) between calf circumference and 100 m race times was observed showing the importance of muscularity, whereas a significant correlation was found between height and 400 m race times (r = -0.53, p=0.02) showing the importance of linearity. Conclusion: Runners of 100 and 400 may show differences in physical characteristics, depending on the level of athletic performance. Anthropometric periodic evaluations may help in the training process of these athletes. However, more specific assessment parameters should be taken into account, because somatotype by itself has not power to predict whether an individual will succeed in racing speed

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Investigations in the field of pharmaceutical analysis and quality control of medicines require analytical procedures with good perfomance characteristics. Calibration is one of the most important steps in chemical analysis, presenting direct relation to parameters such as linearity. This work consisted in the development of a new methodology to obtain calibration curves for drug analysis: the stationary cuvette one. It was compared to the currently used methodology, and possible sources of variation between them were evaluated. The results demonstrated that the proposed technique presented similar reproducibility compared to the traditional methodology. In addition to that, some advantages were observed, such as user-friendliness, cost-effectiveness, accuracy, precision and robustness. Therefore, the stationary cuvette methodology may be considered the best choice to obtain calibration curves for drug analyis by spectrophotometry

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The ethanol is the most overused psychoactive drug over the world; this fact makes it one of the main substances required in toxicological exams nowadays. The development of an analytical method, adaptation or implementation of a method known, involves a process of validation that estimates its efficiency in the laboratory routine and credibility of the method. The stability is defined as the ability of the sample of material to keep the initial value of a quantitative measure for a defined period within specific limits when stored under defined conditions. This study aimed to evaluate the method of Gas chromatography and study the stability of ethanol in blood samples, considering the variables time and temperature of storage, and the presence of preservative and, with that check if the conditions of conservation and storage used in this study maintain the quality of the sample and preserve the originally amount of analyte present. Blood samples were collected from 10 volunteers to evaluate the method and to study the stability of ethanol. For the evaluation of the method, part of the samples was added to known concentrations of ethanol. In the study of stability, the other side of the pool of blood was placed in two containers: one containing the preservative sodium fluoride 1% and the anticoagulant heparin and the other only heparin, was added ethanol at a concentration of 0.6 g/L, fractionated in two bottles, one being stored at 4ºC (refrigerator) and another at -20ºC (freezer), the tests were performed on the same day (time zero) and after 1, 3, 7, 14, 30 and 60 days of storage. The assessment found the difference in results during storage in relation to time zero. It used the technique of headspace associated with gas chromatography with the FID and capillary column with stationary phase of polyethylene. The best analysis of chromatographic conditions were: temperature of 50ºC (column), 150ºC (jet) and 250ºC (detector), with retention time for ethanol from 9.107 ± 0.026 and the tercbutanol (internal standard) of 8.170 ± 0.081 minutes, the ethanol being separated properly from acetaldehyde, acetone, methanol and 2-propanol, which are potential interfering in the determination of ethanol. The technique showed linearity in the concentration range of 0.01 and 3.2 g/L (0.8051 x + y = 0.6196; r2 = 0.999). The calibration curve showed the following equation of the line: y = x 0.7542 + 0.6545, with a linear correlation coefficient equal to 0.996. The average recovery was 100.2%, the coefficients of variation of accuracy and inter intra test showed values of up to 7.3%, the limit of detection and quantification was 0.01 g/L and showed coefficient of variation within the allowed. The analytical method evaluated in this study proved to be fast, efficient and practical, given the objective of this work satisfactorily. The study of stability has less than 20% difference in the response obtained under the conditions of storage and stipulated period, compared with the response obtained at time zero and at the significance level of 5%, no statistical difference in the concentration of ethanol was observed between analysis. The results reinforce the reliability of the method of gas chromatography and blood samples in search of ethanol, either in the toxicological, forensic, social or clinic

