998 resultados para Image statistics
Resumo:
Remote sensing spatial, spectral, and temporal resolutions of images, acquired over a reasonably sized image extent, result in imagery that can be processed to represent land cover over large areas with an amount of spatial detail that is very attractive for monitoring, management, and scienti c activities. With Moore's Law alive and well, more and more parallelism is introduced into all computing platforms, at all levels of integration and programming to achieve higher performance and energy e ciency. Being the geometric calibration process one of the most time consuming processes when using remote sensing images, the aim of this work is to accelerate this process by taking advantage of new computing architectures and technologies, specially focusing in exploiting computation over shared memory multi-threading hardware. A parallel implementation of the most time consuming process in the remote sensing geometric correction has been implemented using OpenMP directives. This work compares the performance of the original serial binary versus the parallelized implementation, using several multi-threaded modern CPU architectures, discussing about the approach to nd the optimum hardware for a cost-e ective execution.
Resumo:
Purpose: Many countries used the PGMI (P=perfect, G=good, M=moderate, I=inadequate) classification system for assessing the quality of mammograms. Limits inherent to the subjectivity of this classification have been shown. Prior to introducing this system in Switzerland, we wanted to better understand the origin of this subjectivity in order to minimize it. Our study aimed at identifying the main determinants of the variability of the PGMI system and which criteria are the most subjected to subjectivity. Methods and Materials: A focus group composed of 2 experienced radiographers and 2 radiologists specified each PGMI criterion. Ten raters (6 radiographers and 4 radiologists) evaluated twice a panel of 40 randomly selected mammograms (20 analogic and 20 digital) according to these specified PGMI criteria. The PGMI classification was assessed and the intra- and inter-rater reliability was tested for each professional group (radiographer vs radiologist), image technology (analogic vs digital) and PGMI criterion. Results: Some 3,200 images were assessed. The intra-rater reliability appears to be weak, particularly in respect to inter-rater variability. Subjectivity appears to be largely independent of the professional group and image technology. Aspects of the PGMI classification criteria most subjected to variability were identified. Conclusion: Post-test discussions enabled to specify more precisely some criteria. This should reduce subjectivity when applying the PGMI classification system. A concomitant, important effort in training radiographers is also necessary.
Resumo:
The package HIERFSTAT for the statistical software R, created by the R Development Core Team, allows the estimate of hierarchical F-statistics from a hierarchy with any numbers of levels. In addition, it allows testing the statistical significance of population differentiation for these different levels, using a generalized likelihood-ratio test. The package HIERFSTAT is available at http://www.unil.ch/popgen/softwares/hierfstat.htm.
Resumo:
The 2005-2006 (FY06) edition of Iowa Public Library Statistics includes information on income, expenditures, collections, circulation, and other measures, including staff. Each section is arranged by size code, then alphabetically by city. The totals and percentiles for each size code grouping are given immediately following the alphabetical listings. Totals for all reporting libraries are given at the end of each section. There are 542 libraries included in this publication; 10 did not report. The Table of Cities and Size Codes lists the libraries alphabetically and gives their size codes. The table allows a user of this publication to locate information about a specific library. The following table lists the size code designations, the population range in each size code, the number of libraries reporting in each size code, and the total population of the reporting libraries in each size code. The total population of the 542 libraries is 2,243,396. Population data is used to determine per capita figures used throughout the publication.
Resumo:
The 2006-2007 (FY07) edition of Iowa Public Library Statistics includes information on income, expenditures, collections, circulation, and other measures, including staff. Each section is arranged by size code, then alphabetically by city. The totals and percentiles for each size code grouping are given immediately following the alphabetical listings. Totals and medians for all reporting libraries are given at the end of each section. There are 543 libraries included in this publication; 530 submitted a report. The table of size codes (page 6) lists the libraries alphabetically. The libraries in each section of the publication are listed by size code, then alphabetically by city. The following table lists the size code designations, the population range in each size code, the number of libraries reporting in each size code, and the total population of the reporting libraries in each size code. The total population served by the 543 libraries is 2,248,279. Population data is used to determine per capita figures throughout the publication.
Resumo:
The aim of this study was to evaluate and compare organ doses delivered to patients in wrist and petrous bone examinations using a multislice spiral computed tomography (CT) and a C-arm cone-beam CT equipped with a flat-panel detector (XperCT). For this purpose, doses to the target organ, i.e. wrist or petrous bone, together with those to the most radiosensitive nearby organs, i.e. thyroid and eye lens, were measured and compared. Furthermore, image quality was compared for both imaging systems and different acquisition modes using a Catphan phantom. Results show that both systems guarantee adequate accuracy for diagnostic purposes for wrist and petrous bone examinations. Compared with the CT scanner, the XperCT system slightly reduces the dose to target organs and shortens the overall duration of the wrist examination. In addition, using the XperCT enables a reduction of the dose to the eye lens during head scans (skull base and ear examinations).
Resumo:
During adolescence, nutrition needs are high; however the literature shows that few adolescents are following standardized nutritional requirements. A few weeks before an intervention about nutrition to high school adolescents in Lausanne, they were invited to fill in a self-reported questionnaire about their nutrition modes and habits, and their self-image satisfaction (N = 198). Results show that only 5% of youth are eating 5 fruits and vegetables per day and only 29% 3 to 5 dairy products. 21% of female and 6% of boys are not satisfied about their self-image, and those exhibiting a poor self-image tend to adopt health compromising eating patterns in a higher proportion. During adolescence it is important not only to investigate the nutritional habits but also one's self image.
Resumo:
The 2007-2008 (FY08) edition of Iowa Public Library Statistics includes information on income, expenditures, collections, circulation, and other measures, including staff. Each section is arranged by size code, then alphabetically by city. The totals and percentiles for each size code grouping are given immediately following the alphabetical listings. Totals and medians for all reporting libraries are given at the end of each section. There are 543 libraries included in this publication; 522 submitted a report. The table of size codes (page 6) lists the libraries alphabetically. The following table lists the size code designations, the population range in each size code, the number of libraries reporting in each size code, and the total population of the reporting libraries in each sizecode. The total population served by the 543 libraries is 2,248,279. Population data is used to determine per capita figures throughout the publication.
Resumo:
The information in this digest comes from the FY08 Iowa Annual Public Library Survey. It reflects the activities of 522 of the 543 public libraries in Iowa. Full details may be found at http://www.statelibraryofiowa.org/ld/statistics. Information for the national rankings on pages 3 to 4 comes from Public Libraries in the United States: Fiscal Year 2006 by the Institute of Museum and Library Services, Washington D.C., December 2008. http://harvester.census.gov/imls/pubs/pls/pub_detail.asp?id=121#
Resumo:
In this paper, we propose two active learning algorithms for semiautomatic definition of training samples in remote sensing image classification. Based on predefined heuristics, the classifier ranks the unlabeled pixels and automatically chooses those that are considered the most valuable for its improvement. Once the pixels have been selected, the analyst labels them manually and the process is iterated. Starting with a small and nonoptimal training set, the model itself builds the optimal set of samples which minimizes the classification error. We have applied the proposed algorithms to a variety of remote sensing data, including very high resolution and hyperspectral images, using support vector machines. Experimental results confirm the consistency of the methods. The required number of training samples can be reduced to 10% using the methods proposed, reaching the same level of accuracy as larger data sets. A comparison with a state-of-the-art active learning method, margin sampling, is provided, highlighting advantages of the methods proposed. The effect of spatial resolution and separability of the classes on the quality of the selection of pixels is also discussed.