999 resultados para Integrated Inverter


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Handling unbalanced and non-linear loads in a three-phase AC power supply has always been a difficult issue. This has been addressed in the literature by either using fast controllers in the fundamental rotating reference frame or using separate controllers in reference frames specific to the harmonics. In the former case, the controller needs to be fast and in the lattercase, besides the need for many controllers, negative-sequence components need to be extracted from the measured signal.This study proposes a control scheme for harmonic and unbalance compensation of a three-phase uninterruptible power supply wherein the problems mentioned above are addressed. The control takes place in the fundamental positive-sequence reference frame using only a set of feedback and feed-forward compensators. The harmonic components are extracted by process of frame transformations and used as feed-forward compensation terms in the positive-sequence fundamental reference frame. This study uses a method wherein the measured signal itself is used for fundamental negative-sequence compensation. As the feed-forward compensator handles the high-bandwidth components, the feedback compensator can be a simple low-bandwidth one. This control algorithm is explained and validated experimentally.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Expanding energy access to the rural population of India presents a critical challenge for its government. The presence of 364 million people without access to electricity and 726 million who rely on biomass for cooking indicate both the failure of past policies and programs, and the need for a radical redesign of the current system. We propose an integrated implementation framework with recommendations for adopting business principles with innovative institutional, regulatory, financing and delivery mechanisms. The framework entails establishment of rural energy access authorities and energy access funds, both at the national and regional levels, to be empowered with enabling regulatory policies, capital resources and the support of multi-stakeholder partnership. These institutions are expected to design, lead, manage and monitor the rural energy interventions. At the other end, trained entrepreneurs would be expected to establish bioenergy-based micro-enterprises that will produce and distribute energy carriers to rural households at an affordable cost. The ESCOs will function as intermediaries between these enterprises and the international carbon market both in aggregating carbon credits and in trading them under CDM. If implemented, such a program could address the challenges of rural energy empowerment by creating access to modern energy carriers and climate change mitigation. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study presents a novel magnetic arm-switch-based integrated magnetic circuit for a three-phase series-shunt compensated uninterruptible power supply (UPS). The magnetic circuit acts as a common interacting field for a number of energy ports, viz., series inverter, shunt inverter, grid and load. The magnetic arm-switching technique ensures equivalent series or shunt connection between the inverters. In normal grid mode (stabiliser mode), the series inverter is used for series voltage correction and the shunt one for current correction. The inverters and the load are effectively connected in parallel when the grid power is not available. These inverters are then used to share the load power. The operation of the inverters in parallel is ensured by the magnetic arm-switching technique. This study also includes modelling of the magnetic circuit. A graphical technique called bond graph is used to model the system. In this model, the magnetic circuit is represented in terms of gyrator-capacitors. Therefore the model is also termed as gyrator-capacitor model. The model is used to extract the dynamic equations that are used to simulate the system using MATLAB/SIMULINK. This study also discusses a synchronously rotating reference frame-based control technique that is used for the control of the series and shunt inverters in different operating modes. Finally, the gyrator-capacitor model is validated by comparing the simulated and experimental results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A topology for voltage-space phasor generation equivalent to a five-level inverter for an open-end winding induction motor is presented. The open-end winding induction motor is fed from both ends by two three-level inverters. The three-level inverters are realised by cascading two two-level inverters. This inverter scheme does not experience neutral-point fluctuations. Of the two three-level inverters only one will be switching at any instant in the lower speed ranges. In the multilevel carrier-based SPWM used for the proposed drive, a progressive discrete DC bias depending on the speed range is given to the reference wave to reduce the inverter switchings. The drive is implemented and tested with a 1 HP open-end winding induction motor and experimental results are presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The commercial automotive mufflers are generally of a complicated shape with multiply connected parts and complex acoustic elements. The analysis of such complex mufflers has always been a great challenge. In this paper, an Integrated Transfer Matrix method has been developed to analyze complex mufflers. Integrated transfer matrix relates the state variables across the entire cross-section of the muffler shell, as one moves along the axis of the muffler, and can be partitioned appropriately in order to relate the state variables of different tubes constituting the cross-section. The paper presents a generalized one-dimensional (1-D) approach, using the transfer matrices of simple acoustic elements, which are available from the literature. The present approach is robust and flexible owing to its capability to construct an overall matrix of the muffler with the transfer matrices of individual acoustic elements and boundary conditions, which can then be used to evaluate the transmission loss, insertion loss, etc. Results from the present approach have been validated through comparisons with the available experimental and three-dimensional finite element method (FEM) based results. The results show good agreement with both measurements and FEM analysis up to the cut-off frequency. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, a new three-phase, five-level inverter topology with a single-dc source is presented. The proposed topology is obtained by cascading a three-level flying capacitor inverter with a flying H-bridge power cell in each phase. This topology has redundant switching states for generating different pole voltages. By selecting appropriate switching states, the capacitor voltages can be balanced instantaneously (as compared to the fundamental) in any direction of the current, irrespective of the load power factor. Another important feature of this topology is that if any H-bridge fails, it can be bypassed and the configuration can still operate as a three-level inverter at its full power rating. This feature improves the reliability of the circuit. A 3-kW induction motor is run with the proposed topology for the full modulation range. The effectiveness of the capacitor balancing algorithm is tested for the full range of speed and during the sudden acceleration of the motor.