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Compounded medicines have been reported by the ANVISA due to decreased of the therapeutic response or toxicity of these formulations. The aim of this work was to investigate the physicochemical quality control among naproxen sodium oral suspensions 25 mg/mL obtained from six compounding pharmacies (A, B, C, D, E and F) and the manufactured suspension (R). In the quality control test, the tests of pH, content, homogeneity, volume and physical and organoleptic characteristics were performed according to the Brazilian Pharmacopoeia. The analytical method for determination of naproxen in suspensions was validate. This method showed excellent precision, accuracy, linearity and specificity. In the content test the suspensions B, C and E showed lower value and the F suspension showed a high value of the content. The products C and E were disapproved in the description of the physical and organoleptic characteristics test. In the pH test, three suspensions were outside specifications (C, E and F). Only the products R, A and D showed satisfactory results in these tests and therefore they were approved for relative bioavailability test. The R, A and D suspensions were orally administered to Wistar rats and the blood samples were taken at time intervals of 10, 20, 40, 60 min, 3, 4, 6, 24 and 48 h. The plasma samples were immediately stored at 80 ºC until analysis of HPLC. The bioanalytical method validation showed specificity, linearity (R2 0.9987), precision, accuracy, good recovery and stability. The chromatographic conditions were: flow rate of 1.2 mL.min-1 with a mobile phase of acetonitrile : sodium phosphate buffer pH 4.0 (50:50, v/v) at 280 nm, using a C18 column. The confidence interval of 90% for the Cmax and AUCt ratio was within the range of 80 - 125% proposed by the FDA. Only one suspension, obtained from the compounding pharmacy D, was considered bioequivalent to the rate of absorption under the conditions proposed by this study. Thus, the results indicate the need for strict supervision from the relevant authorities to ensure the patient safety and the quality of compounded drugs by pharmacies

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Tuberculosis is a serious disease, but curable in practically 100% of new cases, since complied the principles of modern chemotherapy. Isoniazid (ISN), Rifampicin (RIF), Pyrazinamide (PYR) and Chloride Ethambutol (ETA) are considered first line drugs in the treatment of tuberculosis, by combining the highest level of efficiency with acceptable degree of toxicity. Concerning USP 33 - NF28 (2010) the chromatography analysis to 3 of 4 drugs (ISN, PYR and RIF) last in average 15 minutes and 10 minutes more to obtain the 4th drug (ETA) using a column and mobile phase mixture different, becoming its industrial application unfavorable. Thus, many studies have being carried out to minimize this problem. An alternative would use the UFLC, which is based with the same principles of HPLC, however it uses stationary phases with particles smaller than 2 μm. Therefore, this study goals to develop and validate new analytical methods to determine simultaneously the drugs by HPLC/DAD and UFLC/DAD. For this, a analytical screening was carried out, which verified that is necessary a gradient of mobile phase system A (acetate buffer:methanol 94:6 v/v) and B (acetate buffer:acetonitrile 55:45 v/v). Furthermore, to the development and optimization of the method in HPLC and UFLC, with achievement of the values of system suitability into the criteria limits required for both techniques, the validations have began. Standard solutions and tablets test solutions were prepared and injected into HPLC and UFLC, containing 0.008 mg/mL ISN, 0.043 mg/mL PYR, 0.030 mg.mL-1 ETA and 0.016 mg/mL RIF. The validation of analytical methods for HPLC and UFLC was carried out with the determination of specificity/selectivity, analytical curve, linearity, precision, limits of detection and quantification, accuracy and robustness. The methods were adequate for determination of 4 drugs separately without interfered with the others. Precise, due to the fact of the methods demonstrated since with the days variation, besides the repeatability, the values were into the level required by the regular agency. Linear (R> 0,99), once the methods were capable to demonstrate results directly proportional to the concentration of the analyte sample, within of specified range. Accurate, once the methods were capable to present values of variation coefficient and recovery percentage into the required limits (98 to 102%). The methods showed LOD and LOQ very low showing the high sensitivity of the methods for the four drugs. The robustness of the methods were evaluate, facing the temperature and flow changes, where they showed robustness just with the preview conditions established of temperature and flow, abrupt changes may influence with the results of methods

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Bioidentical hormones are defined as compounds that have exactly the same chemical and molecular structure as hormones that are produced in the human body. It is believed that the use of hormones may be safer and more effective than the non-bioidentical hormones, because binding to receptors in the organism would be similar to the endogenous hormone. Bioidentical estrogens have been used in menopausal women, as an alternative to traditional hormone replacement therapy. Thermal data of these hormones are scarce in literature. Thermal analysis comprises a group of techniques that allows evaluating the physical-chemistry properties of a drug, while the drug is subjected to a controlled temperature programming. The thermal techniques are used in pharmaceutical studies for characterization of drugs, purity determination, polymorphism identification, compatibility and evaluation of stability. This study aims to characterize the bioidentical hormones estradiol and estriol through thermal techniques TG/DTG, DTA, DSC, DSC-photovisual. By the TG curves analysis was possible to calculated kinetic parameters for the samples. The kinetic data showed that there is good correlation in the different models used. For both estradiol and estriol, was found zero order reaction, which enabled the construction of the vapor pressure curves. Data from DTA and DSC curves of melting point and purity are the same of literature, showed relation with DSC-photovisual results. The analysis DTA curves showed the fusion event had the best linearity for both hormones. In the evaluation of possible degradation products, the analysis of the infrared shows no degradation products in the solid state

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The synthetic guanylhydrazones WE010 (3,5-di-tert-butil-4-hidroxibenzaldehyde-guanylhydrazone), WE014 (4-bifenilcarboxialdehydeguanylhydrazone) and WE017 (3,4-diclorobenzaldehydeguanylhydrazone) showed high cytotoxic activity in terms of percentage inhibition of cancer cells growth. However, further progress in the development of these drug candidates requires precise and convenient methods for their qualitative and quantitative analyses. The aim of this study was to develop and validate High Performance Liquid Chromatography with diode-array detection (HPLC-DAD) and Ultra Fast Liquid Chromatography with diode-array detection (UFLC-DAD) methods suitable for as simultaneous as isolated determination of studied guanylhydrazones, based on the optimization of chromatographic parameters and obtaining reduced detection times. The chromatographic analyses of analytes by HPLC were performed on C18 ACE analytical column (150 mm x 4.6 mm), with a particle size of 5.0 μm. Among all the conditions assayed, the best results of separation were obtained with a mixture of methanol:water (60:40, v/v) as the mobile phase at a flow rate 1.5mL/min and pH of 3.5 adjusted at acetic acid. The UFLC method was developed by experimetal desing techniques in order to find optimal chromatographic analytical conditions, which were achieved on XR-ODS analytical column (50 mm x 3.0 mm), with a particle size of 2,2 μm, maintained at 25 ºC. The mobile phase was consisted of methanol:water (65:35, v/v) with 0.1% triethylamine (TEA) and pH of 3.5 adjusted at acetic acid, at a flow rate 0.5 mL/min. The procedure were validated following evaluating parameters such as specificity, linearity, limits of detection (LD) and quantification (LQ), precision, accuracy and robustness, giving results within the acceptable range. Although the UFLC method shows better sensitivity (lower values of LD and LQ), robustness (lower rates of relative standard deviation) and minimize spending time and solvent, both developed methods were adequately applied to the analysis of guanylhydrazones molecules, may be used in routine of quality control laboratories. Keywords: guanylhydrazones, HPLC/DAD, UFLC/DAD, validation of analitical method

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of this study was to evaluate the quality of bovine frozen-thawed sperm cells after Percoll gradient centrifugation. Frozen semen doses were obtained from six bulls of different breeds, including three taurine and three Zebu animals. Four ejaculates per bull were evaluated before and after discontinuous Percoll gradient centrifugation. Sperm motility was assessed by computer-assisted semen analysis and the integrity of the plasma and acrosomal membranes, as well as mitochondrial function, were evaluated using a combination of fluorescent probes propidium iodide, fluorescein isothiocyanate-conjugated Pisum sativum agglutinin and 5,5',6,6'-tetrachloro-1,1',3,3'-tetraethylbenzimidazolcarbocyanine iodide. The procedure of Percoll gradient centrifugation increased the percentage of total and progressive sperm motility, beat frequency, rectilinear motility, linearity and rapidly moving cells. In addition, the percentage of cells with intact plasma membrane and mitochondrial membrane potential was increased in post-centrifugation samples. However, the percentage of sperm cells with intact acrosomal membrane was markedly reduced. The method used selected the motile cells with intact plasma membrane and higher mitochondrial functionality in frozen-thawed bull semen, but processing, centrifugation and/or the Percoll medium caused damage to the acrosomal membrane.