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents studies on the use of carbon nanotubes dispersed in an insulating fluid to serve as an automaton for healing open-circuit interconnect faults in integrated circuits. The physics behind the repair mechanism is the electric-field-induced diffusion limited aggregation. On the occurrence of an open fault, the repair is automatically triggered due to the presence of an electric field across the gap. We perform studies on the repair time as a function of the electric field and dispersion concentrations with the above application in mind.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Online remote visualization and steering of critical weather applications like cyclone tracking are essential for effective and timely analysis by geographically distributed climate science community. A steering framework for controlling the high-performance simulations of critical weather events needs to take into account both the steering inputs of the scientists and the criticality needs of the application including minimum progress rate of simulations and continuous visualization of significant events. In this work, we have developed an integrated user-driven and automated steering framework INST for simulations, online remote visualization, and analysis for critical weather applications. INST provides the user control over various application parameters including region of interest, resolution of simulation, and frequency of data for visualization. Unlike existing efforts, our framework considers both the steering inputs and the criticality of the application, namely, the minimum progress rate needed for the application, and various resource constraints including storage space and network bandwidth to decide the best possible parameter values for simulations and visualization.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lead-Carbon hybrid ultracapacitors (Pb-C HUCs) with flooded, absorbent-glass-mat (AGM) and silica-gel sulphuric acid electrolyte configurations are developed and performance tested. Pb-C HUCs comprise substrate-integrated PbO2 (SI-PbO2) as positive electrodes and high surface-area carbon with graphite-sheet substrate as negative electrodes. The electrode and silica-gel electrolyte materials are characterized by XRD, XPS, SEM, TEM, Rheometry, BET surface area, and FTIR spectroscopy in conjunction with electrochemistry. Electrochemical performance of SI-PbO2 and carbon electrodes is studied using cyclic voltammetry with constant-current charge and discharge techniques by assembling symmetric electrical-double-layer capacitors and hybrid Pb-C HUCs with a dynamic Pb(porous)/PbSO4 reference electrode. The specific capacitance values for 2 V Pb-C HUCs are found to be 166 F/g, 102 F/g and 152 F/g with a faradaic efficiency of 98%, 92% and 88% for flooded, AGM and gel configurations, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Critical applications like cyclone tracking and earthquake modeling require simultaneous high-performance simulations and online visualization for timely analysis. Faster simulations and simultaneous visualization enable scientists provide real-time guidance to decision makers. In this work, we have developed an integrated user-driven and automated steering framework that simultaneously performs numerical simulations and efficient online remote visualization of critical weather applications in resource-constrained environments. It considers application dynamics like the criticality of the application and resource dynamics like the storage space, network bandwidth and available number of processors to adapt various application and resource parameters like simulation resolution, simulation rate and the frequency of visualization. We formulate the problem of finding an optimal set of simulation parameters as a linear programming problem. This leads to 30% higher simulation rate and 25-50% lesser storage consumption than a naive greedy approach. The framework also provides the user control over various application parameters like region of interest and simulation resolution. We have also devised an adaptive algorithm to reduce the lag between the simulation and visualization times. Using experiments with different network bandwidths, we find that our adaptive algorithm is able to reduce lag as well as visualize the most representative frames.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new type of multi-port isolated bidirectional DC-DC converter is proposed in this study. In the proposed converter, transfer of power takes place through addition of magnetomotive forces generated by multiple windings on a common transformer core. This eliminates the need for a centralised storage capacitor to interface all the ports. Hence, the requirement of an additional power transfer stage from the centralised capacitor can also be eliminated. The converter can be used for a multi-input, multi-output (MIMO) system. A pulse width modulation (PWM) strategy for controlling simultaneous power flow in the MIMO converter is also proposed. The proposed PWM scheme works in the discontinuous conduction mode. The leakage inductance can be chosen to aid power transfer. By using the proposed converter topology and PWM scheme, the need to compute power flow equations to determine the magnitude and direction of power flow between ports is alleviated. Instead, a simple controller structure based on average current control can be used to control the power flow. This study discusses the operating phases of the proposed multi-port converter along with its PWM scheme, the design process for each of the ports and finally experimental waveforms that validate the multi-port scheme.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new hybrid five-level inverter topology with common-mode voltage (CMV) elimination for induction motor drive is proposed in this paper. This topology has only one dc source, and different voltage levels are generated by using this voltage source along with floating capacitors charged to asymmetrical voltage levels. The pulsewidth modulation (PWM) scheme employed in this topology balances the capacitor voltages at the required levels at any power factor and modulation index while eliminating the CMV. This inverter has good fault-tolerant capability as it can be operated in three-or two-level mode with CMV elimination, in case of any failure in the H-bridges. More voltage levels with CMV elimination can be realized from this topology but only in a limited range of modulation index and power factor. Extensive simulation is done to validate the PWM technique for CMV elimination and balancing of the capacitor voltages. The experimental verification of the proposed inverter-fed induction motor is carried out in the linear modulation and overmodulation regions. The steady-state and transient operations of the drive are verified. The dynamics of the capacitor voltage balancing is also tested. The experimental results demonstrate that the proposed topology can be considered for industrial drive applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A 12 V Substrate-Integrated PbO2-Activated Carbon hybrid ultracapacitor (SI-PbO2-AC HUCs) with silica-gel sulfuric acid electrolyte is developed and performance tested. The performance of the silica-gel based hybrid ultracapacitor is compared with flooded and AGM-based HUCs. These HUCs comprise substrate-integrated PbO2 (SI-PbO2) as positive electrodes and high surface-area activated carbon with dense graphite-sheet substrate as negative electrodes. 12 V SI-PbO2-AC HUCs with flooded, AGM and gel electrolytes are found to have capacitance values of 308 F, 184 F, and 269 F at C-rate and can be pulse charged and discharged for 100,000 cycles with only a nominal decrease in their capacitance values. The best performance is exhibited by gel-electrolyte HUCs.